Head to head · Wall air conditioners

Japanese-brand wall heat pump or not: four 12,000 BTU models compared

16 min
Comparison · Wall heat pumps · 12,000 BTU/h

Four wall heat pumps, three Japanese brands: what the certificates show

Does choosing a Japanese brand change a heat pump's efficiency? The certificate does not mention the brand's country. So we compared, on what can be checked, four 12,000 BTU R-32 wall heat pumps sold by AirGreen: three from Japanese brands and one GREE. AHRI and NEEP values, manufacturer documents, estimated cost. Shown in alphabetical order of brand, with no ranking.

R-32 · 12,000 BTU/h4 AHRI certificatesENERGY STAR cold climate: 4 of 4Data verified November 16, 2026
FUJITSU AIRSTAGE ORION XLTH 12,000 BTU (AirGreen image)
FUJITSU AIRSTAGE

ORION XLTH

ASUH12KZAS / AOUH12KZAH1
AHRI 214888802

Head office: Kawasaki (Kanagawa), Japan

Also sold as GENERAL AIRSTAGE.

See the product page
GREE EXTRÊME R32 12,000 BTU (AirGreen image)
GREE

EXTRÊME R32

GWH12AVDXE-D6DN***/I / GWH12AVDXE-D6DNA1B/O
AHRI 215386290

Head office: Zhuhai (Guangdong), China

GREE AIRY R32: same AHRI certificate.

See the product page
HITACHI airHome 800 12,000 BTU (AirGreen image)
HITACHI

airHome 800

RAK-XJ12PHAA / RAC-XJ12WHAA
AHRI 215911631

Head office: Tokyo, Japan

See the product page
SHARP CHU 12,000 BTU (AirGreen image)
SHARP

CHU

AY-XP12CHU / AE-X12CHU
AHRI 217512736

Head office: Sakai (Osaka), Japan

Black version AY-XP12CHU-B: separate AHRI certificate (217512733).

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. All four heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards are the reference point. Choose the two models to see in detail; the table of all four follows the same settings.

Compare in detail:

All four, same method, same settings

ModelWinter · heatingSummer · coolingYearLess than with baseboards, winter

HITACHI certifies 12,500 BTU/h in cooling; the calculation uses the same nominal size of 12,000 BTU/h for all four. Heating: HSPF2 Region V from the certificate; cooling: SEER2.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating 24 hours a day, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the backup electric heat expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: this is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in force April 1, 2026: 7.065¢ per kWh up to 40 kWh per day, 11.142¢ above; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. Access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

The brand and its country

The brand's country is on no certificate

Three of these brands belong to companies headquartered in Japan, the fourth to a Chinese company. The AHRI certificate only knows the model number and tests run under the same standard, AHRI 210/240, for every brand. That is what the diagram shows: four origins, one test bench, four sets of figures.

FUJITSU AIRSTAGEFUJITSU GENERAL LIMITEDKawasaki (Kanagawa), Japan · company founded in 1936
GREEGree Electric Appliances, Inc. of ZhuhaiZhuhai (Guangdong), China · listed on the Shenzhen Stock Exchange
HITACHIHitachi, Ltd. (trademark owner)Tokyo, Japan · HITACHI air conditioners sold under a trademark licence by Bosch Home Comfort Group since 2025
SHARPSharp CorporationSakai (Osaka), Japan · head office according to Sharp

Company head office according to its own pages (see sources). For HITACHI, the trademark belongs to Hitachi, Ltd.; according to Bosch, Bosch Home Comfort Group has held the licence for air conditioners since 2025. The documents consulted do not state the country of manufacture of the units: it is on the nameplate.

The four at a glance

Six certified values, for you to sort

Each column measures one thing, under the same test conditions for all four. Tap a header to sort the rows; sorting does not rank the units, it groups one value. The last column cannot be sorted: each record stops at a different temperature.

ModelColdest NEEP point
FUJITSU AIRSTAGE ORION XLTH30.516.012.710.116,600 BTU/h2.16−26.1 °C 12,200 BTU/h max.
GREE EXTRÊME R3229.515.210.08.012,200 BTU/h2.00−30 °C 8,500 BTU/h max.
HITACHI airHome 80025.014.511.58.715,200 BTU/h2.12−30 °C 6,000 BTU/h max.
SHARP CHU25.016.011.09.016,000 BTU/h2.10−30 °C 9,700 BTU/h max.

Bars: same scale for all four in each column. SEER2 and EER2: cooling; HSPF2: heating season, Region IV (temperate) and V (the coldest in the standard); −15 °C: maximum capacity and COP from the NEEP record.

The six two-model comparisons

Each pair has its own, more detailed page.

ORION XLTHEXTRÊME R32airHome 800CHU
ORION XLTHViewViewView
EXTRÊME R32ViewViewView
airHome 800ViewViewView
Extreme cold

Below −15 °C, every published point, with nothing invented in between

NEEP certifies a last, colder point for each model: −26.1 °C for the ORION XLTH, −30 °C for the other three. Between −15 °C and that point, some manufacturers publish their own tables. Here is first everything that exists, model by model, then the chosen pair, degree by degree.

FUJITSU AIRSTAGE ORION XLTH
16,600 BTU/h at −15 °CNEEP14,920 BTU/h at −20.6 °Cmanufacturer12,200 BTU/h at −26.1 °CNEEPColder no automatic shutdown per FUJITSU AIRSTAGE, capacity not quantified
GREE EXTRÊME R32
12,200 BTU/h at −15 °CNEEP8,500 BTU/h at −30 °CNEEP
HITACHI airHome 800
15,200 BTU/h at −15 °CNEEP13,500 BTU/h at −20 °Cmanufacturer10,500 BTU/h at −25 °Cmanufacturer6,000 BTU/h at −30 °CNEEP
SHARP CHU
16,000 BTU/h at −15 °CNEEP13,800 BTU/h at −20 °Cmanufacturer11,600 BTU/h at −25 °Cmanufacturer11,200 BTU/h at −27.2 °Cmanufacturer9,700 BTU/h at −30 °CNEEP
Compare in detail:

A range is not an estimate: it is the two published values that frame the temperature, each with its source. Manufacturer values are outside the certificate and measured at 21.1 °C indoors.

Features

What each manufacturer writes, feature by feature

Only what the manufacturers' documents say, in their own words between quotation marks when they name a technology. “Not stated” means the documents consulted do not mention it, not that the feature is absent.

Extreme cold
  • FUJITSU AIRSTAGE ORION XLTH Heating published down to −26 °C, with no automatic shutdown (“no lockout”); base pan heater.
  • GREE EXTRÊME R32 Heating published down to −30 °C; 72 W base pan heater, on below 1 °C or during defrost (declared by GREE to NEEP).
  • HITACHI airHome 800 Heating published down to −30 °C; “100% heating capacity at −20 °C”; 150 W base pan heater, on at 0 °C.
  • SHARP CHU Heating published down to −30 °C; heating thermal shutdown at −30 °C per the submittal sheet.
Cooling in cold weather
  • FUJITSU AIRSTAGE ORION XLTH Down to −10 °C outdoors.
  • GREE EXTRÊME R32 Down to −29 °C outdoors.
  • HITACHI airHome 800 Down to −20 °C outdoors.
  • SHARP CHU Down to −10 °C outdoors.
Defrost
  • FUJITSU AIRSTAGE ORION XLTH Automatic defrost function.
  • GREE EXTRÊME R32 Automatic defrost (service manual).
  • HITACHI airHome 800 “Adaptive Defrost Technology”.
  • SHARP CHU Reverse-cycle defrost; “Hot Gas Pipe” against ice at the base of the outdoor unit.
Modes
  • FUJITSU AIRSTAGE ORION XLTH Economy, Energy Saving, Powerful, Minimum Heat, Occupancy.
  • GREE EXTRÊME R32 “G-AI Learning”.
  • HITACHI airHome 800 Smart Eco, SleepSense, weekly timer.
  • SHARP CHU Full Power, Eco, 10 °C (50 °F) function, After Care, OD Silent.
Remote and wall control
  • FUJITSU AIRSTAGE ORION XLTH Backlit remote included; optional wired wall controllers.
  • GREE EXTRÊME R32 YBE1FB1F remote; optional XE-71 wired thermostat.
  • HITACHI airHome 800 RC-BGH1FA0N remote (technical catalogue); airPoint Room H700 controller and third-party thermostat compatible, optional.
  • SHARP CHU Remote control; the “Spot Air” zone is selected from it.
Wi-Fi and app
  • FUJITSU AIRSTAGE ORION XLTH Built-in Wi-Fi; AIRSTAGE Mobile app.
  • GREE EXTRÊME R32 “Wi-Fi connectivity” per the brochure.
  • HITACHI airHome 800 Wi-Fi interface included; airCloud Go app; voice control.
  • SHARP CHU Built-in Wi-Fi adapter (submittal sheet); SHARP AIR app.
Air direction and louvers
  • FUJITSU AIRSTAGE ORION XLTH Automatic vertical direction, manual horizontal direction.
  • GREE EXTRÊME R32 Vertical and horizontal louver swing.
  • HITACHI airHome 800 Not stated in the documents consulted.
  • SHARP CHU Automatic louvers in four directions; “Coanda Airflow”.
Presence detection
  • FUJITSU AIRSTAGE ORION XLTH Occupancy mode.
  • GREE EXTRÊME R32 Not stated in the documents consulted.
  • HITACHI airHome 800 Built-in motion sensor; Smart Eco detects an empty room.
  • SHARP CHU Motion sensor, specific to the CHU series.
Restart and timer
  • FUJITSU AIRSTAGE ORION XLTH Automatic restart.
  • GREE EXTRÊME R32 Low-voltage start; resumes the last settings after a power failure (service manual).
  • HITACHI airHome 800 Configurable restart: resume the last mode or disabled (technical catalogue).
  • SHARP CHU Automatic restart; 24-hour timer and off after 1, 2, 3 or 5 h.
Maintenance and filter
  • FUJITSU AIRSTAGE ORION XLTH Washable filter; ProCore copper coils.
  • GREE EXTRÊME R32 Washable dust filters; fins with anti-corrosion coating.
  • HITACHI airHome 800 PM2.5 activated-carbon filter and stainless pre-filter; FrostWash 3.0; Mold Guard 2.0.
  • SHARP CHU Filter removable without disassembly; “After Care” dries the inside of the unit after shutdown.
Fan speeds
  • FUJITSU AIRSTAGE ORION XLTH Six named speeds, from Quiet to High, plus an automatic mode.
  • GREE EXTRÊME R32 Eight published sound levels, with no speed names.
  • HITACHI airHome 800 Five published speeds: SL, S, M, H and HH.
  • SHARP CHU Five published speeds (airflow and sound), unnamed in the sheet.
Quiet

Published sound levels, fan speed by fan speed

Indoor units, in cooling, as each manufacturer publishes them.

dB

How to read these figures. dB(A) measures a sound level; the lower the figure, the quieter the unit. Each dot is a fan speed published by the manufacturer.

Why this is not a ranking. Measuring distance, test room and fan speed differ from one brand to another, and are not always published. A gap of 1 or 2 dB(A) between two different documents says nothing certain.

Measurements taken by each manufacturer with its own method; read them brand by brand, not against each other.

Installation

On the wall and outside: the real sizes

The indoor units at the same scale, then the wall width available, then everything the manufacturers publish for installation.

Indoor units, same scale

FUJITSU AIRSTAGE ORION XLTH38.56 in wide
Indoor unit ASUH12KZAS to scale
38.56 in · 979 mm
GREE EXTRÊME R3238.19 in wide
Indoor unit GWH12AVDXE-D6DN***/I to scale
38.19 in · 970 mm
HITACHI airHome 80041.33 in wide
Indoor unit RAK-XJ12PHAA to scale
41.33 in · 1,050 mm
SHARP CHU41.42 in wide
Indoor unit AY-XP12CHU to scale
41.42 in · 1,052 mm

Widths per the manufacturers. Manufacturer photos cut out and scaled to their published width.

Is your wall wide enough?

44 in
FUJITSU AIRSTAGE ORION XLTH
GREE EXTRÊME R32
HITACHI airHome 800
SHARP CHU

Width of the unit alone; also allow for the side clearances required by the installation manual of the model chosen.

InstallationFUJITSU AIRSTAGEORION XLTHGREEEXTRÊME R32HITACHIairHome 800SHARPCHU
Max. piping length82 ft25 m; minimum 10 ft. Brochure FG8153C.131.2 ft40 m per the EXTRÊME R32 brochure; the GREE Airy Inverter R32 service manual gives 65.6 ft for the 12,000 BTU, to be confirmed at the quote.100 ft30 m, airHome 800 brochure.66 ft20 m; minimum 10 ft. SHARP submittal sheet.
Pre-charged length49 ft0.22 oz/ft added beyond (manual DR_AS233ES_02, section 7-1).24.6 ftGREE AIRY R32 brochure and service manual; 0.2 oz/ft added beyond. The EXTRÊME brochure does not give it.49 ft15 m, installation manual IA2693:A; 0.11 oz/ft added beyond.25 ft0.16 oz/ft (15 g/m) added beyond, SHARP submittal sheet.
Max. height difference66 ft20 m.82 ft25 m per the brochure; 32.8 ft per the service manual.65.6 ft20 m.33 ft10 m.
Liquid – gas diameters1/4 – 3/8 in1/4 – 1/2 in1/4 – 3/8 in1/4 – 3/8 in
Outdoor unit W × H × D, weight31 7/16 × 24 7/8 × 11 7/16 in, 86 lb799 × 632 × 290 mm, 39 kg.34 3/8 × 21 27/32 × 14 51/64 in, 78.3 lb873 × 555 × 376 mm, 35.5 kg.33.46 × 25.59 × 11.73 in, 91 lb850 × 650 × 298 mm, 41 kg.30.7 × 21.3 × 10.6 in, 67 lb780 × 540 × 269 mm, 30 kg.
Indoor unit W × H × D, weight38 9/16 × 11 × 9 7/16 in, 28 lb980 × 280 × 240 mm, 12.5 kg.38 3/16 × 13 21/32 × 10 1/8 in, 33.1 lb970 × 347 × 257 mm, 15 kg.41.33 × 11.57 × 10.03 in, 30.07 lb1,050 × 294 × 255 mm, 14 kg. HITACHI prints 11.73 in next to 294 mm; 294 mm is 11.57 in.41.4 × 12.4 × 9.8 in, 31 lb1,052 × 316 × 249 mm, 14 kg.
Electrical protection15 A breakerBrochure FG8153D.MOP 15 A (MCA 11 A)GREE Canada brochure, document 032025.MOP 25 A (MCA 14 A)airHome 800 brochure, December 2024.20 A max. fuse (MCA 15 A)SHARP submittal sheet.
Dehumidification1.9 L/h4.0 US pints/h per the brochure.1.4 L/h2.96 US pints/h per the brochure.3.0 L/hPer the airHome 800 brochure.0.9 L/h1.9 US pints/h per the submittal sheet.
Published heating / cooling range−26 to 24 °C / −10 to 50 °C−30 to 30 °C / −29 to 50 °C−30 to 24 °C / −20 to 46 °C−30 to 24 °C / −10 to 46 °C
Outdoor unit clearances4 in behind, 4 and 10 in on the sides, 24 in in frontPer FUJITSU AIRSTAGE (installation manual figure).Not stated by the manufacturerNo clearances in the brochure or the service manual consulted.Not stated by the manufacturerNo legible clearances for the 12,000 BTU in the documents consulted.Not stated by the manufacturerNeither the brochure nor the SHARP submittal sheets publish any.
Certified sheet

All the certified values, side by side

AHRI certificates and NEEP records, read November 16, 2026. Nothing is highlighted: four columns, the same rows.

Certified valueFUJITSU AIRSTAGEORION XLTHGREEEXTRÊME R32HITACHIairHome 800SHARPCHU
Cooling, same test conditions
Rated cooling capacity at 35 °C12,000 BTU/h12,000 BTU/h12,500 BTU/h12,000 BTU/h
SEER230.529.52525
EER21615.214.516
Heating, same test conditions
HSPF2 Region IV12.71011.511
HSPF2 Region V10.188.79
8.3 °C: capacity min. / rated / max.BTU/h3,500 / 16,000 / 23,6003,270 / 12,200 / 16,2004,700 / 12,500 / 19,0003,100 / 16,000 / 22,850
8.3 °C: COP min. / rated / max.5.13 / 4.64 / 3.075.04 / 4.53 / 3.772.81 / 3.13 / 3.265.68 / 4.26 / 3.17
−8.3 °C: capacity min. / rated / max.BTU/h2,200 / 10,000 / 18,7002,800 / 13,000 / 13,0004,500 / 11,000 / 16,8005,000 / 18,900 / 18,900
−8.3 °C: COP min. / rated / max.3.39 / 3.45 / 2.444.32 / 2.06 / 2.061.78 / 2.93 / 2.152.93 / 2.22 / 2.22
−15 °C: capacity min. / rated / max.BTU/h1,950 / 16,600 / 16,6002,600 / 12,200 / 12,2003,500 / 10,500 / 15,2003,850 / 16,000 / 16,000
−15 °C: COP min. / rated / max.3.36 / 2.16 / 2.164.23 / 2.00 / 2.001.39 / 2.09 / 2.122.35 / 2.10 / 2.10
Coldest point of each NEEP record — different temperatures, no direct comparison
Test temperature−26.1 °C (−15 °F)−30 °C (−22 °F)−30 °C (−22 °F)−30 °C (−22 °F)
Capacity min. / max.1,400 / 12,200 BTU/h2,600 / 8,500 BTU/h1,760 / 6,000 BTU/h1,350 / 9,700 BTU/h
COP at maximum capacity1.811.751.061.80
Certifications and refrigerant
ENERGY STAR / cold climateYes / YesENERGY STAR directory, ID 3554345Yes / YesENERGY STAR directory, ID 3621214Yes / YesENERGY STAR directory, ID 3712587Yes / YesENERGY STAR directory, ID 4439337
AHRI certificate · NEEP record214888802 · 392122215386290 · 389444215911631 · 484774217512736 · 507383
RefrigerantR-32 · GWP 675 · A2LGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LGWP per the IPCC (AR4); ASHRAE 34 class

Bar: range between the lowest and highest value in the row; yellow mark: rated value. Same scale for all four on each row.

Questions

Frequently asked questions

Does a Japanese brand heat better in extreme cold?

The brand's country is not a test value. What can be compared are the published points: at −15 °C, the NEEP record gives a maximum of 16,600 BTU/h for the ORION XLTH, 12,200 for the EXTRÊME R32, 15,200 for the airHome 800 and 16,000 for the CHU. Further down, each record stops at a different temperature; the “Extreme cold” section shows them one by one.

Why these four models?

The ORION XLTH (KZAH) is the FUJITSU AIRSTAGE model this article already named. For the three other brands, we took a model in the same category: a 12,000 BTU/h R-32 wall heat pump sold by AirGreen, ENERGY STAR cold-climate certified, with a NEEP record that goes down to −30 °C. All four are shown in alphabetical order of brand.

Where are these units made?

The documents consulted do not say, and neither does the AHRI certificate. So we only give the head office of the company that owns each brand, according to its own pages. The country of manufacture is on the nameplate of the unit delivered.

Why is HITACHI certified at 12,500 BTU/h in cooling?

That is the rated capacity at 35 °C on AHRI certificate 215911631. The estimated cost uses the same nominal size of 12,000 BTU/h for all four, as on all our wall heat pump comparison pages.

Can sound levels be compared from one brand to another?

Not directly. Each manufacturer measures its own way (distance, fan speed, test room) and does not always publish its method. The values are shown as published, with the method when there is one.

Are these models eligible for LogisVert?

Eligibility depends on the Hydro-Québec list in force on the day of purchase. We check the exact model when we prepare the quote.

What about warranties?

Terms vary by manufacturer, unit registration and dealer; they are not compared here. The warranty documents for the model chosen come with the quote.

All four are on the AirGreen site.

Our estimator comes to your home, free of charge: he measures the room and the wall, looks at where the outdoor unit can go, and you receive a written quote within 24 hours.

Sources

Documents consulted

AHRI certificates 214888802, 215386290, 215911631 and 217512736SEER2, EER2, HSPF2 · read through each model's NEEP record
NEEP, Cold Climate Air Source Heat Pump List (ashp.neep.org)Records 392122, 389444, 484774 and 507383 · consulted November 16, 2026
FUJITSU AIRSTAGE, ORION XLTH brochure FG8153CRev. 4/2025 · ranges, % capacity, sound, piping; FG8153D for electrical protection
FUJITSU AIRSTAGE, technical manual DR_AS233ES_02Section 5-2 (capacities at −5 and −15 °F), section 7-1 (charge)
GREE Canada, EXTRÊME R32 brochureDocument 032025 · specifications, ranges, features
GREE, Airy Inverter R32 service manual“Capacity Variation Ratio” curve, piping, defrost, restart
HITACHI, airHome 800 brochure (French and English)Johnson Controls-Hitachi Air Conditioning, December 2024, Canadian edition
HITACHI, 800 series technical catalogue and installation manual IA2693:ASound at 1 m, remote, restart; pre-charged length
SHARP, submittal sheet AE-X12CHU_AY-XP12CHU-EN1January 2026 · capacities below −15 °C, ranges, piping, sound
SHARP, “CHU/CU Series” catalogue MNSPLT-CHUCU 1.1.1Effective January 2026, English · features
ENERGY STAR directory (data.energystar.gov)ID 3554345, 3621214, 3712587 and 4439337
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, art. 2.5
NRCan, HOT2000 climate map, Montréal IntlHeating degree-days and design temperature
FUJITSU GENERAL LIMITED, Corporate Overviewfujitsu-general.com · head office and founding · consulted November 16, 2026
Gree Electric Appliances, Inc. of Zhuhai, 2019 annual reportShenzhen Stock Exchange (szse.cn) · name and head office · consulted November 16, 2026
Bosch Home Comfort Group, “Hitachi Cooling & Heating”bosch-homecomfortgroup.com · brand history and licence · consulted November 16, 2026
Hitachi, Ltd., Corporate Profilehitachi.com · head office in Tokyo, founded in 1910 · consulted November 16, 2026
Sharp Corporation, Corporate Overviewglobal.sharp · head office · consulted November 16, 2026

Going further

You made it to the end.Share it with someone it could help.

Leave a comment