Central Heat Pump ADD-ON ARCOAIRE QuietComfort Compact | 2 Tons - 24,000 BTU (Coil DLFULA 14.5 in.) - R410A
A heat pump on a narrow electric furnace, even when space is tight
In townhouses and small homes, the electric furnace often sits in a closet or a corner of the basement where every inch counts. The Central Heat Pump ADD-ON ARCOAIRE QuietComfort Compact | 2 Tons - 24,000 BTU (Coil DLFULA 14.5 in.) - R410A is designed for these narrow furnaces. It pairs the DLCURAH24ABK outdoor unit with the DLFULAH24XAX coil, which is installed on the existing furnace; the heat pump heats and cools through the same ducts, and the furnace's elements only serve as backup.
Its certified ratings are 16.1 SEER2, 10.7 EER2 and 9.8 HSPF2. The system is ENERGY STAR certified with the cold-climate designation under ENERGY STAR ID 2841438, its certificate still lists capacity at -25 °C, and our product sheet shows an indicative LogisVert amount of $2,688.
The 14.5 in. coil and the ADD-ON approach
In an ADD-ON system, the electric furnace keeps its role as blower, and its elements become the backup heat. The heat pump coil sits on its air outlet: when the heat pump runs, the furnace blower pushes air through that coil, which warms it in winter and cools it in summer.
For all the air to pass through the coil, its width must match the furnace's. The 14.5 in. coil is meant for narrow furnaces, common in compact homes. The same system is also available with a wider coil for larger furnaces; we measure your unit on site before confirming the model.
The homes it is meant for
The 2-ton size, or 24,000 BTU/h, often suits a townhouse on two or three levels, a bungalow with a basement or a semi-detached house in Laval or on the North Shore, heated by an electric furnace still in good condition. These homes have often never had central air conditioning, for lack of space for another unit.
The size is confirmed by a room-by-room on-site assessment that accounts for insulation, windows and orientation. In an ADD-ON system, we choose the size first for cooling, then check the share of heating the heat pump will be able to take on before the furnace's elements take over.
Why keep the furnace
Keeping an electric furnace in good condition as backup has several advantages. Its elements already do the backup work, so there are no heating elements to add: only the outdoor unit needs a new circuit, which spares the capacity of the electrical panel, often limited in a townhouse. The work involves the heat pump only, since the furnace, the plenum and the ducts stay in place. Finally, the home keeps two heat sources to get through deep cold: the heat pump for most of the winter, the furnace's elements for the harshest nights.
A certificate that stops at -25 °C
The certificate lists 22,400 BTU/h at -8 °C (17 °F) with a COP of 2.42, about 93% of the nominal size, and 20,000 BTU/h at -15 °C (5 °F) with a COP of 2.00. The two points are measured separately; we report each one as published. Its coldest point is -25 °C, where it lists 16,500 BTU/h with a COP of 1.61.
That last point deserves an explanation. The certificate does not list any colder data, and we do not guess it. In an ADD-ON system, this is hardly an issue: the electric furnace is there for the coldest nights of a Montreal winter. The thermostat brings its elements in as backup as soon as the heat pump can no longer hold the set point. These figures come from certificate AHRI 213372117, published by NEEP.
The thermostat and the electric backup
A compatible thermostat hands the heating to the heat pump first. When, in deep cold, it can no longer hold the set point, the thermostat brings in the electric furnace's elements as auxiliary heat, then takes them out as soon as the heat pump is enough again.
The backup setting depends on the heat pump's capacity, the home's heat loss and your preferences. Backup that comes in too early runs the elements when the heat pump would be enough; backup that comes in too late can leave the house cool in deep cold. We set it during commissioning and adjust it if needed after the first weeks of winter.
What the ratings measure
- 9.8 HSPF2: the heat pump's efficiency over the whole heating season.
- COP of 2.42 at -8 °C: heat delivered divided by electricity used. An electric furnace's elements never deliver more heat than the electricity they receive; the heat pump delivers nearly two and a half times as much here.
- 16.1 SEER2: cooling efficiency over a typical summer.
- 10.7 EER2: cooling efficiency at full load, on a hot day.
Air conditioning, at last
In summer, the heat pump cools every room served by the ducts, including the top-floor bedrooms of a townhouse, often the warmest. Its variable-speed (inverter) compressor slows down as it approaches the set point and runs for long periods at low speed, which removes moisture instead of only cooling the air. The system runs on R-410A, a refrigerant that refrigeration technicians know well.
Indicative LogisVert amount: $2,688
Our product sheet shows an indicative LogisVert amount of $2,688 for the owner of an existing home (Hydro-Québec program, according to the list in effect on the installation date). Only Hydro-Québec confirms the amount granted. The amount corresponds to the certified pairing of the DLCURAH24ABK outdoor unit and the DLFULAH24XAX coil.
We confirm eligibility before signing and prepare the detailed invoice, model numbers and proof of payment. Our page on the efficient heat pump grant summarizes the program's conditions.
Installation on the existing furnace
Installing in a tight space
Before the quote, we check the condition of the electric furnace and its elements, its age, its blower and the airflow it can deliver, along with the duct sizes and the air return. In a mechanical closet, we also measure the height available above the unit: the coil fits between the furnace and the plenum, which is adjusted or rebuilt as needed. If the coil cannot drain by gravity to a floor drain, a condensate pump is included.
The insulated copper line set follows the most discreet route possible to the outdoor unit, mounted on a wall bracket or a stand, above the snow line, away from roof drip. It is brazed, pressure-tested and put under vacuum. The outdoor unit is connected on a dedicated circuit, with an outdoor disconnect, and the thermostat is replaced with a model that manages the heat pump and the furnace's electric backup. Commissioning checks the charge, airflow, defrost and the backup setting.
Maintenance
The furnace filter now serves both units: check it every month in season and replace it according to its format. Keep the outdoor unit clear of snow and leaves, without covering it. Annual HVAC maintenance covers the heat pump's coil, condensate drain or pump and electrical connections, in addition to a check of the electric furnace and its elements. The white vapour during defrost, in winter, is normal.
Warranty
Warranty: 10 years on the compressor, 10 years on parts and 6 years on labor.
AirGreen, for the life of the installation
A family business active for more than fifteen years in Montreal, Laval, Longueuil, the North Shore and the South Shore, we hold RBQ licences for ventilation, refrigeration and electrical work and carry $5,000,000 in liability insurance. The in-home assessment is free, the quote is in writing, and our financing options let you choose the right unit rather than the cheapest one.
Request your free estimate for the Central Heat Pump ADD-ON ARCOAIRE QuietComfort Compact | 2 Tons - 24,000 BTU (Coil DLFULA 14.5 in.) - R410A. We measure your furnace, check the available space and confirm your grant eligibility before signing.