tekmar · Hydronic controlsThe tekmar space at AirGreentekmarNet thermostats, Zone Managers, gateways and tekmar Wi-Fi thermostats, sold by AirGreen in Montréal, Laval, Longueuil, the South Shore and the North Shore.
Mon to Thu 8 a.m. to 6 p.m. · Fri 8 a.m. to 4 p.m.
TEKMAR · Hydronic controls · updated October 14, 2026
Hot-water heating, controlled zone by zone
tekmar designs and assembles its controls in Canada; its head office is in Vernon, B.C. The lineup forms three families that do not communicate with each other: the wired tekmarNet network, the Wi-Fi thermostats run from the Watts Home app, and stand-alone controls for radiant floors and mixing. Pick the family first; the rest follows.
Each thermostat joins your Wi-Fi on its own. No gateway, no Zone Manager: tekmar does not list them with the tekmarNet network. 2.4 GHz Wi-Fi for the 561, 563 and 564.
519thermostat079slab361mixing5181 sensor
No network. A floor thermostat with its slab sensor, or a mixing control that sets the water temperature from the outdoor temperature.
6valve zones per Zone Manager 335
24budget units per tN4 bus
4zone-pump zones per Zone Manager 336
1ENERGY STAR model: the 564 Invita
AirGreen × tekmarDesigned and assembled in CanadaOne thermostat per zone335: 6 valve zones · 336: 4 pump zonestN4 bus: 24 budget units564 Invita: ENERGY STARMontréal · Laval · Longueuil · South Shore · North Shore
AirGreen × tekmarDesigned and assembled in CanadaOne thermostat per zone335: 6 valve zones · 336: 4 pump zonestN4 bus: 24 budget units564 Invita: ENERGY STARMontréal · Laval · Longueuil · South Shore · North Shore
01 · The lineup
Three families, one question: how your zones talk to each other
Every model in our store, sorted by family. The filter shows what goes together.
All five run on tN2 (2 wires), tN4 (4 wires) or alone on 3 wires. Network features (schedules, warm weather shutdown) need a tekmarNet system control, such as a Zone Manager.
04 · Gateways
486 or 482: two gateways, two worlds
The 486 opens the app; the 482 talks to home automation. They do not do the same thing.
For the app: the 486 gateway, wired to every tN4 bus in the house.
The 361 is not a thermostat or a valve: it sets the mixed-water temperature from the outdoor temperature by varying the speed of an injection pump.
Ships with a 070 outdoor sensor and two 082 universal sensors (mixed water, boiler).
Protects the boiler against cold return water (BOIL MIN setting, with the boiler sensor).
Contacts for the system pump and the boiler; optional 076/077 indoor sensor.
Applications: high- or low-mass floor, fan coil, convector, radiator, baseboard.
The 361 does not communicate on the tekmarNet network. Source: Data Brochure D 361, 03/09. See the 361 product page
AirGreen × tekmar
tekmar’s controls, a local quotation.
tekmar designs the controls and publishes the rules that tie them together. AirGreen helps you build the set that follows them, on quotation. Each does what it does best.
tekmar
What tekmar brings
Designed and assembled in CanadaHead office in Vernon, B.C.; tekmar is a Watts company.
The tekmarNet networkThermostats, 335 and 336 Zone Managers and gateways on one tN4 bus.
The Wi-Fi thermostats561 to 564 on the Watts Home app; the 564 Invita is ENERGY STAR.
Limited manufacturer warrantyPer tekmar’s warranty document; labour not covered by the manufacturer.
What AirGreen brings
Sold by AirGreenThe tekmar models in our store, in Montréal, Laval, Longueuil, the South Shore and the North Shore.
tekmar’s rules, appliedThe set builder follows tekmar’s dated documents and says “on quotation” where they are silent.
Hydronic workDone by a licensed partner.
RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: a tekmar set that follows the manufacturer’s rules, price on quotation.
Only one grant targets a tekmar model, and it is for gas
Checked on October 14, 2026 on each program’s own site. No stacking is presented here.
Eligible
Énergir: $100 for the 564 Invita
Énergir’s PE-104 list (valid as of October 1, 2026) names the 564 at $100. For Énergir customers with central natural-gas heating, one thermostat per system, apply within 30 days of purchase. No other tekmar model is listed.
Certified
ENERGY STAR: the 564 only
In the ENERGY STAR connected-thermostat database, tekmar has a single model: the 564 Invita, qualified on July 11, 2025 for Canada and the United States.
Not eligible
Hydro-Québec: LogisVert and Hilo
LogisVert covers heat pumps, electric thermal storage, efficient pool pumps and solar pool heating, induction ranges, heat-pump dryers and roof insulation, not thermostats. Hilo supports Honeywell Home, Mysa and Sinopé, not tekmar.
Markings
CSA C US on five models
Zone Managers 335 and 336, the 482 gateway, the 361 mixing control and the 079 sensor carry the CSA C US mark. Thermostats, 335, 336, 486 and 361: ICES and FCC Class B.
09 · tekmar warranty
A manufacturer warranty, and what it does not cover
What tekmar’s “Limited Warranty” document says, linked from every product page on watts.com.
DefectsCovers defects in materials and workmanship, when the product is installed and used per tekmar’s instructions.
RemedyRepair, exchange or credit, at tekmar’s choice, through the tekmar representative.
LabourNot covered: labour to remove, ship or reinstall.
Length and conditions are those of the tekmar warranty document.
AirGreen × tekmarDesigned and assembled in CanadaOne thermostat per zone335: 6 valve zones · 336: 4 pump zonestN4 bus: 24 budget units564 Invita: ENERGY STARMontréal · Laval · Longueuil · South Shore · North Shore
AirGreen × tekmarDesigned and assembled in CanadaOne thermostat per zone335: 6 valve zones · 336: 4 pump zonestN4 bus: 24 budget units564 Invita: ENERGY STARMontréal · Laval · Longueuil · South Shore · North Shore
10 · Frequently asked questions
The questions we get about tekmar
Does AirGreen do the hydronic work?
Hydronic work (boiler, piping, pumps, valves) is done by a licensed partner. AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8, 15.10 and 16.
What is the difference between tekmarNet and the Wi-Fi thermostats?
tekmarNet is a wired network (tN2 or tN4 bus) between thermostats, Zone Managers and gateways. The 561 to 564 join your Wi-Fi on their own with the Watts Home app. tekmar does not link the two.
Does the 482 let me reach my heating from my phone?
No. The 482 is an RS-232 interface for home automation (Control4, Crestron…). For the tekmarNet app, it is the 486 gateway.
How many thermostats on one tN4 bus?
The budget total must not exceed 24: the 532, 552 and 554 count 1.0; the 553 and 557 count 1.1 (1.6 and 1.7 with a 482 gateway). Source: tekmar Service Bulletin 083.
335 or 336?
The 335 runs up to 6 zones on 24 V zone valves. The 336 runs up to 4 zones on 115 V zone pumps. Both have a group-pump output.
Can I wire a 563 Wi-Fi thermostat to a Zone Manager?
tekmar does not document it: the 561 to 564 appear in no 335, 336, 482 or 486 compatibility list. So we do not offer it.
Does the 519 come with its floor sensor?
Yes, the 519 Radiant Thermostat ships with the 079 slab sensor.
Which app do I use?
The tekmarNet app for a tekmarNet network with a 486 gateway. The Watts Home app for the 561 to 564 Wi-Fi thermostats.
Do tekmar Wi-Fi thermostats work on 5 GHz?
No: the 561, 563 and 564 manuals state 2.4 GHz Wi-Fi only.
Are tekmar thermostats eligible for LogisVert?
No. Hydro-Québec’s LogisVert does not cover thermostats or hydronic controls.
Does the 361 work with a mixing valve?
tekmar does not provide for it: the 361 sets the mixed water by varying the speed of an injection pump, based on the outdoor temperature.
What warranty does tekmar offer?
A limited manufacturer warranty against defects. Labour, removal and transport are not covered. Length and conditions are those of the tekmar document in force.
Where are tekmar products made?
tekmar states they are designed and assembled in Canada. The head office is in Vernon, British Columbia; tekmar has been part of Watts since 2012.
How much does a tekmar set cost?
Price on quotation. Send us your list of zones through our Contact page.
No question matches. Write to us through the Contact page.
AirGreen · Your tekmar controls supplier
Your list of zones, our quotation
Send the number of zones, the distribution type and what each zone must do. Hydronic work is done by a licensed partner.