Installation of a FUJITSU AIRSTAGE ORION XLTH+ wall-mounted heat pump in Sainte-Marie-Madeleine, Montérégie

In Sainte-Marie-Madeleine, AirGreen installs a FUJITSU ORION XLTH+ on an elevated stand: an R-32 wall-mounted heat pump, heating down to -30 °C, Inverter technology, and meticulous outdoor installation.

By AirGreen Climatisation & Chauffage Admin17 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
17 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a FUJITSU AIRSTAGE ORION XLTH+ wall-mounted heat pump in Sainte-Marie-Madeleine, Montérégie
Installation of a FUJITSU AIRSTAGE ORION XLTH+ wall-mounted heat pump in Sainte-Marie-Madeleine, Montérégie
The full story

The article, chapter by chapter

A compact installation in Sainte-Marie-Madeleine where the outdoor unit had to integrate neatly into a glass-enclosed terrace

At Sainte-Marie-Madeleine, we completed an installation of a FUJITSU AIRSTAGE ORION XLTH wall-mounted heat pump+ in a residence where the location of the outdoor unit required particular attention. The jobsite photo shows a very concrete situation: the outdoor heat pump is located on a terrace, near a brick wall and beneath a large window, with a glass wall immediately to the left.

In such an environment, an installation cannot be planned solely based on the piping length. The unit’s stability, the clearance required for air exchange, winter drainage, accessibility for maintenance, and visual integration on a terrace used by occupants must all be taken into account.

We therefore installed the outdoor unit on a raised metal support, rather than directly on the floor. This configuration is particularly relevant in Quebec: it helps keep the equipment away from accumulations of water, ice, and snow and facilitates the management of water produced during defrost cycles.

The visible result is clean and compact. The FUJITSU unit fits between the glazed wall and the brick façade without unnecessarily obstructing the terrace. The refrigerant piping enters the building near the unit and is protected by a brown line-set cover that blends in with the masonry.

Why this outdoor installation required more precision than a simple ground-level installation

When a wall-mounted heat pump is installed on a terrace, several constraints arise at the same time.

For this Sainte-Marie-Madeleine project, we had to consider, among other things:

  • the proximity of the glazing;
  • the brick façade;
  • the window above and behind the unit;
  • the space available for the support;
  • clearance in front of the fan;
  • people’s movement on the terrace;
  • the routing of the refrigerant lines;
  • water drainage in winter;
  • potential vibrations;
  • future access for HVAC maintenance.

The photo clearly shows that the outdoor unit is not simply resting on four blocks. We used a metal structure to keep it above the terrace level. Separate support points bear the chassis, while the unit itself is secured to the support.

This installation provides a more defined base and allows free space to be maintained beneath the heat pump.

Clearance around the outdoor unit remains essential

A heat pump exchanges a tremendous amount of air with the outdoors.

The front-facing fan must be able to draw in and expel air without significant obstruction. Installing a unit too deeply in an enclosed corner, too close to a solid railing, or facing an obstacle can impair its operation.

Here, despite the relatively limited space, the condenser’s front remains unobstructed. The glass wall is positioned to the side rather than directly in front of the fan.

This type of decision is important because an excellent unit installed in the wrong position can perform less well than a more modest machine installed correctly.

A line-hide cover suited to the brick façade

Another interesting detail of this project concerns the finish around the refrigerant line passage.

The line-hide cover visible on the wall was chosen in a reddish-brown shade that blends with the masonry. Instead of a highly contrasting white duct running across a red brick façade, the technical passage blends more naturally into the building.

This type of finish may seem secondary before the work begins. Yet once the installation is complete, it is precisely what the homeowner will see for years.

At AirGreen, we therefore consider the piping route and exterior finish from the planning stage of the project.

FUJITSU ORION XLTH+: a heat pump designed for cold climates

The FUJITSU AIRSTAGE ORION XLTH+ belongs to Fujitsu’s single-zone H series. The technical documentation provided presents three configurations: 09KTAP1, 12KTAP1, and 15KTAP1. They are designed for heating and cooling, with a heating operating range down to -30 °C.

The exterior photo clearly identifies a FUJITSU AIRSTAGE unit using R-32 refrigerant, but the detailed nameplate is not visible enough to confirm which of the three capacities is installed at this site. We therefore prefer not to arbitrarily assign a specific capacity to the photographed unit.

The range nevertheless includes:

  • 09KTAP1 : 9,000 BTU/h at nominal cooling;
  • 12KTAP1 : 12,000 BTU/h at nominal cooling;
  • 15KTAP1 : 14,500 BTU/h at nominal cooling.

At nominal heating, the capacities are 12,000, 15,300, and 17,400 BTU/h, respectively.

Heating capacity remains high as temperatures drop

The minimum operating temperature is important, but it does not tell the whole story.

In the middle of winter, what also matters is the amount of heat the unit can actually deliver when the outdoor temperature becomes very low.

The FUJITSU specifications indicate that at -30 °C, the three configurations retain maximum capacities corresponding to 113%, 103%, and 101% of their rated reference capacity, respectively. At -26 °C, these values rise to 147%, 128%, and 116%.

For a homeowner in Sainte-Marie-Madeleine, Longueuil, Montreal, Laval, the South Shore, or the North Shore, this information is far more meaningful than a simple “cold climate” logo.

It makes it possible to better evaluate the heat pump as a true heating appliance, rather than merely as a reversible air conditioner used in spring and fall.

The base pan heater is particularly valuable in an installation like this

FUJITSU documentation specifies that the outdoor unit of the ORION XLTH+ is equipped with a base pan heater designed for extremely cold climates.

This feature is directly relevant to the type of installation visible in Sainte-Marie-Madeleine.

In heating mode, an outdoor heat pump can accumulate frost on its heat exchanger. The system then periodically initiates a defrost cycle. The resulting water must be able to drain away before refreezing beneath the unit.

Installing the heat pump on a raised support helps create space beneath the unit for this drainage.

A common mistake: installing a heat pump too close to the ground

On some sites we inspect, the outdoor unit is located almost at ground level or at the level of a terrace.

This can become problematic when:

  • snow accumulates in front of or behind the unit;
  • defrost water forms a mass of ice;
  • the drainage outlets become blocked;
  • the fan draws in snow;
  • technical access becomes difficult.

A heat pump designed to operate down to -30 °C must also be installed appropriately for an environment that can reach -30 °C.

The unit and the installation form a complete system.

Behind this FUJITSU installation in Sainte-Marie-Madeleine: efficiency, quiet operation, R-32, and technical details to know

Exceptionally high energy efficiency

The ORION XLTH+ series offers highly impressive efficiency levels.

Depending on the selected capacity, the FUJITSU specifications indicate SEER2 values of:

  • 33,5 for the 09KTAP1;
  • 31,5 for the 12KTAP1;
  • 28,7 for the 15KTAP1.

The HSPF2 values for Region V are 11.5, 11.3, and 10.7, respectively.

The three configurations are also presented in the documentation as meeting ENERGY STAR, ENERGY STAR Cold Climate, and ENERGY STAR Most Efficient classifications.

These figures are important, but they never replace proper sizing.

Why we do not size a heat pump solely according to square footage

It is common for a homeowner to ask us:

“How many BTUs does my home need?”

Floor area is only part of the answer.

When selecting a wall-mounted heat pump in Sainte-Marie-Madeleine, we must also consider factors such as:

  • the quality of the insulation;
  • the number of windows;
  • the building’s orientation;
  • ceiling height;
  • the presence of a basement;
  • whether the rooms have an open or closed layout;
  • air infiltration;
  • the amount of sunlight received;
  • the existing heating system;
  • winter heating requirements;
  • the possible location of the indoor unit.

An oversized unit is not automatically preferable.

Inverter technology allows the machine to adjust its capacity precisely according to demand.

Inverter technology: a broad modulation range

The product-line documentation shows very broad capacity ranges.

For the 12KTAP1 model, for example, the cooling capacity ranges from 3,100 to 17,300 BTU/h, while the heating capacity ranges from 4,500 to 27,300 BTU/h.

This modulation is particularly useful on days when demand is moderate.

Instead of operating only in on-off cycles, the Inverter compressor can adjust its operation. This helps maintain a more stable temperature and reduce comfort fluctuations.

R-32 refrigerant clearly visible on the installed unit

In the photo of the Sainte-Marie-Madeleine project, the label R32 is directly visible on the side of the outdoor unit.

FUJITSU states in its documentation that R-32 has a global warming potential of 675, compared with 2,088 for R-410A, representing a 68% reduction according to the reference used by the manufacturer.

R-32 therefore enables this generation of heat pumps to significantly reduce the refrigerant’s GWP compared with R-410A.

1/4 in. – 3/8 in. refrigerant piping

The three ORION XLTH+ configurations presented in the documentation use the same pipe sizes:

  • 1/4 in. liquid side;
  • 3/8 in. gas side.

FUJITSU specifies a minimum length of 10 ft and a maximum length of 66 ft, with a maximum vertical difference of 49 ft. The indicated factory charge covers up to approximately 49 ft of piping.

This point becomes particularly important when a new heat pump replaces an existing system.

We never automatically assume that an old set of pipes can be reused. The diameter, condition of the copper, refrigerant compatibility, and manufacturer's requirements must be checked.

Compact outdoor unit: a real advantage in limited spaces

The photographed installation shows exactly why the outdoor format matters.

On this terrace, we had to work around a window, a brick wall, and a glass partition.

Depending on the configuration, the outdoor units in the range are approximately 31 7/16 in. to 32 5/16 in. wide. The 12KTAP1 and 15KTAP1 models are approximately 28 3/16 in. high and 12 3/8 in. deep.

This compactness makes it easier to integrate the unit into areas where available space is more limited.

However, this does not mean that the unit can be placed just anywhere. The manufacturer's clearances remain essential for maintaining adequate airflow.

Relatively quiet outdoor operation

The documentation indicates the following outdoor sound levels:

  • 44 dB(A) for the 09KTAP1 configuration;
  • 48 to 49 dB(A) for the 12KTAP1;
  • 51 to 49 dB(A) for the 15KTAP1, depending on cooling or heating mode.

On a terrace or near windows, sound level is particularly important.

We must also prevent an improperly stabilized installation from turning normal low-level vibrations into noise transmitted to the structure.

This is another reason why the base, support, and mounting points are important.

Up to 23 dB indoors

According to the technical data sheet, the 09KTAP1 and 12KTAP1 indoor units can operate at just 23 dB(A) in quiet mode, while the 15KTAP1 reaches 26 dB(A).

For a bedroom, office, or living room, this feature can be highly appreciated.

A heat pump that heats efficiently but becomes constantly noticeable acoustically can ultimately reduce the comfort it was intended to improve.

Built-in Wi-Fi and AIRSTAGE control

The ORION XLTH+ also features built-in Wi-Fi connectivity with remote control through the AIRSTAGE app.

The documentation also mentions compatibility with several optional interfaces and controllers, including BACnet and Modbus solutions for more advanced integrations.

In a residence, Wi-Fi is mainly useful for:

  • change the temperature remotely;
  • check that the appliance is operating properly;
  • prepare the house before returning;
  • adjust the settings according to your habits;
  • avoid certain oversights during an extended absence.

ProCore copper coils inside

FUJITSU also specifies that the indoor unit uses highly corrosion-resistant ProCore copper coils.

This is a technical detail that receives less attention during purchasing than an efficiency rating, but it directly concerns the design and durability of the indoor heat exchanger.

The question of financial assistance: always verify the exact system

FUJITSU documentation identifies this series' configurations with ENERGY STAR ratings for cold climates.

This may be relevant for financial assistance programs associated with energy-efficient heat pumps in Quebec. However, eligibility and the amount must never be determined solely from the name “ORION XLTH+”.

The indoor model, outdoor model, certified combination, and applicable program criteria must all be verified.

For our customers, this verification is important: a nominal 12,000 BTU heat pump does not automatically mean that the calculation for financial assistance will be based on exactly 12,000 BTU.

Electrical requirements vary according to the selected capacity

The series operates at 208 to 230 V, 60 Hz, single-phase.

The specification sheet states:

  • a 15 A breaker for the 09KTAP1;
  • a 20 A breaker for the 12KTAP1;
  • a 20 A breaker for the 15KTAP1.

This verification must be completed before installation.

In some buildings, particularly when replacing an old heat pump, the existing circuit may not exactly meet the requirements of the new machine.

What the photo from Sainte-Marie-Madeleine shows about a well-planned installation

This installation is interesting because it brings together several details that a homeowner could easily underestimate before the work begins.

The height of the outdoor unit

The support keeps the condenser above the patio. This is beneficial for winter drainage and protection against ground-level accumulation.

Stability

An outdoor unit has a compressor and a fan. An adequate base helps limit movement and vibrations.

The short piping route

The refrigerant line runs directly toward the wall adjacent to the unit. A simple route can reduce unnecessary lengths and make finishing easier.

Integrating the line-set cover

The chosen color blends in with the brick rather than creating a highly visible white line on the façade.

Technical access

The unit remains accessible. We can service it later without having to dismantle a permanent structure that completely surrounds the condenser.

Mistakes we seek to avoid on this type of project

During our HVAC installations in Montreal, Laval, Longueuil, the North Shore, the South Shore, and Montérégie, certain mistakes regularly recur in equipment installed previously.

Among the issues we want to avoid:

  1. Installing the unit directly at snow accumulation level.
    A low-temperature unit must have an environment suited to its winter operation.
  2. Blocking the condenser's front.
    The space available on a terrace should not be optimized at the expense of airflow.
  3. Neglecting vibrations.
    An outdoor unit near a window or living area must be installed on a stable base.
  4. Choosing the piping route solely because it is the fastest to install.
    The route must remain logical, protected, and aesthetically acceptable.
  5. Reusing pipes without checking their diameter.
    The ORION XLTH+ uses 1/4 in. liquid and 3/8 in. gas lines.
  6. Forgetting maintenance access.
    The technician must be able to access the outdoor unit several years from now, not just on the day of installation.
  7. Choosing too many BTUs as a precaution.
    Proper sizing remains preferable to systematic oversizing.

A heat pump designed for Quebec, installed according to the actual building

This FUJITSU ORION XLTH+ wall-mounted heat pump installation in Sainte-Marie-Madeleine clearly shows that a successful project depends as much on the equipment as on its placement.

The ORION XLTH+ offers several features suited to our climate: heating down to -30 °C, an Inverter compressor, a base pan heater, R-32 refrigerant, high energy efficiency, quiet operation, and built-in Wi-Fi.

But all these features must be supported by a consistent installation.

On this project, the terrace, glazing, and brick façade dictated part of our work. The elevated support, unit positioning, and line-set cover finish resulted in a compact, clean installation without turning the outdoor equipment into a visual or physical obstacle.

AirGreen for your FUJITSU installations in Sainte-Marie-Madeleine and Greater Montreal

At AirGreen, we install wall-mounted heat pumps, central systems, and various heating and air conditioning equipment, taking the actual building into account rather than applying the same solution to every property.

Whether the project is in Sainte-Marie-Madeleine, Montreal, Laval, Longueuil, on the North Shore or the South Shore, we assess the required capacity, the layout of the property, the piping, the electrical supply, airflow, the location of the outdoor unit, and the finishing, among other factors.

A heat pump must operate properly in January, cool efficiently in July, and remain practical to maintain for many years after installation.

This is the logic that guides our installations.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment