AirGreenARCOAIRE
AirGreen × ARCOAIRE · Add-on to a furnaceYour furnace stays, the heat pump is addedSold and installed by AirGreen across Montreal, Laval, Longueuil, the South Shore and the North Shore.
The full ARCOAIRE range
  1. Home
  2. ARCOAIRE
  3. Add-on to a furnace
ARCOAIRE add-on central heat pump · Updated October 29, 2026

Keep your furnace. A coil goes on top, and the heat pump heats and cools.

Six DLCURA + DLFULA coil pairings are ENERGY STAR cold-climate certified. Pick the coil width and the size: you see the certified pairing, its heat as listed by NEEP and its indicative LogisVert amount.

41ARCOAIRE add-on products on our site
6ENERGY STAR cold-climate certified pairings, all DLCURA + DLFULA
-30 °Cheating limit printed for the high-heat DLCURA
14.5 · 17.5 · 21 inDLFULA coil widths on our sheets
01 · Your furnace

Which coil width, which certified pairing?

The coil sits on the furnace’s air outlet (on top, or underneath if it blows downward): its width follows the cabinet. The figures come from NEEP and ENERGY STAR data (Canadian market), for the exact pairing.

DLFULA coil width (our sheets)

Heat pump size

The 6 certified pairings: rated heat at -8 °C

1.5 tonscoil 17.5 in
14,700 BTU/h
2 tonscoil 14.5 in
22,400 BTU/h
2 tonscoil 17.5 in
21,000 BTU/h
2.5 tonscoil 21 in
22,600 BTU/h
3 tonscoil 17.5 in
27,400 BTU/h
3 tonscoil 21 in
33,000 BTU/h

Measure the furnace cabinet width, left to right. The coil width comes from our product sheets: we have no manufacturer document that prints it for the DLFULA. Everything is confirmed at the visit.

3 tons · coil 21 in
24,000BTU/h max. at -30 °C

Certified pairing DLCURAH36ABK + DLFULAH36XCX.

Rated heat at -8 °C33,000 BTU/h
Maximum at -15 °C32,000 BTU/h
SEER2 · HSPF215.2 · 10
AHRI · ENERGY STAR213372121 · 2841442
Indicative LogisVert$3,960
See the product →

Values as listed by NEEP (record 399251); ENERGY STAR cold-climate certified in Canada. LogisVert amount from our product sheet: only Hydro-Québec confirms the amount granted.

NEEP’s coldest listed point is -22 °F (-30 °C) for five pairings and -13 °F (-25 °C) for the 2-ton with the 14.5 in coil: the tool shows the maximum at that point. The manufacturer prints a heating range of -22 to 86 °F (-30 to 30 °C) for the high-heat DLCURA.

The shop

All 41 ARCOAIRE add-on products, right below.

Each product names the outdoor unit and the coil. The indicative LogisVert amount appears only on the six certified pairings; an AHRI number appears on those six and on two H4H7T products. Pricing by quote.

ARCOAIRE
02 · Who does what

The furnace stays in place. We add the heat pump on top.

The heat pump is AirGreen’s job. Gas and oil belong to a licensed partner.

AirGreen

  • The outdoor unit, on its base, above the snow.
  • The coil, set on top of the furnace, and the refrigerant lines out to the outdoor unit.
  • The electrical supply to the outdoor unit and the thermostat.
  • Commissioning the heat pump, heating and cooling.

A licensed partner

  • Any work on a gas or oil furnace: burner, combustion, gas or oil connections.
  • Checking the fuel side of the furnace, when the project calls for it.

AirGreen holds RBQ licence 5645-9605-01, subclasses 15.8, 15.10 and 16.

03 · The visit

What we check at your home, before the quote.

Four points, taken from the manufacturer’s documents.

1

The furnace

We measure the cabinet and the space above it. For its EVD4X coils, the manufacturer prints the furnace width they fit flush on: 14-3/16, 17-1/2, 21 or 24-1/2 in. Turned 90°, the coil needs a transition of at least 4 in.

EVD-ESD4X-31-02PD, ed. 06/22, p. 3

2

The pairing and its AHRI rating

The manufacturer points to the AHRI directory for the DLCURA’s current ratings. The six DLCURA + DLFULA pairings have their AHRI number; for the other products, we confirm the coil and the rating before the quote.

DLCURA31-01PD, ed. 09/22, p. 1

3

The line set

The DLCURA takes up to 213 ft (65 m) of line set, the R4H5S up to 250 ft (76.20 m) equivalent length. The manufacturer advises against burying the lines; if it must be done, no more than 36 in (914 mm) of line underground, with a vertical rise of at least 6 in (152 mm) to the service valves.

DLCURA31-01PD, pp. 1 and 82; R4H5S-01PD, pp. 1 and 18

4

The heat pump–furnace handoff

The manufacturer describes the idea in its Crossover brochure: paired with an oil or gas furnace, the heat pump switches automatically between the two sources based on the outdoor temperature. We look at your thermostat and the furnace controls.

DLS-045-AR-00, 4/2025, p. 2

04 · The other 35

35 products with an EVD4X coil: no certified data shown.

These products pair a conventional central heat pump with an EVD4X coil. The manufacturer designs that coil for cooling (“AC applications only”). For a heat pump, we confirm at the visit a coil approved for heating and the pairing’s AHRI rating, before the quote.

FamilyProductsSizesAHRI rating of the pairingDocument
Conventional heat pump + EVD4X coil · R-410A
R4H5S
Single stage, scroll compressor. The manufacturer ranks it “Entry”.
71.5 · 2 · 2.5 · 3 · 3.5 · 4 · 5 tonsnone on our sheetsR4H5S-01PD, 09/22, p. 1-2
N4H5S
Performance Series, single stage.
71.5 · 2 · 2.5 · 3 · 3.5 · 4 · 5 tonsnone on our sheetsHP-003-AR-00, 12/2022, p. 4
H4H5S
Ion™ System, single stage.
71.5 · 2 · 2.5 · 3 · 3.5 · 4 · 5 tonsnone on our sheetsHP-002-AR-00, 01/2023, p. 4
H4H7T
Ion™ System, two stages.
42 · 3 · 4 · 5 tons2 numbers on our sheets, not listed by NEEP or ENERGY STARHP-002-AR-00, 01/2023, p. 3-4
HCH6
Two stages. Ratings published in SEER and HSPF, before SEER2.
12 tonsnone on our sheets42832540504, 09/2017, p. 3-4
HSH6
Single stage. Ratings published in SEER and HSPF, before SEER2.
61.5 · 2 · 2.5 · 3.5 · 4 · 5 tonsnone on our sheets42832540504, 09/2017, p. 3-4
HSH4
Single stage. Ratings published in SEER and HSPF, before SEER2.
33.5 · 4 · 5 tonsnone on our sheets42832540504, 09/2017, p. 3-4

Coil: EVD-ESD4X-31-02PD, ed. 06/22, p. 1. We found none of these pairings in the ENERGY STAR data (search by model, November 5, 2026). The 2 AHRI numbers on our sheets are not listed by NEEP; the other 33 products have no AHRI number to look up there. The families are described in detail on the central heat pump page.

The families in detail: central heat pumps →

Did you know

Three things the data tells you.

-25 °C

Same 2-ton DLCURA, two coils, two NEEP cold points.

With the 14.5 in coil, the NEEP record stops at -25 °C (16,500 BTU/h maximum); with the 17.5 in coil, it goes down to -30 °C, like the other four pairings. That is the coldest point listed, not an operating limit.

NEEP, records 399255 and 399254, August 24, 2026
-23.3 °C

Below -23.3 °C, the R4H5S is outside its heating range.

The manufacturer sets -23.3 °C (-10 °F) as the R4H5S’s minimum outdoor operating temperature in heating. Colder than that, your furnace does the heating.

R4H5S-01PD, ed. 09/22, p. 18
No baffles

Down to -30 °C without wind baffles.

The manufacturer says it for the high-heat DLCURA: it runs in deep cold, down to -22 °F (-30 °C), with no wind baffles around the outdoor unit.

DLCURA31-01PD, ed. 09/22, p. 1
05 · Questions

What people ask us about add-on systems.

I keep my gas or oil furnace: who does what?

AirGreen installs the outdoor unit, the coil on the furnace, the refrigerant lines, the electrical work and the thermostat. Any work on the gas or oil side is done by a licensed partner.

How do I know if my furnace is suitable, and which size to get?

At the visit. We measure the furnace and the space above it, look at the ducts and the electrical panel, then check the pairing and its AHRI rating.

My electric furnace is at the end of its life: add-on or replacement?

If it has to be replaced, the indoor unit changes too: see the ARCOAIRE fan coils (electric furnace page) and the complete systems (central heat pump page). If it is in good shape, we check at the visit whether a coil can sit on it.

Why does the coil width change the figures?

Each outdoor unit + coil pairing has its own AHRI number and ratings. At 3 tons, for example, the DLCURA is listed at 33,000 BTU/h at -8 °C with the 21 in coil and 27,400 BTU/h with the 17.5 in coil.

What about LogisVert?

Our product sheets give an indicative amount for the six certified pairings, none for the other 35. Only Hydro-Québec confirms the amount granted.

What about the products with an EVD4X coil?

We show no certified data for them: we found none of these pairings at ENERGY STAR (search by model, November 5, 2026), and 33 of these products have no AHRI number to look up in NEEP. The manufacturer designs the EVD4X coil for cooling (“AC applications only”). For a heat pump, we confirm at the visit a coil approved for heating and the pairing’s AHRI rating, before the quote.

AirGreen × ARCOAIRE

Your furnace stays. The heat pump does the rest.

We measure the furnace, check the pairing and its AHRI rating, then give you a quote with the system and its AHRI number when it has one. Gas and oil stay with a licensed partner.

RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.
Free on-site estimateSize and pairing are decided at your home, once we have seen the furnace, the ductwork and the electrical panel.
Sold and installed by AirGreenMontreal, Laval, Longueuil, South Shore and North Shore.

Sources checked on October 29, 2026

  1. ARCOAIRE, product data DLCURA31-01PD (ed. 09/22), pp. 1, 2 and 82: high-heat version, no wind baffles, line set, AHRI directory, heating range.
  2. ARCOAIRE, brochure DLS-045-AR-00 (4/2025), p. 2: dual fuel.
  3. ARCOAIRE, product data EVD-ESD4X-31-02PD (ed. 06/22), pp. 1 and 3: “AC applications only”, furnace width.
  4. ARCOAIRE, product data R4H5S-01PD (ed. 09/22), pp. 1, 2 and 18: ranking, line sets, operating limits.
  5. ARCOAIRE, brochures HP-002-AR-00 (01/2023) and HP-003-AR-00 (12/2022), pp. 2 to 4; brochure 42832540504 (09/2017), pp. 3 and 4.
  6. NEEP cold-climate heat pump list, records 399251, 399252, 399253, 399254, 399255, 399256, modified August 24, 2026, read October 28, 2026.
  7. ENERGY STAR, Certified Air-Source Heat Pumps, Canadian market (2841437, 2841438, 2841439, 2841440, 2841441, 2841442), read October 28, 2026; search by model for the seven other families (R4H5S, N4H5S, H4H5S, H4H7T, HCH6, HSH6, HSH4), November 5, 2026.
  8. airgreen.ca product sheets (coil widths, indicative LogisVert amounts), re-read October 29, 2026.

LogisVert amounts are indicative. Only Hydro-Québec confirms the amount granted. Pricing by quote.