Hitachi Float Switch for airHome Ducted Unit and Mini-Cassette
The genuine float switch that watches the condensate pan of airHome ducted and mini-cassette units.
AirGreen codeAG-AC-00801
514 316-2973 · sales@airgreen.ca
Quick facts
The float switch monitors the water level in the condensate pan of a ducted or cassette indoor unit. Hitachi assigns a specific part number to each family of multi-zone airHome units: that is what sets apart the three models offered here.
Three floats, three unit families
The manufacturer’s submittal sheets specify the float for each indoor unit. On some, it comes with the unit; on others, it is an optional accessory.
Matching by model
- PMRAMD-350BWR11: RAD-GJ07, RAD-GJ09 and RAD-GJ12QHAA ducted units, as an optional accessory.
- PMRAD-50DH7004: RAD-GJ24QHAA ducted unit, factory-supplied with the unit.
- E06200: RAI-GJ07, RAI-GJ09, RAI-GJ12 and RAI-GJ24QHAA mini-cassettes, factory-supplied.
Before ordering
Note the full model number from the indoor unit’s nameplate, then choose the matching float. The replacement is done inside the unit, near the electrical components: the power must be cut and the work left to a technician. It is also the right time to clean the pan and check the slope and flow of the condensate drain.
Installed by AirGreen across Greater Montréal
Our technicians replace the float and check the whole drainage circuit in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the indoor unit model and quantity.
A float that keeps the water in the pan
The float senses rising condensate in the indoor unit’s pan.
- airHome RAD-GJ07, RAD-GJ09 and RAD-GJ12QHAA ducted units (optional accessory)
- airHome RAD-GJ24QHAA ducted unit (supplied with the unit)
- airHome RAI-GJ07 to RAI-GJ24QHAA mini-cassettes (supplied with the unit)
- Replacing a faulty or damaged float switch
3 sizes, one page
Each size has its own AirGreen code. Tap a row to select it.
| Model | Part no. | Indoor units | Factory status | AirGreen code |
|---|---|---|---|---|
| PMRAMD-350BWR11 – RAD-GJ07 to GJ12 ducted | PMRAMD-350BWR11 | RAD-GJ07, GJ09, GJ12QHAA ducted | Optional accessory | AG-AC-00801 |
| PMRAD-50DH7004 – RAD-GJ24 ducted | PMRAD-50DH7004 | RAD-GJ24QHAA ducted | Supplied with the unit (replacement) | AG-AC-00802 |
| E06200 – RAI-GJ mini-cassette | E06200 | RAI-GJ07, GJ09, GJ12, GJ24QHAA mini-cassettes | Supplied with the unit (replacement) | AG-AC-00803 |
Pick the part number that matches your indoor unit model.
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Read the full indoor unit model number on its nameplate.
- RAD-GJ07 to GJ12: PMRAMD-350BWR11. RAD-GJ24: PMRAD-50DH7004. RAI-GJ: E06200.
- Shut off power to the unit before any work.
- Use the replacement to clean the pan and check the drain flow.
Manufacturer documents
You may also need
High-Capacity Condensate Pump
5/8 in Condensate Drain Hose – 100 ft Roll
Hitachi SPX-RKDN1 Wireless Remote with Receiver for airHome Ducted Unit
Hitachi SPX-RKCN2 Wireless Remote Control with Receiver for airHome Mini-Cassette
Fujitsu Leak Detection System Accessory – UTYSGZU
Hitachi 5-Wire Adapter for 24 V Thermostat – C3STAT01
Hitachi C1STAT01 5-Wire Thermostat Adapter (airHome)
Hitachi Port Adapter for airHome RAM-G Multi-ZoneOriginal partsSee all
Frequently asked questions
Which one fits my unit?
RAD-GJ07, GJ09 or GJ12 ducted: PMRAMD-350BWR11. RAD-GJ24 ducted: PMRAD-50DH7004. RAI-GJ mini-cassette: E06200. Send us the indoor unit model number if in doubt.
Does my unit already have one?
The RAD-GJ24 and the RAI-GJ mini-cassettes ship with their float switch. On the RAD-GJ07 to GJ12, Hitachi offers it as an accessory.
Can I replace it myself?
The work is inside the unit, near electrical parts: have a technician do it.
Can you install it?
Yes. Our technicians replace the float switch and check condensate drainage, everywhere in Greater Montréal.
The genuine float switch for your airHome
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.