Installation of a Samsung WindFree™ MaxHeat wall-mounted heat pump in Montréal-Nord

In Montréal-Nord, AirGreen installs a Samsung WindFree™ MaxHeat heat pump on an elevated bracket and performs a complete commissioning with refrigerant checks, vibration isolation, and clearance verification.

By AirGreen Climatisation & Chauffage Admin17 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
17 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a Samsung WindFree™ MaxHeat wall-mounted heat pump in Montréal-Nord
Installation of a Samsung WindFree™ MaxHeat wall-mounted heat pump in Montréal-Nord
The full story

The article, chapter by chapter

Complete technical commissioning in a narrow outdoor space, with refrigeration circuit checks and vibration protection

This Samsung WindFree™ MaxHeat wall-mounted heat pump installation in Montréal-Nord illustrates a stage that homeowners rarely see: the technical commissioning of the outdoor unit before the construction site is completely closed up.

In the photo, the rear coil of the heat pump is fully visible. A set of gauges is connected to the refrigeration circuit, while the service hoses allow our technician to check the equipment’s operating conditions. The unit rests on a raised aluminum support in a particularly narrow outdoor passage between a brick wall and a metal railing.

This configuration required precise planning. The space had to remain accessible, the coil had to be able to draw in enough air, vibrations had to be limited, and the refrigerant connections had to be tested methodically before final commissioning.

The result therefore depends not only on choosing a Samsung heat pump suited to Quebec’s climate. It also depends on the quality of every invisible step: preparing the lines, ensuring the connections are leak-tight, performing evacuation, checking the electrical system, monitoring pressures, and validating operation in both heating and cooling modes.

What this construction-site photo actually shows

The photograph was taken during the final procedures of the HVAC installation. The rear protective panel has been removed or opened to provide visual access to the coil and the components required for inspection.

Several technical elements are clearly visible:

  • the finned outdoor coil;
  • the network of refrigerant lines;
  • the manifold gauge set connected to the system;
  • the service hoses;
  • the raised metal support;
  • the anti-vibration pads placed beneath the unit;
  • the electrical disconnect installed on the brick wall;
  • the clearance maintained between the heat pump and the railing;
  • the concrete surface used as a stable base.

This image represents a decisive moment in the project. A heat pump can be perfectly straight and aesthetically well installed, but its performance depends first and foremost on the quality of the refrigeration circuit and the precision of its commissioning.

At AirGreen, we do not consider an installation complete simply because the indoor and outdoor units have been secured. The system must be checked, tested, and observed in its various modes before being handed over to the owner.

Why the Samsung WindFree™ MaxHeat was suitable for the building

The Samsung WindFree™ MaxHeat range is designed for homeowners seeking an appliance that can cool efficiently in summer and continue heating during cold periods.

Depending on the capacity and the exact combination of the indoor and outdoor units, some systems in this series can operate in heating mode down to approximately -30 °C. This feature is particularly relevant in Montréal-Nord, where winter temperatures can create a high heating demand for several consecutive days.

In a 12,000 BTU configuration, certain Samsung WindFree™ MaxHeat combinations can offer performance of up to approximately 24 SEER2, with a certified reference such as AHRI 215399291 for a specific combination.

However, it remains essential to check the complete model numbers. The name WindFree™ MaxHeat refers to a family of appliances with different capacities. Performance, low-temperature heating capacity, and eligibility for financial incentives must always be confirmed based on the actual combination installed.

WindFree™ technology and its benefits in a Montréal home

WindFree™ technology primarily affects how the indoor unit maintains the temperature.

When rapid cooling is needed, the unit uses its main louver to move a large volume of air. Once the desired temperature is reached, the appliance can diffuse air through the many micro-openings on its front panel.

This method helps reduce the sensation of a concentrated stream of cold air in a single direction. It is useful when the indoor unit is located:

  • in a bedroom;
  • near a sofa;
  • above a workspace;
  • in a narrow room;
  • facing a frequently occupied area.

The heat pump therefore maintains comfort with more discreet airflow. This feature does not replace proper positioning, but it significantly improves the daily experience when the unit must be installed in a room where occupants are close to the appliance.

A narrow outdoor location between the brick and the railing

The main challenge of this installation in Montréal-Nord was the limited width of the available space.

The outdoor unit is located between a brick wall and a guardrail. This arrangement imposes several constraints:

  • maintain access to the valves and service panels;
  • prevent the coil from being too close to the wall;
  • keep the air outlet unobstructed;
  • allow future cleaning of the outdoor coil;
  • reduce vibration transmission;
  • protect the piping and wiring;
  • preserve reasonable passage clearance.

A heat pump installed too close to an obstruction may recirculate the air it has just discharged. In summer, the unit may then draw in warmer air again. In winter, it may draw in colder, more humid air again, reducing its efficiency and promoting frost buildup.

In this project, the equipment was positioned to make use of the available space while maintaining the clearances required for operation and servicing.

Why the unit was elevated

The wall-mounted heat pump rests on an aluminum support secured to the concrete surface. This structure keeps the unit above the ground and provides it with a stable base.

Elevation plays an important role during winter. In heating mode, a heat pump must regularly defrost its outdoor coil. During this cycle, accumulated ice melts and produces water beneath the unit.

If the unit is placed directly on the ground, this water can refreeze around its base. Over successive cycles, a block of ice can form and reach the underside of the cabinet.

An elevated support allows you to:

  • improve drainage beneath the unit;
  • limit contact with snow;
  • prevent the base from sitting in water;
  • make cleaning easier;
  • keep the unit more accessible;
  • reduce the risk of blockage around the defrost drain.

However, the height must be adapted to the location. A structure that is too high can become unstable or transmit more vibrations if it is not properly sized and secured.

The role of the visible anti-vibration pads under the unit

Isolators are placed between the heat pump and the metal support. These small components play an important role in a residential installation.

A variable-speed compressor generally operates quietly, but it still produces slight vibrations. These can be transmitted to the support, concrete, wall, or guardrail when the unit is installed without mechanical isolation.

In some buildings, a vibration that is barely perceptible outside can become a humming sound indoors. This phenomenon is especially common when a metal structure acts as a sound box.

Anti-vibration pads help to:

  • decouple the unit from the support;
  • absorb some of the vibrations;
  • reduce structural noise;
  • protect the mounting points;
  • improve acoustic comfort.

However, their effectiveness depends on their positioning, load, and the overall rigidity of the support.

The electrical disconnect installed near the heat pump

To the left of the unit, on the brick wall, we can see an outdoor electrical box. This is the disconnecting means used to isolate power to the heat pump near the unit.

This component is essential for technician safety. During maintenance or repairs, the power supply must be able to be disconnected locally before the cabinet is opened.

The electrical installation must match the data on the nameplate, including:

  • the supply voltage;
  • the minimum circuit ampacity;
  • the maximum permitted protection;
  • the conductor gauge;
  • the required circuit breaker type;
  • grounding requirements.

These values should not be estimated solely based on the nominal capacity in BTUs. Two heat pumps with the same capacity may require different electrical protection.

What the gauges are used for during commissioning

The manifold gauge set visible in the center of the photo allows the technician to observe the behavior of the refrigeration circuit.

However, pressures must never be interpreted on their own. They vary according to:

  • outdoor temperature;
  • indoor temperature;
  • operating mode;
  • compressor speed;
  • fan speed;
  • the home’s thermal load;
  • the type of refrigerant;
  • the time elapsed since startup.

On a variable-speed heat pump, the readings change continuously according to demand. It would therefore be incorrect to add or remove refrigerant solely because a pressure appears different from a value observed on another system.

Our technicians consider all available data: temperatures, pressures, line length, manufacturer specifications, electrical current, and the machine’s behavior.

Evacuation: an invisible but essential step

Before opening the service valves and releasing the outdoor unit’s refrigerant charge into the lines, the circuit must be evacuated.

This procedure removes:

  • air;
  • moisture;
  • non-condensable gases;
  • some of the contaminants present in the lines.

Moisture poses a serious risk to the compressor and refrigeration oil. It can contribute to acid formation, degradation of the internal insulation, and reduced system reliability.

A simple refrigerant purge does not replace proper evacuation. A quick installation that neglects this step may work initially but develop problems after a few months or years.

Flare fittings and the risk of leaks

Wall-mounted heat pumps generally use flare fittings to connect the copper lines to the indoor and outdoor units.

The quality of these fittings depends on several precise steps:

  1. cut the copper at a right angle;
  2. remove burrs without contaminating the pipe;
  3. place the nut before making the flare;
  4. form an even flare;
  5. properly align the fitting;
  6. tighten the nut to the recommended torque;
  7. perform a leak test.

A fitting that is too loose can leak. A fitting that is too tight can crack the copper or deform the flare.

A slow leak is not always detected immediately. The system may gradually lose capacity, run longer, frost over, or stop with an error code. In more severe cases, the compressor may be damaged.

Nitrogen testing before startup

When required by the site procedure, a dry-nitrogen pressure test verifies the circuit’s leak-tightness before evacuation.

Nitrogen is used because it is dry, stable, and non-condensable. It allows the system to be pressurized without introducing moisture.

During this step, we inspect in particular:

  • flare fittings;
  • service valves;
  • brazed joints, where applicable;
  • connections near the indoor unit;
  • lines that have undergone a sharp bend.

The pressure must remain stable throughout the specified observation period. Any drop must be analyzed before commissioning.

Why refrigerant should not be added automatically

The outdoor unit generally arrives with a refrigerant charge intended for a specific line length. Additional refrigerant may be required when the length exceeds the amount included by the manufacturer.

This amount must be calculated precisely according to the technical instructions. Adding refrigerant “as a precaution” is a mistake.

An overcharge can cause:

  • abnormally high pressures;
  • excessive electricity consumption;
  • reduced efficiency;
  • protective shutdowns;
  • additional stress on the compressor.

An undercharge can lead to:

  • loss of capacity;
  • insufficient discharge-air temperature;
  • frost;
  • extended operating times;
  • compressor overheating.

The charge must therefore correspond to the equipment combination and the actual length of the lines.

An outdoor heat exchanger that must remain clean and unobstructed

The green heat exchanger visible in the photo contains many thin metal fins. Their role is to transfer heat between the refrigerant and the outdoor air.

These fins can accumulate:

  • dust;
  • pollen;
  • leaves;
  • plant debris;
  • lint;
  • dirt carried by rain.

In a narrow passage like this one, it is important to periodically check the back of the unit. Dirt buildup reduces airflow and forces the heat pump to work harder.

Cleaning must be performed using a suitable method. A water jet that is too powerful can bend the fins. Corrosive products can damage their coating.

During professional HVAC maintenance, we can clean the coil, inspect the connections, check the drains, and confirm the system’s overall operation.

Protecting the unit during winter

A heat pump should not be covered like an unused air conditioner. It must be able to draw in and expel air throughout the heating season.

The owner should instead:

  • remove accumulated snow around the unit;
  • keep the top clear;
  • do not push snow against the coil;
  • make sure the defrost water can drain;
  • avoid using metal tools to remove ice;
  • never pour boiling water over the unit.

Some frost is normal in heating mode. The system then initiates a defrost cycle. For a few minutes, the outdoor fan may stop and steam may appear. This does not indicate a malfunction.

A thick layer of ice that remains after several cycles should, however, be inspected.

Sizing a heat pump for a Montréal-Nord home

The BTU capacity must be selected based on the characteristics of the home, not solely on its area.

We assess in particular:

  • the quality of the insulation;
  • the number of exterior walls;
  • windows;
  • the building’s orientation;
  • air leaks;
  • ceiling height;
  • the layout of the rooms;
  • sun exposure;
  • how the space is used;
  • the presence of supplementary heating.

An oversized unit may short-cycle and control humidity less effectively. An undersized unit may run continuously without maintaining the temperature during extreme conditions.

In duplexes, triplexes, and other common buildings in Montréal-Nord, airflow between rooms must also be considered. A single wall-mounted unit may adequately serve an open-concept area, but it will not necessarily distribute the same amount of heat behind several closed doors.

Potential eligibility for financial assistance

Certain Samsung WindFree™ MaxHeat heat pump combinations may be eligible for rebate programs offered in Quebec.

Eligibility depends in particular on:

  • the exact models installed;
  • the AHRI reference;
  • the recognized low-temperature capacity;
  • the applicable certification;
  • the type of building;
  • the purchase and installation date;
  • the program conditions at the time of application.

The series name does not automatically guarantee a rebate. The exact combination shown on the invoice and nameplates must be verified.

We also recommend keeping:

  • the detailed invoice;
  • proof of payment;
  • the serial numbers;
  • photos of the nameplates;
  • the AHRI reference;
  • the documentation provided after installation.

Mistakes to avoid when installing a unit in a narrow passageway

Locations like the one shown may give the impression that all you need to do is fit the unit into the available space. This approach often leads to problems.

The most common mistakes are:

  1. placing the coil too close to the wall;
  2. pointing the fan directly at an obstacle;
  3. making the service valves inaccessible;
  4. installing the unit directly on the concrete;
  5. forgetting anti-vibration isolators;
  6. blocking part of the passageway;
  7. neglecting the drainage of defrost water;
  8. placing the disconnect in a difficult-to-access location;
  9. compressing or excessively bending the lines;
  10. failing to allow enough space for cleaning.

A professional installation takes future servicing into account from the first visit. The unit should not only work today; it should also be serviceable and repairable without unnecessary disassembly.

The AirGreen result: a heat pump inspected before being handed over to the homeowner

This Samsung WindFree™ MaxHeat installation in Montréal-Nord combines equipment suited to the cold climate with an installation designed for a restricted outdoor space.

The raised stand protects the unit from water and ice buildup. The pads help limit vibrations. The electrical disconnect provides an accessible shutoff point. Clearances were planned to preserve airflow and facilitate maintenance.

The presence of the gauges in the photo mainly shows that our work does not stop at securing the unit. The refrigeration circuit is checked, operating conditions are analyzed, and connections are inspected before the job is completed.

For the homeowner, this means an installation designed to provide:

  • effective cooling on hot days;
  • high-performance heating during the winter;
  • gentler comfort thanks to WindFree™ technology;
  • variable-speed operation;
  • greater peace of mind;
  • reasonable access for future maintenance.

At AirGreen, we carry out wall-mounted heat pump installations in Montréal-Nord, throughout Montréal, as well as in Laval, Longueuil, on the North Shore, and on the South Shore. Each project is adapted to the building, the available space, and the occupants’ actual needs.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).