FUJITSU AIRSTAGE ALTAIR 300 and ALTAIR 500, 12,000 BTU

Home / Comparisons / 12,000 BTU wall-mounted heat pumps

Comparison · Wall-mounted heat pump · 12,000 BTU

FUJITSU AIRSTAGE ALTAIR 300 and ALTAIR 500: what changes from one series to the next

Two 12,000 BTU FUJITSU AIRSTAGE wall units on R‑32, at 208/230 V, sold by AirGreen. At −15 °C, the ALTAIR 300 is certified for slightly more maximum heat; over a season, the ALTAIR 500 has the higher certified efficiencies. Both figures are true: they do not measure the same thing.

Maximum at −15 °C: 8,800 and 8,500 BTU/hSEER2 18.0 and 24.0HSPF2 IV 9.0 and 10.5Last certified point: −15 °C for both
FUJITSU AIRSTAGE ALTAIR 300 12,000 BTU (AirGreen image)
FUJITSU AIRSTAGE

ALTAIR 300 12,000 BTU

ASUH12KNAS / AOUH12KNAS1 · AHRI 217505656

See the product page
FUJITSU AIRSTAGE ALTAIR 500 12,000 BTU (AirGreen image)
FUJITSU AIRSTAGE

ALTAIR 500 12,000 BTU

ASUH12KPAS / AOUH12KPAS1 · AHRI 215212610

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as a reference point.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, the Montréal design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and for the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is meant to compare units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.

Peak and season

Peak output and seasonal efficiency do not tell the same story

Each unit is a point on two axes. Vertically, the certified maximum heat at one test temperature. Horizontally, the efficiency over a full season. Change the temperature or the seasonal measure: both points move.

Height: maximum heat at
Width: seasonal efficiency

Height: the peak

The maximum heat the unit delivers at full speed, measured at a single temperature, in a laboratory test. It is a snapshot: it tells you what the unit can give at the most demanding moment.

Width: the season

The HSPF2 divides the heat of an entire season by the electricity consumed, taking into account every winter temperature and the electric backup. The SEER2 does the same for summer. It is a film: it is what weighs on the bill.

AHRI certified values published by NEEP (records 372687 and 392096), accessed November 9, 2026. Region IV: the standard’s reference climate; Region V: colder. No score is calculated: each axis is a published value.

The peak, temperature by temperature

Maximum heat changes sides with the temperature

At 8.3 °C and at −8.3 °C, the ALTAIR 500 is certified for more maximum heat. At −15 °C, it is the ALTAIR 300, by 300 BTU/h. At the −15 °C rated point, the order reverses again: 8,200 and 8,500 BTU/h. Bar: maximum capacity; yellow tick: rated capacity.

Extreme cold

Below −15 °C: the last published figure, then the stated range

NEEP certifies both units at −15 °C, under the same conditions: 8,800 and 8,500 BTU/h maximum, with COPs of 2.08 and 2.29. The manufacturer’s published heating range stops there, for both units. Lower down, no document gives a capacity; at each temperature, the table shows the last published figure and what the manufacturer writes.

At −15 °C, the same heat does not cost the same electricity. The ALTAIR 300 delivers 8,800 BTU/h with a COP of 2.08; the ALTAIR 500 delivers 8,500 BTU/h with a COP of 2.29. The ALTAIR 300 technical manual (DR_AS255ES_01) confirms the range: its heating capacity table does not go below 5 °F (−15 °C).
Documented features

What each document names

FUJITSU AIRSTAGE technical manual DR_AS255ES_01 (ALTAIR 300, 208/230 V) and brochure FG8151D (ALTAIR 500). Each card repeats what the manufacturer writes.

Modes

ALTAIR 300: Auto, Cool, Dry, Fan, Heat; Powerful and Economy buttons on the remote.

ALTAIR 500: Economy, Energy Saving, Powerful, Minimum Heat; automatic defrost.

Indoor fan

ALTAIR 300: 4 speeds (High, Medium, Low, Quiet).

ALTAIR 500: 6 speeds and Auto.

Controls and Wi-Fi

ALTAIR 300: wireless remote; Wi-Fi with the optional UTY-TFSXH4 WLAN adapter.

ALTAIR 500: backlit wireless remote; Wi-Fi and the AIRSTAGE Mobile app with a compatible USB WLAN adapter.

Restart after a power outage

ALTAIR 300: automatic restart.

ALTAIR 500: automatic restart.

Filter and maintenance

ALTAIR 300: filter maintenance reminder, adjustable interval.

ALTAIR 500: washable filter; ProCore copper indoor coil.

Network and thermostats

ALTAIR 300: adjustable fixed modes (heat pump, heating only, cooling only).

ALTAIR 500: BACnet and Modbus, external inputs and outputs.

Sound

How loud each one is, according to FUJITSU AIRSTAGE

Four published speeds for the ALTAIR 300, six for the ALTAIR 500, with a sound pressure in dB(A) for each. Outside, both units are rated at 48 dB(A).

dB(A)

How to read these figures. dB(A) measures a noise level as the ear perceives it: the lower the figure, the quieter the unit. The dots run from Quiet, the slowest speed, to High.

Why this is not a ranking. Speeds do not correspond to the same airflow from one series to the other, and the documents come from two kinds of publication (technical manual, brochure). They do not state the measuring distance.

Indoor unit, in the room

Cooling, all published speeds

Outdoor unit, outside

Cooling and heating

Measurements published by FUJITSU AIRSTAGE for each series, with no distance stated: read them as reference points, not as a ranking.

Installation

On the wall, outside, in the piping

Indoor units to scale

ALTAIR 3009 13/16 × 30 5/16 × 8 9/16 in
ASUH12KNAS indoor unit to scale
30 5/16 in
ALTAIR 50010 5/8 × 32 13/16 × 8 3/4 in
ASUH12KPAS indoor unit to scale
32 13/16 in

The ALTAIR 300 is 2 1/2 in narrower and 13/16 in shorter, at 17 lb instead of 21 lb. Outside, both units list the same width, 26 1/8 in.

InstallationALTAIR 300ALTAIR 500
Maximum piping length65 ft20 m, minimum 10 ft (manual DR_AS255ES_01, p. 46).66 ft20 m, minimum 10 ft (brochure FG8151D). Same length in metres.
Precharged length49 ft49 ft
Maximum height difference49 ft49 ft
Liquid – gas diameters1/4 – 3/8 in1/4 – 3/8 in
Outdoor unit W × H × D, weight26 1/8 × 21 5/16 × 11 7/16 in, 55 lb26 1/8 × 21 5/16 × 11 7/16 in, 57 lb
Indoor unit, weight17 lb21 lb
Power supplyPer the manufacturer208/230 V, 60 Hz208/230 V, 60 Hz; 15 A breaker
Dehumidification1.57 L/h1.59 L/h
Stated heating / cooling range−15 to 24 °C / 10 to 50 °C−15 to 24 °C / −10 to 50 °C

ALTAIR 300: technical manual DR_AS255ES_01 (September 5, 2025), models ASUH12KNAS and AOUH12KNAS1 at 208/230 V. There is also a 115 V ALTAIR 300, with other model numbers; it is not compared here. ALTAIR 500: brochure FG8151D (rev. 4/2025).

Frequently asked questions

What people ask about these two ALTAIR units

Why does the ALTAIR 300 have more maximum heat at −15 °C, with a lower HSPF2?

They are two different measurements. NEEP certifies 8,800 BTU/h maximum at −15 °C for the ALTAIR 300 and 8,500 for the ALTAIR 500: that is a single point, at full speed. HSPF2 (9.0 and 10.5 in Region IV) sums up a whole season, at every temperature and every speed. At −15 °C, the ALTAIR 500 also delivers its heat with a higher COP, 2.29 versus 2.08.

What exactly does HSPF2 measure?

The heat delivered over a heating season, in BTU, divided by the electricity consumed, in watt-hours, under the AHRI 210/240 standard. Region IV is the standard’s reference climate, Region V a colder climate. It is the value used for the cost calculation higher up on this page.

Which one is ENERGY STAR certified?

The ALTAIR 500 (AHRI certificate 215212610) is in the ENERGY STAR directory, certified April 17, 2026, without the cold climate designation. AHRI certificate 217505656 for the 208/230 V ALTAIR 300 is not listed there (accessed November 9, 2026), and NEEP shows it as not certified.

Is the ALTAIR 300 more compact?

Indoors, yes: 9 13/16 × 30 5/16 × 8 9/16 in and 17 lb, versus 10 5/8 × 32 13/16 × 8 3/4 in and 21 lb for the ALTAIR 500. Outside, both units have the same published dimensions, 26 1/8 × 21 5/16 × 11 7/16 in, at 55 and 57 lb.

What happens below −15 °C?

No document puts a figure on it. For the ALTAIR 300 as for the ALTAIR 500, −15 °C is both the coldest point certified by NEEP and the bottom of the published heating range. If the heat pump has to carry most of the heating below that, compare it with series certified at −25 or −30 °C.

Are they eligible for rebates?

Eligibility depends on the official list in force on the date of purchase. This page promises no amount; the current list is checked when you get your quote.

Certified data

All AHRI and NEEP values

Certified valueALTAIR 300ALTAIR 500
Cooling
Rated capacity at 35 °C12,000 BTU/h12,000 BTU/h
SEER218.024.0
EER210.3511.7
Heating, same conditions
HSPF2 Region IV / V9.0 / 7.2410.5 / 7.9
8.3 °C: min. / rated / max.BTU/h3,100 / 12,000 / 13,9002,700 / 14,000 / 17,000
8.3 °C: COP at min., rated, max.4.33 / 3.35 / 2.456.09 / 3.80 / 3.69
−8.3 °C: min. / rated / max.BTU/h2,700 / 7,500 / 10,1002,900 / 8,700 / 11,000
−8.3 °C: COP at min., rated, max.2.64 / 2.62 / 2.394.05 / 2.86 / 2.69
−15 °C: min. / rated / max.BTU/h1,400 / 8,200 / 8,8002,100 / 8,500 / 8,500
−15 °C: COP at min., rated, max.1.64 / 2.18 / 2.082.56 / 2.29 / 2.29
Coldest certified point — the same for both
Test temperature−15 °C (5 °F)−15 °C (5 °F)
Capacity min. / max.1,400 / 8,800 BTU/h2,100 / 8,500 BTU/h
COP at maximum output2.082.29
Certifications and refrigerant
ENERGY STAR / cold climateNo / NoNot in the ENERGY STAR directoryYes / No
AHRI certificate · NEEP record217505656 · 372687215212610 · 392096
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-32 · GWP 675 · A2L

higher marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities and COPs by test point are not highlighted: the order changes with the point you read.

Both are on the AirGreen website.

To choose for your room, talk it over with our team: bring the room dimensions, the planned outdoor location and your current heating.