Myth or fact · Wall-mounted heat pumps

Quiet wall heat pump: SHARP ZU1 and MIDEA25 at 12,000 BTU, decibel by decibel

9 min
Comparison · Wall heat pump · 12,000 BTU

SHARP ZU1 and MIDEA25: what the manufacturers publish on noise, and the rest

The original article asked whether a quiet wall heat pump is a myth or a reality. The only verifiable numbers are the ones manufacturers publish, speed by speed. Here are two 12,000 BTU wall units the article named, the SHARP ZU1 and the MIDEA25, with their published sound levels, their AHRI and NEEP certificates and what they cost to run.

Indoor sound, lowest speed23 dB(A)and18 dB(A)
Published outdoor sound50 dB(A)and56 dB(A)
HSPF2 Region V (heating)9.0and8.0
RefrigerantR-32andR-454B
AirGreen product card of the SHARP ZU1 wall heat pump SHARP

ZU1, 12,000 BTU

Indoor AY-XP12ZU1 · outdoor AE-X12ZU1 · AHRI 213194987 · NEEP 507399 See the product page
AirGreen product card of the MIDEA MIDEA25 wall heat pump MIDEA

MIDEA25, 12,000 BTU

Indoor MSEHU-H12B-2A · outdoor MO1ES-H12B-2A · AHRI 215471376 · NEEP 387363 · same NEEP certified values as the BOSCH Climate 5000 Regular R-454B 12,000 (record 392006, separate certificate) See the product page

What sets them apart, in three points

  1. Published soundThe MIDEA25 publishes lower levels at the first four speeds (18 dB(A) at the lowest, against 23 for the ZU1). The ZU1 publishes a lower level at the highest speed and outdoors (50 dB(A) against 56).
  2. Winter and summerHSPF2 Region V of 9.0 for the ZU1 and 8.0 for the MIDEA25: about $340 and $382 per winter (AirGreen estimate, around the clock, average price, taxes included). In summer, SEER2 flips: 22.0 and 25.5.
  3. Extreme coldThe ZU1 is certified down to −27.2 °C (7,200 BTU/h), the MIDEA25 down to −25 °C (5,300 BTU/h); each stops at the heating limit stated by its manufacturer.
The listening bench

Speed by speed, what each manufacturer publishes

Both wall units have five fan speeds. Choose a step: the two columns show the sound level published at that step, from lowest to highest, then the outdoor unit's sound. The two manufacturers do not measure the same way; the gap shown is between two published figures, not a side-by-side measurement.

Indoor unit, every speed

Values published by each manufacturer, from the lowest speed to the highest.

dB

How to read these numbers. dB(A) is a logarithmic scale: a few more decibels are clearly audible. Each point is a published fan speed; lower is quieter.

Why the gap is not exact. SHARP publishes its levels in heating (42 to 23 dB(A) in cooling); MIDEA publishes a single set. Neither states, in the documents consulted, the measuring distance or method: two numbers taken under different conditions do not compare one for one.

At the first four speeds, the MIDEA25 publishes lower figures; at the highest speed and outdoors, the SHARP ZU1 does. These are manufacturer figures, each measured its own way.

Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, on Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the backup electric heat planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above; the average price, 9.104¢, is the one Hydro-Québec's calculators use. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

The gap comes from two numbers on the certificate: HSPF2 Region V (9.0 for the ZU1, 8.0 for the MIDEA25) in winter and SEER2 (22.0 and 25.5) in summer. Each unit's purchase price is on its product page; this page does not compare prices.

Extreme cold

Below −15 °C: every published point, down to the stated limit

NEEP certifies the ZU1 down to −27.2 °C, its stated heating limit (−27 °C), and the MIDEA25 down to −25 °C, also its stated limit. The ZU1 brochure adds two values at −20 and −25 °C.

Hatched areas: beyond each unit's last certified point, which is also the heating limit stated by its manufacturer. The SHARP values at −20 and −25 °C come from the ZU/ZHU brochure (AY-XPC12ZU column), not from the certificate.

Installation

Piping, electrical and size, line by line

Outdoor units drawn to scale from the published dimensions (diagram). A photo of each unit is on its product card, above.

InstallationSHARP ZU1MIDEA25
Maximum piping length65.6 ft (9.8 to 65.6 ft)SHARP ZU/ZHU/BU installation manual82 ftMIDEA brochure, p. 12
Pre-charged length25 ftSHARP installation manual24.6 ftMIDEA brochure, p. 12
Maximum height difference32.8 ft49.2 ft
Liquid – gas diameters1/4 – 3/8 in1/4 – 3/8 in
Indoor unit W × H × D, weight34 39/64 × 11 3/8 × 9 1/64 in, 22 lb31.30 × 11.61 × 8.86 in, 22.93 lb
Outdoor unit W × H × D, weight30 23/32 × 21 1/4 × 10 19/32 in, 67 lb30.12 × 21.85 × 11.93 in, 62.17 lb
Electrical protectionMax. fuse 15 A; MCA not printedSHARP ZU/ZHU brochureMCA 12 A, max. fuse 15 AMIDEA brochure, p. 12
Stated heating / cooling range−27 to 24 °C / −10 to 46 °C−25 to 24 °C / −25 to 50 °C
Outdoor unit sound50 dB(A) heating, 49 cooling56 dB(A)
Features

What each manufacturer names

A feature missing from a document is not necessarily missing from the unit: the document consulted does not mention it.

FeatureSHARP ZU1MIDEA25
Wi-Fi and appYes, built-in Wi-FiZU/ZHU brochureYes, SmartHome appMIDEA brochure, p. 7-8
Outdoor unit heated base panNot stated by the manufacturerfield empty in the NEEP recordYes, 150 WNEEP: below 3 °C in heating
Minimum heat at 8 °C (freeze protection)Not stated by the manufacturerYes
Automatic restartYesNot stated by the manufacturer
DefrostYes, “Hot Gas Pipe”Not stated by the manufacturer
Self-cleaningYes, Plasmacluster and self-cleanYes
Indoor fan speeds5 speeds5 speeds
Air delivery modesMulti Space, Coanda effectTurbo, Silent
Questions

What people ask us about wall unit noise

A quiet wall heat pump: myth or reality?

The manufacturers publish levels around 18 to 23 dB(A) at the lowest speed for these two wall units, and 43 to 46 dB(A) at the highest. Real noise in a room depends on the chosen speed, the room and the installation; published figures are for comparing orders of magnitude.

Why did the numbers in the original article disappear?

The old article presented measurements attributed to our installations, with no documented method or measuring device. This version sticks to the levels published by the manufacturers and to the AHRI and NEEP certificates, which anyone can check.

Why the SHARP ZU1 and the MIDEA25?

The original article named SHARP ZU1 and MIDEA wall units among others. These two 12,000 BTU models are offered by AirGreen, with newer refrigerants (R-32 and R-454B), and their manufacturers publish a sound level for each of the five speeds.

Are the MIDEA25 and the BOSCH Climate 5000 Regular the same thing?

Their NEEP records (387363 and 392006) give exactly the same certified values, under two separate AHRI certificates. We claim nothing beyond what these documents publish.

Is the outdoor unit louder than the indoor unit?

Yes, according to both manufacturers: 49 to 50 dB(A) for the ZU1 and 56 dB(A) for the MIDEA25, against 23 to 46 dB(A) indoors. Think about where it goes, for example away from a bedroom window.

Are these models eligible for LogisVert?

The conditions are in Hydro-Québec's LogisVert participant guide, which can change. To help you sort it out: the NEEP records of the ZU1 12,000 and the MIDEA25 12,000 both say ENERGY STAR and cold climate. Check Hydro-Québec's official list before buying; we do not quote any amount.

Certified data

The certificate values, line by line

Certified valueSHARP ZU1MIDEA25
Certification
AHRI certificate · NEEP record213194987 · 507399215471376 · 387363
RefrigerantR-32R-454B
ENERGY STAR · cold climateYes · yesYes · yes
Seasonal efficiency
SEER222.025.5
EER212.513.0
HSPF2 Region IV11.010.6
HSPF2 Region V9.08.0
Heating, BTU/h and COP
Capacity at 8.3 °C, min. / rated / max.3,200 / 14,000 / 17,1004,500 / 12,000 / 15,400
COP at 8.3 °C, min. / rated / max.6.25 / 3.98 / 2.785.73 / 3.91 / 3.50
Capacity at −8.3 °C, min. / rated / max.3,800 / 14,500 / 14,5004,500 / 10,100 / 10,100
COP at −8.3 °C, min. / rated / max.3.48 / 2.44 / 2.442.40 / 2.85 / 2.85
Capacity at −15 °C, min. / rated / max.2,950 / 12,000 / 12,0003,600 / 8,400 / 8,400
COP at −15 °C, min. / rated / max.2.88 / 2.11 / 2.111.99 / 2.30 / 2.30
Coldest certified point
Test temperature−27.2 °C (−17 °F)−25 °C (−13 °F)
Maximum capacity at this point7,200 BTU/h5,300 BTU/h
Maximum COP at this point1.801.60
Cooling
Rated capacity at 35 °C, min. / rated / max.2,800 / 12,000 / 13,6002,900 / 12,000 / 14,500

“higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation. The coldest-point rows are not marked: the two units are not tested at the same temperature there.

Both are on AirGreen's site.

A question about the ZU1 or the MIDEA25 for a bedroom or an office? Call us or ask for an estimate visit.

Sources

Documents consulted

NEEP, record 507399 (SHARP ZU1 12,000)AHRI 213194987, AY-XP12ZU1 / AE-X12ZU1, “Single Zone series”; consulted November 17, 2026.
NEEP, record 387363 (MIDEA25 12,000)AHRI 215471376, MSEHU-H12B-2A / MO1ES-H12B-2A, MSE series; consulted November 17, 2026.
NEEP, record 392006 (BOSCH Climate 5000 Regular R-454B 12,000)AHRI 215223298; same certified values as record 387363; consulted November 17, 2026.
SHARP, ZU/ZHU brochure (FR, undated)AY-XPC12ZU column: capacities at −15, −20, −25 and −27 °C, ranges, sound, dimensions, features.
SHARP, ZU/ZHU/BU installation manualPiping: 9.8 to 65.6 ft, 25 ft without extra charge, 32.8 ft height difference.
MIDEA Canada, wall heat pump brochure (FR, 2025-08-20)Page 12: ranges, sound, dimensions, piping, electrical; pages 7-8: features.
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5.
NRCan, HOT2000 climate map, Montréal Intl4,167 degree-days base 18 °C; design temperature −23.1 °C.