ORION XLTH
ASUH12KZAS / AOUH12KZAH1
AHRI 214888802
Head office: Kawasaki (Kanagawa), Japan
Also sold as GENERAL AIRSTAGE.
See the product pageDoes choosing a Japanese brand change a heat pump's efficiency? The certificate does not mention the brand's country. So we compared, on what can be checked, four 12,000 BTU R-32 wall heat pumps sold by AirGreen: three from Japanese brands and one GREE. AHRI and NEEP values, manufacturer documents, estimated cost. Shown in alphabetical order of brand, with no ranking.
ASUH12KZAS / AOUH12KZAH1
AHRI 214888802
Head office: Kawasaki (Kanagawa), Japan
Also sold as GENERAL AIRSTAGE.
See the product page
GWH12AVDXE-D6DN***/I / GWH12AVDXE-D6DNA1B/O
AHRI 215386290
Head office: Zhuhai (Guangdong), China
GREE AIRY R32: same AHRI certificate.
See the product page
RAK-XJ12PHAA / RAC-XJ12WHAA
AHRI 215911631
Head office: Tokyo, Japan
See the product page
AY-XP12CHU / AE-X12CHU
AHRI 217512736
Head office: Sakai (Osaka), Japan
Black version AY-XP12CHU-B: separate AHRI certificate (217512733).
See the product pageAirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. All four heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards are the reference point. Choose the two models to see in detail; the table of all four follows the same settings.
| Model | Winter · heating | Summer · cooling | Year | Less than with baseboards, winter |
|---|
HITACHI certifies 12,500 BTU/h in cooling; the calculation uses the same nominal size of 12,000 BTU/h for all four. Heating: HSPF2 Region V from the certificate; cooling: SEER2.
AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.
Three of these brands belong to companies headquartered in Japan, the fourth to a Chinese company. The AHRI certificate only knows the model number and tests run under the same standard, AHRI 210/240, for every brand. That is what the diagram shows: four origins, one test bench, four sets of figures.
Company head office according to its own pages (see sources). For HITACHI, the trademark belongs to Hitachi, Ltd.; according to Bosch, Bosch Home Comfort Group has held the licence for air conditioners since 2025. The documents consulted do not state the country of manufacture of the units: it is on the nameplate.
Each column measures one thing, under the same test conditions for all four. Tap a header to sort the rows; sorting does not rank the units, it groups one value. The last column cannot be sorted: each record stops at a different temperature.
| Model | Coldest NEEP point | ||||||
|---|---|---|---|---|---|---|---|
| FUJITSU AIRSTAGE ORION XLTH | 30.5 | 16.0 | 12.7 | 10.1 | 16,600 BTU/h | 2.16 | −26.1 °C 12,200 BTU/h max. |
| GREE EXTRÊME R32 | 29.5 | 15.2 | 10.0 | 8.0 | 12,200 BTU/h | 2.00 | −30 °C 8,500 BTU/h max. |
| HITACHI airHome 800 | 25.0 | 14.5 | 11.5 | 8.7 | 15,200 BTU/h | 2.12 | −30 °C 6,000 BTU/h max. |
| SHARP CHU | 25.0 | 16.0 | 11.0 | 9.0 | 16,000 BTU/h | 2.10 | −30 °C 9,700 BTU/h max. |
Bars: same scale for all four in each column. SEER2 and EER2: cooling; HSPF2: heating season, Region IV (temperate) and V (the coldest in the standard); −15 °C: maximum capacity and COP from the NEEP record.
NEEP certifies a last, colder point for each model: −26.1 °C for the ORION XLTH, −30 °C for the other three. Between −15 °C and that point, some manufacturers publish their own tables. Here is first everything that exists, model by model, then the chosen pair, degree by degree.
A range is not an estimate: it is the two published values that frame the temperature, each with its source. Manufacturer values are outside the certificate and measured at 21.1 °C indoors.
Only what the manufacturers' documents say, in their own words between quotation marks when they name a technology. “Not stated” means the documents consulted do not mention it, not that the feature is absent.
Indoor units, in cooling, as each manufacturer publishes them.
How to read these figures. dB(A) measures a sound level; the lower the figure, the quieter the unit. Each dot is a fan speed published by the manufacturer.
Why this is not a ranking. Measuring distance, test room and fan speed differ from one brand to another, and are not always published. A gap of 1 or 2 dB(A) between two different documents says nothing certain.
Measurements taken by each manufacturer with its own method; read them brand by brand, not against each other.
The indoor units at the same scale, then the wall width available, then everything the manufacturers publish for installation.




Widths per the manufacturers. Manufacturer photos cut out and scaled to their published width.




Width of the unit alone; also allow for the side clearances required by the installation manual of the model chosen.
| Installation | FUJITSU AIRSTAGEORION XLTH | GREEEXTRÊME R32 | HITACHIairHome 800 | SHARPCHU |
|---|---|---|---|---|
| Max. piping length | 82 ft25 m; minimum 10 ft. Brochure FG8153C. | 131.2 ft40 m per the EXTRÊME R32 brochure; the GREE Airy Inverter R32 service manual gives 65.6 ft for the 12,000 BTU, to be confirmed at the quote. | 100 ft30 m, airHome 800 brochure. | 66 ft20 m; minimum 10 ft. SHARP submittal sheet. |
| Pre-charged length | 49 ft0.22 oz/ft added beyond (manual DR_AS233ES_02, section 7-1). | 24.6 ftGREE AIRY R32 brochure and service manual; 0.2 oz/ft added beyond. The EXTRÊME brochure does not give it. | 49 ft15 m, installation manual IA2693:A; 0.11 oz/ft added beyond. | 25 ft0.16 oz/ft (15 g/m) added beyond, SHARP submittal sheet. |
| Max. height difference | 66 ft20 m. | 82 ft25 m per the brochure; 32.8 ft per the service manual. | 65.6 ft20 m. | 33 ft10 m. |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 1/2 in | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Outdoor unit W × H × D, weight | 31 7/16 × 24 7/8 × 11 7/16 in, 86 lb799 × 632 × 290 mm, 39 kg. | 34 3/8 × 21 27/32 × 14 51/64 in, 78.3 lb873 × 555 × 376 mm, 35.5 kg. | 33.46 × 25.59 × 11.73 in, 91 lb850 × 650 × 298 mm, 41 kg. | 30.7 × 21.3 × 10.6 in, 67 lb780 × 540 × 269 mm, 30 kg. |
| Indoor unit W × H × D, weight | 38 9/16 × 11 × 9 7/16 in, 28 lb980 × 280 × 240 mm, 12.5 kg. | 38 3/16 × 13 21/32 × 10 1/8 in, 33.1 lb970 × 347 × 257 mm, 15 kg. | 41.33 × 11.57 × 10.03 in, 30.07 lb1,050 × 294 × 255 mm, 14 kg. HITACHI prints 11.73 in next to 294 mm; 294 mm is 11.57 in. | 41.4 × 12.4 × 9.8 in, 31 lb1,052 × 316 × 249 mm, 14 kg. |
| Electrical protection | 15 A breakerBrochure FG8153D. | MOP 15 A (MCA 11 A)GREE Canada brochure, document 032025. | MOP 25 A (MCA 14 A)airHome 800 brochure, December 2024. | 20 A max. fuse (MCA 15 A)SHARP submittal sheet. |
| Dehumidification | 1.9 L/h4.0 US pints/h per the brochure. | 1.4 L/h2.96 US pints/h per the brochure. | 3.0 L/hPer the airHome 800 brochure. | 0.9 L/h1.9 US pints/h per the submittal sheet. |
| Published heating / cooling range | −26 to 24 °C / −10 to 50 °C | −30 to 30 °C / −29 to 50 °C | −30 to 24 °C / −20 to 46 °C | −30 to 24 °C / −10 to 46 °C |
| Outdoor unit clearances | 4 in behind, 4 and 10 in on the sides, 24 in in frontPer FUJITSU AIRSTAGE (installation manual figure). | Not stated by the manufacturerNo clearances in the brochure or the service manual consulted. | Not stated by the manufacturerNo legible clearances for the 12,000 BTU in the documents consulted. | Not stated by the manufacturerNeither the brochure nor the SHARP submittal sheets publish any. |
AHRI certificates and NEEP records, read November 16, 2026. Nothing is highlighted: four columns, the same rows.
| Certified value | FUJITSU AIRSTAGEORION XLTH | GREEEXTRÊME R32 | HITACHIairHome 800 | SHARPCHU |
|---|---|---|---|---|
| Cooling, same test conditions | ||||
| Rated cooling capacity at 35 °C | 12,000 BTU/h | 12,000 BTU/h | 12,500 BTU/h | 12,000 BTU/h |
| SEER2 | 30.5 | 29.5 | 25 | 25 |
| EER2 | 16 | 15.2 | 14.5 | 16 |
| Heating, same test conditions | ||||
| HSPF2 Region IV | 12.7 | 10 | 11.5 | 11 |
| HSPF2 Region V | 10.1 | 8 | 8.7 | 9 |
| 8.3 °C: capacity min. / rated / max.BTU/h | 3,500 / 16,000 / 23,600 | 3,270 / 12,200 / 16,200 | 4,700 / 12,500 / 19,000 | 3,100 / 16,000 / 22,850 |
| 8.3 °C: COP min. / rated / max. | 5.13 / 4.64 / 3.07 | 5.04 / 4.53 / 3.77 | 2.81 / 3.13 / 3.26 | 5.68 / 4.26 / 3.17 |
| −8.3 °C: capacity min. / rated / max.BTU/h | 2,200 / 10,000 / 18,700 | 2,800 / 13,000 / 13,000 | 4,500 / 11,000 / 16,800 | 5,000 / 18,900 / 18,900 |
| −8.3 °C: COP min. / rated / max. | 3.39 / 3.45 / 2.44 | 4.32 / 2.06 / 2.06 | 1.78 / 2.93 / 2.15 | 2.93 / 2.22 / 2.22 |
| −15 °C: capacity min. / rated / max.BTU/h | 1,950 / 16,600 / 16,600 | 2,600 / 12,200 / 12,200 | 3,500 / 10,500 / 15,200 | 3,850 / 16,000 / 16,000 |
| −15 °C: COP min. / rated / max. | 3.36 / 2.16 / 2.16 | 4.23 / 2.00 / 2.00 | 1.39 / 2.09 / 2.12 | 2.35 / 2.10 / 2.10 |
| Coldest point of each NEEP record — different temperatures, no direct comparison | ||||
| Test temperature | −26.1 °C (−15 °F) | −30 °C (−22 °F) | −30 °C (−22 °F) | −30 °C (−22 °F) |
| Capacity min. / max. | 1,400 / 12,200 BTU/h | 2,600 / 8,500 BTU/h | 1,760 / 6,000 BTU/h | 1,350 / 9,700 BTU/h |
| COP at maximum capacity | 1.81 | 1.75 | 1.06 | 1.80 |
| Certifications and refrigerant | ||||
| ENERGY STAR / cold climate | Yes / YesENERGY STAR directory, ID 3554345 | Yes / YesENERGY STAR directory, ID 3621214 | Yes / YesENERGY STAR directory, ID 3712587 | Yes / YesENERGY STAR directory, ID 4439337 |
| AHRI certificate · NEEP record | 214888802 · 392122 | 215386290 · 389444 | 215911631 · 484774 | 217512736 · 507383 |
| Refrigerant | R-32 · GWP 675 · A2LGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2LGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2LGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2LGWP per the IPCC (AR4); ASHRAE 34 class |
Bar: range between the lowest and highest value in the row; yellow mark: rated value. Same scale for all four on each row.
The brand's country is not a test value. What can be compared are the published points: at −15 °C, the NEEP record gives a maximum of 16,600 BTU/h for the ORION XLTH, 12,200 for the EXTRÊME R32, 15,200 for the airHome 800 and 16,000 for the CHU. Further down, each record stops at a different temperature; the “Extreme cold” section shows them one by one.
The ORION XLTH (KZAH) is the FUJITSU AIRSTAGE model this article already named. For the three other brands, we took a model in the same category: a 12,000 BTU/h R-32 wall heat pump sold by AirGreen, ENERGY STAR cold-climate certified, with a NEEP record that goes down to −30 °C. All four are shown in alphabetical order of brand.
The documents consulted do not say, and neither does the AHRI certificate. So we only give the head office of the company that owns each brand, according to its own pages. The country of manufacture is on the nameplate of the unit delivered.
That is the rated capacity at 35 °C on AHRI certificate 215911631. The estimated cost uses the same nominal size of 12,000 BTU/h for all four, as on all our wall heat pump comparison pages.
Not directly. Each manufacturer measures its own way (distance, fan speed, test room) and does not always publish its method. The values are shown as published, with the method when there is one.
Eligibility depends on the Hydro-Québec list in force on the day of purchase. We check the exact model when we prepare the quote.
Terms vary by manufacturer, unit registration and dealer; they are not compared here. The warranty documents for the model chosen come with the quote.
Our estimator comes to your home, free of charge: he measures the room and the wall, looks at where the outdoor unit can go, and you receive a written quote within 24 hours.
Data verified November 16, 2026. Certified values: AHRI certificates read through the NEEP records; declared values: manufacturer documents, cited row by row. Cost: AirGreen estimate, method v1.1 described above.
FUJITSU, AIRSTAGE, GENERAL, GREE, HITACHI, airHome, SHARP and the model names are trademarks of their respective owners. Logos identify the products only. AirGreen is a dealer; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us at sales@airgreen.ca and we will check it.
An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.