Installation of a GREE FreeMatch R32 2-head heat pump in Saint-Bernard-de-Lacolle
Installation of a 2-head GREE FreeMatch R32 heat pump in Saint-Bernard-de-Lacolle: one head on the landing to condition the entire floor, the real limitations of closed doors, the use of the ceiling fan, and condensate drainage on the upper floor. The AirGreen method, Montérégie.
- City
- Region
- Equipment
- Brand
- Challenges
- Published
The job on one screen

The article, chapter by chapter
Cooling an entire floor from the corridor: what works and what you need to know before accepting it
In a two-story house, the problem is always the same: the ground floor is comfortable and the upper floor is unbearable from June to September. Warm air rises through the stairwell, accumulates beneath the roof, and the bedrooms become places where it is difficult to sleep.
At Saint-Bernard-de-Lacolle, we installed a GREE FreeMatch R32 2-head wall-mounted heat pump in this type of family residence. The head shown in the photo is mounted on the landing wall, between two bedrooms, above the open stairwell. This is a location we often recommend—but only after frankly explaining to the client what it does and does not provide.
Why the landing rather than a bedroom
The stairwell is a thermal chimney
Warm air from the ground floor rises through the staircase and spills onto the landing. By treating the air directly there, the head intercepts this mass of warm air at its point of arrival, before it spreads into the bedrooms. A head placed at the back of a single bedroom does nothing of the sort: it cools that room and leaves the rest of the floor to fend for itself.
One unit serves several rooms
A landing open to two or three bedrooms allows a single head to condition the entire floor, provided the air circulates. This is what makes a bi-zone configuration relevant for an entire house: one head for the upper floor and one head for the open area on the ground floor.
No noise in the bedrooms
Even when quiet, a head produces noticeable air movement. Installed in a corridor rather than above a bed, it disappears from the field of perception at night. This is an argument clients appreciate once summer arrives.
The limitation that must be stated: the doors being closed
Here is what an honest contractor should say before signing. A head mounted on the landing cools the floor as long as the air circulates. With the doors closed, it cools the corridor.
Many families close bedroom doors at night — for noise, privacy, or because a young child is sleeping. In that case, the bedroom becomes isolated from the only source of conditioned air, and its temperature gradually rises.
The solutions, in order of effectiveness:
- Leave the doors ajar at night. Free, and sufficient in many cases.
- Clear the bottoms of the doors. A gap of a few centimeters beneath the door allows minimal air transfer.
- Install transfer grilles above doors or in partition walls. An effective, discreet solution, but one that also transmits noise.
- Plan for a dedicated head in the primary bedroom when nighttime comfort is a priority. This is a design choice to make when calculating the load, not afterward.
We prefer to explain this before the work begins rather than receive a call in July. An informed client is a satisfied client; a surprised client never is.
The ceiling fan: an ally when it rotates in the right direction
The photo shows a ceiling fan above the landing. When used correctly, it doubles the perceived effectiveness of the heat pump.
- In summer, the fan blows downward. The air movement increases skin evaporation and makes it feel several degrees cooler, allowing you to raise the system's setpoint without sacrificing comfort.
- In winter, it should rotate in reverse at low speed. It then brings the warm air accumulated at the ceiling back down without creating a draft. In an open stairwell, this destratification is particularly useful — that is exactly where heat gets trapped.
Nearly all fans have a reversing switch on the housing. Almost no one uses it.
Airflow direction in a space open on three sides
A landing with an open stairwell presents a particular problem: some of the blown air may fall directly into the stairwell and descend to the ground floor, where it was not intended to go.
We therefore direct the airflow along the corridor, toward the bedroom doors, rather than into the open stairwell. The louvers are also adjusted differently depending on the season: horizontal airflow in cooling mode, so that the cold air naturally descends while circulating throughout the entire volume; downward airflow in heating mode, to push the heat toward the floor instead of letting it stagnate at the ceiling.
A system that “doesn’t heat” is very often one whose louvers were never redirected in the fall.
The maintenance detail we check before choosing the height
An indoor unit requires filter cleaning every four to six weeks. This is the most common reason for service calls we receive: a dirty filter reduces airflow, which reduces capacity and efficiency.
But an indoor unit mounted high above a stairwell cannot be accessed with a kitchen chair. We take this into account when determining the height and lateral position: the homeowner must be able to open the front panel and remove the filters from a stable footing, without placing a stepladder on a stair tread. When access is necessarily difficult, we say so and include cleaning in the annual HVAC maintenance contract rather than leaving it to the customer.
The upstairs condensate drain
An indoor unit produces condensate in cooling mode, and drainage relies on gravity. Upstairs, there are two possible situations:
- The unit is mounted on an exterior wall: the drain exits directly, with a clear slope. This is the ideal situation.
- The unit is mounted on an interior wall, such as a hallway wall: the drain must run through the structure for some distance before reaching the exterior. This requires a continuous slope along the entire route, without a single flat spot.
A drain that rises two centimetres somewhere inside an upper-floor wall is a leak waiting to happen — the water will eventually come back out through the indoor unit’s pan and run down the wall, one floor above the living room. When a slope cannot be guaranteed, we install a condensate pump with a safety switch that shuts the unit off if the pan fills. It is a cost we accept, not a compromise.
We test every drain by pouring water into the pan and confirming that it drains completely outside.
The installed system
The GREE FreeMatch R32 in a dual-zone configuration powers two indoor units from a single outdoor unit, a single 208/230 V circuit, and a single wall penetration.
What matters for a family in Quebec:
- SEER2 21 / HSPF2 10 / EER2 12, certified AHRI and ENERGY STAR Cold Climate;
- Heating maintained down to -30 °C, with intelligent defrost and self-diagnostics;
- R32 refrigerant, A2L safety classification, with low global warming potential;
- G10 inverter, which allows operation at partial load for most of the season instead of a succession of starts;
- Automatic voltage adaptation, useful in rural areas where the power supply fluctuates more;
- 10-year warranty on parts and the compressor, with 2 additional years upon registration.
Because R32 is classified as A2L, a minimum room area applies to each head based on the served load and mounting height. For a head installed in an open hallway overlooking a staircase, the available volume is generous; for a head being considered for a small enclosed bedroom, the verification may change the permitted capacity. This calculation is performed during the design stage.
Rebates
The FreeMatch R32 is certified ENERGY STAR, Cold Climate, and AHRI, making it eligible for the categories covered by Quebec assistance programs for efficient heating systems. The AHRI number applies to the combination of the outdoor unit and indoor heads, never to the outdoor unit alone. We validate the combination and eligibility before signing.
Our service area
At AirGreen, we provide complete HVAC installation: load calculation, selection of the certified combination, indoor and outdoor installation, documented commissioning, and annual HVAC maintenance. We serve Montreal, Laval, Longueuil, the North Shore, the South Shore, and Montérégie, as far as Saint-Bernard-de-Lacolle and the border. On a floor of a family home, the right location is not chosen at random—it is chosen based on how the family actually lives in the house.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
Model, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
Floors and furniture protected, wall plate position marked level, wall opening located.
A single opening, with the slope the drain needs to flow outside.
Set on a stand raised above the snow, with the clearances the manufacturer requires.
Connected, insulated and protected. The opening is then sealed against water, cold air and insects.
A dedicated circuit and an accessible disconnect near the outdoor unit.
Leak test, vacuum, then start-up and a check of heating and cooling.
Remote, modes, filters: we show you the essentials before we leave.
- The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
- The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
- Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
- The wall openingA single opening, with the slope the drain needs to flow outside.
- The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
- Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
- The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
- Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
- The walkthroughRemote, modes, filters: we show you the essentials before we leave.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.
The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.
Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.
A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.
The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.
On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.
The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Clean the indoor unit's filters.
- Clear leaves and debris left on the outdoor unit by winter.
- Test cooling before the first hot days.
- Clean the filters more often when the unit runs a lot.
- Keep plants away from the outdoor unit.
- Check that no water drips from the indoor unit.
- Rake the leaves around the outdoor unit.
- Test heating before the first cold days.
- Book periodic maintenance before winter.
- Keep snow away from the stand and the front of the unit.
- Let the unit defrost: it is normal.
- Never hit the ice on the fins; call us if the unit stays iced up.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. In heating mode, the outdoor unit can produce water.
During defrost cycles. That water must drain away without forming ice.
2. You pick the capacity with a simple square-footage rule.
Windows, insulation, orientation and how the room is used all count. Capacity is chosen on site.
3. A multi-zone connects several indoor heads to a single condenser.
One head per room, all on the same condenser. Each room keeps its own temperature.
4. The disconnect can sit behind the patio furniture.
It must stay accessible: it is what shuts the unit off for service.
0 / 4 right answers
What people ask us about this kind of work
Does a wall-mounted heat pump heat in winter?
Wall-mounted or multi-zone: how do I choose?
Where does the outdoor unit go?
Are there grants?
Do I need a permit?
How cold can it heat?
How much can I save?
How is the LogisVert assistance calculated?
Is it noisy?
The outdoor unit is covered in ice: is that normal?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).