AirGreen's Latest Success: A Seamless Transition to Haxxair
At AirGreen, we pride ourselves on delivering top-notch HVAC services across Montreal, Laval, Longueuil, North Shore, and South Shore. Our recent installation in LaSalle, Montreal, is a testament to our commitment to quality and customer satisfaction.
Why Haxxair?
Haxxair, a brand synonymous with innovation and value, offers a superior HVAC experience. The Haxxair Central Heat Pump we installed is a perfect blend of advanced technology and guaranteed value. Here's why this machine stands out:
- High Efficiency: With a SEER rating of 18.0, it promises lower utility bills without compromising on performance.
- Eco-friendly: Uses R410A refrigerant, ensuring a greener footprint.
- Quiet Performance: Double-layered insulation ensures a quieter indoor environment.
- Reliability: The machine's Four-Speed ECM Blower, Insulated Cabinet, Internal Bracing, and Electric Heating Element ensure longevity and consistent performance.
The Installation Story
Our team recently embarked on a mission in LaSalle, Montreal. The task? A simple replacement of a full central system with the heat pump and electric furnace. But here's what made this installation special:
- Tailored for Quebec Winters: The Haxxair central system undergoes specific adjustments for the Quebec winter, ensuring optimal performance even in the harshest conditions.
- Minimal Service Calls: Thanks to the meticulous verification and adjustments by RBL, the same distributor as Sharp machines, this system requires minimal maintenance.
- Quick After-Sales Experience: RBL's efficiency means we get parts right away, minimizing any machine downtime.
- Customer Satisfaction: Our client was thrilled with the silent and efficient system, further solidified by a 10-year warranty on everything - compressor, parts, and labor.
Technical Specifications
For those who love the nitty-gritty details:
- AHRI: 207036473
- Efficiency: 18.0 SEER, HSPF: 10.0, EER: 10.2
- Voltage: 220V
- Sound Pressure Level (Exterior): 62.0 dB(A)
- Gas (Freon): R-410A
- Pipes: 3/8 - 7/8
- Heating Capacity: -30°C
- Size: 4 Ton
The Federal Grant Advantage
One of the highlights of this installation was the $5000 Federal Grant that the model qualifies for. This not only makes the Haxxair Central Heat Pump an economical choice but also a smart investment for the future.
Why Choose AirGreen?
Our recent installation in LaSalle is just a glimpse of our dedication to quality and customer satisfaction. With AirGreen:
- Experience Matters: Our extensive experience in the HVAC domain ensures that every installation is seamless and efficient.
- Customer First: Our client's feedback from the recent installation speaks volumes about our commitment. The client was not only satisfied but pleasantly surprised by the system's efficiency and silence.
- Warranty: A 10-year warranty on compressor, parts, and labor ensures peace of mind for our customers.
In Conclusion
At AirGreen, every installation is a story of commitment, expertise, and customer satisfaction. Our recent project in LaSalle, Montreal, with the Haxxair Central Heat Pump System, is a testament to our dedication to providing the best HVAC solutions. With winter-specific adjustments, a federal grant, and a 10-year warranty, our clients know they're making the right choice with AirGreen.
The job tools
Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.
Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.
How the job unfolds
The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.
We look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
The equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
Access protected, old unit disconnected and removed when it is being replaced.
Electric furnace or air handler, with its coil, connected to the supply and return ducts.
On a level base, raised above the snow, with free space all around.
Insulated, they enter through a sealed opening and run to the indoor coil.
Dedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
Leak test, vacuum, start-up, airflow check and a test of both modes.
Filter, thermostat, backup heat in extreme cold: what to know before winter.
- The on-site estimateWe look at the ducts, the current indoor module, the electrical panel and the planned spot for the outdoor unit.
- The quoteThe equipment combination, capacity and price, in writing. We check whether the combination qualifies for assistance programs.
- Getting readyAccess protected, old unit disconnected and removed when it is being replaced.
- The indoor moduleElectric furnace or air handler, with its coil, connected to the supply and return ducts.
- The outdoor unitOn a level base, raised above the snow, with free space all around.
- The refrigerant linesInsulated, they enter through a sealed opening and run to the indoor coil.
- Electrical and thermostatDedicated circuits, accessible disconnect, a thermostat that works with the heat pump and the backup heat.
- Tests and start-upLeak test, vacuum, start-up, airflow check and a test of both modes.
- The walkthroughFilter, thermostat, backup heat in extreme cold: what to know before winter.
What we check on a job like this one
Each number is a point we check on site. Switch between summer and winter to watch air and heat move.
In summer, the outdoor unit rejects the house's heat outside.
Generic illustration of this type of installation, not a survey of this job site. Tap a number.
It captures or rejects heat outside. It sits on a level base, above the snow, with free space all around.
The insulated refrigerant lines enter the house through a sealed opening and run to the indoor coil.
A shut-off switch near the outdoor unit isolates it safely for service.
Sitting on the indoor module, it moves heat between the house air and the refrigerant.
Electric furnace or air handler: its fan pushes air through the ducts. The electric backup takes over in extreme cold.
Supply ducts bring air to the rooms; returns bring it back to the unit. Their condition matters as much as the unit's.
It protects the coil and the fan. A dirty filter cuts airflow, so it gets checked regularly.
It runs the heat pump and the backup heat. It must be compatible with the installed system.
Is your home ready?
Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.
Good habits, once the unit is in place
Six simple habits that keep the unit going. Your list stays on this device.
What to do, season by season
Three habits per season for this unit. They take a few minutes and prevent many calls.
- Check the indoor module's filter.
- Clear winter debris from the outdoor unit.
- Test cooling before the heat arrives.
- Check the filter more often in peak season.
- Keep registers and returns clear.
- Watch condensate drainage near the coil.
- Change or clean the filter.
- Test heating and backup heat before the cold.
- Book periodic maintenance.
- Clear snow around the outdoor unit.
- Store nothing in front of the indoor module.
- Note any unusual noise or smell and call us.
The right pages, at the right time
Four statements: true or false?
It all comes down to details you have just seen.
1. A central heat pump uses the house's ducts.
It connects to the existing ducts to heat and cool everywhere.
2. In extreme cold, electric backup heat can take over.
The indoor module (furnace or air handler) works with the heat pump and takes over in extreme cold.
3. The filter only gets changed when the unit breaks down.
A dirty filter cuts airflow. It gets checked regularly.
4. You can reuse the old unit's size without checking.
The house may have changed: insulation, windows, added rooms. Capacity is confirmed on site.
0 / 4 right answers
What people ask us about this kind of work
Can I keep my current ducts?
What happens in extreme cold?
Furnace, air handler, ducted: what is the difference?
Are there grants?
Do I need a permit?
How much can I save?
How is the LogisVert assistance calculated?
Will my current thermostat work?
Central or wall units: which one?
Does AirGreen hold the required licences?
Is the estimate free?
No question matches. Write to us: we answer.
More jobs to see, near you
By town, by equipment or by region: browse more than 4,700 published projects.
Each dot: a town where AirGreen has published projects. The glowing dot: this job.
An on-site estimate, the right capacity, the right equipment.
The on-site estimate is free and the quote follows within 24 hours.
Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).