AirGreenFORESTAIR
FORESTAIR · E24 · MZ · E-TECH+FORESTAIR at AirGreenSold and installed by AirGreen. We install in Montréal, Laval, Longueuil, on the South Shore and on the North Shore.
All of FORESTAIR
Updated November 11, 2026
E-23 series · R-410A

FORESTAIR E-23 wall heat pump: how far each size slows down and speeds up

Per its sheet, the 12,000 BTU/h E-23 runs from 2,400 to 14,000 BTU/h in heating: it can slow down to 18% of its nominal capacity instead of running flat out. The 9,000 goes lowest, 1,911 BTU/h; the 24,000 highest, 30,708 BTU/h; no output is published for deep cold.

4R-410A E-23 models, all on 208-230 V
1,911BTU/h: the lowest heating output (9,000)
30,708BTU/h: the highest heating output (24,000)E-23 spec sheet
−25 / −20 °Cheating limit: per the sheet / per the manualspec sheet and E23 manual
4 models · R-410ACooling: 3,100 to 27,296 BTU/h by sizeSEER 20 to 23 by size
The shop

The 4 E-23 wall heat pumps in our catalogue

FORESTAIR
E-23 modulation range

E-23 output range in heating and cooling, size by size

For each size, the E-23 spec sheet gives a nominal capacity and a range, in heating and in cooling. The bars put the three values side by side.

FORESTAIR
Size
Mode

Ranges, nominal capacities and power input: E-23 spec sheet table (forestair.ca, read November 5, 2026). Bars scaled to the maximum of the chosen size and mode; the shares are relative to the nominal capacity.

E-23 · 12,000 size · heating

2,400 to 14,000BTU/h in heating, lowest to highest

Nominal capacity13,000 BTU/h
At its lowest, share of nominal18%
At its highest, share of nominal108%
Electrical power input400 to 1,400 W (nominal 1,100 W)
Lowest2,400
Nominal13,000
Highest14,000

Shares: our arithmetic on the sheet’s figures. These ranges do not show the heat left in deep cold: NEEP, the cold-climate heat pump list, has no E-23.

Did you know?

E-23: three details from the spec sheet

FORESTAIR
Heated base

under the E-23 outdoor unit, so the condensate does not freeze

The E-23 sheet says the outdoor unit has a heated base that keeps the condensate from freezing, so heating runs at full efficiency.

E-23 spec sheet (forestair.ca), features.
6,824 BTU/h

the lowest heating output of the 24,000 E-23, below the 18,000’s (7,340)

Heating ranges on the sheet: 7,340 to 23,500 BTU/h for the 18,000, 6,824 to 30,708 BTU/h for the 24,000. So the larger unit slows down further than its neighbour. In cooling, they start from almost the same point: 6,800 and 6,824 BTU/h.

E-23 spec sheet (forestair.ca), model table.
11,000 BTU/h

the nominal heat of the 9,000 E-23, above its nominal cooling of 9,000 BTU/h

Nominal capacities on the E-23 sheet, heating against cooling: 11,000 against 9,000 BTU/h for the 9,000, 13,000 against 12,000 for the 12,000, 19,800 against 18,000 for the 18,000, 23,000 against 22,000 for the 24,000. These are nominal values: they say nothing about heat in deep cold.

E-23 spec sheet (forestair.ca), model table.
The comparison that matters

18,000 BTU/h wall heat pump: E-23 or E-38

Two R-410A FORESTAIR wall units of the same size: the E-23 sheet lists more nominal heat, the E-38 sheet a wider range and a lower limit.

FORESTAIR
18,000 BTU/hE-23E-38
Nominal heating19,800 BTU/h18,000 BTU/h
Heating range7,340 to 23,500 BTU/h4,094 to 24,566 BTU/h
Cooling range6,800 to 20,000 BTU/h4,094 to 21,837 BTU/h
SEER20.024.5
HSPF (region not stated)10.012.0
Lowest indoor sound level39 dB(A)34 dB(A)
Published heating limit−25 °C per the sheet, −20 °C per the manual−30 °C (sheet and manual)
Minimum circuit ampacity / maximum protection16 / 25 A22 / 30 A
Outdoor unit: dimensions, net weight965 × 700 × 396 mm, 48 kg980 × 790 × 427 mm, 64 kg
E-23 and E-38 spec sheets; E23 and E38 owner’s manuals. SEER and HSPF: the E-23’s and E-38’s efficiency over a cooling season and over a heating season; the higher the number, the less the unit uses (SEER 20.0 against 24.5 at 18,000). Neither sheet names the HSPF climate region. Neither the E-23 nor the E-38 is on NEEP or in the ENERGY STAR registry (Canadian market). Québec.ca reference points: 40 dB(A) is perceived as peaceful; 50 dB(A) is where noise starts to disturb. Only Hydro-Québec confirms the assistance granted. See the E-38 series Compare the four wall series See the E24 series (indicative LogisVert amount from 12,000 BTU/h)
What we check in your home

208-230 V circuit and outdoor unit: what we measure for an E-23

FORESTAIR
  • The 208-230 V circuit: an MCA (the minimum current the circuit must carry) of 9 to 20 A, and an MOP (the largest breaker or fuse allowed on it) of 15 to 30 A depending on the size.
  • The outdoor unit: 848 × 540 × 320 mm and 35.5 kg for the 9,000, up to 980 × 790 × 427 mm and 64.5 kg for the 24,000.
Frequently asked questions

E-23 wall heat pump: common questions

FORESTAIR
Does the E-23 heat down to −25 °C?

Its two documents disagree: −25 °C per its spec sheet (table and banner), −20 °C per its owner’s manual, which gives the heat pump an outdoor range of −20 °C to 46.1 °C. Neither is dated. When we compare the series, we use the more cautious one, −20 °C. No output is published at these temperatures.

Does the E-23 qualify for LogisVert?

No. Its sheet prints “Energy Star: Oui” (yes) for all four sizes, but no E-23 is in the ENERGY STAR registry (Canadian market), and the LogisVert participant’s guide v1.10 (September 15, 2026) calls for an ENERGY STAR certified heat pump. The R-454B E24 is the only FORESTAIR wall series with an indicative LogisVert amount, from 12,000 BTU/h. Only Hydro-Québec confirms the assistance granted.

Why does the 24,000 E-23 have no AHRI number?

The E-23 sheet leaves the cell blank for that size; it gives 206720373 for the 9,000, 206720374 for the 12,000 and 206720375 for the 18,000. So the quote for a 24,000 E-23 cannot carry an AHRI number published by the brand.

Is the E-23 heat pump quiet?

The sheet gives four indoor levels per size. The 9,000 and 12,000 go down to 29 dB(A), from 43 and 45 dB(A) at the highest; the 18,000 goes down to 39 dB(A) (47 at the highest), the 24,000 to 36 dB(A) (48 at the highest). Outdoors: 53, 54, 55 and 59 dB(A). Québec.ca reference points: 40 dB(A) is perceived as peaceful; 50 dB(A) is where noise starts to disturb.

Which circuit does an E-23 need?

The sheet gives 208-230 V for all four sizes. The 9,000 and 12,000 call for an MCA of 9 A and an MOP of 15 A. The 18,000 calls for 16 and 25 A, the 24,000 for 20 and 30 A. We check your panel at the on-site assessment for the chosen E-23 size.

Does the E-23 have Wi-Fi?

Its sheet lists the included remote and an optional wired wall thermostat. The E23 manual describes turning on Wi-Fi (MODE and TURBO keys) and notes that it applies only to some models: we check this for the chosen E-23 before the quote.

Sold and installed by AirGreen.

From the room to the outdoor unit: 15 to 25 m at most for your E-23

  • The maximum distance between the two units: 15 m at 9,000, 20 m at 12,000, 25 m at 18,000 and 24,000, with 10 m of height difference at most, per the sheet.
  • The free width on the room’s wall: the indoor unit is 845 mm (9,000 and 12,000) to 1,078 mm (24,000) wide.
RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil: a licensed partner.
Free estimateAt home, no commitment.
E-23 model on the quoteThe chosen model and, from the 9,000 to the 18,000, the AHRI number on the sheet.
Showroom1370 Joliot-Curie Street, Suite 712, Boucherville.

Hydro-Québec never solicits by phone or door to door for the LogisVert Efficient Homes Program.

AirGreenFORESTAIR

Sources

  1. FORESTAIR, “Série E-23” page on forestair.ca (French) and its spec images (banner, features, model table), read November 5, 2026. forestair.ca (French series page)
  2. FORESTAIR, E23 series owner’s manual, French version (no date printed). E23 manual FR (PDF)
  3. FORESTAIR, E23 series owner’s manual, English version (no date printed). E23 manual EN (PDF)
  4. FORESTAIR, “Série E-38” page on forestair.ca (French) and its model table, read November 5, 2026. forestair.ca (French series page)
  5. FORESTAIR, E38 series owner’s manual, English version: operating range (no date printed). E38 manual EN (PDF)
  6. ENERGY STAR, heat pump registry, Canadian market (dataset w7cv-9xjt), read November 5, 2026: no E-23 or E-38. data.energystar.gov
  7. NEEP, Cold Climate Air Source Heat Pump List, read November 5, 2026: no E-23 or E-38 listed. ashp.neep.org
  8. Hydro-Québec, LogisVert Efficient Homes Program, participant’s guide, version 1.10 (September 15, 2026): the heat pump must be ENERGY STAR certified. EN guide (PDF)
  9. Government of Québec, “Noise measurement”, updated June 16, 2022. quebec.ca