Installation of a Zephyr — wall-mounted heat pump in Chomedey (Laval)
AirGreen installs a Zephyr wall-mounted heat pump above a patio door in Chomedey (Laval): short path, gravity drain, optimal diffusion. Expert HVAC service in Montreal , Laval , Longueuil , North Shore and South Shore .
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The article, chapter by chapter
A wall-mounted head perfectly integrated above a patio door for a more comfortable, quiet and eco-efficient living room
Client context and objectives
In this Chomedey (Laval) semi-detached house, the owners wanted to stabilize the temperature on the ground floor—living room, dining room, and kitchen area—without invasive work. We recommended a Zephyr wall-mounted heat pump for its compactness, discretion, and ability to efficiently heat and cool the open spaces typical of North Shore homes. The goal: to achieve consistent comfort , controlled consumption, and quiet operation, while preserving the existing openings and the aesthetics of the living room.
Location choice: above the patio door
We position the interior head above the patio door leading to the terrace. This location has several concrete advantages:
-
Optimized air diffusion in the axis of the living room, which quickly homogenizes the temperature.
-
Very short refrigeration path (direct passage through the exterior wall), limiting pressure losses and maximizing seasonal efficiency.
-
Condensate drainage by gravity , without additional pump, therefore without noise or additional maintenance.
-
Easy access for HVAC maintenance (filter cleaning, annual inspection).
We respect the clearances in the upper part to avoid recirculation of hot air against the ceiling and traces of "over-washing" air on the paint. The blower shutters are adjusted to project the flow slightly downwards and towards the center of the room.
Sizing and expected performance
Based on the volumes, insulation, and orientation of the glazing, the useful power required for the living area is within the standard range for residential wall-mounted heat pumps. A properly sized heat pump :
-
keeps heating efficient in cool weather and mid-season,
-
ensures pleasant air conditioning during heat waves,
-
offers an excellent consumption/comfort ratio compared to individual electric convectors.
When the installed Zephyr series is Energy Star certified and designed to perform around −25°C , the equipment may be eligible for certain provincial grants ; our team systematically checks these criteria when making the proposal.
Refrigeration route and exterior finishes
The choice of the patio door allows for a short and clean wall crossing (clean drilling in the top rail). Outside:
-
Waterproof capping and outlets protected against water and UV,
-
Continuous slope of the drain for gravity evacuation,
-
Refrigerant lines carefully insulated and taped to prevent surface condensation.
Depending on the deck layout, the outdoor unit is typically installed on a vibration-resistant slab or on wall brackets clear of the railing to optimize air circulation and winter snow removal. We always adjust the height to prevent ice buildup near the drainage outlets.
Aesthetic and acoustic integration
The Zephyr head unit visually blends into the light-colored living room wall. Its smooth front, discreet display, and low noise contribute to quality of life in everyday life: talk, watch TV, receive—the device remains in the background. Vibrations are neutralized by shock-absorbing pads and careful leveling during installation.
Air quality and maintenance
To maintain original performance:
-
Vacuum or rinse the filters every 4 to 6 weeks during periods of heavy use.
-
Schedule an annual HVAC maintenance with AirGreen: deep cleaning of the evaporator, verification of refrigeration parameters, electrical and condensate inspection.
-
Keep the outdoor unit free of leaves and frost to maintain good heat exchange.
These simple actions preserve seasonal efficiency, reduce consumption and extend the life of the equipment.
Daily driving and comfort
The wall control and remote control allow:
-
precise temperature ranges ,
-
a dehumidification mode useful during humid episodes,
-
modulated fan speeds to balance quietness and airflow,
-
programs adapted to family schedules.
By default, we set an airflow directed towards the living area and an air intake free from any obstruction (curtains, rods, high furniture), in order to avoid “dead zones”.
Construction site challenges and solutions
Limited height at the head of the bay : above a patio door, space is limited. We have:
-
checked the flatness of the lintel for perfect support,
-
chose fixings suitable for the wall material,
-
adjusted the shutter to prevent any air backflow against the ceiling (source of dark streaks).
Drilling management : the wall penetration is carried out with a slight outward slope to secure drainage. A sleeve protects the connections and prevents long-term friction.
Measurable result
After commissioning and functional tests, we observe:
-
a rapid drop in indoor temperature in air conditioning mode,
-
even distribution of air into the dining area,
-
a reduction in electricity consumption compared to resistive heating solutions used previously.
Customers appreciate the ease of use and the silence in the evening, even in the immediate vicinity of the head.
Best practices for open rooms
To ensure your HVAC system performs at its best:
-
Leave interior doors open to allow circulation.
-
Avoid blocking the air intake with long curtains.
-
In summer, choose a moderate setting (e.g. 23–24°C) to limit short cycles.
-
In winter, use the hold function and let the device work continuously at low speed for greater efficiency.
Why AirGreen for your project in Montreal, Laval, Longueuil, South Shore & North Shore?
Our team understands the real constraints of Greater Montreal housing: urban plexes in Montreal , semi-detached houses in Laval , houses on the South Shore and the North Shore . We work with an engineering + finishing approach:
-
neutral advice on the brand and range suited to your volume and insulation,
-
verification of eligibility for aid programs where relevant,
-
careful execution, deadlines met, responsive after-sales service.
Whether it's for a wall-mounted heat pump , a wall-mounted air conditioner , a MultiZone heat pump or a central system, we deliver a clean, documented site ready for many years of comfort.
What's next?
We offer an annual maintenance package and performance inspections as needed (shutter optimization, seasonal settings, filter reminders). This preventative approach maintains performance and guarantees a stable user experience, summer and winter.
Result: stable comfort and controlled consumption
This Zephyr wall-mounted heat pump installed in Chomedey (Laval) transforms the daily lives of occupants: better distributed air, controlled humidity, contained energy bills. A compact, elegant and scalable solution — perfectly aligned with the climatic and architectural realities of Greater Montreal .
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).
