Installation of a Hitachi airHome 400 wall-mounted heat pump in Bois-des-Filion on Montreal’s North Shore

In Bois-des-Filion, we installed a Hitachi airHome 400 with a long, ceiling-protected run, suitable drainage, and an accessible finish for HVAC maintenance.

By AirGreen Climatisation & Chauffage Admin14 min read
Installation of a Hitachi airHome 400 wall-mounted heat pump in Bois-des-Filion on Montreal’s North Shore
Installation of a Hitachi airHome 400 wall-mounted heat pump in Bois-des-Filion on Montreal’s North Shore
–chapters in this story
14 minreading time
–type of installation
2026year published
The tour

Take a tour of the installation

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

The job

An exposed piping route transformed into an orderly, easy-to-maintain HVAC installation

In this Bois-des-Filion property, our team had to integrate a Hitachi airHome 400 wall-mounted heat pump into a room whose layout required a fully visible technical route. The dark ceiling, the limited space available above the unit, and the impossibility of concealing all the lines inside the wall required precise finishing.

Rather than leaving the refrigerant lines, wiring, and drainage exposed, we organized the route inside rigid line covers installed near the ceiling. The indoor unit was positioned just below this technical line, concentrating the components in the upper part of the room and freeing up the walls at occupant height.

The photograph also shows a white flexible duct on the left side. This detail distinguishes this project from a standard wall-mounted installation with a direct outlet to the exterior. Depending on the building's actual layout, a condensate drain route may require a detour, a transition, or a solution adapted to the available slope. Our priority always remains the same: ensuring reliable water drainage while maintaining access to the components for future inspections.

A unit installed near the ceiling without compromising air intake

The position of an indoor unit directly affects its airflow, noise level, and ease of maintenance. In this Bois-des-Filion installation, the Hitachi airHome 400 is mounted high to project treated air across the room.

This choice offers several advantages:

  • the conditioned air can travel a greater distance before descending;
  • no furniture blocks the air outlet louver;
  • the wall space below the unit remains available;
  • the lines are grouped near the ceiling;
  • the unit remains out of the way of accidental impacts;
  • the transition to the technical route is shorter.

A high installation must nevertheless maintain the necessary clearance above the cabinet. The heat pump draws in ambient air mainly through its upper section. An appliance mounted flush against the ceiling or wedged behind a soffit may lack airflow, become noisier, and lose some of its capacity.

We therefore check the actual space around the unit before securing the wall plate. We must also allow for opening the front panel, removing the filters, and accessing the sides of the unit during future HVAC maintenance.

A horizontal route protected by pipe covers

The long cover visible above the unit protects the bundle connecting the indoor unit to the outdoor condenser. This bundle may include:

  • the liquid line;
  • the insulated gas line;
  • the communication wiring;
  • the required electrical conductors;
  • the condensate drain or certain parts of its route.

In a room where these components cannot be recessed, the quality of the pipe cover becomes an important part of the finish. We aim to create continuous lines, with well-fitted connections and a route that follows the room's architecture.

A poorly planned cover can cause several problems: unnecessary angles, compressed lines, sections that are difficult to open, or a disorderly appearance. In this wall-mounted heat pump project on the North Shore, the main route was kept close to the ceiling to reduce its visual impact.

Why we avoid overly tight bends

Refrigerant lines are made of copper. They must be bent gradually to prevent them from being crushed or restricting the refrigerant flow.

An overly tight bend can:

  • deform the copper;
  • create a restriction;
  • damage the insulation;
  • complicate evacuation;
  • transmit more vibration;
  • make a future repair more difficult.

The pipe cover must therefore be sized according to the actual pipe diameters, not the smallest available size.

The Hitachi airHome 400 range uses different connections depending on capacity. More compact models generally use a 1/4 in. liquid line and a 3/8 in. gas line, while higher-capacity models may require a 1/2 in. or 5/8 in. gas line. The highest-capacity model also uses a 3/8 in. liquid line.

Visible drainage: an element to plan from the outset

In air conditioning, the indoor unit removes moisture from the air. This water must leave the drain pan without backing up or stagnating.

The flexible conduit visible on the left indicates that the drainage route required a solution separate from the main cover. In this type of configuration, we pay particular attention to:

  • the available slope;
  • the height of the outlet point;
  • the stability of the connections;
  • the absence of crushed sections;
  • protection against disconnections;
  • ease of inspection;
  • the risk of drainage noise.

When a gravity drain is possible, it generally remains the simplest solution. If the building configuration does not allow a continuous slope, a condensate pump may sometimes be necessary. The photograph alone cannot confirm all the internal components of this route; what matters is that the solution be tested while operating before the trim is closed up.

Symptoms of inadequate drainage

A homeowner should request an inspection if they observe:

  • water under the unit;
  • a gurgling noise;
  • a damp smell;
  • marks on the wall;
  • intermittent shutdowns;
  • a duct that moves or disconnects;
  • water accumulating in the cover.

During commissioning, we run water through the drainage system to confirm that the route is actually working. A connected drain is not necessarily a functional drain.

A small section of finishing under the unit

Under the right side of the heat pump, a short piece of finishing protects a separate portion of the route. This configuration may be used when certain connections need to descend slightly before joining the main line or when a component must remain accessible.

The goal is not solely aesthetic. The covers protect the piping against:

  • impact;
  • snagging;
  • dust;
  • accidental modifications;
  • premature aging of the insulation.

However, we avoid permanently enclosing components that may require inspection. A professional finish should be able to be opened without damaging the wall or piping.

Why the Hitachi airHome 400 is suitable for this type of residential installation

The Hitachi airHome 400 is an Inverter-technology wall-mounted heat pump available in several capacities. The series covers requirements ranging from 9,000 to 36,000 BTU/h, making it suitable for a bedroom, living area, basement, or larger residential zone.

The photograph does not show the model number clearly enough to read. Therefore, we cannot assign a precise BTU rating to this installation based solely on the cabinet width.

Proper sizing is based on an assessment of the heat load, including:

  • the area actually served;
  • room volume;
  • the insulation level;
  • windows and their orientation;
  • sun exposure;
  • ceiling height;
  • airflow to adjacent spaces;
  • winter heat loss;
  • the number of occupants;
  • heat-generating appliances.

Performance varies depending on the capacity selected

According to the manufacturer's technical table, the airHome 400 series offers, among other features:

  • rated cooling capacities from 9,000 to 33,000 BTU/h;
  • rated heating capacities from 10,000 to 35,000 BTU/h;
  • efficiency of up to 20.0 SEER2;
  • an HSPF2 of up to 9.2 in Region 4 and 8.0 in Region 5;
  • heating operation down to approximately -20.5 °C;
  • the refrigerant R32;
  • an ENERGY STAR certification for the combinations indicated by the manufacturer.

These values are not identical for all capacities. The indoor unit must always be matched with the correct outdoor model, and the specifications for the combination actually installed must be consulted.

The Vector DC Inverter technology in everyday use

The Vector DC Inverter technology allows the compressor to modulate its speed according to the room's needs.

At startup, the heat pump can increase its output to quickly bring the temperature closer to the setpoint. It then reduces its speed to maintain comfort without multiplying complete shutdowns.

This modulation offers several benefits:

  • more stable temperature;
  • fewer abrupt starts;
  • often quieter operation;
  • more consistent dehumidification;
  • consumption adapted to the actual load;
  • better management of shoulder seasons.

In a Bois-des-Filion property, where temperatures can change quickly between day and night, this modulation is particularly useful. The unit can adjust its output instead of constantly operating at full capacity.

A sound level suited to occupied rooms

The 9,000 and 12,000 BTU versions can reach an advertised indoor level of 29 dB(A) in quiet mode. Larger models have different levels because of the greater volume of air they must move.

The actual noise level also depends on the quality of the HVAC installation. Several elements can produce vibration or humming:

  • an inadequately secured wall plate;
  • a line in contact with the ceiling;
  • a vibrating pipe cover;
  • an inadequately supported drain;
  • an improperly secured cabinet;
  • a dirty fan;
  • a fan speed that is too high.

In this project, the long ceiling run therefore required regular fastening of the trim and lines. Properly protected but inadequately supported piping can become audible when the compressor changes speed.

FrostWash to help maintain airflow

The FrostWash function uses a freeze-and-thaw cycle to remove some of the impurities deposited on the indoor coil.

This technology helps limit the degradation of airflow, but it does not replace routine maintenance tasks. The owner must still clean the prefilters and have the unit inspected when airflow decreases.

The manufacturer's documentation also lists a stainless steel prefilter and a PM2.5 activated carbon purification filter. These elements help capture certain particles in recirculated air.

However, a wall-mounted heat pump does not replace an air exchanger. It primarily treats the air already present in the room.

Mold Guard and drying of internal components

After a cooling cycle, the coil and pan may remain damp. The Mold Guard feature circulates air through the unit and heats the coil for a set period to reduce residual moisture.

This feature helps limit conditions that promote odors in a clean unit. It cannot eliminate contamination that is already established.

In an installation with a more elaborate drain route, keeping the pan clean and ensuring proper water drainage remain essential. An automatic function cannot compensate for a clogged pipe or inadequate slope.

A design intended to facilitate maintenance

The airHome 400 series has several features that are useful for technicians:

  • removable side covers;
  • drain connection adaptable to the left or right;
  • removable drain pan;
  • removable fan motor bracket;
  • large mounting plate;
  • front panel that can be removed with few screws;
  • dedicated sensor placement;
  • expanded intake area.

These details are particularly relevant when the unit is installed near a ceiling and surrounded by pipe covers. They provide access to the components without unnecessarily dismantling the entire installation.

Optional Wi-Fi control

An optional Wi-Fi adapter may allow remote control of the heat pump. Depending on the accessories selected, the user can, among other things:

  • adjust the temperature;
  • create a weekly schedule;
  • control the system from a phone;
  • use certain voice commands;
  • follow an estimate of energy costs.

This feature can be useful for a residence that is often unoccupied or for preheating a room before returning home.

Mistakes to avoid with a long indoor run

Installing the covers without checking the drain

The finish should never be closed before the drainage test. A hidden leak can damage the wall or ceiling.

Compressing the conduits into a molding that is too small

The dimensions of the cover must match the actual diameters, insulation, and number of cables.

Adding unnecessary fittings

Each additional fitting or transition makes the route more complicated and can create a vibration point.

Leaving the flexible duct unsupported

A drainage pipe must remain stable. Sagging can trap water and encourage deposits.

Installing the unit too close to the ceiling

The upper air intake and access to the filters must be preserved.

Neglecting the appearance of the routing

A heat pump can function properly while still giving the impression of improvised work. The line covers must follow consistent lines and be fastened uniformly.

A complete commissioning behind the visible finish

The final result shows a functioning unit, with its louver open and indicator lights on. Before reaching this stage, we must carry out several checks:

  1. securing and leveling the wall plate;
  2. preparation of the refrigeration lines;
  3. tightening the connections;
  4. leak test;
  5. vacuuming the system;
  6. wiring check;
  7. drainage test;
  8. inspection of the covers and supports;
  9. cooling test;
  10. heating test.

Vacuuming the system is an essential step. It removes air and moisture from the circuit before the refrigerant is released. An installation that looks successful may experience premature problems if this operation is neglected.

Subsidies and eligibility to be confirmed based on the exact combination

Hitachi's brochure indicates that the airHome 400 range is eligible for several provincial heat pump incentives. Actual eligibility must nevertheless be confirmed based on:

  • the exact indoor and outdoor unit numbers;
  • the recognized certification;
  • the capacity at the reference temperature;
  • the type of building;
  • the purchase and installation date;
  • the rules of the program in effect.

The commercial name Hitachi airHome 400 alone does not guarantee a specific subsidy amount. We must verify the exact combination before providing a definitive estimate.

A functional installation adapted to the realities of the North Shore

This Hitachi airHome 400 wall-mounted heat pump installation in Bois-des-Filion stands out for its visible technical routing and the way it was organized near the ceiling.

The indoor unit remains unobstructed, the louver can distribute air freely, and the lines are protected in accessible line covers. The drainage visible on the left was integrated into the configuration rather than concealed without the possibility of inspection.

At AirGreen, we install wall-mounted heat pumps in Bois-des-Filion, throughout the North Shore, as well as in Montreal, Laval, Longueuil and on the South Shore. Each building presents a different set of challenges. Our role is to bring together performance, reliable drainage, refrigeration quality and a cohesive finish in a single installation.

The steps

The big day, step by step

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
Your numbers

What would it look like at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Going further

    Your own project, step by step

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Every house has its constraints. We see them before we install.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).