BU dual zone, 24,000 Btu/h
Outdoor AE-X3M24BU · heads AY-XPC9BU / AY-XPC12BU / AY-XPC18BU
AHRI 213927543 · NEEP 507394
A 24,000 Btu/h SHARP BU dual-zone system heats and cools the living room and main bedroom of a Plateau-Mont-Royal house. Its certified values, next to those of an LG Multi F R32 of the same capacity.

Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
This job connects the living room and the main bedroom to a single 24,000 Btu/h SHARP BU outdoor unit. The 24,000 Btu/h LG Multi F R32 answers the same need, two wall heads on one compressor, under its own certificate. Here is what the AHRI certificates published by NEEP and both manufacturers' documents say about each, with no ranking.

Outdoor AE-X3M24BU · heads AY-XPC9BU / AY-XPC12BU / AY-XPC18BU
AHRI 213927543 · NEEP 507394

Outdoor KUMXB241A · Multi F R32 heads, e.g. KNUAB121A
AHRI 214848483 · NEEP 392649
Both certificates cover a “multi-zone, all non-ducted indoor units” combination. Images: AirGreen product cards, for identification. The LG card shows a standard head and an ARTCOOL head; both connect to this outdoor unit.
AirGreen estimate for the same home whose two rooms together need 24,000 Btu/h, in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards are the reference.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The real bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
Here the gap comes mostly from winter: HSPF2 region V of 9.0 for the SHARP BU and 7.69 for the LG, on the same heat to supply. The 12,000 Btu/h heads in each room do not change the calculation: it is the complete system, outdoor unit and heads together, that is certified.
The original article, published in December 2024, tells of a SHARP BU dual-zone installation in a Plateau-Mont-Royal house. The owners wanted to heat and cool two rooms that are not used at the same hours: the living room, where the family gathers, and the main bedroom, which matters mostly at night.
The system installed: one 24,000 Btu/h AE-X3M24BU outdoor unit and two 12,000 Btu/h wall heads, one per room, each with its own setpoint. Both heads were placed so the air moves through the room without blowing straight at the couch or the bed, and the line sets were run discreetly.
On the Plateau, the question that comes up with this kind of project is rarely the brand: it is where the outdoor unit goes (yard, back balcony, flat roof) and how the lines reach each room. The “plex, cut away” section below lets you try those choices against the limits each manufacturer publishes.
Pick the floor of the unit, where the outdoor unit goes and the length of each line. Each system is checked against the limits its manufacturer publishes. Where a document is silent, the page says so.
Drawing assumptions: 10 ft per storey, heads mounted 7 ft above the floor, roof of a 3-storey plex at 30 ft. Measure your own home: these figures are for trying, not for design.
Limits: SHARP 2025 brochure (FR) for the AE-X3M24BU; LG sheet SB_Multi_F_ODU_R32_KUMXB241A (January 2025). The SHARP brochure publishes no per-room length, no pre-charged length and no head-to-head height: those cells stay “not published” and are checked in the installation manual supplied with the unit.
Both certificates give a point at −15 °C. Colder, SHARP publishes capacities down to −27 °C and NEEP certifies a point at −27.2 °C; LG publishes and certifies a point at −20 °C, the limit of the heating range its sheet states. Nothing is made up between the points.
The −20 °C row compares a manufacturer value (SHARP, brochure) and a certified value (LG, NEEP): same temperature, different sources. ENERGY STAR “cold climate” is listed “yes” for the SHARP BU and “no” for the LG KUMXB241A in the NEEP record.
For SHARP, the source is the 2025 brochure; for LG, the KNUAB121A head sheet (May 2025). A feature missing from a document is not necessarily missing from the unit: the owner's manual may say more.
SHARP BU Not named for the BU series in the brochure consulted.
LG Built-in Wi-Fi, LG ThinQ app.
SHARP BU Not named in the brochure consulted.
LG R32 leak detection sensor named on the sheet.
SHARP BU Not detailed in the brochure consulted.
LG Washable pre-filter, 3M Micro Dust filter, self-cleaning coil.
SHARP BU Named by the brochure for the BU series. This page attributes no effect to it.
LG Not named (a SHARP technology).
SHARP BU Not detailed in the brochure consulted.
LG Automatic up-down and left-right louvers.
SHARP BU Not detailed in the brochure consulted.
LG Auto restart, sleep mode, 24-hour timer.
Each dot is a published fan speed.
Cooling and heating.
How to read these figures. The lower the number, the quieter the unit; 10 dB(A) more sounds roughly twice as loud. LG measures sound pressure in an anechoic chamber (ISO 3745); the SHARP brochure does not state its method.
Why this is not a ranking. Different method — not comparable point by point. Each manufacturer's range helps place the unit, nothing more.
Measurements taken by each manufacturer with its own method; they do not compare directly.
Widths: 34 39/64 in for the SHARP AY-XPC12BU head (SHARP 2025 brochure) and 32 15/16 in for the LG KNUAB121A head (LG sheet, May 2025). Heads drawn to scale by width; also allow the clearance the installation manual requires.
| Installation | SHARP BU | LG Multi F R32 |
|---|---|---|
| Piping | ||
| Maximum piping length (total) | 230 ft (70 m)SHARP 2025 brochure | 230 ftLG KUMXB241A sheet |
| Piping length per indoor unit | Not in the SHARP brochure consulted. | 9.8 to 82 ft |
| Pre-charged length (no added refrigerant) | Not in the SHARP brochure consulted. | 98.4 ft in total, then 0.22 oz/ft |
| Maximum height difference, outdoor to indoor | 33 ft (10 m) | 49.2 ft |
| Maximum height difference between indoor units | Not in the SHARP brochure consulted. | 24.6 ft |
| Liquid – gas diameters, per room | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Number of heads that can connect | 2 or 3 | 2 or 3 |
| Units | ||
| Outdoor unit W × H × D, weight | 33 15/32 × 27 15/16 × 13 in, 115 lb | 34 1/4 × 25 19/32 in (W × H, dimension drawing), 103.4 lb |
| 12,000 Btu/h indoor unit W × H × D, weight | 34 39/64 × 11 3/8 × 9 1/64 in; weight not given in the brochure | 32 15/16 × 12 1/8 × 7 7/16 in, 19.73 lb |
| Power supply | 208-230 V, 60 Hz, single phase | 208-230 V, 60 Hz, single phase |
| Electrical protection | Max. fuse 25 A | MOP 20 A, MCA 16.5 A |
| Stated heating range | −27 to 24 °C | −20 to 18 °C (wet bulb) |
| Stated cooling range | −10 to 46 °C | −10 to 48 °C |
| Dehumidification (12,000 Btu/h head) | Not in the SHARP brochure consulted. | 1.3 L/h (2.75 US pints/h) |
Sources: SHARP 2025 brochure (FR); LG sheet SB_Multi_F_ODU_R32_KUMXB241A_2025_01_07_193346 and head sheet SB_MultiF_HiEff_WallMounted_IDU_R32_KNUAB121A_2025_05_15_131307. These are published design limits; installation follows the manufacturer's manual and the codes in force.
Not exactly. Capacity belongs to the system. Both certificates give 24,000 Btu/h of cooling at 35 °C for the certified combination; each head's capacity is a manufacturer nominal value, and the outdoor unit shares its output according to what the rooms ask for.
It is the ENERGY STAR cold-climate designation, which NEEP repeats: “yes” for the SHARP BU (507394), “no” for the LG KUMXB241A (392649). It rests on low-temperature efficiency criteria. The capacities published at each temperature are in the Deep cold section.
Neither manufacturer publishes capacity beyond its stated range: −20 °C (wet bulb) for the LG, −27 °C for the SHARP. The page shows each one's last published value, with its temperature. For colder nights, the home's backup heat takes over.
Both outdoor units accept 2 or 3 heads according to their documents. The allowed combinations are the manufacturer's (the SHARP brochure lists them for the AE-X3M24BU); a quote checks the combination and piping before any addition.
Eligibility is checked on each program's official list (Hydro-Québec's LogisVert, for example), by AHRI certificate number, on the date of the application. Lists and amounts change; this page promises none.
Each manufacturer publishes its own terms. We do not compare them here; the warranty documents come with the quote.
| Certified value (AHRI, published by NEEP) | SHARP BU | LG Multi F R32 |
|---|---|---|
| Certificate | ||
| AHRI certificate · NEEP record | 213927543 · 507394 | 214848483 · 392649 |
| Refrigerant | R-32 (GWP 675, IPCC AR4; class A2L) | R-32 (GWP 675, IPCC AR4; class A2L) |
| ENERGY STAR · cold climate | Yes · cold climate: yes | Yes · cold climate: no |
| Cooling | ||
| SEER2 | 24.0 | 22.5 |
| EER2 | 14.0 | 12.5 |
| Rated capacity at 35 °C | 24,000 BTU/h | 24,000 BTU/h |
| Heating | ||
| HSPF2 region IV | 11.5 | 9.8 |
| HSPF2 region V | 9.0 | 7.69 |
| Min. / rated / max. capacity at 8.3 °C | 8,800 / 26,000 / 30,000 BTU/h | 10,080 / 24,600 / 29,000 BTU/h |
| Min. / rated / max. capacity at −8.3 °C | 7,600 / 25,000 / 25,000 BTU/h | 6,781 / 15,300 / 21,400 BTU/h |
| Min. / rated / max. capacity at −15 °C | 8,400 / 21,200 / 21,200 BTU/h | 5,759 / 17,300 / 18,400 BTU/h |
| COP min. / rated / max. at 8.3 °C | 4.69 / 4.35 / 4.19 | 5.01 / 4.19 / 3.02 |
| COP min. / rated / max. at −15 °C | 2.46 / 2.30 / 2.30 | 3.59 / 2.30 / 2.51 |
| Coldest point of each record (different temperatures) | ||
| Coldest point: temperature | −27.2 °C (−17 °F) | −20 °C (−4 °F) |
| Coldest point: min. – max. capacity | 5,100 – 14,600 BTU/h | 5,200 – 15,400 BTU/h |
| Coldest point: COP at maximum | 1.84 | 2.23 |
“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation. NEEP records consulted November 17, 2026 (507394 modified November 6, 2026).
Two rooms to heat and cool on the Plateau or elsewhere in Montréal? The estimate is done on site, with your measurements.
Data verified November 17, 2026. Certified values: AHRI certificates published by NEEP. Declared values: the manufacturers' documents cited. A value that changes at NEEP or at a manufacturer prevails over this page.
SHARP, Plasmacluster, LG, Multi F and ThinQ are trademarks of their respective owners. Logos and images identify the products only. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca.
The range as published on airgreen.ca: pick a size to see its capacity in deep cold.
| Size | Heating at −8 °C | Heating at −15 °C | Coldest certified point | COP at −15 °C | SEER | HSPF | Indicative LogisVert aid |
|---|---|---|---|---|---|---|---|
| Sharp BU 24 0002 Zones (Dual Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
| Sharp BU 24 0003 Zones (Triple Zone) | 25,000 | 21,200 | −27 °C: 14,600 | 2.3 | 24.0 | 11.5 | $3,000 |
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Among the year’s most efficient according to ENERGY STAR, on top of its cold-climate certification.
Minimum certified capacity (NEEP): it slows down instead of stopping when a single room calls.
NEEP still lists 14,600 BTU/h at a COP of 1.84 at −17 °F.
Global warming potential of R-32, versus 2,088 for R-410A (ENERGY STAR).
Data read live from the airgreen.ca page of each size (NEEP / AHRI certified performance). When the title names the installed size, it is highlighted; otherwise the whole range is shown. The aid shown is today’s, using Hydro-Québec’s rule ($120 per 1,000 BTU/h at −8 °C); amounts quoted in the article date from its publication. Only Hydro-Québec confirms the assistance granted.
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Baseboards and electric furnaces turn 1 kWh of electricity into 1 kWh of heat. A heat pump delivers more: that is its COP. At Hydro-Québec’s rate D (11.142¢/kWh above 40 kWh a day, since 1 April 2026):
Hydro-Québec: a heat pump can be up to three times more efficient than baseboards for heating in the colder months.
Estimate per kWh of heat, at the chosen temperature, using the certified COP from the product page. Taxes, access charge and backup heat not included.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
Flip each card to see what we do instead.
Three habits per season for this unit. They take a few minutes and prevent many calls.
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
No question matches. Write to us: we answer.
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).