T Series · 12,000 BTU/h
Head TSC-GL-12HA2/I3TI23 · outdoor unit TSC-GL-12HA2/I3TO23
AHRI certificate 209457664 · not on the NEEP list
No other name found for this certificate in the documents reviewed.
See the product pageAirGreen lexiconWall-mounted heat pumps
Simplified diagram
This article sets two 12,000 BTU/h wall heat pumps sold by AirGreen side by side: the GENERALLUX T Series, distributed by Manuflow and charged with R-410A, and the GREE VIREO R32. Their AHRI certificates match almost figure for figure; we show what each document proves, from running cost to deep cold, for a 1980s bungalow in Longueuil. Every source is listed at the bottom of the page.
The old article cast GENERALLUX as a small brand up against the big ones. We chose instead to set it next to one specific wall unit of the same size that we also sell: the GREE VIREO R32. At the two AHRI test conditions, 35 °C in cooling and 8.3 °C in heating, they show the same EER2 and the same region IV HSPF2. Everything else happens elsewhere: the refrigerant, the NEEP list, and what each document is willing to put a number on below −15 °C.

Head TSC-GL-12HA2/I3TI23 · outdoor unit TSC-GL-12HA2/I3TO23
AHRI certificate 209457664 · not on the NEEP list
No other name found for this certificate in the documents reviewed.
See the product page
Head VIR12HP230V1R32AH · outdoor unit VIR12HP230V1R32AO
AHRI certificate 214813257 · NEEP listing 392684
Close relative: GREE ENVO R32 12,000, same NEEP series (Clivia), with small differences at 8.3 °C and −8.3 °C.
See the product pageWhere this page comes from. The old article described a 12,000 BTU/h install in a 1980s bungalow in Longueuil, lines run through the crawl space, outdoor unit raised. It also quoted R-32, a SEER of 20.5 and an HSPF of 11.2 that do not match the T Series we sell, which uses R-410A according to its product page, and it set the brand against the big international names without figures. We kept the house and its constraints, and replaced impressions with documents.
Same 12,000 BTU/h zone, same Longueuil house, same Hydro-Québec Rate D, taxes included. Summer is calculated for both with the SEER2 on their AHRI certificate. For winter, our method requires the region V HSPF2 from the certificate: the VIREO R32 has one, while GENERALLUX certificate 209457664 does not. So we leave its heating box empty rather than slip in a figure from another source.
AirGreen method v1.1, November 9, 2026. An estimate compares units under the same conditions; the real bill depends on the house, insulation, settings and use. This amount is not a promise.
An AHRI certificate speaks at two temperatures only. Below freezing, the NEEP list and the manufacturer's documents take over, when they exist. Each line of the chart is a document; each point, a figure it publishes. Move the slider to read, at each temperature, what each file says.
On a small screen, scroll the chart sideways. NEEP search on November 17, 2026 by certificate number (209457664) and by model numbers: no listing for the GENERALLUX T Series 12,000. The "T Series 23 SEER" service manual carries neither a brand nor a model number; its values at 35 °C and 8.3 °C are identical to certificate 209457664, and its head dimensions match our product page. We show it as a clue, never as a certified value.
Between two published temperatures, we show the two values that frame the chosen temperature, without calculating anything between them. A published maximum capacity is not the heat your house needs: it is the most the unit can deliver, according to the document cited.
At −15 °C, NEEP certifies 11,000 BTU/h maximum for the VIREO R32; for the GENERALLUX, the only figure comes from the unbranded service manual: 9,100 BTU/h, outside the certificate. Colder, GREE has a point certified at −30 °C. The T Series manual states a heating range down to −25 °C without putting a number on capacity below −15 °C.
In the old article, the head was mounted in the living room and the lines ran through the crawl space to come out at the back, away from the front of the house. That route makes the line set longer: this is where the two spec sheets differ most. Set the line length to see what each document allows.
Green: length covered by the factory charge. Brand tint: length allowed with added refrigerant. Dotted mark: maximum length in the document. GENERALLUX: spec table of the service manual (its appendix 2 gives 5 m standard and 25 m maximum: two pages of the same manual disagree). VIREO R32: GREE submittal 07302025, 10 ft minimum.
The head mounts on the wall with its plate; the line goes down into the crawl space through a floor penetration.
Two 15 A protections and similar minimum ampacities. The circuit is confirmed with a master electrician.
Published outdoor unit sound level, in dB(A). Neither document states the measuring distance.
Set the clear width of the living room wall. The heads are drawn to the same scale from their published dimensions (diagram); each manufacturer's clearances come on top and are found in its installation manual.
| Installation | GENERALLUX T | VIREO R32 |
|---|---|---|
| Indoor unit W × H × D, weight | 36.22 × 12.05 × 7.68 in26.5 lb gross | 32 31/64 × 11 17/32 × 7 23/32 in20.9 lb net · 25.4 lb gross |
| Outdoor unit W × H × D, weight | 28.66 × 21.65 × 12.01 in64.4 lb gross | 31 37/64 × 21 27/32 × 13 25/32 in67.3 lb net · 72.8 lb gross |
| Maximum piping length | 50 ft15 m, manual spec table | 66 ft10 ft minimum |
| Precharged length | 25 ft+0.22 oz per ft beyond | 25 ft+0.2 oz per ft beyond |
| Maximum height difference | 33 ft | 40 ft |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 1/2 in |
| Electrical protectionminimum circuit ampacity | Max. fuse 15 A11 A | Max. protection 15 A10 A |
| Stated heating / cooling range | −25 to 30 °C / −15 to 55 °C | −30 to 30 °C / −29 to 50 °C |
| Outdoor unit base pan heater | Not stated by the manufacturerthe manual names a "Heater" on the circuit board without describing it | Yes, 72 Wper NEEP; "base pan with electric heater" per GREE |
Sources: "T Series 23 SEER" service manual, 12K 208/230 V column (dimensions and gross weights p. 7, piping and electrical pp. 4-5) and the AirGreen product page for the GENERALLUX; GREE submittal 07302025 for the VIREO R32; base pan heater declared to NEEP. The crawl-space route, the height of the base and the drain path are decided during the visit.
The clearest gap between the two units is the refrigerant. Here is what the documents publish, without drawing any promise from it.
100-year GWP, according to the IPCC Fourth Assessment Report.
ASHRAE 34 designation: A1 for R-410A, non-flammable; A2L for R-32, mildly flammable. A2L units are designed and installed under rules that account for it.
Amount of refrigerant in the outdoor unit, for 25 ft of line.
GENERALLUX: service manual, 1,200 g (the same page prints 35.27 oz in another box; we keep the grams). VIREO R32: GREE submittal 07302025. GWP describes the refrigerant, not the unit: we draw no conclusion about either.
The tags show which document names the feature. When a document is silent, the unit may still have it: the text just does not mention it.
Optional for the GENERALLUX (product page; USB Wi-Fi module per the T Series catalogue); factory-installed on the VIREO R32.
Temperature read at the remote rather than at the head: named by the T Series catalogue and by the GREE submittal.
"Auto restart" in the T Series manual; "Memory / Power Failure Recovery" from GREE.
8 °C heating in the T Series manual; "Freeze Guard" in the GREE submittal.
"Auto-cleaning" in the T Series catalogue; "Auto Clean" from GREE.
Described and declared to NEEP for the VIREO R32 (72 W). The T Series manual does not describe one.
We did not carry over the old article's "up to 30% cheaper", nor its environmental or reliability claims: no document supports them.
How to read these figures. dB(A) measures a sound level weighted the way the ear hears it; the lower the number, the quieter. Each point is a published fan speed. The T Series manual gives five speeds without printing the unit for that row or the method; the GREE submittal gives only the minimum and maximum sound pressure of the head.
Why this is not a ranking. The two documents do not measure the same way and do not publish the same number of speeds: the ranges are read side by side, not as the result of a common test.
GENERALLUX: service manual, in cooling. GREE: submittal 07302025, sound pressure.
GENERALLUX: service manual. GREE: submittal 07302025, sound pressure.
In a bungalow backyard, the distance to the bedroom windows and the base under the unit often matter more than a few decibels.
Because the old article was about GENERALLUX and we sell it. Every GENERALLUX wall unit in our store uses R-410A. Rather than drop it from the page, we set it next to an R-32 wall unit of the same size whose AHRI certificate matches it almost figure for figure, so the gap can be read in the documents.
Our product card says "Distribué par Manuflow" (distributed by Manuflow). The documents reviewed do not name the maker of the T Series and do not say where it is designed or assembled, so we make no claim about it.
According to a fact sheet from the Heating, Refrigeration and Air Conditioning Institute of Canada (HRAI) dated May 2026, importing and using certain R-410A systems is currently allowed in Canada; the association notes that the rules could change. Your project's situation is checked on the date of the quote.
Our heating calculation uses the region V HSPF2 from the AHRI certificate. The GENERALLUX certificate (209457664) gives region IV only, 9.5. The unbranded service manual prints 8.2 for region V: without a certificate, that figure stays in a note, outside the calculation.
From a service manual titled "Air Conditioner Service Manual", distributed by a dealer as "T Series 23 SEER single zone", with no brand and no model number. Its 12K 208/230 V column matches certificate 209457664 exactly for SEER2, EER2 and region IV HSPF2, and its head dimensions match our product page. We use it as a clue, always labelled as outside the certificate.
AirGreen does not sell one of them. FUJITSU AIRSTAGE and SHARP are compared on other pages in our comparison series; here, GREE stands in for the big brands named, with a wall unit of the same size that we sell.
The GREE ENVO R32 12,000 is in the same NEEP series (Clivia) with the same SEER2, EER2 and HSPF2; its capacities differ slightly at 8.3 °C and −8.3 °C. For the GENERALLUX, we found no other name.
Eligibility is checked model by model on the official list of the program concerned, on the date of your project. We give no amount and no promise here. Each manufacturer's warranty documents come with the quote.
| Value | GENERALLUX T · TSC-GL-12HA2/I3TO23 | VIREO R32 · VIR12HP230V1R32AO |
|---|---|---|
| Seasonal efficiency | ||
| SEER2 | 23 | 24.5 |
| EER2 | 13 | 13 |
| HSPF2 region IV | 9.5 | 9.5 |
| HSPF2 region V | Not on the certificate8.2 per the unbranded manual, outside the certificate | 8 |
| Capacity | ||
| Cooling at 35 °C (95 °F)BTU/h, min. / rated / max. | 12,000 ratedAHRI certificate | 2,700 / 12,000 / 15,000 |
| Heating at 8.3 °C (47 °F)BTU/h, min. / rated / max. | 12,000 ratedAHRI certificate | 3,070 / 12,000 / 14,600 |
| Heating at −8.3 °C (17 °F)BTU/h, min. / rated / max. | 7,500 ratedunbranded manual, outside the certificate | 2,700 / 12,000 / 12,000the GREE submittal prints 10,000 at 17 °F |
| Heating at −15 °C (5 °F)BTU/h, min. / rated / max. | 9,100 max.unbranded manual, COP 1.75, outside the certificate | 2,600 / 11,000 / 11,000 |
| COP at 8.3 °Cmin. / rated / max. | ≈ 3.86 rated12,000 ÷ 3,412 ÷ 0.91 kW, unbranded manual, outside the certificate | 5.62 / 3.78 / 3.72 |
| COP at −15 °Cmin. / rated / max. | 1.75 at max.unbranded manual, outside the certificate | 3.17 / 1.95 / 1.95 |
| Coldest published point | ||
| Test temperature | −15 °C (5 °F)unbranded manual | −30 °C (−22 °F)NEEP |
| Capacity at the coldest point | 9,100 BTU/h max. | 2,000 / 7,300 BTU/h min. / max. |
| Certification | ||
| AHRI certificate · NEEP listing | 209457664 · not on the list | 214813257 · 392684 |
| ENERGY STARcold climate | Noper our product page | Yescold climate: yes (NEEP) |
| Refrigerant | R-410AGWP 2,088 (IPCC, AR4) · class A1 | R-32GWP 675 (IPCC, AR4) · class A2L |
"Higher" marks the higher value of the same certified measurement, under the same conditions; it is not a recommendation. Values outside the certificate are never highlighted. Certificate 209457664 was issued on January 16, 2023; we reviewed it in PDF form while preparing this page.
Bungalow, crawl space, backyard: tell us the planned route for the lines and where the outdoor unit will go. The estimate visit is free.
Data checked November 17, 2026. Certified values: AHRI certificates and the NEEP list. Declared values: the documents cited above, always labelled as outside the certificate. The cost is an estimate using the AirGreen method v1.1, described above.
GENERALLUX, Manuflow, GREE, VIREO and ENVO are trademarks of their respective owners. Logos and images are used only to identify the products. AirGreen is a retailer; this page is not produced, sponsored or approved by the manufacturers or distributors.
Photos: AirGreen, for identification.
See something inaccurate? Write to us at sales@airgreen.ca.
An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.