AirGreenFORESTAIR
FORESTAIR · E24 · MZ · E-TECH+FORESTAIR at AirGreenSold and installed by AirGreen. We install in Montréal, Laval, Longueuil, on the South Shore and on the North Shore.
All of FORESTAIR
Updated November 11, 2026
Wall heat pumps · FORESTAIR

FORESTAIR wall heat pumps: four series and how to tell them apart

For LogisVert, one series: the R-454B E24, from 12,000 BTU/h. On a 115 V circuit, the E24 or the E-20, at 9,000 and 12,000 BTU/h; for 36,000 BTU/h, the E-20 only; for the lowest published heating limit, the E-38, at −30 °C. The size is set at the on-site assessment.

21FORESTAIR wall units in four series
−30 °Clowest published heating limit (E-38)E-38 spec sheet
4models on 115 V
6wall units listed on NEEP (E24)records 508680 to 508685
E24 · R-454B · listed on NEEPE-20 · up to 36,000 BTU/h4 series · 2 refrigerants
The four series

FORESTAIR wall heat pumps: the R-454B E24 and the R-410A E-20, E-23 and E-38

Of the four series, only the E24 is on NEEP. That directory of cold-climate heat pumps lists each combination’s heat output at 8.3 °C, −8.3 °C and −15 °C, plus a maximum at −25 °C. The E24 is also the only one in the ENERGY STAR registry, the one LogisVert guide v1.10 requires: a NEEP listing alone does not make a unit eligible for LogisVert.

FORESTAIR
E24R-454B
Models
6
Sizes
9,000 to 24,000 BTU/h
115 V
9,000 and 12,000
Heating limit
−25 °C
NEEP
6 models listed
The R-454B E24 series
E-20R-410A
Models
7
Sizes
9,000 to 36,000 BTU/h
115 V
9,000 and 12,000
Heating limit
−25 °C
NEEP
not listed
The R-410A E-20 series
E-23R-410A
Models
4
Sizes
9,000 to 24,000 BTU/h
115 V
no
Heating limit
−25 °C (sheet), −20 °C (manual)
NEEP
not listed
The R-410A E-23 series
E-38R-410A
Models
4
Sizes
9,000 to 24,000 BTU/h
115 V
no
Heating limit
−30 °C
NEEP
not listed
The R-410A E-38 series

Beyond one wall unit: the other FORESTAIR heat pumps

More than one room?
Outdoor units
FA-M18 to FA-M42
Multi-zone heat pump: 2 to 5 heads on one outdoor unit
On the ceiling?
Sizes
9,000 to 24,000 BTU/h
Ceiling cassette: the same outdoor unit as the E24
A home with ducts?
Product codes
FA-H24-VKCE to FA-H60-VKCE
E-TECH+ central heat pump, 2 to 5 tons
Series sorter

Sort FORESTAIR wall units by size, 115 V circuit and LogisVert

Pick a size, a circuit and a priority: the sorter keeps one wall unit per series and ranks them. The size itself is confirmed at the on-site assessment.

FORESTAIR
Size
Circuit
Priority
  • FORESTAIR E-38 · 12,000 BTU/h R-410AHeating published down to −30 °C · indoor at its lowest: 22 dB(A) · Not listed on NEEP · LogisVert: not in the ENERGY STAR registry
  • FORESTAIR E24 · 12,000 BTU/h R-454BHeating published down to −25 °C · indoor at its lowest: 30 dB(A) · NEEP at −15 °C: 9,100 BTU/h · LogisVert: $1,200, indicative amount
  • FORESTAIR E-20 · 12,000 BTU/h R-410AHeating published down to −25 °C · indoor at its lowest: 34 dB(A) · Not listed on NEEP · LogisVert: not in the ENERGY STAR registry
  • FORESTAIR E-23 · 12,000 BTU/h R-410AHeating published down to −25 °C (sheet) or −20 °C (manual) · indoor at its lowest: 29 dB(A) · Not listed on NEEP · LogisVert: not in the ENERGY STAR registry

First: FORESTAIR E-38 · 12,000 BTU/h

−30 °Cpublished heating limit

Criterionthe lowest published heating limit
Size and circuit12,000 BTU/h · other than 115 V
Series at this size4

Heating limits and sound levels: each series’ spec sheet and the E24 brochure. The E-23 has two limits, −25 °C on its sheet and −20 °C in its owner’s manual: the sorter ranks it at −20 °C. At an equal limit, a unit listed on NEEP comes first, then the order E24, E-20, E-23, E-38. Sound level: the lowest indoor value in each document (in cooling for the E-20); at an equal sound level, same order, for example the E24, E-20 and E-38 at 34 dB(A) at 18,000 BTU/h. Heat at −15 °C: NEEP, read November 5, 2026. The E-20, E-23 and E-38 give SEER and HSPF, the E24 SEER2 and HSPF2: the sorter does not compare them. Québec.ca benchmarks: 40 dB(A) is perceived as peaceful; 50 dB(A) is where noise starts to disturb. Indicative amount. Only Hydro-Québec confirms the assistance granted.

The shop

The 21 FORESTAIR wall heat pumps in our catalogue

By series: 6 E24, 7 E-20, 4 E-23 and 4 E-38.

FORESTAIR
Did you know?

FORESTAIR wall units: three differences between the series

FORESTAIR
24,000 · 23,000 · 22,000

the published cooling capacity of the “24,000” size, by series

Nominal cooling capacity of the 24,000 size: 24,000 BTU/h in the E-20, 23,000 BTU/h in the E24, 22,000 BTU/h in the E-23 and E-38. The E24 brochure prints 24,000 in its banner and 23,000 in its table.

E-20, E-23 and E-38 spec sheets (forestair.ca); E24 series brochure, document 072025.
15 · 20 · 25 m

the maximum line length between the indoor and outdoor units, by series and size

Per the spec sheets and the brochure: E-20, 15 m at every size; E24, 15 m for the 9,000 and 12,000 and 20 m for the 18,000 and 24,000; E-23 and E-38, 15 m at 9,000, 20 m at 12,000 and 25 m at 18,000 and 24,000. We measure the actual distance between the two units at the visit.

E-20, E-23 and E-38 spec sheets (forestair.ca); E24 series brochure, document 072025: refrigeration system.
195 · 289 · 300 mm

the height of the 12,000 BTU/h indoor unit: E24, E-23, E-38

Indoor-unit height at 12,000 BTU/h: 195 mm for the E24 (E24 brochure), 289 mm for the E-23 and 300 mm for the E-38 (E-23 and E-38 spec sheets). The E-20 sheet gives its dimensions in inches only. Above a window or a door, the free height is what counts: we measure it at the visit.

E24 series brochure, document 072025: indoor unit; E-23 and E-38 spec sheets (forestair.ca).
The comparison that matters

Wall unit or ceiling cassette: the same outdoor unit, two results

The 12,000 BTU/h E24 wall unit and the 12,000 BTU/h FORESTAIR cassette share the FA-H12-D24TL-O-454 outdoor unit. NEEP lists the two combinations separately, the cassette under its SZ24-ES454 series.

FORESTAIR
12,000 BTU/h, 208-230 VE24 wall unitFORESTAIR cassette
Indoor unitFA-H12-D24TL-I-454FA-K12-D24TL-I-454
AHRI217512358217549974
Heating capacity at −8.3 °C10,000 BTU/h10,500 BTU/h
Heating capacity at −15 °C9,100 BTU/h9,000 BTU/h
Maximum at −25 °C6,680 BTU/h6,680 BTU/h
SEER22421
HSPF2 (Region IV)1010
LogisVert, indicative amount$1,200$1,260
NEEP records 508682 and 508671; ENERGY STAR registry (Canadian market), records 4529620 and 4529632. Indicative amount. Only Hydro-Québec confirms the assistance granted. See the FORESTAIR ceiling cassettes
Who does what

AirGreen × FORESTAIR: who does what for your wall heat pump

FORESTAIR
FORESTAIR

From FORESTAIR

  • The E-20, E-23 and E-38 spec sheets, and the E24 series brochure
  • The six E24 units’ listing on NEEP and in the ENERGY STAR registry
AirGreen

From AirGreen

  • The choice between E24, E-20, E-23 and E-38 by room, circuit and LogisVert
  • The on-site assessment, before settling on one of the four series
  • The quote with the AHRI number and, when the unit qualifies, the indicative LogisVert amount; only Hydro-Québec confirms the assistance granted
  • The installation, under RBQ licence 5645-9605-01
Frequently asked questions

FORESTAIR wall heat pumps: common questions

FORESTAIR
Which FORESTAIR wall heat pumps qualify for LogisVert?

The E24 units of 12,000 BTU/h and up, with an indicative amount. The LogisVert participant’s guide (version 1.10, September 15, 2026) calls for an ENERGY STAR certified heat pump, and only the six E24 units are in the registry (Canadian market, records 4529617 to 4529622); the 9,000 units are under its 12,000 BTU/h nominal minimum. No E-20, E-23 or E-38 model is in the registry as read on November 5, 2026, even though the E-23 and E-38 sheets print “Energy Star: Oui” (yes). Only Hydro-Québec confirms the assistance granted.

Which FORESTAIR wall heat pump runs on 115 V?

Four models: the E24 and the E-20, at 9,000 and 12,000 BTU/h. No other model in these four series is published on 115 V. We check your electrical panel at the visit.

R-454B or R-410A: what is the difference?

The ENERGY STAR registry lists a global warming potential (GWP) of 470 for the E24’s R-454B (465 in the US EPA reference table); the same EPA table gives 2,088 for R-410A, the refrigerant of the E-20, E-23 and E-38. Of the four series, only the E24 is in the ENERGY STAR registry as read on November 5, 2026, so it alone carries an indicative LogisVert amount.

SEER or SEER2: why do FORESTAIR wall units not show the same metric?

Because their documents do not publish the same metric: the E-20, E-23 and E-38 sheets give SEER, HSPF and EER; the E24 brochure gives SEER2, HSPF2 and EER2. SEER (or SEER2) is the seasonal efficiency in cooling, HSPF (or HSPF2) in heating: a higher figure means less electricity for the same job. So we do not put a SEER next to a SEER2.

Wall heat pump for deep cold: the E-38 or the E24?

The E-38 sheet publishes the lowest limit: −30 °C, against −25 °C for the E24. But the E-38 is not listed on NEEP, and its sheet gives no heating capacity at a given temperature: we know how far down it runs, not how much heat it gives. For the E24, NEEP lists that heat at −8.3 °C and −15 °C, and a maximum at −25 °C.

Sold and installed by AirGreen.

Before our visit: two checks that decide the series

  • A photo of your electrical panel: it tells us whether 115 V is possible.
  • The number of rooms: one room, one wall unit; two to five, the multi-zone FA-M18 to FA-M42.
RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil: a licensed partner.
Free estimateAt home, no commitment.
LogisVert on the quoteAHRI number and indicative amount when the unit qualifies. Only Hydro-Québec confirms the assistance granted.
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville.

Hydro-Québec never solicits by phone or door to door for the LogisVert Efficient Homes Program.

AirGreenFORESTAIR

Sources

  1. FORESTAIR, E24 series brochure, document 072025 (2025). PDF
  2. FORESTAIR, E-20, E-23 and E-38 series spec sheets, read November 5, 2026. forestair.ca
  3. FORESTAIR, E23 series owner’s manual. E23 manual (PDF)
  4. NEEP, Cold Climate Air Source Heat Pump List, records 508671 and 508680 to 508685, read November 5, 2026. ashp.neep.org
  5. ENERGY STAR, heat pump registry, Canadian market (dataset w7cv-9xjt), including the R-454B GWP, read November 5, 2026. data.energystar.gov
  6. US EPA, Technology Transitions GWP Reference Table (R-454B, R-410A), updated April 2, 2026, checked November 5, 2026. epa.gov
  7. Hydro-Québec, LogisVert Efficient Homes Program, participant’s guide, version 1.10 (September 15, 2026). Indicative amounts: those on our product pages. hydroquebec.com
  8. Government of Québec, “Noise measurement”, updated June 16, 2022. quebec.ca

Page updated November 11, 2026.