AirGreenHITACHI
HITACHI COOLING & HEATING · airHome 400The HITACHI space at AirGreenSix airHome 400 sizes, sold and installed by AirGreen.
All of HITACHI
Free in-home estimate6 systems · 9,000 to 36,000
HITACHI airHome 400 · updated October 28, 2026

HITACHI airHome 400: six sizes, from a 115 V unit to 36,000 BTU/h

The airHome 400 covers more sizes than the other two Hitachi wall series: 9,000 to 36,000 BTU/h, with the range’s only 115 V unit. Hitachi says it heats down to -5°F (-20.5°C), and NEEP certifies every size down to -20°C. Its 24,000 gets $2,100 in LogisVert, the largest amount of our 15 Hitachi wall units.

6systems, the widest choice of the three series
-20.5°Cheating claimed by Hitachi (-5°F)
$2,100LogisVert of the 24,000, the highest of the 15 wall units
29published airHome 400 installations as of Oct. 28, 2026
The HITACHI shop · airHome 400

The six airHome 400 units, right below.

Each product page gives the AHRI number, the certified figures and the LogisVert amount of the size.

AirGreenHITACHI
01 · The six sizes

From 9,000 to 36,000: six systems, six certificates.

Each spec card follows Hitachi’s brochure and the NEEP certificate of its AHRI number, which agree on efficiency and heat at -8.3°C. The maximum at -20°C is the highest output NEEP certifies at that temperature.

RAK-DJ09RHAA + RAC-DJ09WHAAairHome 400 · 9,000 BTU/h

airHome 400 · 9,000 BTU/h

ENERGY STAR (US market)Single-zone and Multi head
AHRI216759655
Rated cooling9,000 BTU/h
Certified heat at -8.3°C6,500 BTU/h
Maximum at -20°C (NEEP)6,000 BTU/h · COP 2.20
SEER2 · EER220.0 · 13.0
HSPF2, Regions IV · V9.2 · 7.5
Power supply208-230/1/60 · MCA 8 A · MOP 15 A
Lines: length · height difference25 m · 15 m
LogisVertNot eligible

ENERGY STAR (US market) without being Cold Climate or Most Efficient; under LogisVert’s 12,000 BTU/h nominal minimum.

See the product
RAK-DJ12RHAA + RAC-DJ12WHAAairHome 400 · 12,000 BTU/h

airHome 400 · 12,000 BTU/h

ENERGY STAR Cold Climate (US market)Most EfficientSingle-zone and Multi head
AHRI216759656
Rated cooling12,000 BTU/h
Certified heat at -8.3°C8,400 BTU/h
Maximum at -20°C (NEEP)8,000 BTU/h · COP 1.91
SEER2 · EER219.5 · 12.0
HSPF2, Regions IV · V9.2 · 7.0
Power supply208-230/1/60 · MCA 9 A · MOP 15 A
Lines: length · height difference25 m · 15 m
LogisVert$1,008
See the product
RAK-EJ12PHAA + RAC-EJ12WHAAairHome 400 · 12,000 BTU/h · 115 V

airHome 400 · 12,000 BTU/h · 115 V

ENERGY STAR Cold Climate (US market)Most EfficientSingle-zone only 115 V
AHRI216759659
Rated cooling12,000 BTU/h
Certified heat at -8.3°C8,400 BTU/h
Maximum at -20°C (NEEP)8,000 BTU/h · COP 1.91
SEER2 · EER219.5 · 12.0
HSPF2, Regions IV · V9.2 · 7.0
Power supply115/1/60 · MCA 18 A · MOP 30 A
Lines: length · height difference25 m · 15 m
LogisVert$1,008

The only 115 V Hitachi wall unit. At maximum, NEEP certifies it at 13,700 BTU/h at 8.3°C (COP 2.85) and 11,700 BTU/h at -8.3°C (COP 2.20).

See the product
RAK-DJ18RHAA + RAC-DJ18WHAAairHome 400 · 18,000 BTU/h

airHome 400 · 18,000 BTU/h

ENERGY STAR Cold Climate (US market)Most EfficientSingle-zone and Multi head
AHRI216759657
Rated cooling18,000 BTU/h
Certified heat at -8.3°C13,300 BTU/h
Maximum at -20°C (NEEP)11,400 BTU/h · COP 1.85
SEER2 · EER219.5 · 12.0
HSPF2, Regions IV · V10.5 · 8.0
Power supply208-230/1/60 · MCA 13 A · MOP 25 A
Lines: length · height difference30 m · 20 m
LogisVert$1,596
See the product
RAK-DJ24RHAA + RAC-DJ24WHAAairHome 400 · 24,000 BTU/h

airHome 400 · 24,000 BTU/h

ENERGY STAR Cold Climate (US market)Most EfficientSingle-zone and Multi head
AHRI216759658
Rated cooling22,000 BTU/h (24,000 size)
Certified heat at -8.3°C17,500 BTU/h
Maximum at -20°C (NEEP)14,000 BTU/h · COP 1.90
SEER2 · EER218.3 · 12.0
HSPF2, Regions IV · V10.0 · 8.0
Power supply208-230/1/60 · MCA 18 A · MOP 25 A
Lines: length · height difference30 m · 20 m
LogisVert$2,100

The largest LogisVert grant of our 15 Hitachi wall units.

See the product
RAK-DJ36PHAA + RAC-DJ36WHAAairHome 400 · 36,000 BTU/h

airHome 400 · 36,000 BTU/h

Not on the ENERGY STAR listSingle-zone only
AHRI216411300
Rated cooling33,000 BTU/h (36,000 size)
Certified heat at -8.3°C25,200 BTU/h
Maximum at -20°C (NEEP)19,600 BTU/h · COP 2.03
SEER2 · EER219.0 · 9.5
HSPF2, Regions IV · V9.5 · 7.5
Power supply208-230/1/60 · MCA 27 A · MOP 40 A
Lines: length · height difference50 m · 30 m
LogisVertNot eligible

Not on the ENERGY STAR list (re-checked Oct. 28, 2026): no LogisVert grant.

See the product
02 · The circuit

208-230 V or 115 V: what your panel must supply, size by size.

Tap a size: the electrical data follow Hitachi’s brochure and installation manual. The 115 V 12,000 is the only Hitachi wall unit that does without a 208-230 V circuit; the 36,000 calls for a 40 A breaker. We check your panel during the visit.

208-230/1/60

airHome 400 · 12,000 BTU/h

Power supply208-230/1/60 (208 to 230 V)
Minimum circuit ampacity (MCA)9 A
Maximum overcurrent protection (MOP)15 A
Protection in the manual15 A fuse
Wire in the manualAWG 14, power and interconnect
Interconnect up to25 m
Voltage208 to 230 V in service

The technical catalogue sets the starting voltage above 85% of the rated voltage, and imbalance at 3% at most.

Start-upA very low starting current

According to Hitachi, the compressor is started by the inverter, hence an extremely low starting current.

ProtectionDual strong PCB

The Canadian page claims protection against voltage surges up to 420 V and normal operation from 130 to 264 V.

03 · Heads and controls

An RHAA head also works on multi-zone; a PHAA head never does.

Hitachi also certifies PHAA versions of the 9,000 to 24,000, with the same figures: in those sizes, we sell the RHAA heads, the ones that keep the multi-zone door open. Hitachi does not publish what the other letters of the model number mean.

RHAASingle-zone and airHome Multi

“Indoor units RAK-DJ-RHAA are compatible with airHome 400 single splits and airHome Multi multi-split systems,” Hitachi writes. Our sizes: 9,000, 12,000, 18,000, 24,000.

PHAASingle-zone only

“Indoor units RAK-DJ-PHAA are compatible with airHome 400 single splits only.” That is the case for our 12,000 · 115 V and 36,000.

Wi-FiOptional SPX-WFG03 adapter

Sold separately, it fits inside the unit. The airCloud Go app runs a weekly schedule, estimates energy cost and answers to Alexa and Google Home.

ThermostatThird-party 5-wire thermostat

Hitachi provides for it, but a third-party thermostat cannot run every exclusive function, FrostWash included.

Wired controlairPoint Room H700 · SPX-URFG1

Optional wired wall controller, to run the unit without the remote.

Several roomsSPX-DST1 distributor

Per the catalogue, up to 13 indoor units on a single wired controller, with cascaded distributors (SPX-WKT4 cables).

Card keySPX-WDC3 cord

Connects the dry contact of a card-key unit, handy for rentals.

RemoteRC-AGU1EAON

Wireless remote of the 9,000 to 24,000, per the airHome 400 technical catalogue.

04 · Heat

Size by size, from 8.3°C down to -20°C.

Tap a size: each column gives the maximum capacity certified by NEEP and the COP at that output. Hitachi’s technical catalogue stops at the 24,000; NEEP also covers the 115 V unit and the 36,000.

Size
airHome 400 · 12,000 BTU/h100% = certified rated capacity at 8.3°C: 12,000 BTU/h · AHRI 216759656
13,700114%8.3°CCOP 3.37
12,000100%-8.3°CCOP 2.25
10,25085%-15°CCOP 2.10
8,00067%-20°CCOP 1.91
certified maximum capacitythe coldest certified point100% reference

NEEP points: 47, 17, 5 and -4°F. A COP of 2 gives 2 kWh of heat for 1 kWh of electricity. NEEP records re-checked Oct. 28, 2026.

05 · Winter

Below -20°C: 14.26 nights a year at Montréal-Trudeau, 7.59 of them in January.

Hitachi writes that the airHome 400 keeps the room warm down to -5°F (-20.5°C). First that floor and what NEEP certifies at -20°C, then the nights below that mark, month by month.

Hitachi’s published heating limitairHome 400 · -20.5°C (-5°F)
below -20°C14.26nights a year
Coldest point certified by NEEP-20°C
Certified maximum at -20°C6,000 to 19,600 BTU/h
COP at that maximum1.85 to 2.20
Published “100%” thresholdNone

Nights: 1981-2010 climate normals, Montréal-Trudeau (ECCC). Certified point: NEEP records by AHRI number, re-checked Oct. 28, 2026.

December2.27
January7.59
February3.57
March0.83

Nights per month with a low below -20°C

1981-2010 climate normals, Montréal-Trudeau, ECCC. April to November: 0. No Hitachi airHome 400 document mentions a base pan heater: we do not promise one on this series.

06 · Sound

29 dB(A) at the lowest on the 9,000 and 12,000, 54 at the highest on the 36,000.

For each size: the lowest speed, the highest, and the outdoor unit. According to Hitachi, its wavy-blade fans keep the small sizes at 29 dB(A) in silent mode.

9,00029 / 44 · out. 51
12,00029 / 46 · out. 51
12,000 · 115 V29 / 46 · out. 51
18,00035 / 48 · out. 52
24,00036 / 51 · out. 53
36,00038 / 54 · out. 58
indoor, SL speed (silent mode)indoor, HH speed (highest)

dB(A), Hitachi brochure; “out.”: outdoor unit at high speed. Hitachi states the 29 dB(A) is measured in silent mode on the 9,000 and 12,000. Measured in an anechoic chamber per the technical catalogue (9,000 to 24,000).

07 · Installation

Up to 50 m of line for the 36,000, 25 m for the small sizes.

Slide the distance between the wall unit and the outdoor unit: each size fades once you pass Hitachi’s published length. The table gives the footprints, width × height × depth.

15 m(49 ft)
3 m55 m
  • Factory charge covers up to 15 m of line (9,000, 12,000, 18,000 and 36,000); beyond that, 10 g of R-32 per metre, 25 g for the 36,000.
  • Outdoor unit on a stand or block, 100 mm off the ground; in cold areas, at least 250 mm between the drain hole and the ground, without bushings.
  • Vacuum for 10 to 15 minutes down to -101 kPa before opening the valves, per the manuals.
  • 36,000: indoor unit 2,300 mm or more above the floor, 65 mm hole in the wall.
9,000RAC-DJ09WHAA · max. height difference 15 m
max. 25 m
12,000RAC-DJ12WHAA · max. height difference 15 m
max. 25 m
12,000 · 115 VRAC-EJ12WHAA · max. height difference 15 m
max. 25 m
18,000RAC-DJ18WHAA · max. height difference 20 m
max. 30 m
24,000RAC-DJ24WHAA · max. height difference 20 m
max. 30 m
36,000RAC-DJ36WHAA · max. height difference 30 m
max. 50 m

Maximum line lengths and height differences published by Hitachi (brochures). We measure the real route during the free visit. 36,000 height difference of 30 m: brochure only. Minimum 3 m (9,000, 12,000, 18,000).

SizeIndoor unitOutdoor unitLiquid – gas lines
9,000780 × 280 × 222 mm · 8 kg660 × 530 × 278 mm · 26 kg1/4 – 3/8 in.
12,000780 × 280 × 222 mm · 8.5 kg750 × 570 × 280 mm · 34 kg1/4 – 3/8 in.
12,000 · 115 V780 × 280 × 222 mm · 8.5 kg750 × 570 × 280 mm · 34 kg1/4 – 3/8 in.
18,000950 × 294 × 230 mm · 11 kg850 × 800 × 298 mm · 47 kg1/4 – 1/2 in.
24,0001,050 × 294 × 255 mm · 14 kg950 × 945 × 370 mm · 73.3 kg1/4 – 5/8 in.
36,0001,100 × 300 × 260 mm · 15 kg950 × 945 × 370 mm · 79.3 kg3/8 – 5/8 in.

Hitachi brochure, width × height × depth and net weight.

08 · Air

The coil cleans itself with ice, the inside dries after every shutdown.

Here FrostWash works on the indoor coil. For the outdoor unit, Hitachi lists FrostWash and DuraSpin on the airHome 600 and 800, not on the 400.

FrostWashThe indoor coil cleans itself with ice

Per the Kitasato Research Center tests cited by Hitachi (test no. 2020_0650, test model RAS-X22K, not an airHome 400), FrostWash removes 99% of viruses, 99% of bacteria and 95% of mould.

AirflowThree times better, per Hitachi

According to Hitachi, FrostWash helps maintain airflow over the years 3 times better than a unit without it (comparison of 2 identical units).

Mold GuardAbout 60 minutes of drying after shutdown

The coil rises to 50°C. Hitachi notes the function prevents mould without removing what is already there; it can be turned off.

FiltersStainless pre-filter and PM2.5 filter

Built-in PM2.5 activated carbon purifying filter, capturing up to 99% of fine particles. A light signals cleaning time; Hitachi publishes no interval for this series.

Dry mode1.1 to 5.31 L/h

Dehumidification from the smallest to the largest size, per Hitachi’s brochure.

EnergyUp to 30% savings

Per Hitachi’s brochure, up to 30% energy savings over a conventional compressor.

09 · LogisVert

$2,100 for the 24,000, nothing for the 9,000 or the 36,000.

Four sizes are “cold climate” in the ENERGY STAR list (US market): Hydro-Québec pays $120 per 1,000 BTU/h of heat certified at -8°C. The 9,000 is ENERGY STAR without being cold climate, and it is under the 12,000 BTU/h nominal minimum; the 36,000 is not on the ENERGY STAR list.

24,00017.5 × $120 = $2,100$2,100
18,00013.3 × $120 = $1,596$1,596
12,0008.4 × $120 = $1,008$1,008
12,000 · 115 V8.4 × $120 = $1,008$1,008
9,000under 12,000 BTU/h nominal cooling$0
36,000not on the ENERGY STAR list$0

Math: heat certified at -8°C, in thousands of BTU/h, × $120. Hydro-Québec: list read Oct. 14, 2026, amounts recomputed Oct. 28, 2026 from the certificates. Full LogisVert rules (eligibility, deadlines, documents): our LogisVert page.

10 · Our installations

29 published airHome 400 installations, 25 of them on the island of Montréal.

A Ville-Marie condo, a terrace, bedrooms: on the island, the airHome 400 is the wall series we have published most. Here is every published place, and three installations in pictures.

Island of Montréal · 25
Ahuntsic-CartiervilleAnjouBaie-D’UrféBeaconsfieldDollard-des-OrmeauxDorvalKirklandNuns’ IslandLe Plateau-Mont-RoyalMont-RoyalMontréalMontréal-EstMontréal-NordWest IslandOutremontPierrefonds-RoxboroRivière-des-Prairies–Pointe-aux-TremblesRosemont–La Petite-PatrieSaint-LaurentSainte-Anne-de-BellevueSennevilleOld PortVille-MarieVilleray–Saint-Michel–Parc-ExtensionWestmount
South Shore · 1
Longueuil
North Shore · 3
BlainvilleBois-des-FilionCharlemagne

Places from the titles of our projects blog articles published as of Oct. 28, 2026: city or borough only. Grouping by territory: ours.

11 · Frequently asked questions

Your questions about the airHome 400, answered.

Hitachi writes -5°F, that is -20.5°C. NEEP certifies every size down to -20°C, with a maximum output of 6,000 BTU/h to 19,600 BTU/h depending on the size. Hitachi publishes no “100%” threshold for this series.

12 · The HITACHI space

More cold, more options: the other wall pages.

Sources, with the date we read them

  1. Hitachi, airHome 400 brochures (EN “January 2025_CA”, FR “December 2024_CA”), AirGreen copies, read Oct. 14, 2026.
  2. Hitachi, “TECHNICAL CATALOGUE 400 MODELS” (TC_NA airHome400 (2024)-00), RAK-DJ09 to DJ24, read Oct. 14, 2026.
  3. Hitachi, installation manuals RAC-DJ09WHAA (IA2683 B), RAC-DJ12WHAA (IA2685 B), RAC-DJ18WHAA (IA2687 C), RAC-DJ36WHAA (EE0024169D rev.0, 10/2024) and RAK-DJ36PHAA (IA2675 A), read Oct. 14, 2026.
  4. Hitachi Cooling & Heating Canada, airHome 400 page (hitachiaircon.com/ca), read Oct. 14, 2026.
  5. NEEP, Cold Climate Air Source Heat Pump List (ashp.neep.org), records by AHRI number, read Oct. 14, 2026 and re-checked Oct. 28, 2026.
  6. ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), read Oct. 14, 2026 and re-checked Oct. 28, 2026. For airHome units, the “markets” field lists the United States.
  7. Hydro-Québec, LogisVert eligible heat pump search tool (homeowner list), read Oct. 14, 2026; amounts recomputed Oct. 28, 2026 from the ENERGY STAR and NEEP certificates, at the rate of LogisVert guide v1.10.
  8. Hydro-Québec, residential LogisVert participant’s guide, version 1.10, September 15, 2026.
  9. Environment and Climate Change Canada, 1981-2010 climate normals, Montréal-Trudeau (station 7025250).
  10. AirGreen, titles of the Hitachi articles on our projects blog published as of Oct. 28, 2026 (places by series).

LogisVert amounts are indicative: the invoice must show the AHRI or ENERGY STAR number, and Hydro-Québec confirms eligibility and the amount when it processes the claim. Price on quotation.