Floor console under a window: FUJITSU AIRSTAGE and ARCOAIRE 12,000 BTU, dimension by dimension

11 min
Comparison · Floor consoles · 12,000 BTU

A console under the window: how the FUJITSU AIRSTAGE and the ARCOAIRE measure up

A floor console is chosen first with a tape measure: height under the sill, width under the window, depth into the room. The two 12,000 BTU consoles compared here, the FUJITSU AIRSTAGE RLFFH and the ARCOAIRE DLFSFA, are the same height to the millimetre. They differ in width, in how they blow air, in whether they can be set into the wall and, outside, in deep cold.

Console height600 mmand600 mm
Width740 mmand700 mm
HSPF2 region V8.6and8.1
Max. capacity at −15 °C (NEEP)15,050and12,000
FUJITSU AIRSTAGE 12,000 BTU floor console, AirGreen product card
FUJITSU AIRSTAGE · R-410A · consoleFUJITSU AIRSTAGE

RLFFH console · 12,000 BTU

AGU12RLF / AOU12RLFFH · AHRI 6937310 · NEEP 438670 See the product page
ARCOAIRE 12,000 BTU floor console, AirGreen product card
ARCOAIRE · R-410A · consoleARCOAIRE

DLFSFA console · 12,000 BTU

DLFSFAH12XAK / DLCSRBH12AAK · AHRI 206350386 · NEEP 406547 See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h room in Montréal, on Hydro-Québec Rate D, taxes included. Both consoles are calculated in exactly the same way, with the same method used on all our comparison pages; only their certified efficiencies change. Electric baseboards, often the ones a console replaces under the window, serve as the reference.

How this amount is calculated
  1. Heat needed over the winter. A room whose heat loss reaches 12,000 BTU/h (3.52 kW) at −23.1 °C, Montréal’s design temperature: 3.52 kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = 8,558 kWh of heat for heating 24 hours a day, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this is a simplification that ignores recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 region V, the value of the AHRI certificate published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup planned for when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes nominal capacity all day: it is a maximum, since a variable-speed unit slows down when the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065 ¢ per kWh up to 40 kWh per day, 11.142 ¢ beyond; the average price, 9.104 ¢, is the one Hydro-Québec’s calculators use. GST and QST included. The access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

Under the window

Is your sill high enough? Is your window wide enough?

Enter the height between the floor and the bottom of your window (the sill), then the window width. Both consoles are drawn to scale, centred under the window, with the dimensions each manufacturer publishes.

From the finished floor to the bottom of the window frame.
Visible width of the frame, side to side.

FUJITSU AIRSTAGE AGU12RLF

    ARCOAIRE DLFSFAH12XAK

      Dimensions: FUJITSU AIRSTAGE 600 × 740 × 200 mm (H × W × D), AGU12RLF submittal; ARCOAIRE 600 × 700 × 210 mm, QuietComfort DLFSFA product sheet. The clearances required around the console are those in each model’s installation manual; they are checked on site, together with the position of the piping and the drain.

      Airflow and mounting

      Where the air comes out, and how the console is mounted

      This is where the two consoles differ most for interior layout: air outlets, mounting into the wall, filters, frost protection. Sources: FUJITSU AIRSTAGE RLFFH brochure (rev. 2/17) and AGU12RLF submittal; QuietComfort DLFSFA and DLCSRB product sheets. A feature missing from a document is not necessarily missing from the unit.

      Air direction (upper and lower louvers)

      FUJITSU AIRSTAGE: two fans, air outlet at the top and bottom; can be set to “upward airflow only” to avoid blowing on feet.

      ARCOAIRE: optional dual top-and-bottom outlet on size 12, or top outlet only.

      Warm air from the bottom warms the floor; upward-only air avoids a draft on the legs.

      Half-recessed into the wall, optional

      FUJITSU AIRSTAGE: “half concealed” wall installation with the UTR-STA kit, per the brochure.

      ARCOAIRE: size 12 is floor-mounted only; no recessed installation is described.

      Recessed, the console projects less into the room; the wall cavity must be free of framing, wires and ducts.

      Filters and panel

      FUJITSU AIRSTAGE: two air-cleaning filters supplied; removable, washable front panel.

      ARCOAIRE: not stated in the pages consulted.

      At 600 mm high, a console’s filter is within reach without a stepladder.

      Frost protection (minimum heat mode)

      FUJITSU AIRSTAGE: “minimum heat” mode that keeps the room at 10 °C.

      ARCOAIRE: heating setback at 8 °C (46 °F).

      Useful for a cottage, a sunroom or a rarely used room.

      Base pan and defrost

      FUJITSU AIRSTAGE: 150 W base heater per the NEEP listing; the brochure describes it as preventing condensate from freezing.

      ARCOAIRE: 150 W base pan heater per the NEEP listing, on below 3 °C under certain conditions.

      Defrost water must drain without freezing under the outdoor unit.

      Auto restart and remote sensing

      FUJITSU AIRSTAGE: not stated in the pages consulted; wireless remote, wired wall control optional.

      ARCOAIRE: auto restart; “Follow Me”, which senses the temperature at the remote.

      Sensing at the remote regulates to where you sit, not to the floor.

      Sound

      Console sound, speed by speed

      A console sits at head height when you are seated. Each manufacturer publishes a sound pressure per fan speed.

      Console (indoor unit)

      Each dot is a published speed, in heating.

      dB

      How to read these figures. dB(A) measures sound as the ear perceives it; the lower the number, the quieter the console. FUJITSU AIRSTAGE publishes four speeds, including “quiet”; ARCOAIRE publishes three.

      Why this is not a ranking. The two documents give a sound pressure without stating the distance or the test room in the same way. Methods not stated the same way — not comparable.

      To compare by ear, the speed used at night matters more than the top speed.

      Deep cold

      Below −15 °C, every published value, at its own temperature

      For each unit, NEEP publishes one point at −15 °C and one colder point: −26.1 °C for the FUJITSU AIRSTAGE, −30 °C for the ARCOAIRE. Between two published points, the value is given as a range.

      FUJITSU AIRSTAGE “More than 73% at −15 °F”

      RLFFH brochure (rev. 2/17): more than 73% of rated heating capacity at −26 °C, on a rated capacity of 16,000 BTU/h.

      NEEP certifies 14,000 BTU/h maximum at −26.1 °C, COP 1.37, or 88% of 16,000. The statement is backed by the certified value.

      Certified

      ARCOAIRE “Up to 69% at −22 °F”

      QuietComfort DLCSRB sheet (2022): a general statement for the outdoor unit series, with no size specified.

      For the 12,000 size, NEEP certifies 5,800 BTU/h maximum at −30 °C, COP 1.08, or 48% of the rated capacity certified at 8.3 °C (12,000). The “up to” statement does not refer to this size in particular.

      Gap to note

      FUJITSU AIRSTAGE publishes its rated heating capacity as 16,000 BTU/h in its brochure; NEEP lists 12,000 BTU/h as the rated capacity certified at 8.3 °C and 19,500 as the maximum. The certificate prevails in any direct comparison.

      Installation

      Piping, outdoor unit and electrical

      The ARCOAIRE accepts a longer line set (82 ft versus 66 ft); the FUJITSU AIRSTAGE accepts a greater height difference between the two units (49 ft versus 32 ft) and publishes a precharged length of 49 ft.

      InstallationFUJITSU AIRSTAGE RLFFHARCOAIRE DLFSFA
      Maximum piping length66 ft (20 m); minimum 10 ftRLFFH brochure, rev. 2/1782 ft (25 m)QuietComfort DLCSRB sheet, 2022
      Precharged length49 ft (15 m)Not published by the manufacturer in the pages consulted
      Maximum height difference49 ft (15 m)32 ft (10 m)
      Liquid – gas diameters1/4 – 3/8 in1/4 – 1/2 in
      Indoor unit (console), dimensions and weight23 5/8 × 29 1/8 × 7 7/8 in (H × W × D), 31 lb23 5/8 × 27 9/16 × 8 1/4 in (H × W × D), 32.4 lb
      Outdoor unit, dimensions and weight24 7/16 × 31 1/8 × 11 7/16 in (H × W × D), 86 lb21 13/16 × 31 11/16 × 13 in (H × W × D), 73.6 lb
      Electrical protectionMCA 11.8 A, max. fuse 15 AMCA 15 A, MOCP 15 A
      Announced heating / cooling range−26 to 24 °C / −10 to 46 °C−30 to 30 °C / −30 to 55 °C
      Questions

      Floor console: the questions that come up

      What sill height is needed for a console under the window?

      Both consoles are 600 mm (23 5/8 in) high. The sill therefore has to be higher than the console, plus the space the installation manual calls for to let air return and allow servicing. The “Under the window” tool above shows the space left for your sill.

      Can a console be recessed into the wall?

      FUJITSU AIRSTAGE describes a half-concealed installation with the UTR-STA kit for the AGU console. The document consulted for the size-12 ARCOAIRE DLFSFA describes floor mounting only. An exterior-wall cavity is checked first: insulation, vapour barrier, framing, wiring.

      Does a console replace an electric baseboard under the window?

      It often goes in the same place and blows warm air near the floor. The cost calculation above compares each console with baseboards for the same room. Whether to keep the baseboard as backup depends on the room’s heat-loss calculation.

      Why does deep-cold heating differ so much?

      The FUJITSU AIRSTAGE RLFFH is the “H” version for very cold climates: NEEP certifies 14,000 BTU/h maximum at −26.1 °C. For the ARCOAIRE, the coldest certified point is at −30 °C, with 5,800 BTU/h maximum. The two values are not at the same temperature.

      Are both eligible for LogisVert?

      Eligibility depends on Hydro-Québec’s official list on the date of the application and on the program’s conditions. Both certificates are listed at NEEP with the ENERGY STAR cold-climate designation. We do not give amounts.

      What about warranties?

      We do not compare warranties on these pages. Each manufacturer’s warranty documents are provided with the quote.

      Certified data

      Both certificates, line by line

      Certified valueFUJITSU AIRSTAGE RLFFHARCOAIRE DLFSFA
      Identification
      AHRI certificate · NEEP listing6937310 · 438670206350386 · 406547
      RefrigerantR-410A (GWP 2,088, IPCC AR4)R-410A (GWP 2,088, IPCC AR4)
      ENERGY STAR · cold climateYesNEEP listingYesNEEP listing
      Seasonal efficiency
      SEER222.723.6
      EER213.113
      HSPF2 region IV1110
      HSPF2 region V8.68.1
      Nominal capacity at 35 °C12,000 BTU/h12,000 BTU/h
      Heating at 8.3 °C (47 °F)
      Capacity min. / nominal / max.3,100 / 12,000 / 19,500 BTU/h3,600 / 12,000 / 15,000 BTU/h
      COP min. / nominal / max.4.54 / 3.23 / 2.184.22 / 3.23 / 3.14
      Heating at −8.3 °C (17 °F)
      Capacity min. / nominal / max.2,457 / 10,600 / 15,000 BTU/h2,300 / 9,600 / 12,900 BTU/h
      COP min. / nominal / max.1.85 / 2.61 / 1.893.37 / 2.56 / 2.2
      Heating at −15 °C (5 °F)
      Capacity min. / nominal / max.2,423 / 13,400 / 15,050 BTU/h1,700 / 12,000 / 12,000 BTU/h
      COP min. / nominal / max.1.82 / 1.9 / 1.92.62 / 1.89 / 1.89
      Coldest point of each listing
      Test temperature−26.1 °C (−15 °F)−30 °C (−22 °F)
      Capacity min. / max.2,252 / 14,000 BTU/h600 / 5,800 BTU/h
      COP min. / max.1.37 / 1.371.17 / 1.08

      “Higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation. The coldest points are at different temperatures and are not compared with each other.

      Both are on AirGreen’s website.

      An estimate visit lets us measure the sill, check the wall and the piping route, and calculate the room’s heat loss before choosing a console.

      (514) 316-2973Request an estimate
      Sources

      Documents consulted

      NEEP, listing 438670 (AHRI 6937310)FUJITSU AIRSTAGE AGU12RLF / AOU12RLFFH · consulted Nov. 17, 2026
      NEEP, listing 406547 (AHRI 206350386)ARCOAIRE DLFSFAH12XAK / DLCSRBH12AAK · consulted Nov. 17, 2026
      FUJITSU AIRSTAGE, Floor Mounted 9RLFFH, 12RLFFH, 15RLFFH brochureno. 6-26-FG2045, rev. 2/17 · consulted Nov. 17, 2026
      FUJITSU AIRSTAGE, AGU12RLF submittal12,000 BTU console, 2 p. · consulted Nov. 17, 2026
      FUJITSU AIRSTAGE, 12RLFFH submittalAOU12RLFFH outdoor unit · consulted Nov. 17, 2026
      QuietComfort DLFSFA product sheet (console)no. 328-12-0488-00 · consulted Nov. 17, 2026
      QuietComfort DLCSRB series sheet (outdoor unit)no. 328-22-0524-02, 2022 · consulted Nov. 17, 2026
      Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5 · consulted Nov. 17, 2026
      NRCan, HOT2000 climate mapMontréal Intl station · consulted Nov. 17, 2026
      You made it to the end.Share it with someone it could help.
      Keep reading

      In the same blog

      AirGreen Climatisation & Chauffage

      From reading to your home.

      An AirGreen advisor assesses your situation on site, free of charge, and gives you a quote within 24 hours.

      • RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16
      • Free on-site estimateAn advisor assesses your needs
      • Quote within 24 hoursClear and detailed