Heat pump noise: how to read dB(A)

Home / Comparisons / Guides

Guide · Noise · Reading a spec sheet

Heat pump noise: how to read dB(A)

A spec sheet lists 19, 23, 47 or 65 dB(A). These figures do not all measure the same thing. Some are a sound pressure, picked up by a microphone at a precise spot. Others are a sound power, which belongs to the source itself. This guide shows how to read them, using the documents of two units sold by AirGreen.

dB(A): A-weighted decibels Pressure: what a microphone picks up Power: what the source emits
FUJITSU AIRSTAGE ORION XLTH 12,000 BTU (AirGreen image)
ExampleFUJITSU AIRSTAGE

ORION XLTH · 12,000 BTU

ASUH12KZAS and AOUH12KZAH1 · AHRI 214888802

See the product page
GREE EXTRÊME R32 12,000 BTU (AirGreen image)
ExampleGREE

EXTRÊME R32 · 12,000 BTU

GWH12AVDXE-D6DNA1B/I and /O · AHRI 215386290

See the product page
Cost per season

The least noisy setting is also the one that moves the least air

On both examples, the lowest noise figure of the indoor unit goes with the lowest fan speed, and so with the smallest airflow. Outdoors, FUJITSU AIRSTAGE states that its low-noise mode slows the compressor and the fan, and that performance may drop depending on conditions. This guide shows no dollar amount: the cost of a season is worked out unit by unit, from the certified HSPF2 Region V, and it appears in our comparison pages.

ORION XLTH FUJITSU AIRSTAGE200 to 571 CFMIndoor unit airflow in heating, from Quiet speed to High speed
EXTRÊME R32 GREE212 to 565 CFMIndoor unit airflow, from the smallest to the largest published figure

FUJITSU AIRSTAGE: Design & Technical Manual DR_AS233ES_02, p. 2 and 114, and operating manual, p. 8. GREE: service manual, p. 9. Documents read on November 10, 2026. Each manufacturer measures its airflow in its own way: these two ranges are not ranked against each other.

The dB(A) ruler

Every figure in its place, with its method

The ruler places the values published for the two examples. Each line stands for one unit, one quantity and one way of measuring. Tap a value to see where it comes from.

Operating mode
Lines shown
Everyday reference pointsTypical noise levels
ORION XLTH FUJITSU AIRSTAGEIndoor unitSound pressure
EXTRÊME R32 GREEIndoor unitSound pressure
EXTRÊME R32 GREEIndoor unitSound power
ORION XLTH FUJITSU AIRSTAGEOutdoor unitSound pressure
EXTRÊME R32 GREEOutdoor unitSound pressure
EXTRÊME R32 GREEOutdoor unitSound power
Read this before comparing two lines. Two values can be compared only if the quantity, the place of measurement, the microphone distance and the speed are the same. That is not the case here: FUJITSU AIRSTAGE describes its test chamber and the position of its microphone; the GREE documents consulted give their figures without these conditions. The ruler is there to locate a value, not to rank the units.

Circles are sound pressures, diamonds are sound powers. GREE lists its values from the highest speed to the lowest, without naming the steps: eight in cooling (1,080 to 500 rpm) and seven in heating (1,200 to 800 rpm). We number them from the lowest to the highest. The everyday reference points come from Table 2 of the Canadian Centre for Occupational Health and Safety (CCOHS): they are orders of magnitude, not measurements of appliances.

Pressure or power

Two quantities, so two figures for a single unit

Sound pressure is what a microphone picks up at a given spot: it changes with distance and with the room. Sound power is the energy the source emits every second: it stays the same when the source is moved. Both are expressed in decibels, and that is what causes confusion.

Source Distance Mic The room reflects sound Everything the source emits

The microphone picks up a pressure. Move it back, change rooms, and the figure changes. That is why a sound pressure only makes sense with its distance and its place of measurement.

Diagram. Based on CCOHS, “Noise - Basic Information”.
EXTRÊME R32 GREE

A document that publishes both quantities

Indoor unit, cooling, highest step43Pressure53Power
Indoor unit, heating, highest step45Pressure55Power
Outdoor unit55Pressure65Power

Values in dB(A), GREE service manual, p. 9 and 10. In this document, the gap between the two quantities is 10 dB on every line. CCOHS notes that calculating a pressure from a power requires detailed information about the source's environment.

dB(A)

The “A” stands for a weighting. The measuring instrument de-emphasizes low-pitched sounds, which the ear hears less well, and gives a single number for all frequencies. Source: CCOHS.

+ 3 dB

Sound energy doubles. At + 10 dB it becomes 10 times greater; at + 20 dB, 100 times. Source: CCOHS, Table 3.

76 dB

Natural Resources Canada writes: “Most heat pumps have a sound rating of 76 dB or lower.” The passage refers to the sound power emitted by the outdoor unit.

ORION XLTH FUJITSU AIRSTAGE

A sound pressure, with its conditions

  • Indoor unit: values measured in the manufacturer's anechoic chamber, microphone 1 m in front of the unit and 0.8 m lower.Design & Technical Manual, p. 3 and 33
  • Outdoor unit: semi-anechoic chamber, microphone 1 m behind the unit, on the side opposite the air outlet.Design & Technical Manual, p. 86 and 111
  • Manufacturer's caution: in a real installation, measured levels may be higher because of the surrounding sound environment.Design & Technical Manual, p. 3
EXTRÊME R32 GREE

A pressure and a power, without the conditions

  • The service manual gives a sound pressure level and a sound power level for each unit.Service manual, p. 9 and 10
  • Neither the place of measurement nor the microphone distance appears in the documents consulted.Service manual and brochure No. 032025
  • The brochure repeats 19 to 43 dB(A) for the indoor unit and 55 dB(A) for the outdoor unit, without naming the quantity.Brochure No. 032025
Two noises together

43 dB(A) and 43 dB(A) do not make 86

The decibel is a logarithmic unit. To estimate the level of two sources running at the same time, CCOHS offers a simple method: start from the higher level and add 0 to 3 dB to it, depending on the gap between the two.

43Source 1
and
40Source 2
→
44,5Together, in dB(A)

Estimate based on Table 4 of the CCOHS fact sheet, on adding decibels, which deals with two noise sources present at the same time. Adding a pressure to a power would make no sense.
Outdoors and day to day

The outdoor unit, the neighbours and the low-noise modes

Spec sheet figures describe a unit in a test chamber. The manuals deal with the real installation: where to put the outdoor unit, what to put under it, which settings reduce noise and which sounds are expected.

ORION XLTH FUJITSU AIRSTAGE

What the manuals require and describe

  • Place the outdoor unit where its air outlet, noise and vibration will not disturb the neighbours; if it is close to them, get their approval first.Installation manual, p. 7
  • Depending on the installation, attach damping materials under the outdoor unit, which can vibrate when running.Installation manual, p. 8
  • With less than 3 m of piping, the sound of the outdoor unit may carry to the indoor unit.Installation manual, p. 2
  • A button on the remote control turns on the outdoor unit's low-noise operation: the compressor slows down and the outdoor fan turns slowly. This mode cannot be combined with the Fan, Dry and Powerful modes.Operating manual, p. 8
  • The same mode can be triggered by an external contact; the manufacturer notes that performance may drop depending on conditions, the outdoor temperature for example.Design & Technical Manual, p. 114
EXTRÊME R32 GREE

What the manuals require and describe

  • Choose a spot for the outdoor unit where its noise and the air it blows will not disturb the neighbourhood.Service manual, p. 55
  • Choose a wall for the indoor unit that carries its weight without adding noise or vibration.Service manual, p. 55
  • The owner's manual, shared by several models, describes a night mode: in cooling or heating, with the sleep function and a low or quiet fan speed, the outdoor unit goes into night mode.Owner's manual, PDF p. 22
  • If the heating or cooling effect seems weak, the manual says to change the fan speed or leave the sleep function; night mode only works at normal ambient temperature.Owner's manual, PDF p. 22
Flowing sound at start-up

FUJITSU AIRSTAGE a refrigerant flow sound may be heard, especially for 2 to 3 minutes after start-up. GREE a sound of flowing water comes from the refrigerant circulating; the manual describes it as normal.

Slight creaking or cracking

FUJITSU AIRSTAGE the front panel expands and contracts slightly with temperature. GREE same explanation: friction from the panel or other parts expanding or contracting.

Dirty filter

FUJITSU AIRSTAGE dirt on the filter reduces airflow; efficiency drops and noise increases. The operating manual describes how to clean the filter.

Hissing in heating

FUJITSU AIRSTAGE the operating manual attributes this sound to the automatic defrosting of the outdoor unit.

The remote control beep

FUJITSU AIRSTAGE the indoor unit beeps when it receives a command. GREE a button combination lowers the volume of the indoor unit's beep.

Quiet speed and little air

FUJITSU AIRSTAGE if the room heats or cools poorly, or if the airflow is weak, the troubleshooting section has you check that the fan speed is not set to Quiet.

FUJITSU AIRSTAGE: operating manual, p. 3, 12 and 15. GREE: owner's manual, PDF p. 21 and 24. An abnormal sound during operation falls outside these descriptions: the GREE manual then says to turn the unit off, disconnect the power, and contact the dealer or a qualified professional.

The documents, line by line

What each manufacturer publishes about noise

The values are those of the 12,000 BTU models. When a document does not give a piece of information, the cell says so: this says nothing about the unit's noise.

What the document saysORION XLTHEXTRÊME R32
Indoor unit
Quantity publishedSound pressure level, in dB(A)Design & Technical Manual, p. 2Sound pressure level and sound power level, in dB(A)Service manual, p. 9
Where it is measuredManufacturer's anechoic chamberDesign & Technical Manual, p. 3Not stated in the documents consulted
Microphone position1 m (40 in) in front of the unit and 0.8 m (32 in) lower, centredDiagram, Design & Technical Manual, p. 33Not stated in the documents consulted
Heating, sound pressure23 to 44 dB(A), from Quiet to HighSix speeds: 23, 31, 34, 37, 41, 4432 to 45 dB(A), from the lowest step to the highestSeven steps: 32, 36, 37, 39, 41, 43, 45
Cooling, sound pressure23 to 43 dB(A), from Quiet to HighSix speeds: 23, 31, 34, 37, 41, 4319 to 43 dB(A), from the lowest step to the highestEight steps: 19, 27, 29, 33, 39, 40, 42, 43
Heating, sound powerDoes not appear in the documents consulted42 to 55 dB(A)Seven steps: 42, 46, 47, 49, 51, 53, 55
Cooling, sound powerDoes not appear in the documents consulted29 to 53 dB(A)Eight steps: 29, 37, 39, 43, 49, 50, 52, 53
Published airflow200 to 571 CFM in heating, 200 to 518 in coolingDesign & Technical Manual, p. 2212 to 565 CFMService manual, p. 9
Outdoor unit
Quantity published, outdoor unitSound pressure level, in dB(A)Design & Technical Manual, p. 86Sound pressure level and sound power level, in dB(A)Service manual, p. 10
Where it is measured, outdoor unitManufacturer's semi-anechoic chamberDesign & Technical Manual, p. 86Not stated in the documents consulted
Microphone position, outdoor unit1 m (40 in) behind the unit, centredDiagram, Design & Technical Manual, p. 111Not stated in the documents consulted
Sound pressure value47 dB(A) in cooling, 47 dB(A) in heating55 dB(A)
Sound power valueDoes not appear in the documents consulted65 dB(A)
Low-noise modeOutdoor unit low-noise operation, from the remote control or through an external contactOperating manual, p. 8; Design & Technical Manual, p. 114Outdoor unit night mode, tied to the sleep functionOwner's manual, PDF p. 22
Cautions
Real installationLevels measured on site may exceed the stated valuesDesign & Technical Manual, p. 3Not stated in the documents consulted
NeighboursDo not disturb the neighbours; if close to them, get their approvalInstallation manual, p. 7A spot where the noise and the air blown out do not disturb the neighbourhoodService manual, p. 55

FUJITSU AIRSTAGE: Design & Technical Manual DR_AS233ES_02 (January 17, 2025), confirmed by the 12KZAH1 submittal sheet, version 20250409 A. GREE: service manual “AIRY INVERTER SERIES_R32”, model GWH12AVDXE-D6DNA1B. The columns are not ranked against each other: the measurement methods differ or are not stated. Only the manufacturer's text is authoritative.

Frequently asked questions

The questions we get about heat pump noise

What does dB(A) mean?

The decibel expresses a sound level on a logarithmic scale. The “A” indicates a weighting: the measuring instrument de-emphasizes low-pitched sounds, which the ear picks up less well, and sums all frequencies up in a single number. That is the explanation given by the Canadian Centre for Occupational Health and Safety.

Why does a spec sheet give two figures for a single unit?

Because it publishes two quantities. Sound pressure is what a microphone picks up at a precise spot. Sound power is what the source emits, wherever it is. GREE gives both for the EXTRÊME R32: 55 dB(A) of pressure and 65 dB(A) of power for the outdoor unit. Reading one for the other throws the reading off by 10 dB in this document.

Can two heat pumps be ranked by their dB(A)?

Only if both figures are for the same quantity, measured in the same kind of place, at the same distance and at an equivalent speed. For the two examples in this guide, those conditions are not met: FUJITSU AIRSTAGE describes its chamber and the position of its microphone, and the GREE documents consulted do not give these conditions. So this guide ranks neither of them.

Three decibels more: is that a lot?

In energy terms, yes. According to CCOHS, a 3 dB increase means sound energy is doubled, and a 10 dB increase means energy 10 times greater. These rules are about the energy of the sound; on their own, they do not say how each person perceives it.

Will the noise at my home be the same as on the spec sheet?

Not necessarily. FUJITSU AIRSTAGE measures its values in its own test chamber and warns that levels in a real installation may be higher. CCOHS explains that sound pressure depends on distance and on the surroundings: hard surfaces, the walls of a room for example, reflect sound.

What is the outdoor unit's low-noise mode for?

On the ORION XLTH, it slows the compressor and the outdoor fan to reduce noise outside; the manufacturer notes that performance may drop depending on conditions. On the EXTRÊME R32, the owner's manual describes an outdoor unit night mode, tied to the sleep function, and says to leave it if the heating or cooling effect seems weak.

Is there a noise limit I have to meet at home?

This guide cites no regulatory limit. Before the installation, check your municipality's rules and, in a condominium, those of your building. Both manuals ask you to choose a spot for the outdoor unit that does not disturb the neighbourhood; the FUJITSU AIRSTAGE manual adds getting the neighbours' approval when the unit is placed close to them.

Both examples are on the AirGreen site.

Perceived noise depends on the room, the distance and where the outdoor unit sits. To talk it over with our team, tell us where the two units would go and what is nearby: a bedroom, a patio, a neighbour's window.

Sources and documents

Where each statement comes from

FUJITSU AIRSTAGE, Design & Technical ManualDR_AS233ES_02, January 17, 2025 · p. 2 (airflow and sound pressure levels, ASUH12KZAS), p. 3 (anechoic chamber, caution), p. 33 (microphone position), p. 86 (outdoor unit AOUH12KZAH1), p. 111 (microphone position), p. 114 (low-noise mode through an external contact) · consulted on November 10, 2026 FUJITSU AIRSTAGE, submittal sheet “Submittal 12KZAH1”Version 20250409 A · sound pressure levels and airflow by fan speed, ASUH12KZAS and AOUH12KZAH1 · consulted on November 10, 2026 FUJITSU AIRSTAGE, operating manual, ASUH09-15KZASPart No. 9387602531-04, English version · p. 3 (beep), p. 6 (fan speeds), p. 8 (outdoor unit low noise operation), p. 12 (filter), p. 15 (troubleshooting: sounds) · consulted on November 10, 2026 FUJITSU AIRSTAGE, outdoor unit installation manualPart No. 9300793025-01, English version · p. 2 (piping shorter than 3 m), p. 7 (neighbours), p. 8 (damping materials) · consulted on November 10, 2026 GREE, Service Manual “AIRY INVERTER SERIES_R32”GREE Electric Appliances, Inc. of Zhuhai; GREE Canada copy (greehvac.ca), model GWH12AVDXE-D6DNA1B · p. 9 (indoor unit: sound pressure and sound power, fan speeds, airflow), p. 10 (outdoor unit), p. 55 (location) · consulted on November 10, 2026 GREE, Owner's Manual, Split Air ConditionerNo. 600005068072; GREE Canada copy (greehvac.ca), models GWH09 to 24, including GWH12AVDXE-D6DNA1B · PDF p. 21 (beep), p. 22 (night mode) and p. 24 (sounds described as normal) · consulted on November 10, 2026 GREE Canada, brochure “Système simple zone EXTREME R32” (French)Document No. 032025 · sound levels of 19 to 43 dB(A) and 55 dB(A), quantity not named · recorded on November 6, 2026 Canadian Centre for Occupational Health and Safety, “Noise - Basic Information”Fact sheet last revised November 27, 2024 · sound pressure and sound power, A-weighting, Table 2 (typical noise levels), Table 3 (basic rules), Table 4 (adding decibels) · consulted on November 10, 2026 Natural Resources Canada, “Heating and cooling with a heat pump”“Sound Rating” item among the selection criteria · page modified on December 24, 2025 · consulted on November 10, 2026 NEEP, records 392122 and 389444ORION XLTH (AHRI 214888802) and EXTRÊME R32 (AHRI 215386290): model numbers of the units · consulted on November 10, 2026