Defrost: why the heat pump stops blowing warm air

Home / Comparisons / Winter guides

Guide · Winter · Defrost

Defrost: why the heat pump stops blowing warm air

In winter, frost forms on the outdoor unit. Every so often the heat pump stops heating for a few minutes to melt it: the indicator blinks, steam rises outside, water runs under the unit. Manufacturers describe all of this in their manuals as normal operation. This guide follows the cycle step by step, with what the manuals of two units sold by AirGreen say about it.

FUJITSU AIRSTAGE : 15 minutes at most GREE : the blinking indicator is not an error code Frost depends on temperature and humidity
FUJITSU AIRSTAGE ORION XLTH 12,000 BTU (AirGreen image)
ExampleFUJITSU AIRSTAGE

ORION XLTH · 12,000 BTU

ASUH12KZAS / AOUH12KZAH1 · AHRI 214888802

See the product page
GREE EXTRÊME R32 12,000 BTU (AirGreen image)
ExampleGREE

EXTRÊME R32 · 12,000 BTU

GWH12AVDXE-D6DNA1B/I / GWH12AVDXE-D6DNA1B/O · AHRI 215386290

See the product page
Cost per season

Defrost is part of the heating season

During a defrost, the heat goes to melting the frost outside instead of heating the room. Natural Resources Canada notes that a defrost started when it is not needed lowers a heat pump's seasonal performance. This guide shows no dollar amount: the cost of a season is worked out unit by unit, from the certified HSPF2 Region V, and it appears on our comparison pages.

ORION XLTH FUJITSU AIRSTAGE10.1HSPF2 Region V, AHRI certificate 214888802
EXTRÊME R32 GREE8.0HSPF2 Region V, AHRI certificate 215386290

Bars out of 14. Values read from NEEP records 392122 and 389444 on November 10, 2026. Both units serve as examples; the dollar cost of each is worked out on the page that compares them.

The defrost cycle

Five stages, from the first frost to the return of warm air

The animation follows a defrost from start to finish: what happens outside, what happens inside, and where the heat goes. Pick the example shown to read what its manufacturer writes at each stage.

Example shown
Outside Photo of the unit; frost, steam and water drawn as a diagram
Outdoor unit AOUH12KZAH1 (photo)Outdoor unit GWH12AVDXE-D6DNA1B/O (photo)

Inside Photo of the unit; warm air and indicator drawn as a diagram
Indoor unit ASUH12KZAS (photo)Indoor unit GWH12AVDXE-D6DNA1B/I (photo)

    The general operation is summarized from Natural Resources Canada, “Heating and cooling with a heat pump”, section “The defrost cycle” (the most common approach). The brand boxes summarize, in our own words, the manuals cited under each; durations and thresholds come from those manuals.

    Who decides

    The unit defrosts when its sensors call for it

    Natural Resources Canada describes two families of controls: demand defrost, where sensors detect the frost, and time-temperature defrost, which comes back at fixed intervals. The service manuals of both examples describe logic based on temperature sensors and on compressor running time. Here is what each one publishes.

    ORION XLTH FUJITSU AIRSTAGE

    Compressor running time before a defrost

    Service Manual SR_AS137ES_03 (January 9, 2025), p. 04-23. “Coil”: temperature of the outdoor unit heat exchanger. Diagram.

    EXTRÊME R32 GREE

    Published delays on entering and leaving defrost

    GREE Service Manual “AIRY INVERTER SERIES_R32”, p. 39. GREE describes a time condition and a temperature condition there, without giving figures for the thresholds. Diagram.

    What the manual publishesORION XLTHEXTRÊME R32
    The trigger
    Defrost: what triggers itThe outdoor heat exchanger sensor, compared with thresholds that change with compressor running timeService manual, p. 04-23A time condition, then a temperature condition detected for 3 minutes in a rowService manual, p. 39; thresholds given without figures
    Defrost: delay before the first oneNo defrost before 17 minutes of compressor running timeService manual, p. 04-23No figure in the manuals consulted
    Defrost: delay between twoNo defrost before 40 minutes of compressor running timeService manual, p. 04-23No figure in the manuals consulted
    The end
    Defrost: what ends itThe outdoor heat exchanger reaches 13 °C, or the compressor has run for 15 minutesService manual, p. 04-23The outdoor pipe reaches the set temperature, or the maximum time has elapsedService manual, p. 39; values given without figures
    Maximum length of a defrost15 minutesOperating manual, p. 14; service manual, p. 04-23No figure in the manuals consulted
    What you see
    Indicator during defrostThe operation indicator on the indoor unit blinksOperating manual, p. 14The heat indicator blinks once every 10 seconds; the manual lists it as a status, not as an error codeService manual, p. 65
    Airflow during defrostThe indoor unit stops, for 15 minutes at mostOperating manual, p. 15Not described in the manuals consulted
    Heating start-upThe indoor fan runs at very low speed for 3 to 5 minutesOperating manual, p. 5The indoor unit waits 1 to 5 minutes before blowing air, depending on the room temperatureOwner's manual 600005068072
    Around the defrost
    Defrost when heating is switched offIf the outdoor unit is frosted when you switch heating off, it defrosts before stopping; the indicator blinks slowlyService manual, p. 04-24Not described in the manuals consulted
    Outdoor unit base pan heaterYes; 150 W declared to NEEPService manual parts list (“Base pan heater”); NEEP record 392122Yes; 72 W declared to NEEP, on at 0 °C and below, off above 2 °CService manual, p. 41; NEEP record 389444

    “No figure” and “not described” mean that the manuals consulted say nothing about it; that says nothing about how the unit actually operates. The two columns are not a ranking: each manufacturer documents its own logic.

    The signs

    What you see and hear during a defrost

    Six signs come up in the manuals. None is presented by the manufacturer as a fault.

    The indicator blinks

    FUJITSU AIRSTAGE the operation indicator blinks throughout the operation. GREE the heat indicator blinks once every 10 seconds.

    The warm air stops

    FUJITSU AIRSTAGE the indoor unit stops, for 15 minutes at most, then heating resumes on its own. GREE the manuals consulted do not describe it.

    Steam rises from the outdoor unit

    FUJITSU AIRSTAGE the operating manual attributes it to automatic defrosting. GREE the manuals consulted do not describe it.

    Water runs under the outdoor unit

    FUJITSU AIRSTAGE it is the water produced by defrosting, according to the operating manual. GREE the service manual describes a drain joint to fit under the base.

    A hissing sound

    FUJITSU AIRSTAGE the operating manual attributes it to automatic defrosting, in heating mode. GREE the manuals consulted do not describe it.

    A gentle start

    FUJITSU AIRSTAGE when heating starts, the fan runs very slowly for 3 to 5 minutes. GREE the unit waits 1 to 5 minutes before blowing, so as not to send cold air.

    Sources: FUJITSU AIRSTAGE, operating manual 9387602531-04, pp. 5, 14 and 15; GREE, owner's manual 600005068072 and service manual “AIRY INVERTER SERIES_R32”, p. 65 and the section on installing the outdoor unit. When the issue persists after the checks in its manual, FUJITSU AIRSTAGE asks you to stop the unit, switch off the breaker and call authorized service personnel.

    Frequently asked questions

    The questions we get about defrost

    The warm air stopped and an indicator is blinking. Is it a breakdown?

    Both manuals describe this behaviour as a defrost. FUJITSU AIRSTAGE writes that the operation indicator blinks during the operation and that the indoor unit stops in the meantime. GREE lists the blinking heat indicator among operating statuses, not among error codes.

    How long does a defrost last?

    FUJITSU AIRSTAGE sets a 15-minute ceiling for the ORION XLTH, and its service manual adds that defrost ends as soon as the outdoor heat exchanger reaches 13 °C. GREE also describes a maximum time for the EXTRÊME R32, without giving a figure in the manuals consulted.

    How often does the heat pump defrost?

    It depends on the frost, so on the temperature and humidity of the air, according to Natural Resources Canada. For the ORION XLTH, the service manual provides for no defrost before 17 minutes of compressor running time, then no other before 40 minutes. Natural Resources Canada mentions intervals of 30, 60 or 90 minutes for time-temperature controls.

    Why is there water or ice under the outdoor unit?

    Melted frost drains from the bottom of the unit: FUJITSU AIRSTAGE says so in its operating manual. Both manufacturers declare a base pan heater in the outdoor unit; GREE turns it on at 0 °C and below. In cold weather, the water that falls to the ground can freeze.

    Can you help the unit defrost, with hot water or a tool?

    Both manuals ask you not to speed up defrosting by any means other than those they indicate. Defrosting is automatic.

    Do you need backup heating during defrosts?

    FUJITSU AIRSTAGE writes that heating performance drops as the outdoor temperature falls, and suggests using the unit together with other heating appliances if it is not enough. Natural Resources Canada considers it important to plan for a supplementary heat source with an air-source heat pump.

    The indicator blinks although I just switched heating off. Why?

    On the ORION XLTH, if the outdoor unit is frosted when it is switched off, it defrosts first, then stops; the indicator blinks slowly in the meantime. The FUJITSU AIRSTAGE service manual describes this case on page 04-24.

    Both examples are on the AirGreen site.

    Defrost is part of a heat pump's winter. To choose a unit, talk it over with our team: bring the area to heat, your current heating system and the planned spot outside.