ZU1 · 18,000 BTU
Indoor AY-XP18ZU1 · outdoor AE-X18ZU1
AHRI certificate 213246053 · NEEP 507396
The model installed in Kirkland.
See the product pageAn 18,000 BTU SHARP ZU1 in the living area of a Kirkland family home. The project, then the same-size ZEPHYR Series 25 R-454B: published sound at each speed, features, deep cold and estimated electricity cost.

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp ZU1 12 000 | 14,500 | 12,000 | −27 °C: 7,200 | 2.11 | 22.0 | 11.0 | $1,740 |
| Sharp ZU1 15 000 | 18,100 | 15,300 | −27 °C: 10,100 | 2.1 | 24.0 | 11.0 | $2,172 |
| Sharp ZU1 18 000 | 22,000 | 18,000 | −27 °C: 11,500 | 2.2 | 24.0 | 11.0 | $2,640 |
| Sharp ZU1 24 000 | 22,400 | 19,000 | −27 °C: 12,300 | 2.2 | 22.0 | 11.0 | $2,688 |
According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.
At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.
According to NEEP, it delivers 18,100 BTU/h at −8 °C (17 °F), more than at 8 °C (18,000 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 10,100 BTU/h, 67% of its nominal 15,000 BTU size.
At 8 °C, its certified maximum capacity reaches 21,800 BTU/h, 45% more than its nominal 15,000 BTU size.
According to NEEP, it delivers 22,000 BTU/h at −8 °C (17 °F), more than at 8 °C (21,600 BTU/h). It heats as hard in moderate cold as in mild weather.
According to NEEP, its COP at −27 °C is 1.88: the highest of the ZU1 line, which ranges from 1.79 to 1.82 at that temperature.
According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 11,500 BTU/h, 64% of its nominal 18,000 BTU size.
At −27 °C, its certified minimum capacity is 3,200 BTU/h (5,500 at 8 °C). It slows down instead of cycling on and off.
According to NEEP, its certified heating capacity at −15 °C (5 °F) is 19,000 BTU/h, 79% of its nominal 24,000 BTU size. Its COP there is 2.20.
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
In Kirkland, AirGreen installed an 18,000 BTU SHARP ZU1 in the living area of a home with children and pets. In a room like that, the unit runs from morning to night. Here is that project, then the same-size ZEPHYR Series 25: what each manufacturer publishes about sound, modes and upkeep. Neither one is ranked.

Indoor AY-XP18ZU1 · outdoor AE-X18ZU1
AHRI certificate 213246053 · NEEP 507396
The model installed in Kirkland.
See the product page
Indoor ZE-18CB25I · outdoor ZE-18CB25O
AHRI certificate 215414831 · NEEP 418301
HiULTRA series at NEEP; R-454B refrigerant.
See the product pageAirGreen product cards; the grant, certification and component badges are masked. The SHARP ZU1 uses R-32, the ZEPHYR Series 25 uses R-454B, both A2L class refrigerants. Values in BTU/h, AHRI certificates published by NEEP.
For an 18,000 BTU/h living area in Montréal, here is the estimated electricity per season, at Hydro-Québec Rate D, taxes included. Set the heating and cooling hours to the household's habits: only the certified efficiencies set the two units apart in this calculation. Benchmark: electric baseboards.
AirGreen method v1.1 (November 9, 2026). Same calculation for both units, so they can be compared; a family's bill depends on its home, insulation, settings and habits. This amount is not a promise.
The family wanted one unit to heat and cool the living area, where meals, homework and evenings happen. The children and pets spend the day there. AirGreen installed an 18,000 BTU SHARP ZU1 wall heat pump.
The indoor unit sits high on the papered wall between two windows. In a room used from morning to night, the unit often runs at low speed: the sound published at each speed matters as much as capacity.
The 18,000 BTU ZEPHYR Series 25 is the point of comparison: same type, same nominal size, R-454B refrigerant, and its brochure publishes the sound of five speeds.

Pick the mode and the speed: the diagram shows the indoor unit's published sound level at that speed, in a living area. The circles grow with the number of decibels.
Below −15 °C, each certificate publishes just one more value: at −27.2 °C for the ZU1 and at −25 °C for the ZEPHYR Series 25. The SHARP brochure also publishes maximum capacities at −20 and −25 °C. For ZEPHYR, the page shows the range between its two certified points, then its last published value.
Only the features named in the SHARP ZU/ZHU brochure, its installation manual and the ZEPHYR 25 R-454B series brochure are listed. A silent document is flagged as such; that does not prove the unit lacks the feature.
SHARP ZU1 Not offered on the ZU1: according to the brochure, SHARP keeps the motion-sensor options for the ZHU series.
ZEPHYR Series 25 Not stated in the documents consulted.
SHARP ZU1 Coanda airflow with a long vane, and the Multi Space function, per SHARP. Four-way swing is not mentioned in the SHARP documents consulted.
ZEPHYR Series 25 Horizontal and vertical auto swing (“4D airflow”) and louver position memory.
SHARP ZU1 Not stated in the documents consulted.
ZEPHYR Series 25 Quiet and sleep modes, 24-hour timer.
SHARP ZU1 Built-in Wi-Fi on every unit in the series, per the brochure.
ZEPHYR Series 25 Wi-Fi is not mentioned in the brochure; wireless remote with backlit screen.
SHARP ZU1 Plasmacluster cleaning function: the page gives the function's name, not the claimed effects.
ZEPHYR Series 25 Auto cleaning; the filters are not described in the brochure.
SHARP ZU1 Not stated in the documents consulted.
ZEPHYR Series 25 Automatic 8 °C (46 °F) heating.
SHARP ZU1 RAPID DEFROST and DEFROST modes; HOT GAS PIPE system with multiple drain holes and PRE-WARM.
ZEPHYR Series 25 Auto defrost; electric heater in the outdoor chassis, 200 W per the NEEP record.
SHARP ZU1 Automatic restart after a power outage.
ZEPHYR Series 25 Auto restart, per the brochure.
The published levels for each indoor-unit speed, then the outdoor unit's level.
SHARP: five speeds (Sh, H, M, B, Sb), heating, measurement method not stated in the brochure. ZEPHYR: five values, from highest to lowest, mode and method not stated.
SHARP: 52 dB(A) in heating, method not stated. ZEPHYR: 58 dB, method not stated.
How to read these figures. A dot is a fan speed, with the level the manufacturer publishes. dB(A) reads on a logarithmic scale: 3 dB more is about twice the sound energy. In a living area, it is mostly the low speeds, the evening and night ones, that you hear for hours.
Why this is not a ranking. Neither SHARP nor ZEPHYR states how its levels are measured. Without a known method, the values cannot be compared decibel for decibel: method not stated — not comparable.
Each manufacturer measures with its own method; the figures give an order of magnitude, not a ranking.
Dimensions, weights, piping and electrical protection, as published by each manufacturer. The indoor units are shown to the scale of their width.


Cabinet width only. The clearances needed on each side are in each model's installation manual.
| Published data | SHARP ZU1 | ZEPHYR Series 25 |
|---|---|---|
| Maximum piping length | 65.6 ft (20 m)ZU/ZHU/BU installation manual, EN-2 | Length not stated in the series brochure |
| Pre-charged length | 25 ft (7.6 m)Beyond that: 0.16 oz/ft | Length not stated in the series brochure |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 1/2 in |
| Indoor unit W × H × D, weight | 41 27/64 × 12 7/16 × 9 51/64 in, 31 lb | 43 5/16 × 12 13/16 × 9 5/8 in, 14.5 kg (32 lb) |
| Outdoor unit W × H × D, weight | 33 15/32 × 27 15/16 × 13 in, 95 lb | 33 7/8 × 25 9/16 × 12 3/16 in, 44 kg (97 lb) |
| Power supply | 208-230 V, single phase, 60 Hz | 208/230 V, single phase, 60 Hz |
| Electrical protection | 20 A circuit breakerInstallation manual, EN-6; the brochure prints a 25 A max. fuse | MCA 11.5 A, MOP 15 AZEPHYR 25 R-454B series brochure |
| Airflow | 752 cfm at the highest speed, heating | 1,100 m³/h (about 647 cfm), speed not stated |
| Advertised heating / cooling range | −27 to 24 °C / −10 to 46 °C | Down to −30 °C / down to −15 °CSeries brochure statements |
| Fan speeds | 5 speeds (Sh, H, M, B, Sb) | 7 speeds advertised; sound published for 5 |
Values from the manufacturers' documents. The piping lengths of the 18,000 BTU ZEPHYR are not in the series brochure; they are confirmed in the exact model's installation manual.
Because a family equipping its living area looks at units of the same type and size, and the ZEPHYR brochure publishes the sound of five speeds, like SHARP. The 18,000 BTU ZEPHYR Series 25 is sold by AirGreen. This choice is not a ranking.
No. The ZU1 and ZEPHYR Series 25 values are shown next to each other, each with its document and test conditions. The “higher” marker only appears for the same measure taken under the same conditions.
No, according to the SHARP ZU/ZHU brochure: the motion-sensor options are only available on the ZHU series. The ZU1 installed in Kirkland belongs to the ZU series. The ZEPHYR brochure consulted does not mention one either.
The SHARP documents consulted describe Coanda airflow with a long vane and a Multi Space function; they do not mention four-way swing. The ZEPHYR brochure, for its part, advertises horizontal and vertical auto swing.
The brochures publish 25 dB(A) for the ZU1's lowest speed in heating and 36 dB for the ZEPHYR's lowest value. Neither states its measurement method: these figures give an order of magnitude, they do not let us name the quieter one.
No. The SHARP ZU1 uses R-32 (GWP 675) and the ZEPHYR Series 25 uses R-454B (GWP 466), per the IPCC's 4th report. Both are class A2L per ASHRAE 34.
To find out, check Hydro-Québec's list of eligible units in force on the date of purchase, with the exact model number; the list changes. This page gives no amount.
| Value | SHARP ZU1 | ZEPHYR Series 25 |
|---|---|---|
| Certificate | ||
| AHRI certificate · NEEP record | 213246053 · NEEP 507396 | 215414831 · NEEP 418301 |
| Refrigerant | R-32 · GWP 675 (IPCC AR4) · class A2L | R-454B · GWP 466 (IPCC AR4) · class A2L |
| ENERGY STAR | Yes, cold climate included (NEEP) | Yes, cold climate included (NEEP) |
| Seasonal efficiency | ||
| SEER2 | 24 | 21 |
| EER2 | 13 | 12.95 |
| HSPF2 region IV | 11 | 10 |
| HSPF2 region V | 9 | 8.5 |
| Heating at 8.3 °C (47 °F) | ||
| Capacity min. / rated / max. | 5,500 / 21,600 / 25,600 BTU/h | 5,500 / 18,000 / 19,000 BTU/h |
| COP min. / rated / max. | 5.76 / 4.22 / 3.68 | 3.66 / 3.69 / 3.24 |
| Heating at −8.3 °C (17 °F) | ||
| Capacity min. / rated / max. | 7,500 / 22,000 / 22,000 BTU/h | 4,675 / 18,000 / 18,500 BTU/h |
| COP min. / rated / max. | 3.38 / 2.38 / 2.38 | 3.43 / 1.95 / 1.95 |
| Heating at −15 °C (5 °F) | ||
| Capacity min. / rated / max. | 5,800 / 18,000 / 18,000 BTU/h | 4,000 / 18,000 / 18,000 BTU/h |
| COP min. / rated / max. | 2.93 / 2.20 / 2.20 | 1.38 / 1.90 / 1.90 |
| Coldest certified point | ||
| Test temperature | −27.2 °C (−17 °F) | −25 °C (−13 °F) |
| Capacity min. / max. | 3,200 / 11,500 BTU/h | 2,000 / 11,500 BTU/h |
| COP min. / max. | 2.04 / 1.88 | 0.76 / 1.43 |
| Cooling at 35 °C (95 °F) | ||
| Rated capacity at 35 °C: min. / rated / max. | 6,000 / 18,000 / 21,600 BTU/h | 4,500 / 18,000 / 19,000 BTU/h |
| COP min. / rated / max. | 5.67 / 3.82 / 2.93 | 3.30 / 3.80 / 2.95 |
“higher” marks the higher value of the same measure under the same conditions. It is not a recommendation.
Each unit, the 18,000 BTU SHARP ZU1 and ZEPHYR Series 25, has its product page on airgreen.ca with its documents. A living area to heat and cool, as in Kirkland? Call us or request an estimate.
Data verified on November 17, 2026. Certified values come from the AHRI certificates published by NEEP; declared values come from the manufacturers' documents cited. The cost is an AirGreen estimate whose method is described above.
SHARP, ZEPHYR and the other brands mentioned belong to their owners. Logos and images identify the products. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca.
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Six simple habits that keep the unit going. Your list stays on this device.
Three habits per season for this unit. They take a few minutes and prevent many calls.
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
No question matches. Write to us: we answer.
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).