ZU1 · 24,000 BTU
Indoor AY-XP24ZU1 · outdoor AE-X24ZU1
AHRI certificate 213246054 · NEEP 507395
The model installed in Montréal-Est.
See the product pageA 24,000 BTU SHARP ZU1 installed in a Montréal-Est home. The project, then the BOSCH Climate 5000 MAX PERFORMANCE R-454B: what the 24,000 BTU figure covers in each certificate, deep cold, installation and estimated electricity cost.

In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
In Montréal-Est, AirGreen installed a 24,000 BTU SHARP ZU1. The BOSCH Climate 5000 MAX PERFORMANCE R-454B carries the same figure in its name. Yet their AHRI certificates do not give 24,000 BTU/h in the same places: this page shows where, condition by condition. Neither one is ranked.

Indoor AY-XP24ZU1 · outdoor AE-X24ZU1
AHRI certificate 213246054 · NEEP 507395
The model installed in Montréal-Est.
See the product page
Indoor BMS500-AAU024-1AHWXD · outdoor BMS500-AAS024-1CSXHD
AHRI certificate 215223290 · NEEP 392013
Climate 5000 series, 4th generation; R-454B refrigerant.
See the product pageAirGreen product cards; the grant and certification badges are masked. The SHARP ZU1 uses R-32, the BOSCH MAX PERFORMANCE uses R-454B, both A2L class refrigerants. Values in BTU/h, AHRI certificates published by NEEP.
AirGreen estimate for a 24,000 BTU/h home in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated at 24,000 BTU/h, the number in their name, with their certified seasonal efficiencies; electric baseboards give the point of comparison.
AirGreen method v1.1, November 9, 2026. It is used to compare two units under the same conditions; a real bill depends on the home, insulation, settings and use. It is not a promise.
For this Montréal-Est home, the owners wanted one unit to heat in winter and cool in summer. AirGreen installed a 24,000 BTU SHARP ZU1 wall heat pump.
The indoor unit sits high on the wall, near the corner, just below the ceiling, in a room with light walls, a light wood floor and dark curtains.
A unit sold as “24,000 BTU” does not deliver 24,000 BTU/h in every condition. According to its certificate, the ZU1 gives 22,000 BTU/h rated in cooling at 35 °C and 24,000 BTU/h rated in heating at 8.3 °C. The BOSCH Climate 5000 MAX PERFORMANCE R-454B, also sold as 24,000 BTU, is the point of comparison: same type, same number in the name, other values on the certificate.

Pick a test condition from the AHRI certificate. The dotted line marks 24,000 BTU/h, the number in the name. The solid bar is the certified rated capacity, the pale part runs up to the maximum capacity, and the thin tick marks the minimum capacity.
Both certificates stop at −15 °C, except for one last colder point: −27.2 °C for the ZU1, −30 °C for the BOSCH MAX PERFORMANCE. In between, the SHARP brochure publishes maximum capacities at −20 and −25 °C, and the BOSCH submittal sheet a table of total heating capacity.
Only the features named in the SHARP ZU/ZHU brochure, its installation manual, the BOSCH 24K MAX PERFORMANCE submittal sheet and the BOSCH Climate 5000 Gen 4 service manual are listed. When a document does not mention a feature, that is stated; the silence does not prove the unit lacks it.
SHARP ZU1 The SHARP brochure limits the motion-sensor options to the ZHU series. The 24,000 BTU ZU1 is part of the ZU series.
BOSCH MAX PERFORMANCE Not stated in the documents consulted.
SHARP ZU1 Coanda airflow and the Multi Space function; automatic vertical vane, manual horizontal direction, per the brochure's 24,000 column.
BOSCH MAX PERFORMANCE Louver position memory; “Breeze Away” available as an option, per the service manual.
SHARP ZU1 Built-in Wi-Fi on every unit in the series, per the brochure.
BOSCH MAX PERFORMANCE Wi-Fi phone control available as an option, per the service manual; remote supplied per the submittal sheet.
SHARP ZU1 Not stated in the documents consulted.
BOSCH MAX PERFORMANCE Turbo, “ECO Intelligent” and humidity control documented; Follow Me and quiet mode as options; timer and sleep mode.
SHARP ZU1 Self-cleaning and Plasmacluster functions: the page gives the names of the functions, not the claimed effects.
BOSCH MAX PERFORMANCE “Active Clean” function, per the service manual.
SHARP ZU1 Not stated in the brochure consulted.
BOSCH MAX PERFORMANCE Refrigerant leak detection documented in the service manual.
SHARP ZU1 Not stated in the documents consulted.
BOSCH MAX PERFORMANCE 8 °C (46.4 °F) heating, an option per the service manual.
SHARP ZU1 HOT GAS PIPE system (anti-freeze, defrost), per the brochure.
BOSCH MAX PERFORMANCE Auto defrost; 150 W base pan heater per the NEEP record.
SHARP ZU1 Automatic restart after a power outage.
BOSCH MAX PERFORMANCE Auto restart documented in the service manual.
The published levels for each indoor-unit speed, then the outdoor unit's level.
SHARP: five speeds (Sh, H, M, B, Sb), heating, measurement method not stated in the brochure. BOSCH: five steps (Turbo, High, Med, Low, Silent), submittal sheet, method not described.
SHARP: 54 dB in heating, 53 dB in cooling, method not stated. BOSCH: 61.5 dB(A) maximum, method not described.
How to read these figures. Each dot repeats a level published for one speed. The dB(A) scale is logarithmic: 3 dB more is about twice the sound energy. A lower figure means a quieter unit at that speed, not necessarily over the whole day.
Why this is not a ranking. Neither SHARP nor BOSCH describes how its levels are measured. Without a known method, the values cannot be compared decibel for decibel: method not stated — not comparable.
Each manufacturer measures with its own method; the figures give an order of magnitude, not a ranking.
Dimensions, weights, piping and electrical protection, as published by each manufacturer. The indoor units are shown to the scale of their width.


Cabinet width only. The clearances needed on each side are in each model's installation manual.
| Published data | SHARP ZU1 | BOSCH MAX PERFORMANCE |
|---|---|---|
| Maximum piping length | 65.6 ft (20 m)ZU/ZHU/BU installation manual, EN-2 | 164 ft (50 m)BOSCH 24K submittal sheet |
| Pre-charged length | 25 ft (7.6 m)Beyond that: 0.16 oz/ft | 24.6 ft (7.5 m)Beyond that: 0.32 oz/ft |
| Maximum height difference | 32.8 ft (10 m) | 82 ft (25 m) |
| Liquid – gas diameters | 1/4 – 3/8 in | 3/8 – 5/8 in |
| Indoor unit W × H × D, weight | 41 27/64 × 12 7/16 × 9 51/64 in, 31 lb | 44.88 × 14.57 × 10.83 in, 43.65 lb |
| Outdoor unit W × H × D, weight | 33 15/32 × 27 15/16 × 13 in, 95 lb | 37.24 × 31.89 × 16.14 in, 130.29 lb |
| Power supply | 208-230 V, single phase, 60 Hz | 208-230 V, single phase, 60 Hz |
| Electrical protection | 20 A circuit breakerInstallation manual, EN-6, AE-X24ZU(1); the brochure prints a 25 A max. fuse | Outdoor: MCA 24.9 A, max. fuse 25 AIndoor: MCA 3 A, max. fuse 15 A; submittal sheet |
| Airflow | 752 cfm at the highest speed, heating | 812.3 cfm at the Turbo step |
| Dehumidification | 6.8 pints/h | 5.7 pints/h |
| Advertised heating / cooling range | −27 to 24 °C / −10 to 46 °C | −30 to 24 °C / −30 to 50 °C |
| Fan speeds | 5 speeds (Sh, H, M, B, Sb) | 5 published steps (Turbo, High, Med, Low, Silent) |
Values from the manufacturers' documents. The two units do not use the same pipe diameters: each installation follows the manual of the model installed.
Because both are wall heat pumps sold by AirGreen under the same figure, 24,000 BTU, and their certificates do not place that figure at the same test conditions. This choice is not a ranking.
Because the page compares published values, not units installed in your home. Every SHARP ZU1 and BOSCH MAX PERFORMANCE figure comes with its source and conditions; “higher” is only used when the measure and conditions are the same.
The SHARP brochure prints a rated capacity of 24,000 BTU/h in heating and 22,000 BTU/h in cooling. AHRI certificate 213246054 gives the same values: 24,000 BTU/h at 8.3 °C in heating, 22,000 BTU/h at 35 °C in cooling. The 24,000 in the name therefore matches the rated heating capacity.
Its AHRI certificate 215223290 gives 24,000 BTU/h rated in cooling at 35 °C and 29,000 BTU/h rated in heating at 8.3 °C. The BOSCH submittal sheet repeats both values.
No. SHARP specifies 1/4 and 3/8 in lines for the ZU1; BOSCH specifies 3/8 and 5/8 in for the 24K MAX PERFORMANCE. Maximum lengths and the charge to add beyond the pre-charged length also differ.
No. The SHARP ZU1 uses R-32 (GWP 675) and the BOSCH MAX PERFORMANCE uses R-454B (GWP 466), per the IPCC's 4th report. Both are class A2L per ASHRAE 34.
Eligibility is checked model by model in Hydro-Québec's official list in force at the time of purchase; it can change. No amount is given on this page.
| Value | SHARP ZU1 | BOSCH MAX PERFORMANCE |
|---|---|---|
| Certificate | ||
| AHRI certificate · NEEP record | 213246054 · NEEP 507395 | 215223290 · NEEP 392013 |
| Refrigerant | R-32 · GWP 675 (IPCC AR4) · class A2L | R-454B · GWP 466 (IPCC AR4) · class A2L |
| ENERGY STAR | NEEP record: ENERGY STAR box unchecked, cold climate box checked | Yes, cold climate included (NEEP) |
| Seasonal efficiency | ||
| SEER2 | 22 | 21 |
| EER2 | 10 | 13 |
| HSPF2 region IV | 11 | 13.5 |
| HSPF2 region V | 8.5 | 9.8 |
| Heating at 8.3 °C (47 °F) | ||
| Capacity min. / rated / max. | 5,500 / 24,000 / 27,100 BTU/h | 11,800 / 29,000 / 29,700 BTU/h |
| COP min. / rated / max. | 5.76 / 3.86 / 3.37 | 5.09 / 3.41 / 3.39 |
| Heating at −8.3 °C (17 °F) | ||
| Capacity min. / rated / max. | 7,500 / 22,400 / 22,400 BTU/h | 11,500 / 22,200 / 23,200 BTU/h |
| COP min. / rated / max. | 3.38 / 2.34 / 2.34 | 2.26 / 2.88 / 2.35 |
| Heating at −15 °C (5 °F) | ||
| Capacity min. / rated / max. | 5,800 / 19,000 / 19,000 BTU/h | 9,300 / 24,200 / 24,200 BTU/h |
| COP min. / rated / max. | 2.93 / 2.20 / 2.20 | 1.96 / 2.34 / 2.34 |
| Coldest certified point | ||
| Test temperature | −27.2 °C (−17 °F) | −30 °C (−22 °F) |
| Capacity min. / max. | 3,200 / 12,300 BTU/h | 2,400 / 11,900 BTU/h |
| COP min. / max. | 2.04 / 1.82 | 0.98 / 1.45 |
| Cooling at 35 °C (95 °F) | ||
| Rated capacity at 35 °C: min. / rated / max. | 6,000 / 22,000 / 23,000 BTU/h | 12,600 / 24,000 / 27,900 BTU/h |
| COP min. / rated / max. | 5.67 / 2.93 / 2.58 | 3.93 / 3.80 / 3.59 |
“higher” marks the higher value of the same measure under the same conditions. It is not a recommendation.
On airgreen.ca, the 24,000 BTU SHARP ZU1 and BOSCH Climate 5000 MAX PERFORMANCE each have their product page and documents. A home to heat and cool, as in Montréal-Est? Call us or request an estimate.
Data verified on November 17, 2026. Certified values come from the AHRI certificates published by NEEP; declared values come from the manufacturers' documents cited. The cost is an AirGreen estimate whose method is described above.
SHARP, BOSCH and the other brands mentioned belong to their owners. Logos and images identify the products. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca.
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Three habits per season for this unit. They take a few minutes and prevent many calls.
Pick what looks like your need.
Flip each card to see what we do instead.
No question matches. Write to us: we answer.
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).