AirGreenFORESTAIR
FORESTAIR · E24 · MZ · E-TECH+FORESTAIR at AirGreenSold and installed by AirGreen. We install in Montréal, Laval, Longueuil, on the South Shore and on the North Shore.
All of FORESTAIR
Updated November 11, 2026
E-TECH+ electric furnaces · FORESTAIR

FORESTAIR E-TECH+ electric furnace: the air handler, its space and its airflow

The E-TECH+ air handler measures 500 × 1,180 × 550 mm (2 and 3 tons) or 560 × 1,385 × 610 mm (4 and 5 tons); the submittals publish the heating and cooling of the system it forms with the outdoor unit. Each product page in this collection names these two units under one AHRI number. Backup electric heat, optional per the brochure, is discussed at the on-site assessment. Each tonnage’s heat at −15 °C and −25 °C: E-TECH+ central heat pumps

4products in this collection, one per tonnage, from 2 to 5
5ECM blower speeds published for each unitsubmittals
125 Panominal external static pressure, every sizesubmittals
4installation positions published for each unitsubmittals
FA-H24 to FA-H60-VKCE/AH-454 unitsA-coilFoil-faced insulationECM motor · 1/2 or 3/4 HPR-454B · 208-230 V
The shop

Shop the 4 E-TECH+ electric furnaces

One per tonnage, from FA-H24-VKCE to FA-H60-VKCE.

FORESTAIR
The air handler, tonnage by tonnage

E-TECH+ air handler: dimensions, airflow and electrical by tonnage

Pick the tonnage and what you are checking: the tool shows what the E-TECH+ submittals and brochure publish for that tonnage’s air handler.

FORESTAIR
Tonnage
What you are checking

Dimensions, weight, airflow in CFM, motor, static pressure and fuse: 24K, 36K, 48K and 60K submittals (string 11182025). Airflow in m³/h: E-TECH+ series brochure (document 032026), as printed. The submittals place the 125 Pa static pressure under the indoor unit, the brochure under the outdoor unit.

FA-H36-VKCE/AH-454 · 3-ton · space

500 × 1,180 × 550 mmwidth × height × depth, published

Net · gross weight72.8 kg · 74.8 kg

At the visit, we check that the planned spot can fit the 1,180 mm height and 550 mm depth of the FA-H36-VKCE/AH-454.

Did you know?

E-TECH+ air handler: expansion valves, moisture and refrigerant lines

FORESTAIR
2 electronic expansion valves

one in the indoor unit, one in the outdoor unit, per the 24K to 60K submittals

The 24K to 60K submittals list an electronic expansion valve (EEV) in the indoor-unit data as well as in the outdoor-unit data, for all four sizes.

24K to 60K submittals (string 11182025): indoor and outdoor unit data.
5.29 L/h

the water the 5-ton air handler removes from the air, per its submittal; 3.09 L/h for the 2-ton

Moisture removal: 3.09 L/h for the FA-H24-VKCE/AH-454 and 5.29 L/h for the FA-H60-VKCE/AH-454, per the 24K and 60K submittals; the E-TECH+ series brochure prints the same values.

24K and 60K submittals (string 11182025) and E-TECH+ series brochure (032026): indoor unit.
19.05 mm

the diameter of the refrigerant gas line, the same from the 2-ton to the 5-ton; 9.52 mm for the liquid line, per the submittals

The 24K to 60K submittals and the E-TECH+ series brochure give, for all four sizes, a 19.05 mm (3/4 in) gas line and a 9.52 mm (3/8 in) liquid line, outside diameter.

24K to 60K submittals (string 11182025) and E-TECH+ series brochure (032026): refrigerant piping.
The comparison that matters

3 or 4 tons: the air handler grows to 560 × 1,385 × 610 mm

The submittals give the same dimensions and weight to the 2-ton and 3-ton units, then to the 4-ton and 5-ton units. Between the 3-ton and the 4-ton, the blower motor also goes from 1/2 to 3/4 HP.

FORESTAIR
3 or 4 tons3-ton4-ton
Air handlerFA-H36-VKCE/AH-454FA-H48-VKCE/AH-454
Width × height × depth500 × 1,180 × 550 mm560 × 1,385 × 610 mm
Net · gross weight72.8 kg · 74.8 kg77.6 kg · 84.4 kg
ECM blower motor1/2 HP3/4 HP
Moisture removal3.31 L/h4.67 L/h
Nominal external static pressure125 Pa125 Pa
Fuse for the unit5 A5 A
36K and 48K submittals (string 11182025).

Capacity, efficiency and the indicative LogisVert amount of each combination with its outdoor unit: E-TECH+ central heat pumps

What we check in your home

E-TECH+ air handler: your ducts, the drain, the panel and the run to the outdoor unit

FORESTAIR
  • Your ducts: the submittals give the air handler a nominal external static pressure of 125 Pa (0.5 in w.c.).
  • The drain: a 20 mm (3/4 in) outside-diameter connection, on all four sizes.
  • The electrical panel: a 208-230 V, 60 Hz, single-phase supply for the system.
  • The refrigerant line run to the outdoor unit: 45 m at most, with a height difference of 15 m at most.
Frequently asked questions

E-TECH+ electric furnace: common questions

FORESTAIR
What is in an E-TECH+ “electric furnace”?

Each product page in this collection names two units under one AHRI number, from 217903145 to 217903148: an outdoor unit and an air handler of the same tonnage. The 24K to 60K submittals call the latter an “Air Handler”: a multi-position unit with an A-coil and a five-speed ECM blower. Neither those submittals nor the E-TECH+ series brochure give it a built-in heating element; per the submittals, electric heat can be added to it for extra heat on demand, but neither the brochure nor the submittals publish its model or power.

How much heat does an E-TECH+ “electric furnace” give?

The heat of the heat pump the air handler forms with its outdoor unit. NEEP, the cold-climate heat pump list, lists that heat tonnage by tonnage, from 8.3 °C to −25 °C; those values are on the page of the E-TECH+ central heat pumps. Neither the brochure nor the submittals publish the power of backup electric heat.

Which positions can the E-TECH+ air handler be installed in?

Per the 24K to 60K submittals, it ships in the upflow position and converts on site to horizontal right, horizontal left or downflow. We choose the position with you at the visit.

Which filter and which breaker for the E-TECH+ air handler?

For the air handler alone, nothing: neither the E-TECH+ series brochure nor the 24K to 60K submittals give one. The breaker the submittals publish (MOCP) is for the system, outdoor unit included; it is listed, tonnage by tonnage, on the page of the E-TECH+ central heat pumps. For the air handler itself, they publish none of the following:

  • its MCA and MOP;
  • the filter size;
  • the thermostat type;
  • a table of airflow against static pressure;
  • the model, power in kW, current and minimum airflow of backup electric heat.

MCA: the minimum current the circuit must carry; MOP: the largest breaker or fuse allowed on it. For the air handler, the submittals publish only its 5 A fuse. We check your electrical panel for the chosen combination.

Is the E-TECH+ air handler loud?

The brochure and the submittals publish an indoor-unit sound pressure level of 60 dB(A) at most for the 2-ton, 62 dB(A) for the 3-ton, 63 dB(A) for the 4-ton and 64 dB(A) for the 5-ton. Québec.ca reference points: 40 dB(A) is perceived as peaceful; 50 dB(A) is where noise starts to disturb.

Sold and installed by AirGreen.

Before our visit: 550 or 610 mm of depth to replace your furnace

  • If you are replacing a furnace, measure the width, height and depth of its space: the E-TECH+ air handler measures 500 × 1,180 × 550 mm or 560 × 1,385 × 610 mm.
  • Note its position: upflow, horizontal or downflow; the E-TECH+ air handler converts on site.
RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil: a licensed partner.
Free estimateAt home, no commitment.
LogisVert on the quoteAHRI number and indicative amount when the unit qualifies. Only Hydro-Québec confirms the assistance granted.
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville.

Hydro-Québec never solicits by phone or door to door for the LogisVert Efficient Homes Program.

AirGreenFORESTAIR

Sources

  1. FORESTAIR, E-TECH+ series brochure (French), document 032026 (2026): features and specification table. PDF
  2. FORESTAIR, submittal data FA-H24-VKCE/OD-454 and FA-H24-VKCE/AH-454, “24,000 BTU E-Tech+ Series Central System”, footer string 11182025 (2025). PDF 24K
  3. FORESTAIR, submittal data FA-H36-VKCE/OD-454 and FA-H36-VKCE/AH-454, “34,200 BTU E-Tech+ Series Central System”, footer string 11182025 (2025). PDF 36K
  4. FORESTAIR, submittal data FA-H48-VKCE/OD-454 and FA-H48-VKCE/AH-454, “48,000 BTU E-Tech+ Series Central System”, footer string 11182025 (2025). PDF 48K
  5. FORESTAIR, submittal data FA-H60-VKCE/OD-454 and FA-H60-VKCE/AH-454, “54,000 BTU E-Tech+ Series Central System”, footer string 11182025 (2025). PDF 60K
  6. NEEP, Cold Climate Air Source Heat Pump List, records 508659 to 508662 (AHRI 217903148 to 217903145), read November 5, 2026. ashp.neep.org
  7. Government of Québec, “Noise measurement”, updated June 16, 2022. quebec.ca

Page updated November 11, 2026.