Climate 5000 Regular R-454B
BMS500-AAU012-1AHWXD / BMS500-AAS012-1CSXRD
AHRI 215223298
Lowest published speed: 18 dB(A)
See the product pageThe gist
How much noise at night? What BOSCH, FUJITSU AIRSTAGE, GREE and SHARP publish, speed by speed, for four 12,000 BTU wall heat pumps sold by AirGreen, with AHRI and NEEP certified values and the estimated cost, with no ranking.
For a bedroom, the question always comes back: how much noise at night? Each manufacturer publishes its sound levels its own way. Here is what they publish for four 12,000 BTU wall heat pumps sold by AirGreen, BOSCH, FUJITSU AIRSTAGE, GREE and SHARP, with the AHRI and NEEP certified values and the estimated cost. Shown in alphabetical order of brand, with no ranking.
BMS500-AAU012-1AHWXD / BMS500-AAS012-1CSXRD
AHRI 215223298
Lowest published speed: 18 dB(A)
See the product page
ASUH12KZAS / AOUH12KZAH1
AHRI 214888802
Lowest published speed: 23 dB(A)
Also sold as GENERAL AIRSTAGE.
See the product page
LIV12HP230V1R32AH / LIV12HP230V1R32AO
AHRI 214779350
Lowest published speed: 27 dB(A)
Listed at NEEP in the “Charmo” series.
See the product page
On the left of each line, the lowest published speed for the indoor unit; on the right, the highest. The separate square is the outdoor unit. Tap a brand to read its manufacturer's method.
How to read these figures. dB(A) measures a sound level; the lower the number, the quieter the unit. Each dot is a fan speed published by the manufacturer. GREE publishes only the minimum and maximum.
Why this is not a ranking. Measuring distance, test room and speed differ from one brand to another and are not always published. A gap of a few dB(A) between two different documents says nothing certain.
Measurements taken by each manufacturer using its own method; they are read brand by brand, not against each other.
AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. The four heat pumps are calculated the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. Choose the two models to see in detail; the table of all four follows the same settings.
| Model | Winter · heating | Summer · cooling | Year | Less than baseboards, in winter |
|---|
Heating: certificate HSPF2 Region V; cooling: SEER2. Same nominal size of 12,000 BTU/h for all four.
AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.
Each column measures one thing, under the same test conditions for all four. Tap a header to sort the rows; sorting does not rank the units, it groups one value. The last column cannot be sorted: each record stops at a different temperature.
| Model | Coldest NEEP point | ||||||
|---|---|---|---|---|---|---|---|
| BOSCH Climate 5000 Regular R-454B | 25.5 | 13.00 | 10.6 | 8.0 | 8,400 BTU/h | 2.30 | −25 °C 5,300 BTU/h max. |
| FUJITSU AIRSTAGE ORION XLTH | 30.5 | 16.00 | 12.7 | 10.1 | 16,600 BTU/h | 2.16 | −26.1 °C 12,200 BTU/h max. |
| GREE LIVO R32 | 19.0 | 9.75 | 8.5 | 7.3 | 9,100 BTU/h | 1.80 | −25 °C 6,500 BTU/h max. |
| SHARP ZU1 | 22.0 | 12.50 | 11.0 | 9.0 | 12,000 BTU/h | 2.11 | −27.2 °C 7,200 BTU/h max. |
Bars: same scale for all four in each column. SEER2 and EER2: cooling; HSPF2: heating season, Region IV (temperate) and V (the coldest in the standard); −15 °C: maximum capacity and COP from the NEEP record.
NEEP certifies one last colder point for each model: −25 °C for the BOSCH and the GREE, −26.1 °C for the ORION XLTH, −27.2 °C for the ZU1. Between −15 °C and that point, some manufacturers publish their own tables. Here is everything that exists, model by model, then the chosen pair, degree by degree.
A range is not an estimate: it is the two published values that frame the temperature, each with its source. Manufacturer values are outside the certificate and measured at 21.1 °C indoors.
Only what the manufacturers' documents say, in their own words in quotation marks when they name a feature. “Not stated by the manufacturer” means the documents consulted do not mention it, not that the feature is missing.
The indoor units at the same scale, then the available wall width, then everything the manufacturers publish for installation.




Widths per the manufacturers. Photos from the AirGreen cards, cut out and scaled to their published width.




Width of the unit alone; also allow for the side clearances required by the chosen model's installation manual.
| Installation | BOSCHClimate 5000 Regular R-454B | FUJITSU AIRSTAGEORION XLTH | GREELIVO R32 | SHARPZU1 |
|---|---|---|---|---|
| Max. piping length | 82 ft25 m. Bosch submittal sheet BTC 769208307 C, 01.2026. | 82 ft25 m; minimum 10 ft. Brochure FG8153C. | 66 ft20 m; minimum 10 ft. GREE LIVO R32 submittal sheet. | 66 ft20 m; minimum 9.8 ft. SHARP ZU, ZHU, BU installation manual. |
| Pre-charged length | 24.6 ft7.5 m; add 0.16 oz/ft (15 g/m) beyond. | 49 ft0.22 oz/ft added beyond (manual DR_AS233ES_02, section 7-1). | 25 ftAdd 0.2 oz/ft beyond. | 25 ftStandard length; add 0.16 oz/ft (15 g/m) beyond, installation manual. |
| Max. height difference | 49.2 ft15 m. | 66 ft20 m. | 40 ft | 33 ft10 m. |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 3/8 in | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Outdoor unit W × H × D, weight | 30.12 × 21.85 × 11.93 in, 62.2 lb765 × 555 × 303 mm, 28.2 kg. | 31 7/16 × 24 7/8 × 11 7/16 in, 86 lb799 × 632 × 290 mm, 39 kg. | 28 13/16 × 21 7/8 × 12 63/64 in, 56.2 lb732 × 556 × 330 mm, 25.5 kg. | 30 23/32 × 21 1/4 × 10 19/32 in, 67 lb780 × 540 × 269 mm, 30 kg. ZU1 series page, sharphvac.ca. |
| Indoor unit W × H × D, weight | 31.42 × 11.85 × 9.21 in, 22.9 lb798 × 301 × 234 mm, 10.4 kg. | 38 9/16 × 11 × 9 7/16 in, 28 lb980 × 280 × 240 mm, 12.5 kg. | 32 7/8 × 10 53/64 × 7 7/8 in, 19.8 lb835 × 275 × 200 mm, 9 kg. | 34.6 in wide (879 mm)SHARP installation manual drawing. The ZU1 page on sharphvac.ca gives 41 27/64 in and 31 lb, which do not match this drawing; the ZU series brochure gives 22 lb. |
| Electrical protection | MOP 15 A (MCA 12 A)Bosch submittal sheet. | 15 A breakerBrochure FG8153D. | MOCP 15 A (MCA 12 A)GREE submittal sheet. | Max. fuse 15 AZU1 series page. |
| Dehumidification | 1.1 L/h2.32 US pints/h. | 1.9 L/h4.0 US pints/h per the brochure. | 1.4 L/h2.96 US pints/h. | 1.5 L/h3.2 US pints/h, ZU1 series page. |
| Published heating / cooling range | −25 to 24 °C / −25 to 50 °C | −26 to 24 °C / −10 to 50 °C | −25 to 24 °C / −18 to 48 °C | −27 to 24 °C / −10 to 46 °C |
| Outdoor unit clearances | Not stated by the manufacturerNo clearance in the submittal sheet consulted. | 4 in behind, 4 and 10 in on the sides, 24 in in frontPer FUJITSU AIRSTAGE (installation manual figure). | Not stated by the manufacturerNo clearance in the submittal sheet consulted. | At least 10 in above average snow accumulationSHARP installation manual; the other distances in the drawing are not legible in the document consulted. |
AHRI certificates and NEEP records, read on November 16, 2026. Nothing is highlighted: four columns, the same rows.
| Certified value | BOSCHClimate 5000 Regular R-454B | FUJITSU AIRSTAGEORION XLTH | GREELIVO R32 | SHARPZU1 |
|---|---|---|---|---|
| Cooling, same test conditions | ||||
| Rated cooling capacity at 35 °C | 12,000 BTU/h | 12,000 BTU/h | 12,000 BTU/h | 12,000 BTU/h |
| SEER2 | 25.5 | 30.5 | 19 | 22 |
| EER2 | 13 | 16 | 9.75 | 12.5 |
| Heating, same test conditions | ||||
| HSPF2 Region IV | 10.6 | 12.7 | 8.5 | 11 |
| HSPF2 Region V | 8 | 10.1 | 7.3 | 9 |
| 8.3 °C: capacity min. / rated / max.BTU/h | 4,500 / 12,000 / 15,400 | 3,500 / 16,000 / 23,600 | 3,070 / 12,000 / 12,000 | 3,200 / 14,000 / 17,100 |
| 8.3 °C: COP min. / rated / max. | 5.73 / 3.91 / 3.50 | 5.13 / 4.64 / 3.07 | 5.29 / 3.52 / 3.52 | 6.25 / 3.98 / 2.78 |
| −8.3 °C: capacity min. / rated / max.BTU/h | 4,500 / 10,100 / 10,100 | 2,200 / 10,000 / 18,700 | 2,700 / 9,700 / 11,500 | 3,800 / 14,500 / 14,500 |
| −8.3 °C: COP min. / rated / max. | 2.40 / 2.85 / 2.85 | 3.39 / 3.45 / 2.44 | 3.04 / 2.71 / 2.20 | 3.48 / 2.44 / 2.44 |
| −15 °C: capacity min. / rated / max.BTU/h | 3,600 / 8,400 / 8,400 | 1,950 / 16,600 / 16,600 | 2,600 / 9,100 / 9,100 | 2,950 / 12,000 / 12,000 |
| −15 °C: COP min. / rated / max. | 1.99 / 2.30 / 2.30 | 3.36 / 2.16 / 2.16 | 2.54 / 1.80 / 1.80 | 2.88 / 2.11 / 2.11 |
| Coldest point of each NEEP record — different temperatures, no direct comparison | ||||
| Test temperature | −25 °C (−13 °F) | −26.1 °C (−15 °F) | −25 °C (−13 °F) | −27.2 °C (−17 °F) |
| Capacity min. / max. | 900 / 5,300 BTU/h | 1,400 / 12,200 BTU/h | 1,800 / 6,500 BTU/h | 1,500 / 7,200 BTU/h |
| COP at maximum capacity | 1.60 | 1.81 | 1.42 | 1.80 |
| Certifications and refrigerant | ||||
| ENERGY STAR / cold climate | Yes / YesENERGY STAR directory, ID 3554554 | Yes / YesENERGY STAR directory, ID 3554345 | Yes / YesENERGY STAR directory, ID 4518172 | Yes / YesENERGY STAR directory, ID 3414510 |
| AHRI certificate · NEEP record | 215223298 · 392006 | 214888802 · 392122 | 214779350 · 393211 | 213194987 · 507399 |
| Refrigerant | R-454B · GWP 466 · A2LGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2LGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2LGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2LGWP per the IPCC (AR4); ASHRAE 34 class |
Bar: range between the lowest and highest value in the row; yellow line: rated value. Same scale for all four in each row.
There is no regulatory threshold for a bedroom, and we do not invent one. What can be compared are the published speeds: the lowest ranges from 18 dB(A) (BOSCH, “Si” speed) to 27 dB(A) (GREE LIVO R32), the highest from 42 to 47 dB(A). Each manufacturer measures its own way, and most publish neither the distance nor the test room.
The old article mixed 9,000 and 12,000 BTU, and a comparison only makes sense at the same size. SHARP's ZU1 series starts at 12,000 BTU at AirGreen, so all four are compared at 12,000 BTU/h. The right size for your bedroom is calculated during the estimate visit, based on the room, its windows and its insulation.
They are the four brands the old article named, in a model sold by AirGreen that meets our rules: A2L refrigerant (R-32 or R-454B), AHRI certificate, NEEP record. The R-410A BOSCH Climate 5000 was replaced by its R-454B version, and the R-410A GREE Lomo Plus by the GREE LIVO R32, GREE's entry R-32 line. The four are shown in alphabetical order of brand.
It is published separately: 47 to 56 dB(A) in the documents consulted, often at maximum speed and with no distance stated. Its location, away from bedroom windows, is decided during the estimate visit.
Eligibility depends on Hydro-Québec's list in force on the day of purchase. We check the exact model when preparing the quote.
Terms vary by manufacturer, unit registration and retailer; they are not compared here. The warranty documents for the chosen model come with the quote.
Our estimator visits you for free: they measure the bedroom and the wall, look at where the outdoor unit can go, and you receive a written quote within 24 hours.
Data verified November 16, 2026. Certified values: AHRI certificates read through the NEEP records; declared values: manufacturer documents, cited row by row. Cost: AirGreen estimate, method v1.1 described above.
BOSCH, Climate 5000, FUJITSU AIRSTAGE, GREE, LIVO, SHARP and the model names are trademarks of their respective owners. Logos identify the products only. AirGreen is a retailer; this page is not produced, sponsored or endorsed by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong to you? Write to us at sales@airgreen.ca and we will check it.
An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.