AirGreenHITACHI
HITACHI COOLING & HEATING · airCore 700The HITACHI space at AirGreenThree certified central heat pumps, sold and installed by AirGreen on your ducts.
All of HITACHI
Free in-home estimate3 systems · 1.5 to 3 tons
HITACHI airCore 700 · updated October 28, 2026

HITACHI airCore 700 central heat pump: certified down to -25°C, up to $4,200 of LogisVert on the 3-ton

A PAS HeatForce outdoor unit outside, a JPE air handler on your ducts: each pair carries its own AHRI number. Those certificates, not Hitachi’s catalogue, describe the system we sell. Our three pairs are ENERGY STAR Cold Climate for the US and Canada, the 2-ton since October 20, 2026. LogisVert: $1,992 on the 1.5-ton, $4,200 on the 3-ton; the 2-ton’s amount awaits Hydro-Québec’s confirmation.

HITACHIR-32

Three certified pairs

Indicative LogisVert amounts, owner of an existing home: details in section 06.

3AHRI-certified PAS + JPE pairs
-25°Ccoldest point certified by NEEP
$4,200indicative LogisVert, 3-ton
8airCore 700 projects published as of Oct. 28, 2026
The HITACHI shop · airCore 700

The 3 airCore 700 systems, right below.

Each product page carries the AHRI number of its PAS + JPE pair. The sections below explain where those figures come from.

AirGreenHITACHI
01 · Systems

Three PAS + JPE pairs, three AHRI numbers.

Hitachi files the airCore 700 under its commercial split systems and calls it a “Light Commercial Inverter Heat Pump Split System”. Its brochure, though, is written for “light commercial and homes”. Here are the three pairs we install, with the figures from their certificates.

PAS-18BLFASDQ1 + JPE18B3XB2HS1AairCore 700 · 1.5 tons

airCore 700 · 1.5 tons

ENERGY STAR Cold Climate (US and Canada)Most Efficient
AHRI216439111
ENERGY STAR3891106
Certified cooling at 95°F18,000 BTU/h
SEER2 / EER217.5 / 12.3
HSPF2, Region IV / V9.8 / 8.4
Rated heat at -8.3°C16,600 BTU/h
Maximum heat at -25°C15,000 BTU/h · COP 1.89
LogisVert$1,992
See the product
PAS-24BLFASDQ1 + JPE24B3XC2HS1AairCore 700 · 2 tons

airCore 700 · 2 tons

ENERGY STAR Cold Climate (US and Canada)Most Efficient
AHRI216439112
ENERGY STAR3891108 (since Oct. 20, 2026)
Certified cooling at 95°F24,000 BTU/h
SEER2 / EER217.1 / 12.7 *
HSPF2, Region IV / V9.7 / 7.4 *
Rated heat at -8.3°C21,000 BTU/h
Maximum heat at -25°C18,600 BTU/h · COP 1.7
LogisVertnot confirmed

* NEEP record revised Oct. 13, 2026; ENERGY STAR publishes the same values. The HS2 twin (218700907) shows SEER2 15.5, EER2 12.0 and HSPF2 9.7 / 8.5: see section 05.

See the product
PAS-36BLFASDQ1 + JPE36B3XD2HS1AairCore 700 · 3 tons

airCore 700 · 3 tons

ENERGY STAR Cold Climate (US and Canada)Most Efficient
AHRI216439113
ENERGY STAR3891107
Certified cooling at 95°F36,000 BTU/h
SEER2 / EER216.5 / 12.0
HSPF2, Region IV / V10.2 / 8.4
Rated heat at -8.3°C35,000 BTU/h
Maximum heat at -25°C27,100 BTU/h · COP 1.7
LogisVert$4,200
See the product
One AHRI number per pair, not per unit

NEEP lists each pair as “Singlezone Ducted, Centrally Ducted”, sold in the USA and Canada. The ratings, the ENERGY STAR status and the LogisVert amount belong to the pair: changing the JPE or the outdoor unit changes the certificate.

02 · The pair

Hitachi pairs the JPE with a different outdoor unit. The certificates pair it with ours.

Hitachi’s brochure splits the airCore 700 into two outdoor series: “Standard” (PAS-BU) and “HeatForce” (PAS-BL). Our systems use the HeatForce series. Yet the technical catalogue, the brochure and the outdoor-unit manual pair the JPE only with the Standard series. Only the AHRI, NEEP, ENERGY STAR and Hydro-Québec records publish the ratings of the PAS-BL + JPE pair: that is why every figure on this page comes from a certificate.

SourceOutdoor unit paired with the JPEWhat we take from it
Hitachi technical catalogue HC2023561C, section 2.6Standard series, PAS-BUContext only: 18,000, 22,000 and 33,000 BTU/h cooling, SEER2 18.0. It is not the system we sell.
Hitachi brochure airCore700-C-2501Standard series, PAS-BU (its HeatForce tables pair the PAS-BL with the PPIM ducted unit and the cassettes)The “HeatForce” name of our outdoor units, and their physical data
Outdoor-unit manual P02201Q Ver.D (August 2026)Standard series, PAS-BUThe outdoor installation rules of section 07
NEEP, ENERGY STAR, Hydro-QuébecHeatForce series, PAS-BL: the pair we sellEvery certified figure on this page, including 24,000 and 36,000 BTU/h cooling for the 2-ton and 3-ton

The certificates are public: every AHRI number can be checked on ashp.neep.org and on the ENERGY STAR site.

A second JPE certified in August 2026

The outdoor-unit manual dated August 2026 already names the JPE18B3XB2HS2, JPE24B3XC2HS2 and JPE36B3XD2HS2, and ENERGY STAR certified the HS2 1.5-ton and 3-ton on August 11, 2026 with the same outdoor units. Hitachi does not say what the “2” changes. Our product pages show HS1A.

SizeJPE…HS1A (store)JPE…HS2 (certified August 2026)LogisVert
1.5 tonsAHRI 216439111 · ES 3891106AHRI 218700906 · ES 4688452$1,992 (both)
2 tonsAHRI 216439112 · ES 3891108 (Oct. 20, 2026)AHRI 218700907 · not ENERGY STARHS1A: not confirmed · HS2: $0
3 tonsAHRI 216439113 · ES 3891107AHRI 218700908 · ES 4688451$4,200 (both)

Same PAS-BL outdoor unit in both cases. On the 1.5-ton and 3-ton, the HS2 ratings are identical to the HS1A ratings. On the 2-ton, only the HS1A version is ENERGY STAR certified.

03 · Cold

From 8.3°C to -25°C: certified heat, point by point.

NEEP publishes each pair’s values at 8.3°C, -8.3°C and -15°C, then at -25°C, the coldest certified point. Pick a temperature: the bar shows the maximum capacity, the dark tick the rated capacity. For the 2-ton, we also show its HS2 twin (AHRI 218700907): four certificates in all.

Outdoor temperature
1.5-tonAHRI 216439111
25,000 BTU/hrated 20,000 · COP 3.6 · at maximum COP 3.1716,600 BTU/hrated = maximum · COP 2.417,200 BTU/hrated = maximum · COP 2.315,000 BTU/hrated not published · COP 1.89 at maximum
2-ton · JPE…HS1AAHRI 216439112
34,000 BTU/hrated 26,000 · COP 3.79 · at maximum COP 3.233,500 BTU/hrated 21,000 · COP 2.68 · at maximum COP 2.1826,000 BTU/hrated = maximum · COP 1.918,600 BTU/hrated not published · COP 1.7 at maximum
2-ton · HS2 twinAHRI 218700907
34,000 BTU/hrated 26,000 · COP 3.4 · at maximum COP 3.221,000 BTU/hrated = maximum · COP 2.525,600 BTU/hrated = maximum · COP 218,600 BTU/hrated not published · COP 1.7 at maximum
3-tonAHRI 216439113
47,000 BTU/hrated 38,000 · COP 3.4 · at maximum COP 3.2235,000 BTU/hrated = maximum · COP 2.336,600 BTU/hrated = maximum · COP 227,100 BTU/hrated not published · COP 1.7 at maximum
certified maximum capacitycertified rated capacity

NEEP, records by AHRI number (test points 47, 17, 5 and -13°F). At -25°C, NEEP publishes the maximum capacity only. On all four certificates, the capacity at -15°C is higher than the rated capacity at -8.3°C: values published as they are by NEEP and ENERGY STAR. COP: kilowatt-hours of heat per kilowatt-hour of electricity.

Defrost3 to 9 minutes stopped

During defrost, the unit stops for about 3 to 9 minutes, according to Hitachi’s catalogue. Its capacity tables exclude those periods.

HitachiHeats from -25°C to 24°C

Operating range published for every JPE pairing: heating from -25°C to 24°C, cooling from -18°C to 46°C outdoors.

Read closelyThe “-40” is about cooling

Hitachi’s pages quote -40°C for low-ambient cooling needs, not for heating. The published heating floor stays at -25°C.

04 · Montréal

The -25°C limit vs. Montréal-Trudeau’s coldest nights.

From 1981 to 2010, the temperature dropped below -20°C on 14.26 nights a year on average at the airport, and below -30°C on 0.27 nights a year. Environment Canada publishes no -25°C threshold: the airCore 700’s floor falls between those two numbers (AirGreen’s comparison).

Hitachi’s published heating floorairCore 700 · -25°C
below -10°C62.9nights a year
below -20°C14.26nights a year
below -30°C0.27nights a year

1981-2010 climate normals, Montréal-Trudeau, Environment and Climate Change Canada: average number of nights a year when the daily minimum went below each threshold. The station is at the airport; Laval and the North Shore can be colder.

January-14.04°C: the mean daily minimum

In January, at Montréal-Trudeau (1981-2010). At -15°C, NEEP certifies the 3-ton at 36,600 BTU/h and the 1.5-ton at 17,200 BTU/h.

Below -25°CAn 8HK kit as backup

The JPE takes an optional 8HK electric heater kit, 2.4 to 19.2 kW depending on its size: see the allowed kits.

05 · The 2-ton

The 2-ton: revised by NEEP on October 13, ENERGY STAR certified on the 20th.

In one week, our 2-ton’s record (AHRI 216439112) changed twice. NEEP revised its ratings on October 13, 2026: SEER2 17.1 instead of 15.5. ENERGY STAR certified it Cold Climate and Most Efficient on October 20, with the same ratings. Its HS2 twin (AHRI 218700907) keeps the old values and is still not ENERGY STAR: on the 2-ton, the suffix shipped matters.

Published valueJPE…HS1A · AHRI 216439112JPE…HS2 · AHRI 218700907
SEER217.115.5
EER212.712.0
HSPF2 Region IV / V9.7 / 7.49.7 / 8.5
Heat at 8.3°C, rated / maximum (BTU/h)26,000 / 34,00026,000 / 34,000
Heat at -8.3°C, rated / maximum (BTU/h)21,000 / 33,50021,000 / 21,000
COP at -8.3°C, rated / at maximum2.68 / 2.182.5 / 2.5
Heat at -15°C (BTU/h) · COP26,000 · 1.925,600 · 2
Maximum heat at -25°C (BTU/h) · COP18,600 · 1.718,600 · 1.7
ENERGY STAR3891108 · cold climate · Most Efficientnot listed
LogisVertnot confirmed$0 (not ENERGY STAR)

HS1A: NEEP record revised Oct. 13, 2026 and ENERGY STAR certificate 3891108 of Oct. 20, 2026. HS2: NEEP record modified Sept. 21, 2026. Highlighted values: those the October 13 revision changed; ENERGY STAR publishes the same. NEEP records read Oct. 14 and re-checked Oct. 28, 2026, with no further change.

Why no LogisVert amount here

The 2-ton was not on the Hydro-Québec list read Oct. 14, 2026: it was not yet ENERGY STAR certified, a LogisVert condition since November 26, 2025. It has been since October 20. We print no figure before Hydro-Québec confirms it.

HS1A or HS2: the question to ask

If the distributor ships a JPE24B3XC2HS2, the pair becomes 218700907, not ENERGY STAR. We confirm the suffix before the sale, and the invoice carries the AHRI number of the installed pair.

06 · LogisVert

LogisVert: $1,992, $4,200, and the 2-ton to be confirmed.

Hydro-Québec pays $120 per 1,000 BTU/h of output at -8°C when the heat pump is ENERGY STAR Cold Climate. Pick the size: the math follows Hydro-Québec’s list. The invoice must show the AHRI or ENERGY STAR number; Hydro-Québec confirms eligibility and the amount when it processes the claim.

Output at -8°C (Hydro-Québec list)35,000 BTU/hCold-climate rate$120 per 1,000 BTU/hIndicative amount$4,200

AHRI 216439113 · ENERGY STAR 3891107, cold climate, markets “United States, Canada”. The HS2 twin (AHRI 218700908, ENERGY STAR 4688451) receives the same amount.

Hydro-Québec, owner of an existing home: list read Oct. 14, 2026, amounts recomputed Oct. 28, 2026 from the certificates.

What Hydro-Québec says about central heat pumps

DefinitionOne system, one amount

The LogisVert guide defines a central heat pump as a split system with one indoor unit and one outdoor unit: the JPE and the PAS unit, together.

ExcludedReplacing a single unit

Hydro-Québec excludes replacing a single coil, or a single indoor or outdoor unit.

ExcludedDucts outside the insulation

Hydro-Québec excludes installing indoor units, including the air distribution network, outside the home’s insulation envelope.

ExcludedA home with geothermal

Hydro-Québec excludes a central heat pump in a home that already has a geothermal system.

BonusMulti-unit: wall units only

Guide v1.10 limits the multi-unit bonus to ENERGY STAR Cold Climate wall-mounted mini-splits.

RulesDeadlines and documents

Full LogisVert rules (eligibility, deadlines, documents): our LogisVert page.

07 · Outside

The outdoor unit: 50 m of line set, 75 m per the brochure, and snow to watch.

Hitachi’s outdoor-unit manual, written for the PAS-BU series, sets 50 m of line set for 18,000 and 24,000 BTU/h units, and a 30 m height difference. Hitachi’s brochure states up to 75 m for our HeatForce 2-ton and 3-ton: beyond 50 m, we confirm with the distributor. With no manual specific to the PAS-BL, the rules below come from the PAS-BU manual.

20 m(66 ft)
5 m30 m50 m75 m

Up to 30 m: no refrigerant to add, according to Hitachi.

1.5-ton · PAS-18BLFASDQ1max. 50 m of line set · 30 m height difference
within the limit
2-ton · PAS-24BLFASDQ175 m per the brochure · 30 m height difference
within the limit
3-ton · PAS-36BLFASDQ175 m per the brochure · 30 m height difference
within the limit

50 m: Hitachi manual P02201Q (PAS-BU series) and brochure. From 50 to 75 m on the 2-ton and 3-ton: brochure only, to confirm with the distributor. Minimum of 5 m and 30 m without additional charge: manual P02201Q. We measure the real route during the visit.

  1. 1
    A base at least 100 mm (4 in.) high

    The manual calls for a concrete base at least 4 in. high. The catalogue adds that the unit should sit 0.5 m above the highest expected snow.

  2. 2
    Away from blowing snow

    Away from falling and blowing snow, or protected by a canopy, a stand or baffle boards.

  3. 3
    No drain fitting in cold regions

    The manual forbids it: the water can freeze and stop the fan.

  4. 4
    Powered 4 hours before start-up

    The main switch must be on for more than 4 hours before preheating, or the compressor may be damaged. A fast-response earth-leakage breaker (0.1 s), rated for inverters, is required.

  5. 5
    Line diameters confirmed before the work

    The JPE connects at 3/8 in. (liquid) and 3/4 in. (gas). The outdoor manual calls for a reducer at the JPE when the diameters differ, and states that 9,000 and 12,000 BTU/h outdoor units are not compatible with the JPE. We confirm the diameters with the distributor.

According to HitachiR32 compressor with preheating

R32 DC inverter compressor that preheats itself, with no external crankcase heater.

According to HitachiElectronic expansion valve, 16-speed DC motor

Hitachi lists both for the whole airCore 700 range.

According to HitachiNight Quiet Operation

Quieter running at night, plus DRM1, DRM2 and DRM3 demand response, according to Hitachi.

Outdoor unitW × H × DNet weightFactory chargeMax. currentMax. line set
PAS-18BLFASDQ1900 × 665 × 320 mm46 kg (101 lb)1.4 kg (3.09 lb)16.0 A50 m
PAS-24BLFASDQ1950 × 990 × 320 mm88 kg (194 lb)2.6 kg (5.73 lb)24.2 A75 m per the brochure
PAS-36BLFASDQ1950 × 1,380 × 320 mm (ducted table) or 950 × 990 × 320 mm (cassette table)113.5 kg (250 lb)3.4 kg (7.50 lb)29.1 A75 m per the brochure

According to Hitachi brochure airCore700-C-2501. The brochure prints two heights for the PAS-36BL, and Hitachi’s manual (PAS-BU series) limits 24,000 BTU/h units to 50 m of line set: we confirm the height and the length with the distributor before the work.

08 · Warranty

Warranty: Hitachi publishes nothing specific to the airCore 700.

Hitachi publishes no warranty specific to the airCore 700. Its Warranties page (read Oct. 14, 2026) gives, for mini-split systems: 7-year compressor and 5-year parts; 10-year compressor and 10-year parts, at no additional cost, for residential installations registered within 60 days of installation. We confirm with the distributor which coverage applies to your system before the sale.

WhyA “light commercial” system

Hitachi sells the airCore 700 as a light commercial system, and its Warranties page names only mini-split, mini-VRF and VRF systems.

ControlsWall control and Wi-Fi: at the JPE

The CIW03-H control, the 5-wire thermostat and the Wi-Fi question are settled at the indoor unit: see the JPE page.

AirGreenOur own warranty

Hitachi and AirGreen warranties: explained once for the whole brand, on the HITACHI page.

09 · Installations

8 airCore 700 projects published, from Dorval to Montréal-Est.

As of Oct. 28, 2026, our projects blog lists 8 airCore 700 installations. Three titles name a 36,000 BTU/h unit, the 3-ton: Lachine, LaSalle and Le Sud-Ouest.

10 · Frequently asked questions

Your airCore 700 questions, answered.

Not confirmed yet. The 2-ton (AHRI 216439112) has been ENERGY STAR Cold Climate certified since Oct. 20, 2026, but it was not on the Hydro-Québec list read Oct. 14, 2026. The amount also depends on the installation date: Hydro-Québec sets it when it processes your claim.

11 · The HITACHI space

Same brand, other ways to heat.

Sources, with the date we read them

  1. NEEP, Cold Climate Air Source Heat Pump List (ashp.neep.org), records by AHRI number, read Oct. 14, 2026 and re-checked Oct. 28, 2026.
  2. ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), read Oct. 14, 2026 and re-checked Oct. 28, 2026: markets “United States, Canada” for the three airCore 700 pairs.
  3. Hydro-Québec, LogisVert eligible heat pump search tool (homeowner list), read Oct. 14, 2026; amounts recomputed Oct. 28, 2026 from the ENERGY STAR and NEEP certificates, at the rate of LogisVert guide v1.10.
  4. Hydro-Québec, residential LogisVert participant’s guide, version 1.10, September 15, 2026.
  5. Hydro-Québec, residential LogisVert page (exclusions), read Oct. 14, 2026.
  6. Hitachi, airCore 700 technical catalogue HC2023561C (PDF of May 1, 2025), read Oct. 14, 2026.
  7. Hitachi, brochure airCore700-C-2501 “Single split system for light commercial and homes”, read Oct. 14, 2026.
  8. Hitachi, outdoor-unit installation manual PAS-09 to 48BUFASDQ1, P02201Q Ver.D (August 2026), read Oct. 14, 2026.
  9. Hitachi, JPE air handler manual 6554123 (coil connections), read Oct. 14, 2026.
  10. Hitachi Cooling & Heating Canada, airCore700 page (FR and EN), read Oct. 14, 2026.
  11. Hitachi Cooling & Heating Canada, “Warranties & Training” page (mini-split systems), read Oct. 14, 2026.
  12. Environment and Climate Change Canada, 1981-2010 climate normals, Montréal-Trudeau (climate ID 7025250).
  13. AirGreen, projects blog, airCore 700 articles published as of Oct. 28, 2026.

LogisVert amounts are indicative: the invoice must show the AHRI or ENERGY STAR number, and Hydro-Québec confirms eligibility and the amount when it processes the claim. Price on quotation.