Project

SHARP ZU1 wall heat pump installation in Saint-Constant: the job and the electrical panel next to the FUJITSU AIRSTAGE ORION XLTH

An 18,000 BTU SHARP ZU1 installed in a Saint-Constant family house, for heat waves and for winter, compared with the FUJITSU AIRSTAGE ORION XLTH: what each unit draws from the electrical panel depending on the temperature, plus cost per season and extreme cold.

By AirGreen Climatisation & Chauffage Admin15 min read
SHARP ZU1 wall heat pump installation in Saint-Constant: the job and the electrical panel next to the FUJITSU AIRSTAGE ORION XLTH
SHARP ZU1 wall heat pump installation in Saint-Constant: the job and the electrical panel next to the FUJITSU AIRSTAGE ORION XLTH
Generic diagram: wall-mounted heat pump, indoor and outdoor units

In summer, the outdoor unit rejects the house's heat outside.

Generic illustration of this type of installation, not a survey of this job site. Tap a number.

  1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

  2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

  3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

  4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

  5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

  6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

  7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

Comparison · Wall heat pump · 18,000 BTU

SHARP ZU1 and FUJITSU AIRSTAGE ORION XLTH: what the electrical panel sees

AirGreen installed an 18,000 BTU SHARP ZU1 in a family house in Saint-Constant, to cool during heat waves and heat all winter. This page compares it with the same-size FUJITSU AIRSTAGE ORION XLTH, also offered by AirGreen, from an often-overlooked angle: the electricity each unit draws, condition by condition, and the protection each manufacturer requires. No ranking.

Published protection 25 A fuse · ZU120 A breaker · ORION XLTHHSPF2 Region V 9.0 · 10.1R-32 · both
AirGreen product card SHARP ZU1 18,000
SHARP

SHARP ZU1 18,000

AY-XP18ZU1 / AE-X18ZU1 · AHRI 213246053Installed in Saint-ConstantSee the product page
AirGreen product card FUJITSU AIRSTAGE ORION XLTH 18,000
FUJITSU AIRSTAGE

FUJITSU AIRSTAGE ORION XLTH 18,000

ASUH18KZAS / AOUH18KZAH1 · AHRI 215647921See the product page
Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards, which heated this Saint-Constant house, serve as the reference.

How this amount is calculated
  1. Heat to deliver over the winter. A zone whose heat loss reaches 18,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 18,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The project

Saint-Constant: one system for heat waves and for winter

The owner of this Saint-Constant family house wanted one system for two seasons: cool the house during heat waves, then heat it all winter long. After assessing the house’s needs, AirGreen installed an 18,000 BTU SHARP ZU1 wall heat pump.

In the photo, the outdoor unit is fixed to the brick wall on a bracket, above the gravel: mounted high, it stays clear of snow and debris. Inside, the wall head was placed to spread the air through the room.

A unit that heats in January and cools in July also adds a dedicated circuit to the house’s electrical panel. That is this page’s angle: what each unit draws depending on the temperature, and the protection each manufacturer requires.

SHARP ZU1 outdoor unit on a wall bracket above the gravel, Saint-Constant
The outdoor unit on its wall bracket, above the gravel. Photo: AirGreen, Saint-Constant.
The electrical panel

How many amps, depending on the temperature

At each certified test, NEEP publishes the electrical power drawn by the heat pump. Divided by the voltage, it gives an average current. Pick a temperature and an operating level: each gauge shows that current next to the maximum protection published by the manufacturer, and the third shows what baseboards would draw to make the same heat as the ZU1.

Outdoor temperature
Operating level
Voltage

Average current = certified power ÷ voltage, power factor assumed to be 1: an order of magnitude, not a measurement. Starting current, the panel load calculation and the circuit size fall under the Québec Construction Code, Chapter V – Electricity, and a master electrician. For the ZU1, SHARP only publishes the maximum fuse in the brochure consulted; for the ORION XLTH, FUJITSU AIRSTAGE also publishes a heating running current of 6.5 A (rated) to 15.9 A (maximum).

Extreme cold

Below −15 °C, every published value and its source

NEEP certifies the ZU1 down to −27.2 °C and the ORION XLTH down to −26.1 °C. SHARP adds capacities at −20 and −25 °C in the ZU brochure; for the ORION XLTH 18,000, the values between −15 and −26.1 °C are the two certified points that frame each temperature.

FUJITSU AIRSTAGE also prints percentages of rated capacity at −15, −21 and −26 °C (141, 127 and 106%), without stating the base: they are not converted to BTU/h here. The ZU brochure prints model AY-XPC18ZU / AE-X18ZU; its values are identical to the ZU1 certificate at the common points.

Features

What each document names

This grid keeps only what each brochure names. A feature that is not listed may exist; the document simply does not mention it.

Wi-Fi and app
ZU1 · built-in Wi-Fi; app not namedORION XLTH · built-in Wi-Fi; AIRSTAGE Mobile app

Remote setting and monitoring by phone.

Defrost
ZU1 · Hot Gas Pipe, named in the ZU brochureORION XLTH · automatic defrost; 150 W base pan heater declared to NEEP

Two ways to keep the bottom of the outdoor unit clear of ice.

Occupancy and minimum heat modes
ZU1 · not named in the ZU brochure (sensor: ZHU series)ORION XLTH · occupancy mode and minimum heat named

Useful in a room that is occupied part of the time.

Airflow direction: Coanda and Multi Space
ZU1 · named in the ZU brochureORION XLTH · six speeds plus Auto; louvers not detailed

Air is guided along the ceiling rather than onto the occupants.

Auto restart
ZU1 · named in the ZU brochureORION XLTH · named in brochure FG8153C

After a power outage, the unit resumes its settings.

Plasmacluster filter and cleaning
ZU1 · named in the ZU brochureORION XLTH · no equivalent named

SHARP technology name only; this page attributes no effect to it.

Sound

Indoor unit sound in heating

Five published speeds for the ZU1, six for the ORION XLTH. Outdoors, SHARP publishes 52 dB(A) and FUJITSU AIRSTAGE 50 dB(A) in heating.

dB

How to read these figures · dB(A) of sound pressure: the lower the number, the quieter. Each dot is a published fan speed.

Why this is not a ranking · Speeds do not match from one brand to the other, and the documents state neither the distance nor the measuring room.

Measurements taken by each manufacturer with its own method.

Installation

The published limits for installing either one

ItemSHARP ZU1 18,000FUJITSU AIRSTAGE ORION XLTH 18,000
Maximum piping length66 ft (20 m)ZU/ZHU brochure (RBL), AY-XPC18ZU column164 ft (50 m); minimum 16 ftFUJITSU AIRSTAGE brochure FG8153C, rev. 4/2025
Pre-charged lengthNot published by the manufacturer in the ZU brochure consulted66 ft (20 m)FUJITSU AIRSTAGE brochure FG8153C, rev. 4/2025
Maximum height difference33 ft (10 m)ZU/ZHU brochure (RBL), AY-XPC18ZU column98 ft (30 m)FUJITSU AIRSTAGE brochure FG8153C, rev. 4/2025
Liquid – gas diameters1/4 – 3/8 inZU/ZHU brochure (RBL), AY-XPC18ZU column3/8 – 5/8 inFUJITSU AIRSTAGE brochure FG8153C, rev. 4/2025
Outdoor unit W × H × D, weight33.5 × 27.9 × 13 in, 95 lbZU/ZHU brochure (RBL), AY-XPC18ZU column37 × 31 × 12.6 in, 117 lbFUJITSU AIRSTAGE brochure FG8153C, rev. 4/2025
Indoor unit W × H × D, weight41.4 × 12.4 × 9.8 in, 31 lbZU/ZHU brochure (RBL), AY-XPC18ZU column45.3 × 13.4 × 11 in, 36 lbFUJITSU AIRSTAGE brochure FG8153C, rev. 4/2025
Electrical protection208-230 V; max. fuse 25 AZU/ZHU brochure (RBL), AY-XPC18ZU column208-230 V; max. breaker 20 AFUJITSU AIRSTAGE brochure FG8153C, rev. 4/2025
Electrical supply: heating current (rated / max.)Not published by the manufacturer in the ZU brochure consulted6.5 / 15.9 AFUJITSU AIRSTAGE brochure FG8153C, rev. 4/2025
Dehumidification2.4 L/h (5.1 pt/h, label not defined in the brochure)ZU/ZHU brochure (RBL), AY-XPC18ZU column3.6 L/h (7.6 pints/h)FUJITSU AIRSTAGE brochure FG8153C, rev. 4/2025
Stated heating range−27 to 24 °CZU/ZHU brochure (RBL), AY-XPC18ZU column−26 to 24 °CFUJITSU AIRSTAGE brochure FG8153C, rev. 4/2025
Stated cooling range−10 to 46 °CZU/ZHU brochure (RBL), AY-XPC18ZU column−10 to 50 °CFUJITSU AIRSTAGE brochure FG8153C, rev. 4/2025

Values declared by each manufacturer, not certified. The ORION XLTH is larger and heavier, indoors and out: 117 lb against 95 lb for the outdoor unit, a figure to check for a wall-bracket mounting like the one in the photo.

FAQ

Questions about this job and these two units

Why talk about the electrical panel in a heat pump comparison?

Because a heat pump adds a dedicated circuit to the house panel, and what it draws changes with the temperature. The Saint-Constant owner wanted one system for heat waves and for winter: the manufacturers’ documents say which protection each unit requires, and NEEP publishes the power drawn at each test.

Are the amps shown those of my bill or my panel?

Neither exactly: they come from the electrical power certified by NEEP at each test, divided by the voltage (power factor assumed to be 1). It is an order of magnitude to understand the load. The panel load calculation is done under the Québec Construction Code, Chapter V – Electricity, by a master electrician.

Why does the ORION XLTH draw more amps at maximum?

Because it delivers more heat at maximum: 25,400 BTU/h certified at −15 °C against 18,000 for the ZU1. More heat takes more electricity, even with a comparable COP. For the same heating output, the gap shows in the COP, not in the amps.

What happens below −26 °C?

The ZU1 has a certified point at −27.2 °C (11,500 BTU/h) and a heating range stated down to −27 °C. The ORION XLTH has a certified point at −26.1 °C (19,110 BTU/h); FUJITSU AIRSTAGE states heating down to −26 °C and no automatic shut-off, with no capacity published below. Neither has a published value at −30 °C.

Why is the outdoor unit on a wall bracket?

On this job, the outdoor unit was fixed to the wall, above the gravel, to stay clear of snow and debris. The published weight matters for this kind of mounting: 95 lb for the ZU1 outdoor unit, 117 lb for the ORION XLTH’s. The clearances to respect are those of each manufacturer’s installation manual.

Is there financial assistance?

Hydro-Québec keeps its own list of LogisVert-eligible equipment, with conditions that change. The amount is checked on that list when you apply; this page deliberately shows none.

Why is this not a ranking?

A heat pump that draws more amps is not worse: it may be delivering more heat. The page puts each figure next to its source and test condition; the choice depends on your house, your panel and your use.

Certified data

The values of both AHRI certificates, published by NEEP

ItemSHARP ZU1 18,000FUJITSU AIRSTAGE ORION XLTH 18,000
Certificate
AHRI certificate · NEEP record213246053 · 507396215647921 · 385842
RefrigerantR-32 (GWP 675, IPCC AR4; class A2L)R-32 (GWP 675, IPCC AR4; class A2L)
ENERGY STARYes; cold climate: yesYes; cold climate: yes
Seasonal efficiency
SEER224.025.5
EER213.014.0
HSPF2 Region IV11.012.5
HSPF2 Region V9.010.1
Cooling at 35 °C
Capacity min. / rated / max.6,000 / 18,000 / 21,600 BTU/h7,000 / 18,000 / 26,200 BTU/h
Heating at 8.3 °C
Capacity min. / rated / max.5,500 / 21,600 / 25,600 BTU/h8,000 / 21,600 / 31,800 BTU/h
COP min. / rated / max.5.76 / 4.22 / 3.685.45 / 4.37 / 3.21
Heating at −8.3 °C
Capacity min. / rated / max.7,500 / 22,000 / 22,000 BTU/h5,200 / 13,600 / 27,200 BTU/h
COP min. / rated / max.3.38 / 2.38 / 2.383.72 / 3.32 / 2.30
Heating at −15 °C
Capacity min. / rated / max.5,800 / 18,000 / 18,000 BTU/h5,000 / 24,800 / 25,400 BTU/h
COP min. / rated / max.2.93 / 2.20 / 2.203.57 / 2.08 / 2.02
Max. capacity at −15 °C18,000 BTU/h25,400 BTU/h
Coldest point of each certificate
Test temperature−27.2 °C (−17 °F)−26.1 °C (−15 °F)
Capacity min. / max.3,200 / 11,500 BTU/h3,700 / 19,110 BTU/h
COP min. / max.2.04 / 1.883.10 / 1.65

A cell marked “higher” flags the higher value of the same measure, under equal test conditions; it is not buying advice.

A heat pump and a panel to check?

In-home estimate and written quote: we start from your house, your electrical panel and the room to heat and cool.

(514) 316-2973Request a quote
Sources

Documents consulted

NEEP · SHARP ZU1 18,000Record 507396, AHRI certificate 213246053 (AY-XP18ZU1 / AE-X18ZU1), accessed November 17, 2026
NEEP · FUJITSU AIRSTAGE ORION XLTH 18,000Record 385842, AHRI certificate 215647921 (ASUH18KZAS / AOUH18KZAH1), accessed November 17, 2026
FUJITSU AIRSTAGE · ORION XLTH brochureFG8153C, rev. 4/2025, 18KZAH1 column; accessed November 17, 2026
SHARP · ZU / ZHU brochure (French)Distributor RBL A/C, undated; AY-XPC18ZU / AE-X18ZU column; accessed November 17, 2026
Hydro-QuébecElectricity rates (April 1, 2026, Rate D, sec. 2.5)
NRCanHOT2000 climate map, Montréal Intl
In figures
The steps

How it goes, from the first call to the end

The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

Step 1 of 9The on-site estimate

We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

  1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
  2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
  3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
  4. The wall openingA single opening, with the slope the drain needs to flow outside.
  5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
  6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
  7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
  8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
  9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
The unit

What the unit delivers when it is cold

The range as published on airgreen.ca: pick a size to see its capacity in deep cold.

The range, size by size
SizeHeating at −8 °CHeating at −15 °CColdest certified pointCOP at −15 °CSEERHSPFIndicative LogisVert aid
Sharp ZU1 12 00014,50012,000−27 °C: 7,2002.1122.011.0$1,740
Sharp ZU1 15 00018,10015,300−27 °C: 10,1002.124.011.0$2,172
Sharp ZU1 18 00022,00018,000−27 °C: 11,5002.224.011.0$2,640
Sharp ZU1 24 00022,40019,000−27 °C: 12,3002.222.011.0$2,688
14,500Its full nominal heating at −8 °C

According to NEEP, it delivers 14,500 BTU/h at −8 °C (17 °F), more than at 8 °C (14,000 BTU/h). It heats as hard in moderate cold as in mild weather.

7,200Still 7,200 BTU/h at −27 °C

According to NEEP, its certified maximum capacity at −27 °C (−17 °F) is 7,200 BTU/h, 60% of its nominal 12,000 BTU size.

17,100A 17,100 BTU/h reserve in mild weather

At 8 °C, its certified maximum capacity reaches 17,100 BTU/h, 42% more than its nominal 12,000 BTU size.

Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.

Your numbers

And at your place?

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Before / afterThe cost of the same heat

Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):

Before · baseboards11.142¢/kWh
After · heat pump–

Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.

Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    And at your place?

    Which type of equipment for your project?

    Pick what looks like your need.

    Mistakes avoided

    Four mistakes we do not make

    Flip each card to see what we do instead.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.
    Going further

    Useful pages for what comes next

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    Tell us about your house. We come and see it for free.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment