DURASTAR · Central systems · Sirius Heat R-410ADURASTAR Sirius Heat R-410A central systems at AirGreenSold and installed by AirGreen across Montreal, Laval, Longueuil, the South Shore and the North Shore.
Find my DURASTAR
AirGreen × DURASTARSold and installed by AirGreenSirius Heat: down to -30 °CR-410A2 units in this collectionMontreal · Laval · Longueuil · South Shore · North Shore
01 · The DURASTAR selector

Pick a size. Every card is a real DURASTAR listing on our site.

Heat at -8 °C and -15 °C from each listing, the cold limit DURASTAR publishes for the family, and the LogisVert amount when the listing has an AHRI number.

Size

2 units shown

Thermopompe Centrale Mini-Split DURASTAR Sirius Heat | 1.5 Tonnes - 18000 BTU - R410A — installée par AirGreen à Montréal, Laval, Longueuil, Rive-Sud et Rive-Nord
Sirius HeatR-410A

18,000 BTU/h

Mini-splitDRA1H18S1AAHRI 213350738

Heat at -8 °C
15,400 BTU/h
Heat at -15 °C
17,000 BTU/h
Heats down to
-30 °C
SEER2 · HSPF2
17.6 · 9.6
LogisVert$1,848
Thermopompe Centrale Mini-Split DURASTAR Sirius Heat | 2 Tonnes - 24000 BTU - R410A — installée par AirGreen à Montréal, Laval, Longueuil, Rive-Sud et Rive-Nord
Sirius HeatR-410A

24,000 BTU/h

Mini-splitDRA1H24S1AAHRI 213350741

Heat at -8 °C
16,900 BTU/h
Heat at -15 °C
21,200 BTU/h
Heats down to
-30 °C
SEER2 · HSPF2
18.4 · 9.3
LogisVert$2,028

Heat at -8 °C and -15 °C: values from each product listing; when the listing has an AHRI number, they are the ENERGY STAR (or NEEP) figures for that number. Cold limit: operating range published by DURASTAR for the family. “Standard” is our name for DURASTAR’s non-Sirius range.

AirGreen × DURASTAR

DURASTAR on the unit. A local team to install it.

DURASTAR puts its name and its spec sheet on the unit. AirGreen picks it with you, installs it and checks your LogisVert amount. Each does what it does best.

DURASTAR

What DURASTAR brings

  • Sirius Heat: down to -30 °CWith 100% of its rated heating capacity down to -18 °C, per DURASTAR.
  • Sirius Heat: down to -30 °CWith 100% of its rated heating capacity down to -18 °C, per DURASTAR.
  • Central mini-splitA DRA1H or DRA1U outdoor unit paired with a DRAM indoor air handler, per the listings.
  • Outdoor unit + air handlerThe AHRI number covers the pair: it sets the certified heat and the LogisVert amount.
  • R-410AThe previous refrigerant generation.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenMontreal, Laval, Longueuil, the South Shore and the North Shore.
  • Free on-site estimateWe look at your home and choose the family and the size.
  • LogisVert checked by AHRI numberThe amount for the exact AHRI number, in Hydro-Québec’s tool.
  • RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.

The result: the right DURASTAR, chosen with you and installed by AirGreen, with the LogisVert amount checked.

02 · How it works

Heat pump outside, ducts inside.

Tap a step to see it on the diagram.

BasementDURASTAR1234

Heating: heat from outside comes into the home.

03 · This collection in numbers

What these 2 listings say, once you line them up.

Every number below is read live from the product listings in this collection. Change a listing and the page follows.

ENERGY STAR2/2listings listed as ENERGY STAR cold climate
Most heat at -15 °C94 %of the model’s nominal size: its listing shows that much heat at -15 °C (ENERGY STAR maximum at 5 °F). The highest here: the 18,000 BTU/h Sirius Heat R-410A
SEER217.6 to 18.4Seasonal cooling efficiency across these listings: higher means less electricity for the same cooling
The quietest inside35 dB(A)lowest indoor sound level listed, on the 18,000 BTU/h Sirius Heat R-410A
Outdoor models2different DURASTAR outdoor units behind these 2 listings: DRA1H18S1A, DRA1H24S1A
Wi-Fi2/2listings where Wi-Fi control is offered as an option

SEER2, listing by listing

Tap a bar to open its listing.
04 · The cold

How much heat is left when it gets cold, listing by listing.

Dark bar: heat at -8 °C. Light bar: at -15 °C. On the right, the limit DURASTAR publishes for each family.

The cold limit, by family

Sirius Heat
-30 °C

“Down to”: heating operating range from DURASTAR’s spec sheets (Sirius Heat: -22 °F / -30 °C; non-Sirius: -13 °F / -25 °C; 115 V: -4 °F / -20 °C). Sirius Heat keeps 100% of its rated heating capacity down to 0 °F (-18 °C). DURASTAR publishes no minimum for Advanced and Core.

Why the light bar is sometimes longer: in ENERGY STAR’s listing, the -8 °C (17 °F) figure is the capacity at the certification test point, while the -15 °C (5 °F) figure is the maximum capacity. Both come from the same AHRI number.

Slide the thermometer

-20 °C
Sirius Heatdown to -30 °CHeats

Move the slider: we count how many of the 2 units in this collection are still inside the heating range DURASTAR publishes.

05 · One system, two listings

Outside, the heat pump. Inside, the air handler.

On our site, each central system also exists as an “electric furnace”: that is the indoor air handler (blower) of the same system, same series, same size. Tap a side to see what it does.

The same systems, seen as their indoor air handler2 listings →
06 · Did you know?

6 facts about these DURASTAR units and how they work. Flip the cards.

07 · Good to know

What to know before choosing.

01

“Electric furnace”: the indoor unit

On our site, each central system also exists under the name “electric furnace”: it is the indoor air handler (blower) of the same system, same series and same size.

02

Same outdoor unit, other air handler

The “variable speed”, “front return” and “mini-split” listings pair an outdoor unit already listed with another indoor unit. Each combination has its own AHRI number, so its own certified heat and its own amount.

03

Central mini-split: DRA1H or DRA1U with a DRAM air handler

The Sirius Heat and Standard R-410A central systems in our catalogue are central mini-splits: a mini-split outdoor unit (DRA1H or DRA1U) paired with a DRAM indoor air handler, per the listings.

08 · The DURASTAR range at AirGreen

The neighbouring DURASTAR collections.

Number of units on our site, live.

09 · LogisVert

Up to $2,028 on these listings: the amount follows the AHRI number.

Hydro-Québec pays $120 per 1,000 BTU/h of heat at -8 °C for an ENERGY STAR cold-climate heat pump, $50 for a standard ENERGY STAR one, if the outdoor unit is at least 12,000 BTU/h.

Listings with a LogisVert amountAHRI number on the listing
2
Listings “on quote”no AHRI number, or an amount we still have to confirm
0
Under 12,000 BTU/h outsidenot eligible
$0

Amounts come from each product listing, by AHRI number, from Hydro-Québec’s LogisVert tool. Only Hydro-Québec confirms the aid granted.

Where we install

4,632 installs published on our blog, all brands.

Count of published “Nos réalisations” articles by region, October 6, 2026. 343 articles with no recognized city are not in the bars.

See our installs
Montreal2,403
Longueuil and South Shore614
Laval487
North Shore401
West Island343
Vaudreuil-Soulanges41
10 · Questions

What people ask us about these DURASTAR units.

I want to keep my furnace

That is the ADD-ON setup: we add the outdoor heat pump and a coil on the existing furnace. See the DURASTAR ADD-ON collection.

Can my current ducts be used?

We talk about it during the free estimate, with your home in front of us.

How much is an installed DURASTAR?

Every installation is different: the estimate is free and the price comes with the quote.

Who makes DURASTAR?

DURASTAR is the house brand of Ferguson, a large North American heating and cooling distributor; in Canada, Ferguson does business as Wolseley. The Advanced and Core central systems are warranted by Rheem Sales Company. DURASTAR does not publish who makes its mini-splits.

AirGreen × DURASTARSold and installed by AirGreenSirius Heat: down to -30 °CR-410ARBQ 5645-9605-01
Sources

Sources checked on October 8, 2026

  1. DURASTAR product pages and spec sheets (Sirius Heat and non-Sirius mini-splits, R-454B V1.1 Jan. 2025 and R-410A; Elite central V1.3 May 2026; Advanced PDS-848 and Core PDS-846, 2025), durastar.com.
  2. DURASTAR submittal DRA4U28M2A (form V1.0_10.24, © 2024 Ferguson Enterprises): heating operating range -13 to 75 °F (-25 to 24 °C).
  3. DRHP heat pump and DRAH air handler limited warranty (document 92-26150, Rheem Sales Company).
  4. ENERGY STAR certified air-source heat pumps (data.energystar.gov, dataset w7cv-9xjt) and NEEP, by AHRI number, as carried on each product listing.
  5. Hydro-Québec, LogisVert heat pump search tool and residential participation guide v1.10, September 15, 2026.
  6. AirGreen: DURASTAR catalogue on airgreen.ca, read live from this collection.

LogisVert amounts come from Hydro-Québec’s tool; only Hydro-Québec confirms the aid granted.

Price on quoteEvery installation is different: the estimate is free and the price comes with the quote.

The DURASTAR shop

The 2 units of this collection, right below.

Filter by capacity, then compare the product listings. When a listing has an AHRI number, its LogisVert amount is shown.

DURASTAR