HITACHI parts and accessories: the right part starts with the number on your nameplate
Remotes in French or English, a wired wall control, Wi-Fi, H-Link, port adapters, 8HK heater kits and panels: 34 Hitachi parts in our shop for airHome and airCore 700. Enter your unit’s number. The tool separates what our product pages list for it from what still has to be confirmed with Hitachi, which does not publish most of these part numbers.
Five families of parts
Tap a family to see it further down.
Our 34 Hitachi parts, right below.
Each product page gives the part number and the models it lists. The quote button under each part sends us your request.
Enter your unit’s number: here is what our product pages list for it.
Three levels, always in this order: the part listed for your exact model, the part listed for its series, then the part to confirm with Hitachi. Nothing is ordered without your full number.
On the indoor unit’s nameplate, or the air handler’s for an airCore 700. Try:
An indoor number (RAK, RAI, RAD, RAF), a multi-zone outdoor number (RAM-G) or an airCore 700 air handler number (JPE) works best.
The first letters of the number tell you which family of parts applies.
Read the full number on the nameplate. For a remote or an accessory, the indoor unit’s number is the one that counts; for an airCore 700, the JPE air handler’s. A photo of the nameplate is enough.
| Number starts with | Unit | Models in the shop | Its parts on this page |
|---|---|---|---|
| RAK-DJ | airHome 400 | RAK-DJ09RHAA to DJ24RHAA, RAK-DJ36PHAA ; RAK-DJ07QHAA multi-zone head | remote · control and Wi-Fi · H-Link |
| RAK-EJ | 115 V airHome 400 | RAK-EJ12PHAA | no part listed: to confirm |
| RAK-GJ | airHome 600 · 650 multi-zone head | RAK-GJ09PHAA to GJ24PHAA ; RAK-GJ07QHAA to GJ24QHAA multi-zone heads | remote · control and Wi-Fi · H-Link |
| RAK-XJ | airHome 800 | RAK-XJ09PHAA to XJ24PHAA | remote · control and Wi-Fi · H-Link |
| RAI-GJ | Mini-cassette | RAI-GJ07QHAA to GJ24QHAA | remote · control and Wi-Fi · multi-zone |
| RAD-GJ | Ducted unit | RAD-GJ07QHAA to GJ24QHAA | remote · control and Wi-Fi · multi-zone |
| RAF-FJ | Floor console | RAF-FJ07QHAA to FJ18QHAA | remote · control and Wi-Fi |
| RAM-G | Multi-zone outdoor unit | RAM-G18N2HAA, G24N3HAA, G36N4HAA, G42N5HAA | multi-zone · H-Link |
| JPE | airCore 700 air handler | JPE18B3XB2HS1A, JPE24B3XC2HS1A, JPE36B3XD2HS1A | 8HK and panels |
| PCI · PCIM | airCore 700 cassettes | not sold | panels |
| RAC · PAS | Single-zone and airCore 700 outdoor units | — | enter the indoor number instead |
Hitachi publishes no key for the RAK, RAC, RAM, RAI, RAD or RAF letters: this table follows our product pages. Only the JPE number has a published key: it is decoded on the JPE air handler page.
A RAK-DJ…PHAA is not a RAK-DJ…RHAA. Per Hitachi, the RHAA airHome 400 wall unit works in single-zone and multi-zone systems, the PHAA in single-zone only. Our 9,000 to 24,000 BTU/h RAK-DJ airHome 400 units are RHAA; our part pages mostly list the RAK-DJ09PHAA.
Six families, two languages: twelve remotes in the shop.
Pick the language, then your unit’s row. The second column gives the remote model Hitachi’s catalogues tie to each family: it is our reference when we check the part.
| Unit | Model Hitachi prints | Our part, French version | Other language |
|---|---|---|---|
| airHome 400 · RAK-DJ | RC-AGU1EA0N | PMK-DJ09PHAAR95 | PMK-DJ09PHAAR05 |
| airHome 600 and 650 · RAK-GJ | RC-AGS1EA0N | PMK-GJ09PHAAR94 | PMK-GJ09PHAAR04 |
| airHome 800 · RAK-XJ | RC-BGH1FA0Nper the airHome 800 catalogue | PMK-XJ09PHAAR95 | PMK-XJ09PHAAR05 |
| Floor console · RAF-FJ | RC-BGH1FB0N or RC-BGH1FD0N | RAF-FJ07QHAA018 | RAF-FJ07QHAA005 |
| Ducted · RAD-GJ | RC-AGU1EA0Nsame model as the airHome 400 | SPX-RKDN3 with receiver | SPX-RKDN1 |
| Mini-cassette · RAI-GJ | RC-AGS1EA0Nsame model as the RAK-GJ | SPX-RKCN4 with receiver | SPX-RKCN2 |
| Unit | Model Hitachi prints | Our part, English version | Other language |
|---|---|---|---|
| airHome 400 · RAK-DJ | RC-AGU1EA0N | PMK-DJ09PHAAR05 | PMK-DJ09PHAAR95 |
| airHome 600 and 650 · RAK-GJ | RC-AGS1EA0N | PMK-GJ09PHAAR04 | PMK-GJ09PHAAR94 |
| airHome 800 · RAK-XJ | RC-BGH1FA0Nper the airHome 800 catalogue | PMK-XJ09PHAAR05 | PMK-XJ09PHAAR95 |
| Floor console · RAF-FJ | RC-BGH1FB0N or RC-BGH1FD0N | RAF-FJ07QHAA005 | RAF-FJ07QHAA018 |
| Ducted · RAD-GJ | RC-AGU1EA0Nsame model as the airHome 400 | SPX-RKDN1 with receiver | SPX-RKDN3 |
| Mini-cassette · RAI-GJ | RC-AGS1EA0Nsame model as the RAK-GJ | SPX-RKCN2 with receiver | SPX-RKCN4 |
Hitachi publishes neither these part numbers nor the language of its remotes. French or English follows the label on our product pages, and we confirm it with the distributor when we order.
The technical catalogue makes the RC-AGS1EA0N the standard remote; the multi-zone brochure describes it as an optional receiver kit with a leak alarm. We confirm what your head needs before ordering.
For the JPE, Hitachi names the CIW03-H wall control. Its PC-LH8QE wireless remote is for the other airCore 700 indoor units and is not documented for the JPE. Neither is in our shop.
A wall control, the app, a thermostat or the building’s network.
The red label marks a number Hitachi prints for these units in its catalogues or brochures. The yellow label marks a number to confirm against your model before ordering.
Wired wall control
The control the airHome 600 brochure calls the airPoint Room H700. It appears in the option lists of the airHome 400, 600 and 800 catalogues, and in the multi-zone catalogue, which spells it “SPX-URFG”.
Per the airHome 400 catalogue, one distributor linked to three more lets up to 13 indoor units follow a single wired control.
A 5 m cable from our shop. In its distributor figure and on its zone controller page, Hitachi names the SPX-WKT4 cable: we confirm the right one.
An 8 m cable from our shop to connect the distributor. Hitachi does not publish this number.
Wi-Fi by unit
| Unit | What Hitachi publishes | In our shop |
|---|---|---|
| airHome 400 | SPX-WFG03 adapter, sold separately | no |
| airHome 600 | airCloud Wi-Fi adapter included | SPX-WFA01, listed as an accessory in the airHome 600 brochure: to confirm |
| airHome 800 | SPX-WFG03 adapter supplied, hidden inside the unit | no |
| Multi-zone heads | Optional SPX-WFA01 adapter | SPX-WFA01, plus the SPX-WFG58CM cable on ducted units and mini-cassettes |
| JPE air handler | GA-WFG-N adapter marked not available for the JPE | nothing to offer |
Hitachi airHome 400, 600 and 800 pages; airHome Multi brochures; airCore 700 catalogue. Yet the airCore 700 brochure states the GA-WFG-N for the whole family: until the distributor settles it, we offer nothing for the JPE.
Wi-Fi and thermostats in the shop
The adapter the multi-zone brochures offer as an option for the airHome 400 and 650 heads, the floor console, the mini-cassette and the ducted unit.
An extension cable from our shop for the Wi-Fi adapter of RAD-GJ ducted units and RAI-GJ mini-cassettes. Plan it before the ceiling is closed.
A 5-wire thermostat adapter for airHome, per our product page. Hitachi does not publish it: we confirm it with the distributor.
An adapter for a 24 V 5-wire thermostat, per our product page. Same status as the C1STAT01, and never for a JPE air handler.
Hitachi presents it as a thermostat, Wi-Fi and BACnet adapter for a single VRF indoor unit. Hitachi ties it to neither an airHome nor an airCore 700: we do not offer it without the distributor’s go-ahead.
Buildings: H-Link and dry contacts
The H-Link adapter described in chapter 11 of the airHome 400, 600 and 800 catalogues, where Hitachi writes it “PSC 6RAD”. The multi-zone catalogue does not mention it.
The outdoor unit’s H-Link board, section 12.2 of the multi-zone catalogue. Hitachi publishes no list of compatible units; our product page lists it for the RAM-G18N2, G36N4 and G42N5.
The cord the airHome 400 catalogue calls for to connect a key card’s dry contact to the indoor unit’s circuit board. The multi-zone catalogue gives it section 12.3.
A cord from our shop that sends the unit’s run status and alarm to an outside system. Hitachi does not publish this number.
These connections are made with the power off, on the unit’s circuit board, by a technician. Hitachi also documents the SPX-RTH1 remote sensor (multi-zone catalogue, section 12.4), which is not in our shop.
Port adapters come with the outdoor unit: ours replace a lost or missing one.
Hitachi supplies port adapters with the airHome Multi outdoor unit, in four sizes, and reminds installers to always fit the seal. Pick your compressor: here are its gas ports and the adapters that start from each one.
Port adapters
The first size is the outdoor unit’s port, the second the connected tube. Each card gives our variant, the Hitachi adapter of the same size, its seal and its tightening torque.
7,000 to 12,000 BTU/h heads, 24,000 BTU/h in total at most (Hitachi combination tables).
7,000 to 18,000 BTU/h heads, 36,000 BTU/h in total at most (Hitachi combination tables).
7,000 to 24,000 BTU/h heads, 48,000 BTU/h in total at most (Hitachi combination tables).
No combination table published by Hitachi.
Hitachi notes that the sizes and number supplied vary by model, and publishes no per-unit list. “Port on this model” follows from the port sizes it prints. Work on the R-32 circuit goes to our refrigeration technicians.
Per our product pages: PMRAMD-350BWR11 for RAD-GJ07 to GJ12 ducted units, PMRAD-50DH7004 for the RAD-GJ24, E06200 for RAI-GJ mini-cassettes. Hitachi does not publish these numbers, and our product pages do not cover the 18 sizes.
Our product page lists it for the RAM-G42N5HAA. Hitachi does not describe it or say when it is needed: we check your setup before offering it.
Front panel for RAI-GJ mini-cassettes. Hitachi prints a 620 × 620 mm panel, 30 mm thick, 2.8 or 3.5 kg depending on size, with no part number.
The 8HK kit is chosen from the JPE air handler’s size, not the other way round.
The air handler manual is plain about it: 8HK kits only, and only those listed on the JPE nameplate. Pick your air handler, then read the kit’s number.
8HK kits allowed per air handler
Nominal rating at 240 V, as Hitachi prints it. Our shop variants carry rounded names.
Only the 14.4 and 19.2 kW kits work in two stages. The electrical rating of each combination is on the JPE air handler page.
Reading an 8HK number
Example: 8HK06500206, the 2.4 kW kit. Tap a segment.
The JPE manual allows only 8HK kits, and only those listed on the air handler nameplate. They are installed in the field; Hitachi offers them single-phase, from 2 to 20 kW.
In Hitachi’s tables: 0 = no service disconnect; 1 = with a disconnect; 2 = with a disconnect and a breaker jumper bar. Our four smaller kits carry the 0, our 14.4 and 19.2 kW kits the 2.
This block tells the six kits apart in Hitachi’s tables: 65002 for the 2.4 kW, up to 65020 for the 19.2 kW. Hitachi publishes no key for it.
Hitachi does not publish what these two digits mean.
A control box from our shop, listed on our product page for the JPE18 to JPE48 air handlers. We confirm it with the distributor for your air handler.
An airCore wall control from our shop. Every Hitachi airCore 700 document prints the CIW03-H (airPoint Room 700): we do not pair the CIW04H with a JPE without the distributor’s go-ahead.
Optional panel for the airCore 700 PCI-B18 to B48UFA1DQ 4-way cassettes, per their Hitachi manual. It is not a heater kit, and we do not sell these cassettes.
Optional panel for the airCore 700 PCIM-B09 and B12UFA1DQ mini-cassettes. It does not fit an airHome RAI-GJ mini-cassette.
CIW03-H wall control or a 5-wire thermostat; as options, the S1-02435672000 breaker moisture seal and the 1BR01117, 1BR01121 and 1BR01124 filter racks. Not available for the JPE, per the technical catalogue: the GA-WFG-N Wi-Fi adapter and the THM-R2A sensor. These options are not in our shop: write to us if your installation needs one.
Price and lead time on request, once the part is checked.
Several parts for the same installation fit in a single request.
- 1Your number
The unit’s model, or a photo of its nameplate, and the part you need. The quote button under each part sends it to us.
- 2The check
We compare your number with our product pages and Hitachi’s documents. When the part is to be confirmed, we ask the distributor.
- 3Price and lead time
You get the price and the lead time before anything is ordered. We publish neither: both depend on the part and the distributor.
- 4Installation
Our technicians install the part. Anything on the R-32 circuit, such as a port adapter, goes to our refrigeration technicians.
A faulty part may fall under your unit’s Hitachi warranty: send us the serial number and the installation date before you buy. Hitachi and AirGreen warranties: explained once for the whole brand, on the HITACHI page.
LogisVert covers a complete system, and Hydro-Québec even excludes replacing a single coil or a single indoor or outdoor unit. Full LogisVert rules (eligibility, deadlines, documents): our LogisVert page.
Six numbers Hitachi prints, and what they change for your part.
Tap a card to flip it: the number is explained on the back, with its document.
Your questions about Hitachi parts, our answers.
On the unit’s nameplate. For a remote or an accessory, the indoor unit’s number is the one that counts (RAK, RAI, RAD or RAF); for an airCore 700, the JPE air handler’s. A photo of the nameplate, sent to sales@airgreen.ca, is enough.
Because Hitachi does not publish most of these part numbers. Our product pages list them for specific models; when your number is not among them, we ask the distributor before ordering.
Per our product pages: airHome 400, PMK-DJ09PHAAR95 in French or PMK-DJ09PHAAR05 in English; airHome 600 and 650, PMK-GJ09PHAAR94 or PMK-GJ09PHAAR04; airHome 800, PMK-XJ09PHAAR95 or PMK-XJ09PHAAR05; floor console, RAF-FJ07QHAA018 or RAF-FJ07QHAA005; ducted unit and mini-cassette, a set with receiver (SPX-RKDN or SPX-RKCN). We confirm the version when we order.
On the airHome 600, Hitachi states an included airCloud adapter, and the airHome 800 comes with the SPX-WFG03 adapter hidden inside the unit. On the single-zone airHome 400, the SPX-WFG03 is bought separately. For a multi-zone head, Hitachi offers the optional SPX-WFA01 adapter. For the JPE air handler, no Wi-Fi adapter is offered.
With an airCore 700, Hitachi provides for running the JPE from a 5-wire thermostat, set up with the CIW03-H control’s function codes; it publishes no list of approved thermostats, so we check yours. For an airHome, our product pages offer the C1STAT01 and C3STAT01 adapters, which Hitachi does not publish: we confirm them with the distributor.
An 8HK kit listed on the air handler nameplate: 2.4 to 9.6 kW on the JPE18, up to 14.4 kW on the JPE24, up to 19.2 kW on the JPE36, nominal at 240 V. We pick the rating with you, from the heat-loss calculation.
We publish neither a price nor a lead time: both depend on the part and its availability at the distributor. The quote button under each part sends us your request, and you get the price and the lead time before anything is ordered.
A faulty part may fall under your unit’s Hitachi warranty: send us the serial number and the installation date before you buy. Hitachi and AirGreen warranties: explained once for the whole brand, on the HITACHI page.
Usually not: Hitachi supplies them with the outdoor unit. Our HWRAM variants replace a lost or missing adapter, and fitting one is a job for a refrigeration technician.
Yes. Our technicians install parts and accessories, and any part on the R-32 circuit goes to our refrigeration technicians. AirGreen, RBQ licence 5645-9605-01 (subclasses 15.8, 15.10 and 16), works in Montréal, Laval, Longueuil, the South Shore and the North Shore.
No question matches. Call us at 514 316-2973.
The right Hitachi part, checked against your number, installed by AirGreen.
Send us your unit’s model number, or a photo of its nameplate, and the part you need: we check, then give you the price and the lead time before ordering.
Monday to Thursday 8 a.m. to 6 p.m. · Friday 8 a.m. to 4 p.m.
Each unit has its own page; its parts are here.




Sources, with the date we read them
- airgreen.ca product pages of the “Hitachi Parts and Accessories” collection (part numbers, listed models), written Oct. 7, 2026, read Oct. 14, 2026.
- Hitachi, airHome 400 technical catalogue (TC_NA airHome400 (2024)-00), sections 10 and 11, yorknow.com, read Oct. 14, 2026.
- Hitachi, airHome 600 and airHome 800 technical catalogues (SPX-URFG1 and PSC 6RAD options), yorknow.com, read Oct. 14, 2026.
- Hitachi, MULTIZONE technical catalogue (TC_ NA airHome Multi-2024 (EN) - 00), sections 3.5 to 3.7, 12 and 13.1, yorknow.com, read Oct. 14, 2026.
- Hitachi, airHome Multi brochures (EN, February 2025; FR, December 2024): SPX-WFA01 Wi-Fi adapter, SPX-URFG1 control, mini-cassette panel.
- Hitachi Cooling & Heating Canada, airHome 400, 600 and 800 pages (Wi-Fi adapters) and zone controller page, read Oct. 14, 2026.
- Hitachi, JPE air handler installation and maintenance manual (6554123), Tables 11 to 15, and airCore 700 technical catalogue (HC2023561C), sections 8.1 and 8.2, yorknow.com, read Oct. 14, 2026.
- Hitachi, airCore 700 PCI (P02362Q) and PCIM (P02390Q) cassette manuals, yorknow.com, read Oct. 14, 2026.
- Hitachi Cooling & Heating (United States), C4STAT01 page, read Oct. 14, 2026.
- Hitachi Cooling & Heating Canada, “Warranties & Training” page (mini-split systems), read Oct. 14, 2026.
- Hydro-Québec, LogisVert page, residential stream, read Oct. 14, 2026.
Price on request.