Installation of a GREE FreeMatch R32 2-Head Wall-Mounted Heat Pump in Rougemont

Chronicle of a project in Rougemont: GREE FreeMatch R32 2-head wall-mounted heat pump, 24,000 BTU/h, SEER2 21, R32 refrigerant with A2L detection. Structural anchoring, compliant disconnect, documented charge weighing. AirGreen, Montérégie.

By AirGreen Climatisation & Chauffage Admin11 min read
City
Region
Equipment
Brand
Challenges
Published
–chapters, to open one by one
11 minto read the whole story
–type of installation
2026year published
At a glance

The job on one screen

Installation of a GREE FreeMatch R32 2-Head Wall-Mounted Heat Pump in Rougemont
Installation of a GREE FreeMatch R32 2-Head Wall-Mounted Heat Pump in Rougemont
The full story

The article, chapter by chapter

When the façade sets the rules: a project chronicle in Montérégie

Rougemont is not Montreal. Winds sweep freely down Mount Rougemont, January nights regularly drop below -25 °C, and old brick houses create constraints that suburban bungalows can ignore. This is exactly the context in which we stepped in to install a GREE FreeMatch R32 2-head system, a multi-zone heat pump capable of heating down to -30 °C without constant electric backup.

This project deserves to be told—not because the equipment is exotic, but because the location of the outdoor unit required three technical decisions that many installers gloss over.

The starting point: two zones, one compressor

The client owned a two-story brick house heated by electric baseboards. Two areas posed problems:

  • The main living room on the ground floor, overheated in summer because of large southwest-facing windows.
  • The upstairs primary bedroom, consistently 4 to 5 degrees warmer than the rest of the house in July, and cold in February.

Installing two independent wall-mounted air conditioners would have meant two outdoor units, two sets of refrigerant lines, two façade penetrations, and two dedicated electrical circuits. On an original brick façade, each additional penetration is an irreversible decision.

The GREE FreeMatch R32 solves this problem with its multi-zone design: a single outdoor unit supplies power and refrigerant to the indoor heads. The indoor units are powered by the outdoor unit, which significantly reduces electrical work inside finished walls—a major advantage in renovations.

The actual technical data of the installed system

Here is what we installed, without rounding:

Item Specification
Outdoor unit GREE FreeMatch R32, GWHD(24)ND6MO
Cooling capacity 7 030 W — 24 000 BTU/h nominal (modulation from 7,500 to 31,400 BTU/h)
Heating capacity 7,030 W — 24,000 BTU/h nominal (up to 31,400 BTU/h)
Efficiency SEER2 21 / HSPF2 10 / EER2 12
Heating range -30°C to 24°C
Cooling range -30°C to 48°C
Refrigerant R32 (A2L), 1,700 g precharged
Precharged length 30 m (98 ft)
Maximum total length 60 m
Maximum elevation difference 15 m
Net weight 51 kg
Certification ENERGY STAR
Warranty 10-year standard

The key point is the modulation range. Between 7,500 and 31,400 BTU/h, the G10 inverter compressor continuously adjusts its speed instead of cycling. In practical terms, on an October evening at 8°C, the unit runs at 25% of its capacity, quietly, without the temperature swings of an on/off system. This is where real comfort is achieved, far more than in the nominal rating.

The three technical decisions made on the project

1. Raise the outdoor unit—and not by 6 inches

In the site photo, the unit rests on galvanized steel wall brackets anchored directly into the load-bearing structure, rather than on a ground base. This choice is not aesthetic.

In Rougemont, snow accumulation at the foot of a north-facing wall can exceed 60 cm, and roofs without snow guards dump their load exactly where one might be tempted to install a base. A buried outdoor unit means:

  • a blocked heat exchanger, resulting in a loss of heating capacity precisely when it is needed;
  • repeated defrost cycles that reduce actual seasonal efficiency;
  • defrost water that freezes beneath the unit and eventually lifts the base.

We therefore mounted the unit high enough, with sufficient clearance beneath the chassis so that defrost water can drain freely and snow can pass through. The brackets are anchored into the foundation, not just into the brick veneer—a common mistake that, with vibrations and freeze-thaw cycles, eventually cracks the veneer.

Mistake to avoid: screwing a heat pump bracket into 4-inch brick veneer without reaching the structure. The brick is not structural. We regularly see this defect during service calls in Montreal, Laval, and the South Shore.

2. Working around the overhanging wooden structure

The unit is installed under a wooden structure—a gallery. This requires two checks that we systematically perform:

  • Clearance above the unit. A blocked vertical air discharge causes air recirculation: the unit draws back in the air it has just cooled (in heating mode), and its efficiency plummets. We always verify the minimum clearance required by the manufacturer before drilling the first anchor hole.
  • Dripping water. An unsealed gallery lets water through and forms ice stalactites on top of the housing. We orient the unit and position the brackets so that water never falls directly onto the top grille.
3. The electrical disconnect within reach

Visible on the right in the image, the outdoor disconnect switch is mounted less than 1 metre from the unit, on the same wall plane, with the cable running downward in a drip loop. This is not decorative: it is a safety requirement that allows a technician to disconnect the power locally without looking for the panel in the basement.

For this model, the MCA is 19.5 A and the maximum overcurrent protection is 25 A at 208/230 V. The circuit breaker and wire gauge are sized based on these values, not an approximation. An undersized circuit shows up as random trips during peak heating, often months after installation — and the customer then blames the heat pump.

R32 and the A2L leak detector: what this means for you

The unit's label clearly displays A2L R32. It is the new refrigerant standard, replacing R410A.

What you need to know in practical terms:

  • R32 has a global warming potential approximately three times lower than R410A, and it is more thermodynamically efficient, which partly explains the SEER2 21 ratings.
  • It is classified as slightly flammable (A2L). This is not a concern during normal use, but it imposes strict rules: ventilation during brazing, compatible tools, and above all, minimum room volumes for each indoor head based on the system charge.
  • GREE includes an A2L leak detection sensor in the system. In the event of a leak, the unit reacts automatically.

This is where the choice of contractor becomes critical. Calculating the charge per room for an A2L system is not optional — installing a high-capacity head in a small enclosed bedroom may violate the manufacturer's requirements. At AirGreen, we validate this point before even proposing a head configuration.

What we have learned from our multi-zone installations in Rougemont and elsewhere in Montérégie

The multi-zone sizing trap

The most common mistake we correct on the South Shore: adding up the BTUs of the indoor heads and assuming that the outdoor unit must match that total.

That is not how a multi-zone system works. The two zones almost never reach their peak simultaneously. A 24,000 BTU/h unit serves two indoor heads very well even when their combined rated capacity exceeds its capacity, because the compressor modulates and redistributes.

Conversely, an oversized system costs more, runs too often at its minimum speed, dehumidifies poorly in summer, and cycles more frequently. Oversizing an air-conditioning system produces a cold, humid home—the worst of both worlds.

We therefore calculate the required charge room by room, considering orientation, glazed area, insulation, infiltration, and floor. In Rougemont, where homes are often older than the housing stock in Longueuil or on the North Shore, air infiltration is the factor that most distorts quick estimates.

Piping length: the detail that costs dearly

The GWHD(24) comes precharged for 30 metres of total piping, with a maximum limit of 60 m and a maximum elevation difference of 15 m. Beyond the precharged length, 20 g of R32 per additional metre must be added.

An installer who does not weigh the additional charge delivers a system that works—for two summers. Then performance collapses for no apparent reason. We always weigh the charge and record the final amount.

Vacuum procedure: non-negotiable

With the R32Residual moisture in the lines is even more damaging than it was with older refrigerants. Cutting a vacuum procedure short by 20 minutes to “finish before the rain” is the silent cause of many of the compressor failures we diagnose three or four years later in equipment installed by others.

We use a micron gauge and verify that the vacuum holds before opening the valves. That's twenty extra minutes on a job site. It's ten years of service life.

Eligibility for financial assistance

The GREE specification sheet indicates that these units are eligible for local rebates, and the system is ENERGY STAR certified. Depending on your situation — the type of heating being replaced, your electricity provider, and the programs in effect when the work is carried out — a multi-zone wall-mounted heat pump may qualify for provincial incentives.

Conditions and amounts change. We never promise a specific amount before validating your file: we verify actual eligibility before the work and provide the installation documentation required for applications.

Our approach, from the first call to commissioning

  1. Visit and load calculation — room by room, not by guesswork.
  2. Head configuration — wall-mounted, ceiling-mounted, console, or ducted, depending on the room and A2L constraints.
  3. Piping route planning — we choose the shortest, least invasive route while preserving the façade.
  4. Installation — supports anchored to the structure, compliant disconnect switch, brazing under nitrogen.
  5. Vacuum evacuation and charge weighing — documented.
  6. Commissioning and customer training — modes, remote control, and filter maintenance.

We serve Rougemont, throughout Montérégie, as well as Montréal, Laval, Longueuil, the North Shore, and the South Shore.

And afterward? Maintenance that protects your investment

A well-maintained inverter system easily lasts more than fifteen years. The steps that matter:

  • Clean the filters on the indoor heads every 4 to 6 weeks during periods of intensive use. A clogged filter reduces airflow, causes the evaporator to freeze, and strains the compressor.
  • Clear snow from the outdoor unit after every significant snowfall, especially from the side grilles.
  • Have the indoor heat exchanger thoroughly cleaned every two to three years. Dust that sticks to the blower wheel is invisible from the filter.
  • Check the pressure and tightness of the connections during an annual professional maintenance service.

A HVAC system is not an appliance you can forget about. It is mechanical equipment that operates 3,000 hours a year.

Are you considering a multi-zone heat pump for your home in Rougemont or elsewhere in Montérégie? Contact us: we will start with a load calculation, not the price.

Your numbers

The job tools

Two quick checks with real numbers: what heat costs, and what your current heaters add up to in BTU/h.

Size checkYour baseboards, in BTU/h
–BTU/h of installed electric heat

    Conversion: 1 W = 3.412 BTU/h. An indication, not a load calculation: baseboards and furnaces are often stronger than the real need, and they can stay as backup. AirGreen confirms the capacity on site.

    The steps

    How the job unfolds

    The main steps of this kind of job at AirGreen. Every house has its quirks: the estimate brings them out.

    Step 1 of 9The on-site estimate

    We look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.

    1. The on-site estimateWe look at the room, the outside wall, the line route and where the outdoor unit will go. That is where the capacity gets chosen.
    2. The quoteModel, capacity and price, in writing. We also check whether the model qualifies for assistance programs.
    3. Getting readyFloors and furniture protected, wall plate position marked level, wall opening located.
    4. The wall openingA single opening, with the slope the drain needs to flow outside.
    5. The outdoor unitSet on a stand raised above the snow, with the clearances the manufacturer requires.
    6. Lines, cable and drainConnected, insulated and protected. The opening is then sealed against water, cold air and insects.
    7. The electrical workA dedicated circuit and an accessible disconnect near the outdoor unit.
    8. Tests and start-upLeak test, vacuum, then start-up and a check of heating and cooling.
    9. The walkthroughRemote, modes, filters: we show you the essentials before we leave.
    The tour

    What we check on a job like this one

    Each number is a point we check on site. Switch between summer and winter to watch air and heat move.

    Generic diagram: wall-mounted heat pump, indoor and outdoor units

    In summer, the outdoor unit rejects the house's heat outside.

    Generic illustration of this type of installation, not a survey of this job site. Tap a number.

    1. Mounted level on a wall plate, high enough for the air to reach the whole room, with enough space around it to slide the filters out easily.

    2. The refrigerant lines, the communication cable and the drain go through the wall in a single opening, sealed against water, cold air and insects.

    3. Two insulated copper pipes connect the two units. Outside, a line cover can protect them from sun, knocks and weather.

    4. A shut-off switch near the outdoor unit isolates it safely for service. It must stay accessible at all times.

    5. The compressor and the fan. In heating mode it captures heat from the outdoor air, even in winter, and moves it inside.

    6. On the ground or on the wall, it keeps the unit above accumulated snow. The unit stays clear and defrost water can drain away.

    7. The fan needs to blow freely. Storage, a fence or a wall too close, and efficiency drops while noise goes up.

    At your place

    Is your home ready?

    Check what applies at your place. A "no" is not a refusal: it is what we sort out during the estimate.

    0 / 6 checked
    Maintenance

    Good habits, once the unit is in place

    Six simple habits that keep the unit going. Your list stays on this device.

    0 / 6 checked
    Through the seasons

    What to do, season by season

    Three habits per season for this unit. They take a few minutes and prevent many calls.

    • Clean the indoor unit's filters.
    • Clear leaves and debris left on the outdoor unit by winter.
    • Test cooling before the first hot days.
    For your project

    The right pages, at the right time

    True or false

    Four statements: true or false?

    It all comes down to details you have just seen.

    1. In heating mode, the outdoor unit can produce water.

    2. You pick the capacity with a simple square-footage rule.

    3. A multi-zone connects several indoor heads to a single condenser.

    4. The disconnect can sit behind the patio furniture.

    Frequently asked questions

    What people ask us about this kind of work

    12 questions
    Does a wall-mounted heat pump heat in winter?
    Yes, it heats and cools. Its capacity drops in very cold weather; the operating range depends on the model and is listed on its spec sheet.
    Wall-mounted or multi-zone: how do I choose?
    One wall head and one condenser outside: the direct solution for a room or an open area. For two to five rooms, a multi-zone puts one head in each room on a single condenser.
    Where does the outdoor unit go?
    Where it stays above the snow, clear and accessible, away from walkways. We decide it with you during the estimate.
    Are there grants?
    Depending on the model and your situation, assistance programs may apply, including Hydro-Québec's LogisVert. AirGreen checks the model number before quoting an amount. See the grants.
    Do I need a permit?
    Rules vary from city to city: location, distances, noise. See permits and by-laws, and we check for your address.
    How cold can it heat?
    It depends on the model. According to Hydro-Québec, newer models work down to a temperature between −15 °C and −25 °C, and some cold-climate models are certified lower. The minimum temperature is on each unit's spec sheet.
    How much can I save?
    Hydro-Québec says a heat pump can be up to three times more efficient than baseboards for heating in the colder months. The result depends on the house, the climate and how it is used.
    How is the LogisVert assistance calculated?
    For ENERGY STAR cold-climate certified heat pumps, Hydro-Québec lists assistance of $120 per 1,000 BTU/h of heating capacity at −8 °C. AirGreen checks the exact model before quoting an amount; only Hydro-Québec confirms the assistance granted. See the grants.
    Is it noisy?
    The sound level depends on the model and is listed in decibels on each unit's spec sheet. Location matters too: when possible, we avoid putting the outdoor unit under a bedroom window.
    The outdoor unit is covered in ice: is that normal?
    Some frost is: the unit runs defrost cycles. Never hit the ice. If the unit stays iced up or stops heating, call us.
    Does AirGreen hold the required licences?
    Yes. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8 Ventilation, 15.10 Refrigeration and 16 Electricity.
    Is the estimate free?
    Yes. The on-site estimate is free and the quote follows within 24 hours. Book my free estimate.

    Could this job help a neighbour?

    Share
    Similar projects

    More jobs to see, near you

    By town, by equipment or by region: browse more than 4,700 published projects.

    Each dot: a town where AirGreen has published projects. The glowing dot: this job.

    All our projects

    Your project

    An on-site estimate, the right capacity, the right equipment.

    The on-site estimate is free and the quote follows within 24 hours.

    • RBQ licence5645-9605-01 · 15.8, 15.10, 16
    • EstimateOn site, free
    • QuoteWithin 24 hours

    Text and photo: a real AirGreen Climatisation & Chauffage job. The diagrams are generic illustrations of the type of installation, not a survey of this job site. Sources of the added figures: airgreen.ca product pages (NEEP / AHRI performance), Hydro-Québec (Heat pumps page, LogisVert, read on 13 October 2026), Régie de l’énergie (rate D as of 1 April 2026).

    Leave a comment