Home / Comparisons / 12,000 BTU wall heat pumps
HITACHI airHome 800 and LG ARTCOOL DELUXE R32: what each manufacturer states, what the certificate measures
Two 12,000 BTU R-32 wall units, ENERGY STAR cold-climate certified. Each manufacturer states a heating range; NEEP, for its part, publishes points measured at specific temperatures. The coldest certified point is at −30 °C for the HITACHI and −35 °C for the LG. This page separates the two layers, unit by unit.
Pale band: cold part of the stated heating range; dot: coldest certified temperature (NEEP).
What the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. In cooling, the HITACHI certificate gives 12,500 BTU/h and the LG one 12,000: the calculation uses the common nominal size, 12,000 BTU/h. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the point of reference.
How this amount is calculated
- Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.
Two layers per unit: the stated range and the measured points
The outer layer is the operating range each manufacturer states in its brochure. The inner layer is the temperatures where NEEP publishes a certified measurement. In between, each manufacturer adds its own figures. Tap a layer to see its source.
Same temperature scale for both, from −40 to 50 °C. Dark band: heating; pale band: cooling. Dots: certified test temperatures (NEEP); diamonds: temperatures where the manufacturer publishes a maximum capacity outside the certificate. A stated range says how far the unit is designed to operate; it does not say what capacity it delivers at the limit.
Below −15 °C: every published number, at its exact temperature
At −15 °C, both are certified at the same point: 15,200 and 14,700 BTU/h maximum. Lower down, the brochures publish their own maximum capacities; the coldest certified points are at −30 °C for the HITACHI and −35 °C for the LG.
What each manufacturer writes, group by group
HITACHI: airHome 800 brochure (December 2024) and technical catalogue. LG: ARTCOOL MIRROR / DELUXE R32 brochure (2025).
airHome 800 : HeatForce; Adaptive Defrost Technology; heated base pan (NEEP record, 150 W).
ARTCOOL DELUXE : Extreme Cold Performance; heated base pan (NEEP record, 90 W).
airHome 800 : motion sensor, Smart Eco, Smart-Fence.
ARTCOOL DELUXE : built-in occupancy sensor.
airHome 800 : FrostWash 3.0, Mold Guard 2.0, PM2.5 filter.
ARTCOOL DELUXE : Auto Clean+, Freeze Clean through the ThinQ app.
airHome 800 : airCloud Go app, voice control; RC-BGH1FA0N remote; airPoint Room H700 wall control optional.
ARTCOOL DELUXE : ThinQ app named for Freeze Clean; wireless remote; no Wi-Fi module named in the brochure.
airHome 800 : 5 speeds published in heating, from 30 to 48 dB(A).
ARTCOOL DELUXE : Efficient Airflow; 3 speeds in heating, plus a very low speed in cooling.
airHome 800 : weekly timer, SleepSense.
ARTCOOL DELUXE : not published in the brochure read.
airHome 800 : type not specified in the brochure read.
ARTCOOL DELUXE : twin-rotary inverter.
airHome 800 : 3.0 L/h per the brochure.
ARTCOOL DELUXE : 3.59 pints/h (1.7 L/h) per the brochure.
airHome 800 : heating −30 to 24 °C, cooling −20 to 46 °C.
ARTCOOL DELUXE : heating −35 to 18.3 °C (wet bulb), cooling −10 to 47.8 °C.
Five speeds on one side, three on the other
HITACHI publishes five levels in heating; its technical catalogue describes the measurement conditions. LG publishes three levels in heating in its brochure, and a fourth, very low one in cooling.
How to read these numbers. dB(A) measures a noise level the way the ear perceives it: the lower the number, the quieter the unit. Each dot is a published fan speed, from slowest to fastest.
Why this is not a ranking. The two manufacturers do not measure the same way, and their speeds do not line up: the lowest heating speed is 30 dB(A) at HITACHI and 27 at LG, but nothing says they move as much air.
Indoor unit, in heating
Every published speed
Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.
On the wall, outside and in between
Is your wall wide enough?


Photos scaled to the published width: 41.33 in (105 cm) for the airHome 800, 35 1/4 in (89.5 cm) for the ARTCOOL DELUXE. The yellow band flags a wall narrower than the unit; the clearances each manual asks for come on top.
| Installation | airHome 800 | ARTCOOL DELUXE |
|---|---|---|
| Maximum piping length | 100 ft30 m | 65.6 ftMinimum 9.8 ft |
| Precharged length | Not published by the manufacturerFactory charge 2.65 lb, maximum 2.98 lb | 41 ftBeyond that: 0.16 oz per ft |
| Maximum height difference | 65.6 ft20 m | 39.4 ft |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Outdoor unit W × H × D, weight | 33.46 × 25.59 × 11.73 in, 91 lb | 34 1/4 × 25 19/32 × 13 in, 99.2 lb |
| Indoor unit, weight | 30.07 lb41.33 × 11.73 × 10.03 in | 24.3 lb35 1/4 × 12 3/32 × 9 1/4 in |
| Electrical protection | MCA 14 A; maximum protection (MOP) 25 A | MCA 15 A; maximum protection (MOCP) 20 A |
| Heated base pan | YesNEEP record 484774: 150 W | YesNEEP record 383065: 90 W, on at 0 °C and below |
| Dehumidification | 3.0 L/h | 1.7 L/h3.59 pints/h per the brochure |
| Advertised heating / cooling range | −30 to 24 °C / −20 to 46 °C | −35 to 18.3 °C / −10 to 47.8 °CUpper heating limit at wet bulb |
HITACHI, airHome 800 brochure (December 2024, Johnson Controls-Hitachi). LG, ARTCOOL MIRROR / DELUXE R32 brochure (2025), 12,000 BTU column. Base pan: NEEP records.
What people ask about these two wall units
Why doesn't the page compare −30 and −35 °C?
Because they are two different temperatures. NEEP certifies the HITACHI at −30 °C (6,000 BTU/h maximum) and the LG at −35 °C (9,100 BTU/h). Capacity drops as it gets colder: comparing those two figures would give a false picture. The page shows each one at its own temperature.
What does a range stated down to −35 °C guarantee?
An operating range says how far the manufacturer designed the unit to run. On its own, it does not say how much heat it gives at the limit: for the LG, the point certified by NEEP at −35 °C, 9,100 BTU/h maximum, is what puts a number on it.
What does “18.3 °C wet bulb” mean at LG?
It is a temperature measured with a wet-bulb thermometer, which takes the air’s humidity into account. HITACHI publishes its upper heating limit as an ordinary temperature (24 °C). The two upper limits therefore do not compare directly.
LG writes 113% at −15 °C: 113% of what?
Of the rated heating capacity LG publishes for this model, 13,000 BTU/h: 14,700 BTU/h at −15 °C, 14,550 at −18 °C, 14,000 at −20 °C and 13,000 at −25 °C. At −15 °C, LG’s value is also the certificate’s.
Why does the HITACHI certificate say 12,500 BTU/h?
It is the certified rated cooling capacity at 35 °C. The LG’s is 12,000 BTU/h. So that both are calculated the same way, the cost estimate uses 12,000 BTU/h, the common nominal size.
Are they eligible for grants?
Eligibility depends on the official list in effect on the purchase date. This page promises no amount; the current list is checked when the quote is prepared.
All AHRI and NEEP values
| Certified value | airHome 800 | ARTCOOL DELUXE |
|---|---|---|
| Cooling | ||
| 35 °C: min. / rated / max.BTU/h | 5,000 / 12,500 / 14,000 | 3,070 / 12,000 / 14,100 |
| SEER2 | 25.0 | 25.5 |
| EER2 | 14.5 | 13.8 |
| Heating, same conditions | ||
| HSPF2 Region IV / V | 11.5 / 8.7 | 11.2 / 8.4 |
| 8.3 °C: min. / rated / max.BTU/h | 4,700 / 12,500 / 19,000 | 3,070 / 13,000 / 20,000 |
| 8.3 °C: COP min. / rated / max. | 2.81 / 3.13 / 3.26 | 4.74 / 4.10 / 2.93 |
| −8.3 °C: min. / rated / max.BTU/h | 4,500 / 11,000 / 16,800 | 2,627 / 8,400 / 16,820 |
| −8.3 °C: COP min. / rated / max. | 1.78 / 2.93 / 2.15 | 1.92 / 2.71 / 2.14 |
| −15 °C: min. / rated / max.BTU/h | 3,500 / 10,500 / 15,200 | 2,388 / 14,700 / 14,700 |
| −15 °C: COP min. / rated / max. | 1.39 / 2.09 / 2.12 | 1.79 / 2.05 / 2.05 |
| Coldest point — different temperatures, not highlighted | ||
| Test temperature | −30 °C (−22 °F) | −35 °C (−31 °F) |
| Capacity min. / max. | 1,760 / 6,000 BTU/h | 1,365 / 9,100 BTU/h |
| COP at maximum capacity | 1.06 | 1.33 |
| Certifications and refrigerant | ||
| ENERGY STAR / cold climate (NEEP) | Yes / Yes | Yes / Yes |
| AHRI certificate · NEEP record | 215911631 · 484774 | 216368960 · 383065 |
| RefrigerantGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2L | R-32 · GWP 675 · A2L |
higher marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities and COPs at each point are not highlighted: the order changes depending on the point.
Both are on the AirGreen website.
To choose for your home, talk to our team: bring the width of the planned wall, the distance to the outdoor location and how the room is used in winter.
Where each number comes from
Data verified on November 10, 2026. Performance: AHRI certificates and the NEEP database. Ranges, non-certified capacities, sound, dimensions, piping and features: according to the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails.
Trademarks. HITACHI, airHome, LG and ARTCOOL are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a dealer for these brands; this page is not produced, sponsored or endorsed by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us: every reported figure is checked again.