ELIOS vs ZEPHYR wall-mounted heat pump, the technical comparison: EMC and Series 25 R-454B, 12,000 BTU
Side by side
ELIOS EMC and ZEPHYR Series 25, two R-454B wall units
Same refrigerant, same size, two NEEP records listed by two different companies. The ELIOS EMC gives more heat at maximum and has a certified point at −30 °C. The ZEPHYR Series 25 shows a higher COP at full capacity at −8.3 and −15 °C, a higher HSPF2 Region V and a longer line set. Here are their numbers, with no ranking.
Article published on April 6, 2025 · rewritten on November 16, 2026 with the AirGreen comparison-page method.
Series 25 (CB25) R-454B 12,000 BTU
ZE-12CB25I / ZE-12CB25O · AHRI 215414830
See the product pageWhat the electricity costs, in dollars, winter and summer
A 12,000 BTU/h zone in Montréal, heated in winter and cooled in summer, on Hydro-Québec Rate D, taxes included. The calculation is the same for both wall units and for all our comparison pages: only the certified efficiencies change, and here it is HSPF2 Region V that widens the winter gap. Electric baseboards serve as the reference.
How this amount is calculated
- Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h (3.52 kW) at −23.1 °C, Montréal's design temperature: 3.52 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 8,558 kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and for the baseboards alike: a simplification that does not account for the recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the value from the AHRI certificate published by NEEP. Region V is the coldest in the standard, and its calculation includes the backup electric heat expected when the heat pump can no longer keep up. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. {CAPTXT} BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above that; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. Grid access charges, the same with or without a heat pump, are not counted.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, its insulation, the settings and how it is used; this amount is not a promise.
The calculation uses HSPF2 Region V, the coldest in the standard: 9.0 for the ZEPHYR Series 25, 8.0 for the ELIOS EMC. In Region IV, the order flips: 10.5 and 10.0.
At −15 °C, NEEP certifies 11,500 BTU/h for the ELIOS EMC and 11,000 for the ZEPHYR. Lower down, the certified points are not at the same temperature: −30 °C for one, −25 °C for the other.
SEER2 of 24.0 and 23.0; EER2 of 13.2 and 12.25. ELIOS states cooling down to −30 °C outdoors; ZEPHYR, down to −15 °C.
ZEPHYR publishes a 98 ft maximum line set, ELIOS 82 ft; the height limits are close (50 and 49.2 ft). The ELIOS indoor unit is the shorter one: 31.6 in against 33.4.
More heat, or more heat per kWh?
Each dot places a unit at a NEEP-certified temperature: the further right, the more it heats; the higher, the more heat it draws from each kWh (COP). Pick the temperature and the capacity to read: maximum, rated or minimum.
Large dot: the chosen temperature. Small linked dots: the unit's other certified temperatures, from 8.3 °C down to its coldest point.
Values from the NEEP database (records 383644 and 418302, consulted on November 16, 2026), indoors at 21.1 °C. At the coldest point, NEEP publishes the minimum and maximum capacities: the rated reading then goes back to −15 °C, and the coldest point is read at maximum or minimum capacity.
Below −15 °C, every published point, with its source
ELIOS and ZEPHYR both state heating down to −30 °C, but their figures do not fall at the same temperatures. Round dots: NEEP records; diamond: ZEPHYR sheet. Between two published points, the table gives the range; after the last one, it repeats that point and what the manufacturer writes lower down.
What each manufacturer writes, line by line
ELIOS mostly documents safety and accessories (leak detection, optional Wi-Fi thermostat), ZEPHYR mostly comfort modes. Sources: ELIOS EMC brochure (Elios_EMC_202509_FR_V01) and ZEPHYR ZE-12CB25 sheet (BRO_2606). A “Not published” cell means the document is silent, not that the feature is missing.
| Feature | ELIOS EMC | ZEPHYR Series 25 |
|---|---|---|
| Heated base pan | Yes; 150 W per NEEP, on below 3 °C after 25 minutes of heating, for 5-minute periods NEEP record 383644 | Yes; 150 W per NEEP; ZEPHYR also documents a compressor heater NEEP record 418302 and ZEPHYR sheet |
| Wi-Fi control | Optional accessory; ST1S42RW1 Wi-Fi thermostat with MI3C1 interface and 24 V supply ELIOS brochure | Not published by the manufacturer no mention in the ZEPHYR sheet |
| Remote control | Yes ELIOS brochure | Yes; wireless, LED display, 24 h timer ZEPHYR sheet |
| Indoor fan speeds | 5 · turbo, high, medium, low, quiet | 5 · ultra-high, high, medium, low, silence |
| Modes and features named by the manufacturer | “Turbo”, “Quiet”, “Do not disturb”, freeze protection, “Heat+ technology”, refrigerant leak detection sensor | Night, quiet, “iFeel”, quick start, turbo, 8 °C automatic heating, “4D” mode |
| Maintenance and filters | “Active cleaning”, dual filter system | Automatic cleaning |
| Compressor | Inverter model not published | GMCC rotary, DC motors |
| Dehumidification | 1.4 L/h | Not published by the manufacturer |
| Cooling in cold weather | Down to −30 °C outdoors | Down to −15 °C outdoors |
| Stated heating range | −30 to 24 °C | −30 to 24 °C |
The noise of each unit, according to its manufacturer
Indoor unit, published sound pressure
Each dot is a published fan speed. Further left = quieter.
Outdoor unit, published sound pressure
One value per manufacturer.
How to read these numbers. A dB(A) measures a sound level weighted the way the ear hears it; the lower the number, the quieter the unit. Both manufacturers publish five speeds. At the top speed, ELIOS publishes an airflow of 383 CFM and ZEPHYR 394 CFM.
Why this is not a ranking. The ELIOS brochure does not say whether its five values are taken in cooling or heating, and neither document gives the measuring distance. The scales show each manufacturer's stated range, not a side-by-side test.
Measurements taken by each manufacturer with its own method: different method — not comparable point by point.
Units, line set and electrical
The two outdoor units are almost the same width (31.69 and 31 7/8 in); the ZEPHYR one is a little over an inch taller. The outlines come from the published dimensions, at the same scale. The documents consulted show no clearances; the installer follows the manual supplied with the unit.
Outlines to scale: indoor units on top, outdoor units below
| Installation, per the manufacturers' documents | ELIOS EMC | ZEPHYR Series 25 |
|---|---|---|
| Maximum piping length | 82 ft ELIOS brochure | 98 ft minimum 10 ftZEPHYR sheet |
| Precharged length | Not published by the manufacturer precharge of 35.27 oz (1 kg) | 25 ft |
| Maximum height difference | 49.2 ft | 50 ft indoor unit higher |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Outdoor unit W × H × D, weight | 31.69 × 21.81 × 12.99 in, 72.75 lb | 31 7/8 × 23 × 11 in |
| Indoor unit, weight | 31.57 × 11.61 × 7.87 in, 18.96 lb | 33 7/16 × 11 9/16 × 8 1/16 in |
| Electrical protection | Max. fuse 15 A, 208-230 V | MCA 10.5 A · MOP 15 A, 208-230 V |
| Refrigerant and charge | R-454B, 35.27 oz | R-454B, 38.10 oz |
| Stated heating / cooling range | −30 to 24 °C / −30 to 50 °C | −30 to 24 °C / −15 to 48 °C |
What people ask us about these two models
Why the ZEPHYR Series 25, when the original article was about GENERALLUX?
The original article set ELIOS against GENERALLUX. The GENERALLUX wall units AirGreen offers run on R-410A, and our comparisons only set side by side units on A2L refrigerants (R-32 and R-454B). This version keeps ELIOS and compares it with another 12,000 BTU R-454B wall unit sold by AirGreen: the ZEPHYR Series 25.
Which one heats more in extreme cold?
At −15 °C, NEEP certifies 11,500 BTU/h for the ELIOS EMC and 11,000 BTU/h for the ZEPHYR Series 25. Lower down, the points are not at the same temperature: 6,100 BTU/h at −25 °C for the ZEPHYR, 5,900 BTU/h at −30 °C for the ELIOS. Both state heating down to −30 °C.
Why does winter cost less with the ZEPHYR, when the ELIOS gives more heat at maximum?
Capacity says how much heat the unit can deliver; HSPF2 says how much electricity it needs over a season. The AirGreen method uses HSPF2 Region V, the coldest in the standard: 9.0 for the ZEPHYR, 8.0 for the ELIOS. In Region IV, the order flips (10.0 and 10.5). The real difference depends on the house and how it is used.
Does the ELIOS EMC have a twin from another brand?
Its NEEP record publishes the same maximum capacities as the 12,000 BTU MIDEA28's (16,000, 12,800, 11,500 and 5,900 BTU/h); SEER2, EER2, some minimum capacities and COPs differ slightly. Each unit has its own AHRI certificate. We do not present them as identical.
Are these models eligible for Hydro-Québec programs?
Look up each unit's AHRI certificate number on Hydro-Québec's official list: 216046614 for the ELIOS EMC, 215414830 for the ZEPHYR Series 25. This page promises no amount and no eligibility; the list in force on the purchase date is the one that counts.
Why not compare warranties?
Terms vary by manufacturer, registration and dealer. The warranty documents for the unit you choose come with your quote.
AHRI certificate values, published by NEEP
| Certified value | ELIOS EMC | ZEPHYR Series 25 |
|---|---|---|
| Seasonal efficiencies | ||
| SEER2 | 24.0 | 23.0 |
| EER2 | 13.2 | 12.25 |
| HSPF2 Region IV | 10.5 | 10.0 |
| HSPF2 Region V | 8.0 | 9.0 |
| Rated capacity at 35 °C (cooling) | 12,000 BTU/h | 12,000 BTU/h |
| Heating, min. / rated / max. capacity (BTU/h) | ||
| Min. / rated / max. capacity at 8.3 °C | 3,800 / 12,000 / 16,000 | 3,000 / 12,000 / 13,000 |
| Min. / rated / max. capacity at −8.3 °C | 5,200 / 12,000 / 12,800 | 2,550 / 10,800 / 12,000 |
| Min. / rated / max. capacity at −15 °C | 4,000 / 11,500 / 11,500 | 2,000 / 11,000 / 11,000 |
| Min. / rated / max. COP at 8.3 °C | 4.84 / 3.63 / 3.35 | 4.00 / 3.91 / 3.17 |
| Min. / rated / max. COP at −8.3 °C | 2.34 / 2.44 / 1.75 | 3.74 / 2.40 / 2.51 |
| Min. / rated / max. COP at −15 °C | 1.80 / 1.80 / 1.80 | 1.47 / 2.00 / 2.00 |
| Coldest point (different temperatures) | ||
| Test temperature | −30 °C (−22 °F) | −25 °C (−13 °F) |
| Min. / max. capacity at the coldest point | 2,000 / 5,900 BTU/h | 1,000 / 6,100 BTU/h |
| Max. COP at the coldest point | 1.25 | 1.38 |
| Certification | ||
| Refrigerant | R-454B GWP 466 (IPCC AR4), class A2L (ASHRAE 34) | R-454B GWP 466 (IPCC AR4), class A2L (ASHRAE 34) |
| ENERGY STAR · cold climate | Yes NEEP, Nov. 16, 2026 | Yes NEEP, Nov. 16, 2026 |
| AHRI certificate · NEEP record | 216046614 · 383644 | 215414830 · 418302 |
“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation.
Both are on the AirGreen website.
A free estimate visit measures the room, the line-set route and where the outdoor unit can sit, before you choose between the two.
Documents consulted
Data verified on November 16, 2026 (NEEP records, ELIOS brochure and ZEPHYR sheet). Performance: AHRI certificates and the NEEP database. Dimensions, sound, piping and features: per the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails.
Trademarks. ELIOS, ZEPHYR, GENERALLUX and MIDEA are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a dealer of these brands; this article is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us: every reported figure is checked again.