High-Capacity Condensate Pump

In stock

The tank-style pump for the larger condensate flows of central heat pumps, furnaces and ducted units.

AirGreen codeAG-DR-00301

115 or 230 V2 voltages
Tankfor larger flows
Basementlifts water to the drain
Condensate drainagePump
Voltage
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-DR-00301
TypeTank-style condensate lift pump
Voltages115 V or 230 V
ForCentral units, furnaces, ducted units

The high-capacity condensate pump is a tank pump that collects water from central equipment and lifts it to a drain: central heat pumps, condensing furnaces and ducted units. It is offered in a 115 V or 230 V version.

Removing water from central equipment in the basement

In many Montréal homes, the furnace and the cooling coil are in the basement, far from the floor drain, or lower than any possible outlet. In summer, the coil produces water on every cooling cycle; a condensing furnace produces it all winter. Without a slope to a drain, that water has to be lifted. The pump collects it in its tank and pushes it to the discharge point.

115 V or 230 V

The voltage is chosen based on the power supply planned near the unit. Electrical connection is reserved for an electrical contractor. AirGreen holds RBQ licence 5645-9605-01, subcategory 16 (electricity), and is a member of the CMEQ.

Installation tips

  • Install the pump level, lower than the unit’s drain outlet.
  • Discharge to an approved point, with a check valve or a loop that keeps water from flowing back.
  • Clean the tank during the annual maintenance: buildup eventually interferes with the pump.

Installed by AirGreen across Greater Montréal

Our technicians install and connect the pump when installing your central heat pump, furnace or ducted unit in Montréal, Laval, Longueuil, the South Shore and the North Shore. RBQ licence 5645-9605-01. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the voltage and quantity.

01 · What it is for

When the floor drain is too far or too high

In a basement, water from central equipment often has to go up before it reaches a drain.

  • Central heat pumps and cooling coils
  • Condensing furnaces
  • Ducted units in a basement or crawl space
  • Replacing a failed lift pump
High capacityA tank sized for the water from central equipment.
115 V or 230 VTwo versions, to match the power available near the equipment.
LiftWater rises to the plumbing drain or the planned outlet.
02 · Sizes

2 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

VoltageAirGreen code
115 VAG-DR-00301
230 VAG-DR-00302

Pump supply voltage.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

TypeTank-style condensate lift pump
Available voltages115 V, 230 V
UseCentral heat pumps, condensing furnaces, ducted units
AirGreen codeAG-DR-00301
04 · Before installing

What to know before installing

  • Choose the voltage from the power supply planned at that spot.
  • The electrical connection is done by an electrical contractor.
  • Set the pump level, below the equipment’s drain outlet.
  • Discharge to an approved point, with a check valve or loop to prevent backflow.
  • Clean the tank during the yearly maintenance.
05 · Goes with

You may also need

Same category
Condensate drainage
See all
06 · Questions

Frequently asked questions

115 V or 230 V: which one?

The one that matches the power planned near the equipment. Our technician determines it during the visit.

How is it different from the wall-mount heat pump pump?

The wall-mount pump is compact and serves one indoor unit. The tank-style lift pump takes the larger flow from central equipment.

Can it take water from both the furnace and the coil?

That is a common basement setup. We check that the pump suits the connected equipment and the lift required.

Can you install it?

Yes. Our technicians install the pump and make its electrical connection when they install your system, everywhere in Greater Montréal.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A dry basement, even far from the drain