Job sheet · Project

Installing a SHARP ZU1 wall heat pump in Kirkland, compared with the ZEPHYR Series 25 (18,000 BTU)

An 18,000 BTU SHARP ZU1 in the living area of a Kirkland family home. The project, then the same-size ZEPHYR Series 25 R-454B: published sound at each speed, features, deep cold and estimated electricity cost.

By AirGreen Climatisation & Chauffage Admin15 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
15 minto read the whole story
–type of installation
2024year published
At a glance

The job on one screen

Installing a SHARP ZU1 wall heat pump in Kirkland, compared with the ZEPHYR Series 25 (18,000 BTU)
Installing a SHARP ZU1 wall heat pump in Kirkland, compared with the ZEPHYR Series 25 (18,000 BTU)
The unit

The unit’s data sheet

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

The full story

The article, chapter by chapter

Comparison · Wall heat pump · 18,000 BTU

A family living area, one 18,000 BTU wall unit: the SHARP ZU1 we installed and the ZEPHYR Series 25, figure by figure

In Kirkland, AirGreen installed an 18,000 BTU SHARP ZU1 in the living area of a home with children and pets. In a room like that, the unit runs from morning to night. Here is that project, then the same-size ZEPHYR Series 25: what each manufacturer publishes about sound, modes and upkeep. Neither one is ranked.

HSPF2 region V 9 · 8.5SEER2 24 · 21Lowest published speed 25 dB(A) · 36 dBColdest certified point 11,500 at −27.2 °C · 11,500 at −25 °C
AirGreen product card of the SHARP ZU1 18,000 BTU: indoor unit, outdoor unit and remote
SHARP

ZU1 · 18,000 BTU

Indoor AY-XP18ZU1 · outdoor AE-X18ZU1
AHRI certificate 213246053 · NEEP 507396

The model installed in Kirkland.

See the product page
AirGreen product card of the ZEPHYR Series 25 R-454B 18,000 BTU: indoor unit, outdoor unit and remote
ZEPHYR

Series 25 R-454B · 18,000 BTU

Indoor ZE-18CB25I · outdoor ZE-18CB25O
AHRI certificate 215414831 · NEEP 418301

HiULTRA series at NEEP; R-454B refrigerant.

See the product page

AirGreen product cards; the grant, certification and component badges are masked. The SHARP ZU1 uses R-32, the ZEPHYR Series 25 uses R-454B, both A2L class refrigerants. Values in BTU/h, AHRI certificates published by NEEP.

Estimated running cost

What the electricity costs, in dollars, winter and summer

For an 18,000 BTU/h living area in Montréal, here is the estimated electricity per season, at Hydro-Québec Rate D, taxes included. Set the heating and cooling hours to the household's habits: only the certified efficiencies set the two units apart in this calculation. Benchmark: electric baseboards.

How this amount is calculated
  1. How much heat over a winter. The calculation assumes a living area whose heat loss reaches 18,000 BTU/h (5.28 kW) at −23.1 °C, Montréal's design temperature. Heated around the clock through a winter of 4,167 degree-days (base 18 °C; Natural Resources Canada, HOT2000, Montréal Intl station), it needs 5.28 kW × 24 h × 4,167 ÷ (18 − (−23.1)) = 12,838 kWh of heat. Fewer hours on the "Heating" slider means less heat, in the same proportion for both heat pumps and for the baseboards. Warming back up after a night setback is not part of this simplified calculation.
  2. What the heat pump uses for heating. kWh of heat × 3.412 ÷ HSPF2 region V, the AHRI certificate value published by NEEP. Region V is the coldest zone in the standard, and electric backup is included. Benchmark: baseboards turn 1 kWh of electricity into 1 kWh of heat.
  3. What it uses for cooling. Hydro-Québec air-conditioning calculator formula: 18,000 ÷ SEER2 × hours per day × 60 days ÷ 1,000, with the certificate's SEER2. Hours are set from 1 to 24; at 24 h, rated capacity is assumed nonstop, a maximum, since the unit slows down once the room has cooled.
  4. The price. Hydro-Québec Rate D as of April 1, 2026: 7.065¢ per kWh for the first 40 kWh of the day, 11.142¢ for the rest, 9.104¢ on average (the value in Hydro-Québec's calculators), GST and QST included. Network access charges do not change with the heat pump and are not counted.

AirGreen method v1.1 (November 9, 2026). Same calculation for both units, so they can be compared; a family's bill depends on its home, insulation, settings and habits. This amount is not a promise.

The project

Kirkland: the wall unit in the room where everyone lives

The family wanted one unit to heat and cool the living area, where meals, homework and evenings happen. The children and pets spend the day there. AirGreen installed an 18,000 BTU SHARP ZU1 wall heat pump.

The indoor unit sits high on the papered wall between two windows. In a room used from morning to night, the unit often runs at low speed: the sound published at each speed matters as much as capacity.

The 18,000 BTU ZEPHYR Series 25 is the point of comparison: same type, same nominal size, R-454B refrigerant, and its brochure publishes the sound of five speeds.

LocationKirkland, West Island
RoomThe living area of a family home, with children and pets
RequestHeat and cool the room where the family spends its days
UnitSHARP ZU1 18,000 BTU · AY-XP18ZU1 / AE-X18ZU1 · AHRI certificate 213246053
Indoor unitHigh on the papered wall, between two windows
SHARP ZU1 indoor unit mounted high on a papered wall, between two windows, in the living area of a Kirkland home
AirGreen photo of the Kirkland job.
In the living area

What each manufacturer publishes, speed by speed

Pick the mode and the speed: the diagram shows the indoor unit's published sound level at that speed, in a living area. The circles grow with the number of decibels.

Read this before drawing conclusions. SHARP publishes one level for heating and another for cooling at five speeds; ZEPHYR publishes five values without separating the modes, under a header that names only four speeds, while its brochure advertises seven fan speeds. Neither states the measurement method. The figures give an order of magnitude, not a ranking. Diagram, not to scale.
Deep cold

Below −15 °C, the ZU1 and the ZEPHYR, source by source

Below −15 °C, each certificate publishes just one more value: at −27.2 °C for the ZU1 and at −25 °C for the ZEPHYR Series 25. The SHARP brochure also publishes maximum capacities at −20 and −25 °C. For ZEPHYR, the page shows the range between its two certified points, then its last published value.

At −25 °C, two sources. SHARP's 12,500 BTU/h comes from the brochure, outside the certificate; ZEPHYR's 11,500 BTU/h comes from AHRI certificate 215414831. At −15 °C, measured the same way by the certificate, maximum capacities are 18,000 BTU/h for both. The ZEPHYR series brochure advertises heating down to −30 °C, without giving a capacity there.
Features

Features: what each document says

Only the features named in the SHARP ZU/ZHU brochure, its installation manual and the ZEPHYR 25 R-454B series brochure are listed. A silent document is flagged as such; that does not prove the unit lacks the feature.

Presence sensor

SHARP ZU1 Not offered on the ZU1: according to the brochure, SHARP keeps the motion-sensor options for the ZHU series.

ZEPHYR Series 25 Not stated in the documents consulted.

Airflow direction (louvers)

SHARP ZU1 Coanda airflow with a long vane, and the Multi Space function, per SHARP. Four-way swing is not mentioned in the SHARP documents consulted.

ZEPHYR Series 25 Horizontal and vertical auto swing (“4D airflow”) and louver position memory.

Night modes

SHARP ZU1 Not stated in the documents consulted.

ZEPHYR Series 25 Quiet and sleep modes, 24-hour timer.

Wi-Fi and app

SHARP ZU1 Built-in Wi-Fi on every unit in the series, per the brochure.

ZEPHYR Series 25 Wi-Fi is not mentioned in the brochure; wireless remote with backlit screen.

Cleaning and filters

SHARP ZU1 Plasmacluster cleaning function: the page gives the function's name, not the claimed effects.

ZEPHYR Series 25 Auto cleaning; the filters are not described in the brochure.

Frost protection

SHARP ZU1 Not stated in the documents consulted.

ZEPHYR Series 25 Automatic 8 °C (46 °F) heating.

Defrost and outdoor base

SHARP ZU1 RAPID DEFROST and DEFROST modes; HOT GAS PIPE system with multiple drain holes and PRE-WARM.

ZEPHYR Series 25 Auto defrost; electric heater in the outdoor chassis, 200 W per the NEEP record.

Auto restart

SHARP ZU1 Automatic restart after a power outage.

ZEPHYR Series 25 Auto restart, per the brochure.

Sound

Sound, inside and outside

The published levels for each indoor-unit speed, then the outdoor unit's level.

Indoor unit, heating

SHARP: five speeds (Sh, H, M, B, Sb), heating, measurement method not stated in the brochure. ZEPHYR: five values, from highest to lowest, mode and method not stated.

Outdoor unit

SHARP: 52 dB(A) in heating, method not stated. ZEPHYR: 58 dB, method not stated.

dB

How to read these figures. A dot is a fan speed, with the level the manufacturer publishes. dB(A) reads on a logarithmic scale: 3 dB more is about twice the sound energy. In a living area, it is mostly the low speeds, the evening and night ones, that you hear for hours.

Why this is not a ranking. Neither SHARP nor ZEPHYR states how its levels are measured. Without a known method, the values cannot be compared decibel for decibel: method not stated — not comparable.

Each manufacturer measures with its own method; the figures give an order of magnitude, not a ranking.

Installation

From the living area to the outside

Dimensions, weights, piping and electrical protection, as published by each manufacturer. The indoor units are shown to the scale of their width.

SHARP ZU141 27/64 in wide
SHARP ZU1 18,000 BTU indoor unit
41 27/64 in
ZEPHYR Series 2543 5/16 in wide
ZEPHYR Series 25 18,000 BTU indoor unit
43 5/16 in

Is your wall wide enough?

48 in

Cabinet width only. The clearances needed on each side are in each model's installation manual.

Published dataSHARP ZU1ZEPHYR Series 25
Maximum piping length65.6 ft (20 m)ZU/ZHU/BU installation manual, EN-2Length not stated in the series brochure
Pre-charged length25 ft (7.6 m)Beyond that: 0.16 oz/ftLength not stated in the series brochure
Liquid – gas diameters1/4 – 3/8 in1/4 – 1/2 in
Indoor unit W × H × D, weight41 27/64 × 12 7/16 × 9 51/64 in, 31 lb43 5/16 × 12 13/16 × 9 5/8 in, 14.5 kg (32 lb)
Outdoor unit W × H × D, weight33 15/32 × 27 15/16 × 13 in, 95 lb33 7/8 × 25 9/16 × 12 3/16 in, 44 kg (97 lb)
Power supply208-230 V, single phase, 60 Hz208/230 V, single phase, 60 Hz
Electrical protection20 A circuit breakerInstallation manual, EN-6; the brochure prints a 25 A max. fuseMCA 11.5 A, MOP 15 AZEPHYR 25 R-454B series brochure
Airflow752 cfm at the highest speed, heating1,100 m³/h (about 647 cfm), speed not stated
Advertised heating / cooling range−27 to 24 °C / −10 to 46 °CDown to −30 °C / down to −15 °CSeries brochure statements
Fan speeds5 speeds (Sh, H, M, B, Sb)7 speeds advertised; sound published for 5

Values from the manufacturers' documents. The piping lengths of the 18,000 BTU ZEPHYR are not in the series brochure; they are confirmed in the exact model's installation manual.

FAQ

Frequently asked questions

Why compare this project’s ZU1 with the ZEPHYR Series 25?

Because a family equipping its living area looks at units of the same type and size, and the ZEPHYR brochure publishes the sound of five speeds, like SHARP. The 18,000 BTU ZEPHYR Series 25 is sold by AirGreen. This choice is not a ranking.

Is there a ranking on this page?

No. The ZU1 and ZEPHYR Series 25 values are shown next to each other, each with its document and test conditions. The “higher” marker only appears for the same measure taken under the same conditions.

Does the SHARP ZU1 have a motion sensor?

No, according to the SHARP ZU/ZHU brochure: the motion-sensor options are only available on the ZHU series. The ZU1 installed in Kirkland belongs to the ZU series. The ZEPHYR brochure consulted does not mention one either.

Does the ZU1 swing air in four directions?

The SHARP documents consulted describe Coanda airflow with a long vane and a Multi Space function; they do not mention four-way swing. The ZEPHYR brochure, for its part, advertises horizontal and vertical auto swing.

Which one is quieter?

The brochures publish 25 dB(A) for the ZU1's lowest speed in heating and 36 dB for the ZEPHYR's lowest value. Neither states its measurement method: these figures give an order of magnitude, they do not let us name the quieter one.

Do both use the same refrigerant?

No. The SHARP ZU1 uses R-32 (GWP 675) and the ZEPHYR Series 25 uses R-454B (GWP 466), per the IPCC's 4th report. Both are class A2L per ASHRAE 34.

Does LogisVert apply to these two models?

To find out, check Hydro-Québec's list of eligible units in force on the date of purchase, with the exact model number; the list changes. This page gives no amount.

Certified data sheet

What the two certificates say

ValueSHARP ZU1ZEPHYR Series 25
Certificate
AHRI certificate · NEEP record213246053 · NEEP 507396215414831 · NEEP 418301
RefrigerantR-32 · GWP 675 (IPCC AR4) · class A2LR-454B · GWP 466 (IPCC AR4) · class A2L
ENERGY STARYes, cold climate included (NEEP)Yes, cold climate included (NEEP)
Seasonal efficiency
SEER22421
EER21312.95
HSPF2 region IV1110
HSPF2 region V98.5
Heating at 8.3 °C (47 °F)
Capacity min. / rated / max.5,500 / 21,600 / 25,600 BTU/h5,500 / 18,000 / 19,000 BTU/h
COP min. / rated / max.5.76 / 4.22 / 3.683.66 / 3.69 / 3.24
Heating at −8.3 °C (17 °F)
Capacity min. / rated / max.7,500 / 22,000 / 22,000 BTU/h4,675 / 18,000 / 18,500 BTU/h
COP min. / rated / max.3.38 / 2.38 / 2.383.43 / 1.95 / 1.95
Heating at −15 °C (5 °F)
Capacity min. / rated / max.5,800 / 18,000 / 18,000 BTU/h4,000 / 18,000 / 18,000 BTU/h
COP min. / rated / max.2.93 / 2.20 / 2.201.38 / 1.90 / 1.90
Coldest certified point
Test temperature−27.2 °C (−17 °F)−25 °C (−13 °F)
Capacity min. / max.3,200 / 11,500 BTU/h2,000 / 11,500 BTU/h
COP min. / max.2.04 / 1.880.76 / 1.43
Cooling at 35 °C (95 °F)
Rated capacity at 35 °C: min. / rated / max.6,000 / 18,000 / 21,600 BTU/h4,500 / 18,000 / 19,000 BTU/h
COP min. / rated / max.5.67 / 3.82 / 2.933.30 / 3.80 / 2.95

“higher” marks the higher value of the same measure under the same conditions. It is not a recommendation.

Both are on the AirGreen website.

Each unit, the 18,000 BTU SHARP ZU1 and ZEPHYR Series 25, has its product page on airgreen.ca with its documents. A living area to heat and cool, as in Kirkland? Call us or request an estimate.

Sources

Documents consulted

NEEP — record 507396SHARP AY-XP18ZU1 / AE-X18ZU1, AHRI certificate 213246053; ashp.neep.org, modified Nov. 6, 2026, consulted Nov. 17, 2026
NEEP — record 418301ZEPHYR ZE-18CB25I / ZE-18CB25O, HiULTRA series, AHRI certificate 215414831; modified Nov. 6, 2026, consulted Nov. 17, 2026
SHARP — “ZU/ZHU” brochureFrench, distributor RBL A/C, undated; columns AY-XPC18ZU / AE-X18ZU; consulted Nov. 17, 2026
SHARP — ZU/ZHU/BU installation manualglobal.sharp, IM_ZU_ZHU_BU.pdf, pages EN-2 and EN-6; consulted Nov. 17, 2026
ZEPHYR — “25 SEER Series R-454B” brochureOne page, undated, no number; ZE-18CB25 column; file BROCHURE_-_ZEPHYR_25_SEER_-_R454B.pdf; consulted Nov. 17, 2026
Hydro-Québec — Electricity ratesApril 1, 2026, Rate D, sec. 2.5
NRCan — HOT2000 climate mapMontréal Intl station: 4,167 degree-days (base 18 °C), −23.1 °C
IPCC — Fourth Assessment Report (AR4); ASHRAE 34100-year GWP: R-32 675, R-454B 466; safety class A2L

Going further

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).