5/8 in Condensate Drain Hose – 100 ft Roll

In stock

The 5/8 in flexible hose that carries condensate away from a heat pump’s indoor unit.

AirGreen codeAG-DR-001

5/8 inhose size
100 ftper roll
Flexiblefollows the line set
Condensate drainageWall-mount heat pump
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-DR-001
TypeCondensate drain hose
Size5/8 in
Length100 ft roll

The 5/8 in condensate drain hose carries away the water produced by the indoor unit of a wall-mounted heat pump. Flexible and sold in a 100 ft roll, it follows the refrigerant lines through the wall penetration and is cut to the required length.

Where the water comes from, and where it needs to go

In cooling mode, warm, humid air passes over the indoor unit’s cold coil. The moisture condenses there, runs into the unit’s pan and then into the drain. On heat-wave days, a wall-mounted heat pump can produce several litres of it. If the drain is poorly installed, the water overflows the unit and runs down the wall.

A continuous slope, with no dips

  • The drain works by gravity: it must slope down continuously to the outlet.
  • Avoid dips where water sits and bends so tight they crush the hose.
  • Have it exit away from the foundation, an entrance or a staircase where the water would freeze in winter.
  • Protect the outdoor end from frost and insects.

When gravity is not enough

If the unit is installed on an interior wall or in the basement, the water cannot flow down to the outside. A condensate pump then lifts it to a discharge point. Also check your indoor unit’s drain outlet diameter in its manual.

Supplied and installed by AirGreen across Greater Montréal

Our refrigeration technicians install the drain on every heat pump installation in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the number of rolls you need.

01 · What it is for

Condensate out, and away from the wall

In cooling, the indoor unit pulls moisture out of the air: that water has to leave the house.

  • Drains of wall-mount heat pump indoor units
  • Running the drain to the outside outlet or to a condensate pump
  • Extending or replacing a drain that is too short or damaged
  • Drains of multi-zone indoor heads
100 ft rollCut the length you need, with no extra joints along the way.
FlexibleIt follows the refrigerant lines through the wall penetration and the line-set cover.
5/8 inA common size for wall-mount indoor unit drains.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

TypeFlexible condensate drain hose
Size5/8 in
Roll length100 ft
AirGreen codeAG-DR-001
03 · Before installing

What to know before installing

  • Check the indoor unit’s drain outlet size in its manual.
  • The drain must slope continuously downward, with no dips where water sits.
  • Discharge it away from the foundation, a doorway or a walkway where water would freeze in winter.
  • Outside, protect the end from freezing and insects.
  • When a slope is not possible, a condensate pump takes over.
04 · Goes with

You may also need

Job kitEverything for a wall-mount heat pump install
Line sets, brackets, cover, drain, disconnect and cable on one page.
See the kit
Same category
Condensate drainage
See all
05 · Questions

Frequently asked questions

Will it fit my wall unit?

The drain outlet size is in the indoor unit’s manual. Send us the model and we confirm.

Why is my drain overflowing?

Most often a slope that is too shallow, a dip where water sits, or a blocked or frozen end. A service visit finds the cause.

Can the drain run uphill?

No, it works by gravity. If the water has to go up, you need a condensate pump.

Can you install it?

Yes. Our technicians run the drain on every heat pump installation, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A drain that carries water away, no surprises

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 7, 2026.