The AirGreen magazineMarch 2026

Wall-mounted heat pumps

Wall heat pumps and noise: four 12,000 BTU/h models, speed by speed

BOSCH, FUJITSU AIRSTAGE, GREE and MIDEA at 12,000 BTU/h: the sound and airflow of each fan speed, the stated measurement method, the outdoor sound, then the certified figures and the cost in Montréal. No ranking.

By the AirGreen team19 min read
Wall heat pump outdoor unit on a stand, against beige vinyl siding
Comparison · Wall heat pumps · Sound level

The lowest number on a sheet, and what is behind it

A sheet says 19 or 23 dB(A), and that is the number people remember. Yet it belongs to the slowest fan setting, the one that moves the least air, and each manufacturer measures it its own way. Here are four 12,000 BTU/h wall heat pumps sold by AirGreen, from the brands named in the earlier version of this article, in alphabetical order: each published speed with its sound and airflow when the document gives them, what the sheet says about its method, the outdoor-unit sound, then the same certified figures as in our other comparisons.

4 models · 12,000 BTU/hSound and airflow per speedA2L refrigerants: R-32 and R-454BAlphabetical order, no ranking
BOSCH Climate 5000 MAX PERFORMANCE R-454B 12,000 BTU (AirGreen image)
BOSCH

Climate 5000 MAX PERFORMANCE R-454B

Quietest speed: 19.5 dB(A)

BMS500-AAU012-1AHWXD / BMS500-AAS012-1CSXHD · AHRI 215223282

Same AHRI and NEEP certified values as the MIDEA28, the SENVILLE AURA R454B and the DIRECT AIR HEAT XTREME PRO R-454B.

See the product page
FUJITSU AIRSTAGE ORION XLTH 12,000 BTU (AirGreen image)
FUJITSU AIRSTAGE

ORION XLTH

Quietest speed: 23 dB(A)

ASUH12KZAS / AOUH12KZAH1 · AHRI 214888802

See the product page
GREE EXTRÊME R32 12,000 BTU (AirGreen image)
GREE

EXTRÊME R32

Quietest speed: 19 dB(A)

GWH12AVDXE-D6DN***/I / GWH12AVDXE-D6DNA1B/O · AHRI 215386290

Same AHRI and NEEP certified values as the GREE AIRY, the GREE SAPPHIRE and the KINGHOME AIRY; the TOSOT LOMOPLUS changes two of them.

See the product page
MIDEA MIDEA35 12,000 BTU (AirGreen image)
MIDEA

MIDEA35

Quietest speed: 19 dB(A)

MSESU-H12B-2A / MO1SS-H12B-2A · AHRI 215471387

Same AHRI and NEEP certified values as the SENVILLE ELITE.

See the product page

This article was rebuilt on November 17, 2026. It used to publish a “ranking of the quietest models” and quoted levels that do not appear in the manufacturers' documents. It now sets side by side the published figures for the models AirGreen sells in the brands it named: FUJITSU AIRSTAGE ORION XLTH (KZAH series), GREE EXTRÊME R32, BOSCH Climate 5000 MAX PERFORMANCE R-454B and MIDEA35.

Estimated operating cost

What the electricity costs, in dollars, winter and summer

A quieter unit does not cost more or less to run for that reason: the bill follows the certified efficiency. Here is AirGreen's estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included, with the method used on all our comparison pages. Electric baseboards serve as the reference. The cards detail BOSCH and FUJITSU AIRSTAGE, first in alphabetical order; the table below gives all four with the same settings.

All four, with the same settings

How this amount is calculated
  1. Heat to supply over the winter. A zone with a heat loss of 12,000 BTU/h ( kW) at −23.1 °C, Montréal's design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec's air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: this is a maximum, since a variable-speed unit slows down when the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ above; the average price, 9.104¢, is the one used by Hydro-Québec's calculators. GST and QST included. Grid access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Sound and airflow

Quiet has an airflow: each speed, its number and the air it moves

The smallest decibel figure on a sheet belongs to the slowest fan setting. That setting moves less air, so less heat or cooling into the room. Three of the four documents publish the airflow of each speed: the chart places them side by side, one curve per unit. Tap a dot to read the speed.

Tap a dot on the chart.

On the same unit: from the loudest speed to the quietest

Between two speeds in the same document, the measurement method is the same: the gap can be read directly. The decibel is a logarithmic scale: a 10 dB(A) gap means ten times less sound energy, 3 dB(A) about half.

Calculation: sound energy ratio = 10 to the power of (gap in dB ÷ 10). It does not say how the ear perceives the gap, and it does not apply between two brands measured in different ways.

Sources: BOSCH, sheet BTC 769208308 B (01.2026); FUJITSU AIRSTAGE, ORION XLTH brochure FG8153D (rev. 4/2025); GREE Canada, EXTRÊME R32 brochure (document 032025); MIDEA, wall heat pump brochure (2025-08-20), p. 10.

Overview

All four, sound and efficiency on one line

Alphabetical order to start. Sort by any column: the quietest published speed is one number among others.

SEER2, HSPF2, −15 °C and coldest point: AHRI certificates read through NEEP. Advertised range and sound: each manufacturer's document, each with its own method. The coldest point is not measured at the same temperature for all: read each capacity with its temperature.

Extreme cold

The coldest nights: what each unit publishes below −15 °C

The quiet setting is mostly used when the room needs little heat; in extreme cold, capacity is what counts. At −15 °C, all four are certified at the same temperature. Colder, NEEP publishes a last point at −26.1 °C for FUJITSU AIRSTAGE and at −30 °C for BOSCH, GREE and MIDEA. BOSCH also publishes its own table at −20, −25 and −30 °C, and FUJITSU AIRSTAGE a value at −20.6 °C. Between two published values, the page shows the range, with no made-up figure in between.

A filled shape: NEEP-certified value. A hollow shape: manufacturer's value, not certified. When both exist at the same temperature, the certificate prevails in comparisons.

Features

What each document names around night-time comfort

Night modes, a quieter outdoor unit, wall control: what each sheet writes. A dotted tag marks a silent document, not a missing feature.

Measurement methods

Two similar numbers are not always measured the same way

Five speeds for BOSCH, six for FUJITSU AIRSTAGE, eight for GREE, four with figures for MIDEA. Before putting them on the same ruler, look at what each document says about its measurement.

dB

How to read these figures. The A-weighted decibel follows the ear's sensitivity; the lower the figure, the quieter the unit. Each dot is a published fan speed.

Why this is not a ranking. None of the four documents consulted states the distance or the test room for the indoor unit. Only the GREE brochure writes “sound pressure level”; the other three write “sound level” or “noise level” without saying which. Figures taken in different ways do not compare directly.

Each manufacturer measures its own way: these figures place a unit within its own range, they do not decide between the four.
Installation

A quiet unit still needs the right spot

A quiet unit in the wrong place is still in the wrong place. Two checks come first: the free width of the planned wall, and the distance to the outdoor unit compared with what each manufacturer allows.

Is your wall wide enough?

38 in

Scale diagram of each indoor unit's published width. Each installation manual also requires clearances on the sides and to the ceiling: check them before drilling.

Piping length

25 ft

Pre-charged and maximum lengths published by each manufacturer. Beyond the pre-charged length, the installer adds refrigerant according to the manual.

Spec sheets

Four full sheets, sound and airflow included

All four sheets have the same rows in the same order, including sound and airflow per speed. Choose a model.

MeasureBOSCH Climate 5000 MAX PERFORMANCE R-454BSource
Certificate and directories
AHRI certificate · NEEP recordAHRI 215223282 · NEEP 392021NEEP directory, viewed November 17, 2026
Company registered on the certificateBosch Thermotechnology Corp“manufacturer” field of the NEEP record
ENERGY STAR and ENERGY STAR cold climateYes; cold climate: yesNEEP 392021 (ENERGY STAR fields)
RefrigerantR-454B · GWP 466 · A2L classNEEP; GWP: IPCC AR4; class: ASHRAE 34
Published sound and airflow
Indoor fan: sound per speed5 speeds: Turbo 47 · High 36.5 · Medium 32.5 · Low 22 · Silent 19.5 dB(A)BOSCH, submittal sheet BTC 769208308 B (01.2026)
Indoor fan: airflow per speed5 speeds: Turbo 441.4 · High 323.7 · Medium 229.6 · Low 176.6 · Silent 147.2 CFMBOSCH, submittal sheet BTC 769208308 B (01.2026)
Outdoor-unit fan: published soundMaximum: 56 dB(A)BOSCH, submittal sheet BTC 769208308 B (01.2026)
Measurement method statedNot stated (“Noise level”)BOSCH, submittal sheet BTC 769208308 B (01.2026)
Seasonal ratings, same test conditions
SEER225.4NEEP 392021
EER213.4NEEP 392021
HSPF2 Region IV / V10.5 / 8.0NEEP 392021
Certified heating
8.3 °C: min. / rated / max. capacity3,800 / 12,000 / 16,000 BTU/hNEEP 392021, 47 °F
−8.3 °C: min. / rated / max. capacity5,300 / 12,000 / 12,800 BTU/hNEEP 392021, 17 °F
−15 °C: min. / rated / max. capacity4,100 / 11,500 / 11,500 BTU/hNEEP 392021, 5 °F
COP at −15 °C, min. / rated / max.1.72 / 1.80 / 1.80NEEP 392021, 5 °F
Coldest point published by NEEP
Test temperature−30 °C (−22 °F)NEEP 392021
Min. / max. capacity at the coldest point2,000 / 5,900 BTU/hNEEP 392021
COP at the coldest point, min. / max.1.17 / 1.25NEEP 392021
Certified cooling
Min. / rated / max. capacity at 35 °C3,800 / 12,000 / 13,500 BTU/hNEEP 392021, 95 °F
Installation and electrical
Advertised heating / cooling range−30 to 24 °C / −30 to 50 °CBOSCH, submittal sheet BTC 769208308 B (01.2026)
Heated base panYes, 150 WNEEP 392021 (pan heater field)
Maximum piping length82 ftBOSCH, submittal sheet BTC 769208308 B (01.2026)
Pre-charged length24.6 ft (35.27 oz charge), add 0.16 oz/ftBOSCH, submittal sheet BTC 769208308 B (01.2026)
Maximum height difference49.2 ftBOSCH, submittal sheet BTC 769208308 B (01.2026)
Liquid – gas diameters1/4 – 3/8 inBOSCH, submittal sheet BTC 769208308 B (01.2026)
Indoor unit W × H × D, weight31.42 × 11.85 × 9.21 in, 22.93 lbBOSCH, submittal sheet BTC 769208308 B (01.2026)
Outdoor unit W × H × D, weight31.69 × 21.81 × 12.99 in, 72.75 lbBOSCH, submittal sheet BTC 769208308 B (01.2026)
Electrical protectionMCA 15 A (outdoor), max. fuse 15 ABOSCH, submittal sheet BTC 769208308 B (01.2026)
Dehumidification2.53 pints/h (about 1.2 L/h)BOSCH, submittal sheet BTC 769208308 B (01.2026)
Questions

What people ask us about noise

Which model is the quietest?

The page does not say, and that is not a dodge: the four manufacturers do not measure sound the same way, and the lowest number on each sheet belongs to a slow speed that moves little air. Compare each speed with its airflow instead, in the “Sound and airflow” section.

What does 19 dB(A) on a sheet mean?

It is the sound level stated for the slowest fan speed of the indoor unit. The number does not say at what distance or in what room it was taken, and that speed moves much less air than the high speeds.

Can two brands' figures be compared?

Not directly. The same unit measured as sound pressure or sound power, at one metre or another distance, does not give the same number. Between two speeds in the same document, however, the method is the same and the gap can be read.

And the outdoor unit, is that what the neighbours hear?

It is the one outside. The documents give a single outdoor figure or one per mode: 56 dB(A) maximum for BOSCH, 47 in cooling and heating for FUJITSU AIRSTAGE, 55 for GREE, 57.0 at high speed for MIDEA. FUJITSU AIRSTAGE names an outdoor low-noise operating mode, without a figure.

Why did the old ranking disappear?

It relied on levels that do not appear in the manufacturers' documents, and a ranking assumes the figures are measured the same way, which is not the case. The published figures are now side by side, with their source.

Does the location matter as much as the model?

Each manufacturer's document sets the clearances and piping limits; that is what the installer checks on site. For the indoor unit, the page shows the width of each one to scale on a wall.

Do these models qualify for a rebate?

It all depends on the program's official list on the day of the application and on your situation. Check the current Hydro-Québec (LogisVert) or Rénoclimat list before signing.

Do these models exist under other names?

Three of the four do, with the same AHRI and NEEP certified values: the BOSCH MAX PERFORMANCE like the MIDEA28, the SENVILLE AURA R454B and the DIRECT AIR HEAT XTREME PRO R-454B; the GREE EXTRÊME R32 like the GREE AIRY, the GREE SAPPHIRE and the KINGHOME AIRY; the MIDEA35 like the SENVILLE ELITE. The published sound, however, comes from each name's own sheet. The page does not say they are the same unit.

All four are offered by AirGreen.

Tell us where people sleep in the house and where the neighbour's window is: with the room dimensions and the planned wall, our team picks the location with you.

Sources and documents

Where each number comes from

NEEP, record 392021 (BOSCH Climate 5000 MAX PERFORMANCE R-454B 12,000 BTU)AHRI 215223282 · viewed November 17, 2026 NEEP, record 392122 (FUJITSU AIRSTAGE ORION XLTH 12,000 BTU)AHRI 214888802 · viewed November 17, 2026 NEEP, record 389444 (GREE EXTRÊME R32 12,000 BTU)AHRI 215386290 · NEEP series “Airy” · viewed November 17, 2026 NEEP, record 387352 (MIDEA MIDEA35 12,000 BTU)AHRI 215471387 · viewed November 17, 2026 BOSCH, 12K Max Performance wall submittal sheetBTC 769208308 B, 01.2026 · sound and airflow per speed, heating table, piping · viewed November 17, 2026 FUJITSU AIRSTAGE, ORION XLTH brochure (KZAH, French)FG8153D, rev. 4/2025 · sound and airflow per speed, outdoor sound, outdoor low-noise mode · viewed November 17, 2026
FUJITSU AIRSTAGE, design manual DR_AS233ES_02§5-2 · capacity at −5 °F (−20.6 °C) · read November 16, 2026
FUJITSU AIRSTAGE, submittal 12KZAH1Version 20250106A, copy hosted by a distributor · outdoor-unit sound (49 dB(A) in cooling, 47 in heating, anechoic room) · read November 17, 2026
GREE Canada, EXTRÊME R32 brochure (French)Document 032025 · sound per speed, outdoor sound, ranges, dimensions · viewed November 17, 2026 MIDEA, wall heat pump brochure (French)2025-08-20 · p. 8 (features of the MIDEA35, 28 and 25 series), p. 10 (MIDEA35) · viewed November 17, 2026 Hydro-Québec, Electricity RatesIn effect April 1, 2026 · Rate D, section 2.5 · estimated operating cost Natural Resources Canada, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C), −23.1 °C design · viewed November 17, 2026
IPCC Fourth Assessment Report (AR4) and ASHRAE Standard 34100-year GWP: R-32 675, R-454B 466 · A2L safety class