Multi-zone heat pumps

LG multi-zone heat pump: yours and your neighbour’s, Multi F R32 and Multi F LGRED in 2 zones

13 min to read it all

The gist

Two neighbouring houses, two 18,000 BTU LG multi-zones: the Multi F R32 and the Multi F LGRED. What their AHRI certificates say about consumption and capacity in extreme cold, the estimated cost in Montréal, and what depends on the house rather than the unit.

Read the details

In detail

Comparison · LG multi-zone · 2 zones, 18,000 BTU

Two neighbouring houses, two LG multi-zones: the Multi F R32 and the Multi F LGRED

Same brand, same 18,000 BTU/h size, two wall heads on each side. Yet the electricity bill can differ from one house to the next. Here is what the AHRI certificates of these two LG systems say about their consumption, what they show in extreme cold, and what depends on the house instead.

HSPF2 Region IV 9.8 and 9.8 HSPF2 Region V 8.17 and 8.1 SEER2 22.5 and 20.0 Max. at −15 °C 17,700 and 22,000 BTU/h
LG Multi F R32, outdoor unit and two wall heads LG

Multi F R32 · 2 zones

KUMXB181A + two ductless indoor units · AHRI 214848481

View the product page
LG Multi F LGRED R32, outdoor unit and two wall heads LG

Multi F LGRED · 2 zones

KUMXA181A + two ductless indoor units · AHRI 214848473

View the product page

Two LG R-32 outdoor units, each certified with ductless indoor units.

Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference. Both certificates give 18,000 BTU/h of cooling at 35 °C.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 18,000 BTU/h (0 kW) at −23.1 °C, the Montréal design temperature: 0 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 0 kWh of heat for 24-hour heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), heat is reduced in the same proportion, for the heat pump as for the baseboards: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 18,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec rate D in force on April 1, 2026: 7.065 ¢ per kWh up to 40 kWh per day, 11.142 ¢ beyond; the average price, 9.104 ¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The two HSPF2 Region V values are almost identical (8.17 and 8.1): for heating, the estimated gap is a few dollars per winter. Most of the difference comes from cooling, where the SEER2 values are further apart (22.5 and 20.0).

The two houses

The same house, two LGs, one very cold day

A whole season is summed up in the HSPF2. A night at −25 °C comes down to the capacity an outdoor unit can still deliver. Pick a published temperature and your house’s heat loss: each house shows what its LG system publishes at that temperature, and the share that would come from another heat source.

Outdoor temperature (published points only)
−15 °C
estimated house heat needMulti F R32, published max. capacityMulti F LGRED, published max. capacity

Estimated need = chosen heat loss × (18 − outdoor temperature) ÷ (18 − (−23.1)), the same linear assumption as the cost method. It is a scenario: actual heat loss is measured house by house, and how heat is split between the two heads is not certified. Capacities are published maximums, outdoor unit at full speed; nothing is calculated between two published points.

What depends on the house

Why your neighbour’s bill is not yours

Two certificates with almost equal HSPF2 do not produce two equal bills. The certificate measures the unit in a laboratory; the bill measures the house, the installation and how the system is used.

The series on the outdoor unit

“LG multi-zone” covers several series. The number on the outdoor unit’s nameplate (KUMXB181A or KUMXA181A, for example) leads to the AHRI certificate, which gives the HSPF2, the SEER2 and the capacity in extreme cold.

Insulation and airtightness

A house that loses less heat needs fewer hours at full power. The slider in the previous section shows it: the same heat pump covers a small heat loss much further down the thermometer than a large one.

Where the outdoor unit sits

Air must flow freely around the unit, and snow must not bury it. Minimum clearances are given in each outdoor unit’s installation manual.

How the two heads are set

A multi-zone system controls each room separately. An unused room set lower, or a steady setpoint rather than repeated swings, changes how much heat the outdoor unit is asked for.

Filter maintenance

A clogged filter reduces the head’s airflow. LG provides a washable filter on the KNUAB091A wall head; how often to clean it is in the owner’s manual.

Head size and number

A multi-zone certificate covers one combination of indoor units. Larger or more numerous heads than the certified combination do not change the outdoor unit’s capacity; they share it differently.

To go further on the two HSPF2 regions: HSPF2 Region IV and Region V: why two numbers.

Extreme cold

Below −15 °C: every value published by LG and NEEP

Both certificates give a value at −15 °C, at the same temperature: 17,700 and 22,000 BTU/h maximum. Further down, they do not stop at the same point: −20 °C for the Multi F R32, −25 °C for the Multi F LGRED. In between, LG’s performance manual gives a value for the LGRED at −20 °C, outside the certificate.

At −20 °C, the Multi F R32 value comes from the certificate and the LGRED value from LG’s manual: two different sources, to be read side by side, not as a common measurement. Stated ranges in wet bulb, per LG: −4 to +64 °F for the KUMXB181A, −13 to +64 °F for the KUMXA181A.

Features

What LG documents for each system

Both outdoor units connect to the same wall head, the KNUAB091A, so the head’s features are the same on both sides. The differences are outside, in the outdoor unit.

Outdoor unit base pan heater

Multi F R32: optional, accessory PQSH1203. Multi F LGRED: standard.

LG submittal for the KUMXB181A; LG Multi F LGRED engineering manual.
Low-ambient cooling

Multi F R32: down to −10 °C (14 °F). Multi F LGRED: down to −10 °C, or −20 °C (−4 °F) with the optional ZLABGP04A/B wind baffle.

LG submittals for both outdoor units.
Built-in Wi-Fi, LG ThinQ app

Both: yes, in the KNUAB091A head.

LG submittal for the KNUAB091A (January 10, 2025).
R-32 refrigerant leak detector

Both: yes, in the KNUAB091A head.

LG submittal for the KNUAB091A.
3M filter and automatic coil cleaning

Both: yes, 3M Micro Dust filter and the head’s self-cleaning function.

LG submittal for the KNUAB091A.
Auto restart

Both: yes, after a power outage; 3-minute delay when the outdoor unit restarts, per the LGRED submittal.

LG submittals for the KNUAB091A and the KUMXA181A.
Sound

Same head inside, two units outside

Indoor unit, in the room

Both systems use the KNUAB091A head: same figures on both sides.

Outdoor unit, outside

Cooling and heating, at full power, per each LG submittal.

dB

How to read these figures. dB(A) measures a noise level; the lower the number, the quieter. Each dot is a speed or mode published by LG, measured in an anechoic chamber under ISO 3745.

Why this is not a ranking. The noise you hear also depends on distance, the room and where the outdoor unit is placed.

Measurements taken by each manufacturer with its own method: read them separately, not as a ranking. Here, one manufacturer and one method.

Installation

Two outdoor units, two sizes

The Multi F LGRED is taller and heavier outside: 32 27/32 in high and 147.7 lb, against 25 1/2 in and 102.7 lb for the Multi F R32. Drawn to scale from LG’s dimensions.

Multi F R32 · KUMXB181A

Multi F LGRED · KUMXA181A

60 ft

Per LG: at most 82 ft per head and 164 ft in total for both outdoor units; 0.22 oz of R-32 per foot beyond the pre-charged length. The exact length is measured on site.

InstallationMulti F R32Multi F LGRED
Maximum piping length164 ft82 ft per head164 ft82 ft per head
Pre-charged length98.4 ftthen 0.22 oz per foot82 ftthen 0.22 oz per foot
Maximum height difference49.2 ft24.6 ft between the two heads49.2 ft24.6 ft between the two heads
Liquid – gas diametersPer head1/4 – 3/8 in1/4 – 3/8 in
Outdoor unit W × H × D, weight34 5/16 × 25 1/2 × 13 1/16 in, 102.7 lb37 13/32 × 32 27/32 × 13 in, 147.7 lb
Indoor unit, weightKNUAB091A wall head19.7 lb19.7 lb
Electrical protectionPer the manufacturerMOP 20 AMCA 16.1 AMOP 30 AMCA 22.7 A
DehumidificationPer KNUAB091A head1.28 L/h1.28 L/h
Stated heating / cooling range−20 to 18 °C / −10 to 48 °CHeating in wet bulb (−4 to +64 °F)−25 to 18 °C / −10 to 48 °CHeating in wet bulb (−13 to +64 °F)

Clearances around the outdoor unit are given in the installation manual figure for each model; the LG submittals reviewed do not repeat them.

Questions

What people ask us about these two LGs

My LG multi-zone uses less than my neighbour’s. Is it the brand?

Not necessarily. The two LG systems on this page have the same HSPF2 Region IV (9.8) and almost the same HSPF2 Region V (8.17 and 8.1). With certificates this close, the gap between two bills comes mostly from the house (insulation, heat loss), the installation, the settings and maintenance. The exact series still matters in extreme cold: that is where the two certificates part ways.

How do I know which LG series I have?

Read the outdoor unit’s nameplate. KUMXB181A is the 18,000 BTU/h Multi F R32, KUMXA181A the 18,000 BTU/h Multi F LGRED. With that number, the NEEP record and the AHRI certificate give the certified values.

Why does the Multi F R32 have a higher SEER2?

Its AHRI certificate 214848481 gives 22.5, against 20.0 for the Multi F LGRED (AHRI 214848473). SEER2 describes cooling over a season. The certificate does not say why; this page sticks to the values.

What does “cold climate” mean in ENERGY STAR?

It is a U.S. EPA designation for heat pumps that meet performance criteria at −15 °C (5 °F). According to the ENERGY STAR database accessed on November 16, 2026, the Multi F LGRED has it and the Multi F R32 does not. Both are ENERGY STAR certified.

What happens below LG’s stated range?

LG states heating down to −4 °F wet bulb for the KUMXB181A and down to −13 °F for the KUMXA181A, and publishes no capacity below that. The page therefore shows each system’s last published value, with its temperature, and invents nothing beyond it.

Is the estimated cost my bill?

No. It is an estimate made with the same method for both systems, for an 18,000 BTU/h zone in Montréal. It is for comparing; the actual bill depends on the house, the settings and the use.

Can I use heads other than the KNUAB091A?

Yes: LG publishes combination tables for each outdoor unit (14,000 to 24,000 BTU/h of connectable capacity for the KUMXB181A, per LG’s combination manual). The certified values on this page cover ductless wall indoor units.

Certified data

The values of both certificates, line by line

Certified valueMulti F R32Multi F LGRED
Rated capacity at 35 °C18,000 BTU/h18,000 BTU/h
SEER222.520.0
EER213.513.5
HSPF2 Region IV9.89.8
HSPF2 Region V8.178.1
Heating at 8.3 °C (47 °F)
Min. / rated / max. capacity10,080 / 22,000 / 25,000 BTU/h10,248 / 22,000 / 24,000 BTU/h
COP min. / rated / max.5.01 / 3.60 / 3.033.00 / 3.60 / 2.80
Heating at −8.3 °C (17 °F)
Min. / rated / max. capacity6,781 / 14,800 / 20,200 BTU/h7,511 / 13,900 / 23,600 BTU/h
COP min. / rated / max.3.97 / 2.83 / 2.602.50 / 2.59 / 2.56
Heating at −15 °C (5 °F)
Min. / rated / max. capacity5,759 / 15,800 / 17,700 BTU/h6,262 / 19,800 / 22,000 BTU/h
COP min. / rated / max.3.67 / 2.21 / 2.302.16 / 1.85 / 2.25
Coldest point on the certificate
Test temperature−20 °C (−4 °F)−25 °C (−13 °F)
Min. / max. capacity5,200 / 14,800 BTU/h4,636 / 17,830 BTU/h
COP min. / max.3.54 / 2.052.00 / 2.31
Certification
RefrigerantR-32GWP 675 (IPCC, Fourth Assessment Report) · class A2L (ASHRAE 34)R-32GWP 675 (IPCC, Fourth Assessment Report) · class A2L (ASHRAE 34)
ENERGY STAR, cold climateYes; cold climate: noYes; cold climate: yes
AHRI certificate · NEEP record214848481 · 392651214848473 · 392659

“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities and COP at the coldest point: two different temperatures, so nothing is highlighted.

Both are on the AirGreen website.

A question about which LG series suits your house, the number of heads or the piping? Write or call us.

(514) 316-2973Request a quote
Sources

Documents consulted

NEEP, record 392651 (LG, KUMXB181A)AHRI 214848481, ductless indoor units · accessed November 16, 2026
NEEP, record 392659 (LG, KUMXA181A)AHRI 214848473, ductless indoor units · accessed November 16, 2026
ENERGY STAR, heat pump databaseAHRI 214848481 (certified October 6, 2025, cold climate: no) and 214848473 (March 4, 2025, cold climate: yes) · accessed November 16, 2026
LG, KUMXB181A submittalSB_Multi_F_ODU_R32_KUMXB181A_1_26 A · ranges, sound, optional base pan heater, dimensioned drawing (p. 2), electrical protection · accessed November 9, 2026
LG, R32 Multi F and Multi F MAX combination manualCDM_Multi_F-MAX_ODU_R32_05_25 · KUMXB181A piping and connectable capacity (pp. 4, 6 and 7) · accessed November 9, 2026
LG, Multi F and Multi F MAX with LGRED performance data manualPD_Multi_F-MAX_LGRED_ODU_R32_01_26 · p. 759, maximum heating capacity, 9 + 9 combination · accessed November 9, 2026
LG, Multi F and Multi F MAX with LGRED engineering manualKUMXA181A dimensions, weight, piping, base pan heater, ranges · accessed November 9, 2026
LG, KUMXA181A submittalSB_Multi_F_LGRED_ODU_R32_KUMXA181A_1_26A · ranges, sound, restart, ZLABGP04A/B wind baffle, MOP and MCA · accessed November 9, 2026
LG, KNUAB091A wall unit submittalSB_MultiF_HiEff_WallMounted_IDU_R32_KNUAB091A (January 10, 2025) · sound, weight, dehumidification, features · copy hosted by a distributor
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5 · accessed November 16, 2026
NRCan, HOT2000 climate dataMontréal Intl: 4,167 degree-days (base 18 °C), design temperature −23.1 °C
You made it to the end.Share it with someone it could help.

Related questions