GREE CLIVIA R32 and MIDEA28, 12,000 BTU

Home / Comparisons / 12,000 BTU wall heat pumps

Comparison · Wall heat pump · 12,000 BTU

GREE CLIVIA R32 and MIDEA28, figure by figure

Two 12,000 BTU wall units, ENERGY STAR cold climate certified and offered by AirGreen, one using R-32, the other R-454B. Each heads a family: its certified values appear under other names. This page sets side by side what the AHRI certificates and the two manufacturers publish, from 8.3 °C to −30 °C.

SEER2 24.5 and 25.4HSPF2 Region V 8.0 and 8.0À −30 °C : 7,300 and 5,900 BTU/h max.
GREE CLIVIA R32 12,000 BTU (AirGreen image) GREE

CLIVIA R32 12,000 BTU

GWH12AUCXD-D6DN***/I / GWH12AGCXD-D6DNA4D/O · AHRI 216032436

See the product page

Close relatives: GREE CROSSOVER R32, GREE VIREO R32, GREE ENVO R32 and KINGHOME CLIVIA R32: same certified SEER2, EER2 and HSPF2, with small differences at other points.

MIDEA MIDEA28 12,000 BTU (AirGreen image) MIDEA

MIDEA28 12,000 BTU

MSEHU-H12B-2A / MO1HS-H12B-2A · AHRI 215471381

See the product page

Same NEEP certified values as: SENVILLE AURA R454B, DIRECT AIR HEAT XTREME PRO R-454B and BOSCH Climate 5000 MAX PERFORMANCE R-454B.

Estimated operating cost

What electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference.

Same HSPF2 in Region V, so the same winter. Both AHRI certificates give 8.0 in Region V, the value this calculation uses: winter costs the same amount for both. The difference comes from summer, with SEER2 values of 24.5 and 25.4.
How this amount is calculated
  1. Heat to supply over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for heating around the clock, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ Region V HSPF2, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: this is a maximum, since a variable-speed unit slows down once the room reaches the right temperature.
  4. Price. Hydro-Québec Rate D in force on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Two families

Two widespread platforms, under several names

The certified values of the CLIVIA R32 and the MIDEA28 appear on other 12,000 BTU wall units offered by AirGreen. Pick a value: each card shows what its AHRI certificate says, and differences stand out in yellow. The indoor unit, remote control, app and warranty can vary from one name to the next.

model compared on this pagesame certified valuedifferent value
GREE CLIVIA R32NEEP series “Clivia” · AHRI 216032436
MIDEA28NEEP series “MSE Series” · AHRI 215471381

Sources: NEEP records for each certificate, consulted November 9, 2026 (numbers under “Sources”). In the MIDEA28 family, the four records carry different NEEP series names and identical certified values. In the CLIVIA family, NEEP lists the CROSSOVER R32 under the “Pular” series and the others under “Clivia”; the CLIVIA R32 and the CROSSOVER R32 share the same outdoor unit, GWH12AGCXD-D6DNA4D/O.

The crossover

More heat from the MIDEA28 down to −15 °C; the order reverses at −30 °C

Four temperatures certified by NEEP, the same for both. At full capacity, the MIDEA28 delivers more BTU/h down to −15 °C; at −30 °C, the CLIVIA R32 does. On COP, the CLIVIA R32 is higher at all four points. Nothing is published between −15 and −30 °C: the exact point where the order changes is not known.

CLIVIA R32 GREEMIDEA28 MIDEA

Extreme cold

Below −15 °C: 11,000 versus 11,500 BTU/h, then 7,300 versus 5,900

NEEP certifies both units at −15 °C and at −30 °C, at the same temperatures: these two rows compare directly. In between, neither manufacturer publishes a value; the table then gives the range between the two published points on either side of the temperature, for each unit.

What each manufacturer publishes below −15 °C. GREE Canada (CLIVIA R32 brochure, document no. 062025) states a heating range of −30 to 30 °C; MIDEA Canada (brochure of 2025-08-20) states −30 to 24 °C and prints, at −15 °C, the same 11,500 BTU/h and COP 1.80 as NEEP. Neither brochure gives a capacity figure at −20 or −25 °C. At −30 °C, NEEP also publishes the minimum capacity: 2,000 BTU/h for both.
Documented features

What GREE and MIDEA write in their brochures

GREE Canada CLIVIA R32 brochure (document no. 062025), the English GREE CLIVIA R32 brochure and the MIDEA Canada wall-mounted systems brochure (2025-08-20), whose feature table covers the MIDEA35, 28 and 25 series together. Each line repeats what the manufacturer writes.

Controls

CLIVIA R32: Built-in Wi-Fi; wireless remote with LCD screen; optional wired thermostat.

MIDEA28: Wi-Fi and SmartHome app, optional voice control; optional 7-day programmable wired control; optional 24 V interface; dry contact.

Fan and airflow

CLIVIA R32: several fan speeds (eight published airflows); oscillating louver control; optional fresh-air kit (English brochure).

MIDEA28: fan speed adjustable from 1 to 100%; horizontal and vertical swing; “Follow Me”.

Dehumidification and humidity

CLIVIA R32: 1.4 L/h; humidity control through the artificial intelligence function.

MIDEA28: humidity sensor, dual control of temperature and humidity.

Maintenance and cleaning

CLIVIA R32: indoor unit self-cleaning; self-diagnosis; blue fins tested 500 hours in salt spray.

MIDEA28: automatic cleaning; removable blower wheel for deep cleaning.

Refrigerant leak

CLIVIA R32: refrigerant leak detector included.

MIDEA28: A2L leak detection sensor and A2L dispersion system.

Modes

CLIVIA R32: artificial intelligence control that adapts to the living space; automatic voltage adaptation.

MIDEA28: ECO and “Gear”, Turbo, sleep mode, silent mode, 8 °C heating, smart presence sensor.

The GREE Canada brochure also names the compressor “G20 Inverter”; the MIDEA brochure does not name its compressor for the MIDEA28. A feature missing from a brochure is not necessarily missing from the unit: the document simply does not mention it.

Sound

Eight levels from GREE, five speeds from MIDEA

GREE Canada publishes eight sound pressure levels for the CLIVIA R32 indoor unit, with no speed names. MIDEA publishes five for the MIDEA28, from “Silent” to “Turbo”, without stating whether they are sound pressure or sound power.

dB(A)

How to read these figures. dB(A) measures a noise level as the ear perceives it: the lower the figure, the quieter the unit. Each dot is a fan speed published by the manufacturer, from the slowest to the fastest.

Why this is not a ranking. Neither GREE nor MIDEA publishes the measurement distance or conditions, and MIDEA does not say whether its figure is sound pressure or sound power: different method — not comparable. A gap of a few dB(A) can come from the method as much as from the unit.

Indoor unit, in the room

All published speeds

Outdoor unit, outside

Published value

Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.

Sources: GREE Canada CLIVIA R32 brochure, document no. 062025 (“sound pressure level”); MIDEA Canada brochure of 2025-08-20 (“sound level”). The undated English GREE CLIVIA R32 brochure prints other values for the same indoor unit: 48, 44 and 40 dB(A) at three speeds, and 62 dB(A) outdoors. This page follows the dated document.

Installation

On the wall, in the piping, on the ground

Is your wall wide enough?

36 in
CLIVIA R32 indoor unit to scale

MIDEA28 indoor unit to scale

012 in24 in36 in48 in

Published widths: 32 61/64 in (GREE Canada, 062025) and 31.30 in (MIDEA, 2025-08-20). The side clearances required by each installation manual come on top; the installer confirms them on site.

Piping length

30 ft
end of precharged lengthpublished maximum length

According to GREE (English CLIVIA R32 brochure) and MIDEA (brochure of 2025-08-20): 24.6 ft precharged for both; beyond that, 0.2 oz/ft (CLIVIA R32) and 0.16 oz/ft (MIDEA28) of refrigerant to add, up to 65.6 and 82 ft.

Units to scale

CLIVIA R32indoor 32 61/64 × 11 17/32 × 7 7/8 in
Indoor unit GWH12AUCXD to scale
32.95 in
MIDEA28indoor 31.30 × 11.61 × 8.86 in
Indoor unit MSEHU-H12B-2A to scale
31.30 in
CLIVIA R32outdoor 31 37/64 × 21 27/32 × 13 25/32 in
Outdoor unit GWH12AGCXD to scale
31.58 in
MIDEA28outdoor 31.69 × 21.81 × 12.99 in
Outdoor unit MO1HS-H12B-2A to scale
31.69 in

Same scale for all four photos: the width published by each manufacturer. The outdoor units have almost the same footprint; the CLIVIA R32 is slightly deeper (13 25/32 versus 12.99 in), the MIDEA28 slightly deeper indoors (8.86 versus 7 7/8 in).

InstallationCLIVIA R32MIDEA28
Maximum piping length65.6 ft82 ft
Precharged length24.6 ftGREE CLIVIA R32 brochure (English); the GREE Canada brochure does not give it.24.6 ft
Additional charge beyond the precharged length0.2 oz/ft0.16 oz/ft
Maximum height difference39.4 ftGREE Canada; the English brochure states 40 ft.49.2 ft
Liquid – gas diameters1/4 – 1/2 in1/4 – 3/8 in
Outdoor unit W × H × D, weight31 37/64 × 21 27/32 × 13 25/32 in, 67.3 lb31.69 × 21.81 × 12.99 in, 72.75 lb
Indoor unit W × H × D, weight32 61/64 × 11 17/32 × 7 7/8 in, 20.9 lb31.30 × 11.61 × 8.86 in, 22.93 lb
Electrical protectionAccording to the manufacturerMOP 15 A (MCA 10 A)Max. fuse 15 A (MCA 15 A)
Dehumidification1.4 L/hNot published by the manufacturer.
Refrigerant and factory chargeR-32, 28.2 ozR-454B, 35.27 oz
Stated heating / cooling range−30 to 30 °C / −29 to 50 °C−30 to 24 °C / −30 to 50 °C

Outdoor unit clearances: GREE gives them in the user manual for its R32 outdoor units (X40270A_2, figure p. 8, common to the Airy, Charmo and Clivia series), MIDEA in the service manual for its single-zone outdoor units (figures SC-1 and SC-2, common to all capacities). Both show their values in a figure rather than in a table listing each side; the installer measures them on site.

Frequently asked questions

What people ask us about the CLIVIA R32 and the MIDEA28

Does winter really cost the same with both?

In our estimate, yes: it uses the Region V HSPF2, and both AHRI certificates give 8.0. In Region IV, which is less cold, the values are 9.5 (CLIVIA R32) and 10.5 (MIDEA28). The estimate is not a bill: the house, its insulation and the settings matter more.

Which one heats more in extreme cold?

At −15 °C, NEEP certifies a maximum of 11,000 BTU/h for the CLIVIA R32 and 11,500 for the MIDEA28. At −30 °C, 7,300 and 5,900 BTU/h. Both are measured at the same temperatures, so they can be read side by side; between −15 and −30 °C, no figure is published.

CLIVIA, CROSSOVER, VIREO, ENVO: what is the difference?

These GREE wall units and the KINGHOME CLIVIA R32 share the same SEER2, EER2 and HSPF2 and the same certified points at −15 and −30 °C. They differ on a few values at −8.3 °C and 8.3 °C (see “Two families”), and in their indoor unit, features and documents.

SENVILLE AURA, DIRECT AIR, BOSCH MAX: is it the MIDEA28?

At 12,000 BTU, their NEEP records carry exactly the same certified values as the MIDEA28, under different series names. That says nothing about the indoor unit, the remote control, the app or the warranty, which must be checked for each name.

R-32 or R-454B: what does it change for me?

Both are class A2L refrigerants under ASHRAE 34. Their global warming potential (GWP, IPCC AR4) is 675 for R-32 and 466 for R-454B. Both brochures mention a leak detector; installation follows the requirements specific to each refrigerant.

Which one is quieter?

GREE Canada publishes 20 to 43 dB(A) of sound pressure for the CLIVIA R32; MIDEA publishes 19.5 to 47 dB(A) for the MIDEA28, without stating the method. These figures place each unit; they do not rank them.

Are they eligible for grants?

Eligibility depends on the official list in force on the date of purchase. This page promises no amount; the current list is checked at the time of the quote.

Certified spec sheet

Both AHRI certificates, line by line

Certified valueCLIVIA R32MIDEA28
Cooling
Rated capacity at 35 °C12,000 BTU/h12,000 BTU/h
SEER224.525.4
EER213.013.4
Heating, same conditions
HSPF2 Region IV9.510.5
HSPF2 Region V8.08.0
8.3 °C: min. / rated / max.BTU/h3,070 / 12,000 / 14,6003,800 / 12,000 / 16,000
8.3 °C: COP min. / rated / max.5.62 / 3.78 / 3.724.84 / 3.74 / 3.35
−8.3 °C: min. / rated / max.BTU/h2,700 / 12,000 / 12,0005,300 / 12,000 / 12,800
−8.3 °C: COP min. / rated / max.3.04 / 2.11 / 2.062.22 / 2.51 / 1.75
−15 °C: min. / rated / max.BTU/h2,600 / 11,000 / 11,0004,100 / 11,500 / 11,500
−15 °C: COP min. / rated / max.3.17 / 1.95 / 1.951.72 / 1.80 / 1.80
−30 °C (−22 °F): same temperature for both
−30 °C: capacity min. / max.BTU/h2,000 / 7,3002,000 / 5,900
−30 °C: COP min. / max.2.79 / 1.511.17 / 1.25
Listings and refrigerant
ENERGY STAR / cold climate (NEEP)Yes / YesYes / Yes
ENERGY STAR directory, markets listedUnited StatesUnited States, Canada
AHRI certificate · NEEP record216032436 · 383739215471381 · 387358
RefrigerantGWP according to the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-454B · GWP 466 · A2L

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities and COPs by point are not highlighted: the order changes depending on the point read.

The CLIVIA R32 and the MIDEA28 are both on the AirGreen website.

To choose between the CLIVIA R32 and the MIDEA28, talk to our team: bring the room dimensions, the planned outdoor location and your current heating.

Sources and documents

Where the CLIVIA R32 and MIDEA28 figures come from

NEEP, record 383739 (GREE CLIVIA R32)AHRI 216032436 · “Clivia” series · consulted November 9, 2026 NEEP, record 387358 (MIDEA28)AHRI 215471381 · “MSE Series” · consulted November 9, 2026 GREE Canada, CLIVIA R32 single-zone system brochure (FR)Document no. 062025, © 2025 · dimensions, sound, piping, ranges, features · consulted November 9, 2026 GREE, CLIVIA R32 brochure (EN)Undated · precharged length, additional charge, fresh-air kit · consulted November 9, 2026 MIDEA Canada, Ductless heat pump systems, wall-mounted systems (FR)2025-08-20 · p. 8 features, p. 11 MIDEA28 · consulted November 9, 2026 Hydro-Québec, Electricity RatesApril 1, 2026 · Rate D, article 2.5 · estimated operating cost NRCan, HOT2000 climate map, Montréal Intl4,167 degree-days (18 °C), −23.1 °C design temperature · consulted November 9, 2026
ENERGY STAR directory (data.energystar.gov, dataset 83eb-xbyy)Cold climate: yes for both · consulted November 9, 2026
NEEP, records of the other namesCROSSOVER R32 389378 (AHRI 215402266), VIREO R32 392684 (214813257), ENVO R32 393215 (214779344), KINGHOME CLIVIA R32 369980 (217933620), SENVILLE AURA R454B 385685 (215735296), DIRECT AIR HEAT XTREME PRO R-454B 382480 (216571373), BOSCH MAX PERFORMANCE R-454B 392021 (215223282) · consulted November 9, 2026
GREE, user manual for R32 outdoor unitsX40270A_2, p. 8 · clearances
MIDEA, service manual for single-zone outdoor units (A2L)Figures SC-1 and SC-2 · clearances