AirGreenAMERISTAR
AMERISTAR · 23 Series · 19 Series · A5HP5The AMERISTAR space at AirGreenSold and installed by AirGreen. Montreal, Laval, Longueuil, the South Shore and the North Shore.
All of AMERISTAR

AMERISTAR · Wall air conditioners

AMERISTAR wall air conditioner

Air conditioner only or 17 Series heat pump? Both share the same sizes and the same sell sheet (92-1047-04). At 12,000 BTU/h, the sheet gives SEER2 17 for the M4TCS17 air conditioner and SEER2 16.5 for the M4THS17 heat pump; the heat pump adds 13,000 BTU/h of nominal heating.

  • Cooling only
  • SEER2 17 to 18
  • M4MCW17 heads
  • 4 sizes, 9,000 to 24,000 BTU/h

Same sizes, two uses

Pick the size: both columns come from sell sheet 92-1047-04.

Size (BTU/h)
12,000 BTU/hM4TCS17 air conditioner17 Series heat pump
SEER21716.5
EER28.78.7
Nominal cooling12,000 BTU/h12,000 BTU/h
Nominal heatingnone13,000 BTU/h
Maximum breaker (sell sheet)15 A15 A
Outdoor unitM4TCS1712A11NAM4THS1712A11NA

Sources: AMERISTAR 17 Series Single Zone sell sheet, 92-1047-04 (© 2024)

The four air conditioners

SizeOutdoor / indoorSEER2EER2Nominal coolingMax. breaker (sell sheet)
9,000 BTU/hM4TCS1709A11NA / M4MCW1709A1N0A17.210.79,100 BTU/h15 A
12,000 BTU/hM4TCS1712A11NA / M4MCW1712A1N0A178.712,000 BTU/h15 A
18,000 BTU/hM4TCS1718A11NA / M4MCW1718A1N0A17.59.317,400 BTU/h20 A
24,000 BTU/hM4TCS1724A11NA / M4MCW1724A1N0A1811.622,000 BTU/h30 A

Swipe the table to see every column.

Air conditioner or 17 Series heat pump

Values from sell sheet 92-1047-04, size by size.

SizeSEER2 · air conditionerSEER2 · 17 SeriesEER2 · air conditionerEER2 · 17 Series
9,000 BTU/h17.217.510.710.2
12,000 BTU/h1716.58.78.7
18,000 BTU/h17.5169.39.5
24,000 BTU/h181811.611.6

Swipe the table to see every column.

Did you know?

The published cooling range runs from -18°C to 46°C.

Installer's guide 88-M4MHW17-1B-EN

The list of heads approved for the 19 Series multi-zone holds heat pump heads only: no M4MCW air conditioner head is on it.

Sell sheet 92-7323-03, p. 2

Frequently asked questions

Does the wall air conditioner heat?

No: the M4TCS17 provides cooling only. To heat at the same size, you need the 17 Series heat pump (M4THS17): 13,000 BTU/h of nominal heating at 12,000 BTU/h.

Which breaker is needed?

Per the sell sheet: 15 A for the 9,000 and 12,000 air conditioners, 20 A for the 18,000, 30 A for the 24,000. The 24,000 air conditioner's submittal gives 20 A; the nameplate of the installed air conditioner is what counts.

Does the air conditioner always run at full power?

No: according to its submittal, the 24,000 cools from 5,289 to 25,249 BTU/h at 35°C (95°F) outdoors.

What AirGreen does

  • An on-site assessment before the quote: the size is chosen in your home, not from a spec sheet.
  • Installation by our technicians: connections, start-up and a walkthrough included.
  • Montreal, Laval, Longueuil, the South Shore and the North Shore.

Sold and installed by AirGreen.

AMERISTAR limited warranty (GW-600-2100A): 5 years on all parts, or 10 years (original purchaser) if the product is registered within 60 days of installation. Labour is not covered by the manufacturer. It applies to products installed in a residential or multi-family application.

Sources

  1. AMERISTAR 17 Series Single Zone sell sheet, 92-1047-04 · © 2024
  2. M4MCW1709A to M4MCW1724A submittals, SUB-1A (air conditioners) · June 3, 2022
  3. Installer's guide 88-M4MHW17-1B-EN · Mar. 16, 2023
  4. AMERISTAR 19 Series Multi Zone sell sheet, 92-7323-03 · © 2024
  5. AMERISTAR ductless systems limited warranty, GW-600-2100A · © 2020

Sources read on Nov. 5, 2026.