Home / Comparisons / 12,000 BTU wall-mounted heat pumps
GREE CLIVIA R32 and GREE EXTRÊME R32: what changes on the certificate, what stays the same
Two GREE wall-mounted series on R‑32, at 12,000 BTU and 230 V, both sold by AirGreen and ENERGY STAR cold climate certified. Their two AHRI certificates read line by line: some values differ, others are identical, including the HSPF2 for the coldest region.
CLIVIA R32 12,000 BTU
GWH12AUCXD-D6DN***/I / GWH12AGCXD-D6DNA4D/O · AHRI 216032436
NEEP “Clivia” series. This platform’s other names
See the product page
EXTRÊME R32 12,000 BTU
GWH12AVDXE-D6DN***/I / GWH12AVDXE-D6DNA1B/O · AHRI 215386290
NEEP “Airy” series. This platform’s other names
See the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as a reference point.
How this amount is calculated
- Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, the Montréal design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and for the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.
AirGreen method v1.1, November 9, 2026. An estimate is meant to compare units under the same conditions. The actual bill depends on the house, insulation, settings and use; this amount is not a promise.
From one series to the other, step by step
Each step is an AHRI certificate value that is not the same for the two units, measured under the same conditions. The step goes up when the EXTRÊME R32 value is the higher one, down when it is the CLIVIA R32 value, and its height follows the gap. What is identical is gathered on the landing, just below.
AHRI certified values published by NEEP (records 383739 and 389444), accessed November 9, 2026. Height of a step: the gap between the two values, in proportion to the CLIVIA R32 value. The steps do not add up and do not make a score. The minimum capacities and their COPs, which also differ, are in the certified data.
The landing: what does not change
The same values on both certificates, and the same in GREE’s documents for both series.
Below −15 °C: two certified points, at the same temperatures
NEEP certifies both units at −15 °C, then at −30 °C, under the same conditions: 11,000 and 12,200 BTU/h maximum at −15 °C, 7,300 and 8,500 BTU/h at −30 °C. Between the two, no point is certified: the table then gives the range between the two published values, with what GREE plots in its service manuals.
What each GREE document names
GREE Canada CLIVIA R32 (document no. 062025) and EXTRÊME R32 (document no. 032025) brochures, the GREE CLIVIA R32 brochure in English, and the GREE service manuals for the Clivia and Airy series. Only the features written in these documents are included.
CLIVIA R32: heating stated down to −30 °C; chassis heating belt on the outdoor unit (service manual).
EXTRÊME R32: heating stated down to −30 °C; outdoor unit base pan heater, active at 0 °C and below (service manual).
CLIVIA R32: down to −29 °C outdoors.
EXTRÊME R32: down to −29 °C outdoors.
CLIVIA R32: “G20 Inverter”.
EXTRÊME R32: “G10 Inverter”; “two-stage variable-speed compressor”; “ultra-high-frequency compressor”.
CLIVIA R32: Wi-Fi; wireless remote with LCD screen; optional wired thermostat.
EXTRÊME R32: Wi-Fi; YBE1FB1F remote.
CLIVIA R32: eight published airflow rates, from 212 to 400 CFM; swing louver control; optional fresh air kit (English brochure).
EXTRÊME R32: “multi-speed fan”; “precise airflow control”; “vertical and horizontal louver swing”.
CLIVIA R32: indoor unit self-cleaning; blue fins tested for 500 hours in salt spray; composite drain pan.
EXTRÊME R32: washable dust filters; fins with anti-corrosion coating.
CLIVIA R32: “artificial intelligence”; “intelligent humidity control”.
EXTRÊME R32: “G-AI Learning”.
CLIVIA R32: refrigerant leak detector.
EXTRÊME R32: the brochure names none.
CLIVIA R32: automatic voltage adaptation (English brochure).
EXTRÊME R32: “low-voltage start-up”; automatic restart (service manual).
A feature missing from a brochure is not necessarily missing from the unit: the document simply does not mention it. Names in quotation marks are GREE’s own terms, translated here from the French brochures.
How loud each one is, according to GREE
GREE Canada publishes eight sound pressure levels for each indoor unit, with no speed names: from 20 to 43 dB(A) for the CLIVIA R32, from 19 to 43 dB(A) for the EXTRÊME R32. Outdoors, one value per unit: 52 and 55 dB(A).
How to read these figures. dB(A) measures a noise level as the ear perceives it: the lower the figure, the quieter the unit. Each dot is a published fan level, from slowest to fastest.
Why this is not a ranking. GREE publishes neither the distance nor the measuring conditions, and the same speed rank does not necessarily match the same airflow from one series to the other.
Indoor unit, in the room
The eight published levels
Outdoor unit, outside
Published value
Measurements published by GREE for each series, with no conditions stated: read them as reference points, not as a ranking.
The GREE CLIVIA R32 brochure in English, undated, prints other values for the same unit: 48, 44 and 40 dB(A) at three speeds, and 62 dB(A) outdoors. The Clivia series service manual gives 62 dB(A) as the sound power of the outdoor unit, and 52 dB(A) as its sound pressure. This page follows the dated document.
On the wall, in the piping, outside
Is your wall wide enough?


Widths published by GREE Canada: 32 61/64 in (CLIVIA R32, document 062025) and 38 3/16 in (EXTRÊME R32, document 032025). The side clearances in the installation manual are added to these; the installer confirms them on site.
Piping length
Per GREE: 24.6 ft precharged for both, then 0.2 oz of refrigerant to add per foot, up to 65.6 ft (CLIVIA R32) and 131.2 ft (EXTRÊME R32, per the brochure). The GREE Airy Inverter R32 service manual shows 65.6 ft for the 12,000 BTU: the maximum length for the EXTRÊME R32 is to be confirmed with your quote.
Indoor units to scale


Same scale for both photos, based on the published width. The EXTRÊME R32 indoor unit is about 5 1/4 in wider, taller and deeper; it weighs 33.1 lb, against 20.9 lb for the CLIVIA R32 unit.
| Installation | CLIVIA R32 | EXTRÊME R32 |
|---|---|---|
| Maximum piping length | 65.6 ft | 131.2 ftEXTRÊME R32 brochure. The GREE Airy R32 service manual shows 65.6 ft for the 12,000 BTU: to be confirmed with your quote. |
| Precharged length | 24.6 ftGREE CLIVIA R32 brochure (English) and service manual; the GREE Canada brochure does not give it. | 24.6 ftGREE AIRY R32 brochure and service manual; the EXTRÊME R32 brochure does not give it. |
| Additional charge beyond the precharged length | 0.2 oz/ft | 0.2 oz/ft |
| Maximum height difference | 39.4 ftGREE Canada; the English brochure and the service manual show 40 ft. | 82 ftEXTRÊME R32 brochure. Service manual: 32.8 ft. |
| Liquid – gas diameters | 1/4 – 1/2 in | 1/4 – 1/2 in |
| Outdoor unit W × H × D, weight | 31 37/64 × 21 27/32 × 13 25/32 in, 67.3 lb | 34 3/8 × 21 27/32 × 14 51/64 in, 78.3 lb |
| Indoor unit W × H × D, weight | 32 61/64 × 11 17/32 × 7 7/8 in, 20.9 lb | 38 3/16 × 13 21/32 × 10 1/8 in, 33.1 lb |
| Electrical protectionPer the manufacturer | MOP 15 A (MCA 10 A) | MOP 15 A (MCA 11 A) |
| Dehumidification | 1.4 L/h | 1.4 L/h |
| Refrigerant and factory charge | R-32, 28.2 oz | R-32, 35.3 oz |
| Stated heating / cooling range | −30 to 30 °C / −29 to 50 °C | −30 to 30 °C / −29 to 50 °C |
GREE Canada brochures (documents no. 062025 and no. 032025). Outdoor unit clearances: owner’s manual for GREE R32 outdoor units (X40270A_2, p. 8, common to the Airy, Charmo and Clivia series), shown as a figure in the manual; the installer measures them on site.
What people ask about these two GREE wall units
What changes on the certificate between the CLIVIA R32 and the EXTRÊME R32?
Mostly cooling and the heating maximums. SEER2 goes from 24.5 to 29.5 and EER2 from 13.0 to 15.2. In heating, the Region IV HSPF2 goes from 9.5 to 10.0, and the maximum certified capacity from 11,000 to 12,200 BTU/h at −15 °C, then from 7,300 to 8,500 BTU/h at −30 °C. The rated COP at −8.3 °C goes the other way: 2.11 for the CLIVIA R32, 2.06 for the EXTRÊME R32.
Why is the estimated winter cost the same for both?
AirGreen’s estimate uses the HSPF2 for Region V, the coldest in the standard, and both certificates give the same value there: 8.0. The difference in the estimate therefore comes from cooling, where the SEER2 values differ. In a real house, maximum capacity in extreme cold also affects the share of backup heating, which this estimate does not break down.
Which one delivers more heat at −30 °C?
NEEP measures both at −30 °C, under the same conditions: 8,500 BTU/h maximum for the EXTRÊME R32 (COP 1.75) and 7,300 BTU/h for the CLIVIA R32 (COP 1.51). That is the coldest certified point for each.
The EXTRÊME R32 brochure shows a SEER2 of 28.0. Why 29.5 here?
GREE Canada brochure no. 032025 prints 28.0; AHRI certificate 215386290, published by NEEP and carried by the ENERGY STAR directory, shows 29.5. When a brochure and the certificate do not agree, this page follows the certificate. The same goes for the COP at 8.3 °C: 4.60 in the brochure, 4.53 on the certificate, and 3.81 against 3.78 for the CLIVIA R32.
Are the two indoor units the same size?
No. The CLIVIA R32 unit is 32 61/64 in wide and weighs 20.9 lb; the EXTRÊME R32 unit is 38 3/16 in wide and weighs 33.1 lb, per GREE Canada. The slider in the Installation section shows what that means on your wall.
Do these series go by other names?
Yes. The EXTRÊME R32 shares AHRI certificate 215386290 with the GREE AIRY R32: same AHRI and NEEP certified values. The CLIVIA R32 belongs to the NEEP “Clivia” series, where several names show similar values. Our pages on the Clivia and Airy platforms give the model numbers and the differences, name by name.
Are they ENERGY STAR certified?
Yes, with the cold climate designation for both, per the ENERGY STAR directory (CLIVIA R32: certified November 7, 2025; EXTRÊME R32: November 20, 2025; market listed: United States).
Are they eligible for rebates?
Eligibility depends on the official list in force on the date of purchase. This page promises no amount; the current list is checked when you get your quote.
All AHRI and NEEP values
| Certified value | CLIVIA R32 | EXTRÊME R32 |
|---|---|---|
| Cooling | ||
| Rated capacity at 35 °C | 12,000 BTU/h | 12,000 BTU/h |
| 35 °C: min. / rated / max.BTU/h | 2,700 / 12,000 / 15,000 | 2,900 / 12,000 / 17,000 |
| SEER2 | 24.5 | 29.5 |
| EER2 | 13.0 | 15.2 |
| Heating, same conditions | ||
| HSPF2 Region IV | 9.5 | 10.0 |
| HSPF2 Region V | 8.0 | 8.0 |
| 8.3 °C: min. / rated / max.BTU/h | 3,070 / 12,000 / 14,600 | 3,270 / 12,200 / 16,200 |
| 8.3 °C: COP at min., rated, max. | 5.62 / 3.78 / 3.72 | 5.04 / 4.53 / 3.77 |
| −8.3 °C: min. / rated / max.BTU/h | 2,700 / 12,000 / 12,000 | 2,800 / 13,000 / 13,000 |
| −8.3 °C: COP at min., rated, max. | 3.04 / 2.11 / 2.06 | 4.32 / 2.06 / 2.06 |
| −15 °C: min. / rated / max.BTU/h | 2,600 / 11,000 / 11,000 | 2,600 / 12,200 / 12,200 |
| −15 °C: COP at min., rated, max. | 3.17 / 1.95 / 1.95 | 4.23 / 2.00 / 2.00 |
| Coldest certified point — same temperature for both | ||
| Test temperature | −30 °C (−22 °F) | −30 °C (−22 °F) |
| Capacity min. / max. | 2,000 / 7,300 BTU/h | 2,600 / 8,500 BTU/h |
| COP at maximum output | 1.51 | 1.75 |
| Certifications and refrigerant | ||
| ENERGY STAR / cold climate | Yes / YesENERGY STAR directory, certified November 7, 2025. | Yes / YesENERGY STAR directory, certified November 20, 2025. |
| ENERGY STAR directory, market listed | United States | United States |
| AHRI certificate · NEEP record | 216032436 · 383739 | 215386290 · 389444 |
| RefrigerantGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2L | R-32 · GWP 675 · A2L |
higher marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities and COPs by test point are not highlighted: the order changes with the point you read.
Both are on the AirGreen website.
To choose for your room, talk it over with our team: bring the room dimensions, the free wall width, the planned outdoor location and your current heating.
Where each figure comes from
Data checked November 9, 2026. Performance: AHRI certificates and the NEEP database. Dimensions, sound, piping and features: per the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails.
Trademarks. GREE, CLIVIA, EXTRÊME and AIRY are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a retailer of this brand; this page is not produced, sponsored or endorsed by the manufacturer.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us: every reported figure is rechecked.