GREE FREEMATCH R32 and FUJITSU AIRSTAGE AQUILA XLTH, 2 zones, 18,000 BTU

Home / Comparisons / 2-zone multi-zone, 18,000 BTU

Comparison · Multi-zone · 2 zones · 18,000 BTU

GREE FREEMATCH R32 and FUJITSU AIRSTAGE AQUILA XLTH, two rooms on a single compressor

Two R-32 multi-zone systems for two rooms, both certified at 18,000 BTU/h in cooling and both listed in the ENERGY STAR directory for cold climates. With a multi-zone system, the AHRI certificate covers a set: one outdoor unit and one type of indoor unit. This page shows what each certificate covers, then puts the figures side by side.

SEER2 21 and 22HSPF2 IV 10.0 and 11.0Coldest points: −30 and −26.1 °C
GREE FREEMATCH R32, 2 zones (AirGreen image)
GREE

FREEMATCH R32 · 2 zones, 18,000 BTU

GWHD(18)ND6MO + non-ducted indoor units · AHRI 214931586

See the product page
FUJITSU AIRSTAGE AQUILA XLTH, 2 zones (AirGreen image)
FUJITSU AIRSTAGE

AQUILA XLTH · 2 zones, 18,000 BTU

AOUH18KWAH2 + non-ducted indoor units (typical: 2 × ASUH09KPAS) · AHRI 215447691

Also sold under the name GENERAL AIRSTAGE.

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 18,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point. Here, the zone is both rooms together: 18,000 BTU/h, the certified capacity of both systems at 35 °C.

How this amount is calculated
  1. Heat to deliver over the winter. A zone whose heat loss reaches 18,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 18,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

Two rooms, one compressor

Your two rooms on each system’s scale

A multi-zone system shares a single compressor between the rooms. What matters, then, is the sum of the needs and the range the compressor can cover, from minimum to maximum. Set the need of each room: the marker moves along the certified ranges of both systems.

Room 1 6,000 Room 2 5,000 BTU/hBTU/h 1 compressor 11,000 BTU/h diagram

Sum of both rooms: 11,000 BTU/h

certified range, from minimum to maximum certified rated capacity sum of your two rooms

Ranges: AHRI certificates 214931586 and 215447691, published by NEEP (minimum, rated and maximum capacity at each test temperature, 21.1 °C indoors in heating and 26.7 °C in cooling). This illustration places published values on one scale. It is not a simulation: the real need of each room comes from a load calculation, and FUJITSU AIRSTAGE states that its combination tables are not meant for final sizing.

FREEMATCH R32Wall-mounted heads in the GREE table, in BTU/h

  • 5,000
  • 7,000
  • 9,000
  • 12,000

Published combinations for the GWHD(18)ND6MO: 5 + 5, 5 + 7, 7 + 7, 9 + 9, 9 + 12 and 12 + 12. The table gives the capacity per room: 9,000 + 9,000 BTU/h for 9 + 9, 7,714 + 10,286 for 9 + 12, and 9,000 + 9,000 for 12 + 12. GREE Canada submittal sheet.

AQUILA XLTHWall-mounted heads in the FUJITSU AIRSTAGE table, in BTU/h

  • 7,000
  • 9,000
  • 12,000
  • 15,000

Published combinations for the AOUH18KWAH2: 7 + 7, 7 + 9, 7 + 12, 7 + 15, 9 + 9, 9 + 12, 9 + 15 and 12 + 12, i.e. 14,000 to 24,000 BTU/h connected. The brochure states that a total above 100% does not increase the system’s capacity. Brochure FG2057B.

What the certificate covers

One outdoor unit, three certificates

Each outdoor unit is certified three times: with non-ducted indoor units (wall-mounted, cassettes, consoles), with ducted units, then in a mixed combination. Efficiencies change from one certificate to the next. This whole page compares the two “non-ducted” certificates, those of a system with two wall-mounted heads.

Non-ducted

Two wall-mounted heads, for example. This is the comparison on this page.

SEER221
SEER222
HSPF2 IV10.0
HSPF2 IV11.0

AHRI 214931586 · AHRI 215447691

Ducted

Two ducted units.

SEER216
SEER219
HSPF2 IV8.1
HSPF2 IV10.0

AHRI 214931591 · AHRI 215447692

Mixed

One non-ducted head and one ducted unit.

SEER219
SEER220.5
HSPF2 IV9.0
HSPF2 IV10.5

AHRI 214931592 · AHRI 215447698

FREEMATCH R32 GREE · GWHD(18)ND6MOAQUILA XLTH FUJITSU AIRSTAGE · AOUH18KWAH2

Values from the six AHRI certificates published by NEEP, consulted November 9, 2026. Bars: SEER2 on a scale of 0 to 24, HSPF2 Region IV on a scale of 0 to 12. In cooling at 35 °C, the GREE “ducted” certificate shows 16,000 BTU/h; the other five, 18,000 BTU/h.

Which heads are behind “non-ducted”? NEEP does not name an indoor unit model for these certificates. The FUJITSU AIRSTAGE service manual gives the typical combination for the AOUH18KWAH2: two ASUH09KPAS wall-mounted units. The GREE Canada submittal sheet presents its combinations as AHRI certified (“with AHRI Certified Performance”) and lists the wall-mounted heads compatible with the GWHD(18)ND6MO, including the CHARMO, the CLIVIA and the Sapphire (GWH09AVDXE models, those of the AIRY).
Extreme cold

Below −15 °C: every published number, at its exact temperature

NEEP certifies both systems at −15 °C, at the same temperature. Lower, each has a single certified point, and not in the same place: −30 °C for the FREEMATCH R32, −26.1 °C for the AQUILA XLTH. Nothing is calculated between two points.

What each manufacturer publishes below −15 °C. GREE: the NEEP point at −30 °C (10,200 BTU/h, COP 1.51), a stated heating range of −30 to 24 °C and a 72 W outdoor unit base pan heater. The FREEMATCH R32 brochure, submittal sheet and service manual give no capacity table below −15 °C. FUJITSU AIRSTAGE: the NEEP point at −26.1 °C (12,060 BTU/h, COP 2.02), a heating range of −26 to 24 °C with the “no shutoff device” wording, and a base pan heater that switches on below 2 °C. The chart in brochure FG2057B is a general envelope for the series, with no value specific to the AOUH18KWAH2: it is not reproduced here.
Documented features

What each manufacturer writes

GREE FREEMATCH R32 brochure (X610068B), GREE Canada submittal sheet and service manual, FUJITSU AIRSTAGE brochure FG2057B. Each line quotes what the manufacturer writes. The GREE brochure describes the outdoor unit; several comfort features depend on the head chosen.

Extreme cold

FREEMATCH R32: stated heating from −30 to 24 °C; outdoor unit base pan heater (72 W); “intelligent” defrost.

AQUILA XLTH: heating down to −26 °C, “no shutoff device”; base pan heater below 2 °C.

Cooling in cold weather

FREEMATCH R32: stated cooling range of −30 to 48 °C.

AQUILA XLTH: from −10 to 50 °C.

Choice of heads

FREEMATCH R32: “7 indoor options”; the submittal sheet lists wall-mounted units (Charmo, Clivia, Pular, Sapphire), cassettes, a slim duct, a floor/ceiling unit and a mini console.

AQUILA XLTH: wall-mounted, Slim Duct, compact cassette, mid-static ducted and multi-position air handler.

Power supply

FREEMATCH R32: indoor units powered from the outdoor unit; automatic voltage adaptation; low-voltage start-up.

AQUILA XLTH: 208 to 230 V, single phase; 20 A breaker.

Refrigerant leak detection

FREEMATCH R32: A2L leak sensor included.

AQUILA XLTH: not stated in brochure FG2057B.

Modes and comfort

FREEMATCH R32: quiet operation and self-diagnosis on the outdoor unit side; comfort modes depend on the head.

AQUILA XLTH: Economy, Minimum Heat, Quiet, Sleep, weekly timer, automatic heating-cooling changeover.

Wi-Fi and controls

FREEMATCH R32: depends on the head chosen; the FREEMATCH brochure does not specify it.

AQUILA XLTH: “Wi-Fi Capable”, inputs-outputs and third-party control.

Restart after a power failure

FREEMATCH R32: automatic restart (GREE Canada website).

AQUILA XLTH: Restart function.

Maintenance and protection

FREEMATCH R32: self-diagnosis; coil protected against corrosion by an acrylic resin (GREE Canada website).

AQUILA XLTH: Blue Fin fins.

Sound

The sound of each one, according to its manufacturer

FUJITSU AIRSTAGE publishes six named speeds for the ASUH09KPAS head. On the GREE side, the sound depends on the head: the figures are those of the 9,000 BTU/h CHARMO, one of the heads on the AirGreen product page, published in seven levels with no speed names.

dB(A)

How to read these figures. dB(A) measures a noise level as the ear perceives it: the lower the figure, the quieter the unit. Each dot is a fan speed published by the manufacturer, from the slowest to the fastest.

Why this is not a ranking. Each manufacturer measures under its own conditions, and GREE publishes neither the distance nor the measurement conditions. A gap of a few dB(A) can come from the method as much as from the unit.

Indoor unit, in the room

Cooling, all published speeds, 9,000 BTU/h head

Outdoor unit, outside

Published values for the 18,000 BTU/h outdoor unit

Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.

Sources: GREE CHARMO R32 service manual (GWH09ATCXB-D6DNA1C, sound pressure) and GREE Multi R32 service manual (GWHD(18)ND6MO: sound pressure 54 dB(A), sound power 64 dB(A)); FUJITSU AIRSTAGE brochure FG2057B (ASUH09KPAS and AOUH18KWAH2). With the CLIVIA or the AIRY, the values for the GREE head differ.

Installation

Outside, on the wall, in the piping

Outdoor units, outlines to scale

32 3/8 × 21 11/16 in
depth 13 7/8 in · 78.3 lb

32 5/16 × 34 13/16 in
depth 12 3/8 in · 117 lb

Diagram: published width and height, at the same scale. Almost the same width; the AQUILA XLTH outdoor unit is 13 1/8 in taller.

Indoor units to scale

GREE headCHARMO 9,000: 32 7/8 × 10 53/64 × 7 7/8 in
GREE wall-mounted head from the AirGreen product page, to scale
32.88 in
ASUH09KPAS32 13/16 × 10 5/8 × 8 3/4 in
ASUH09KPAS indoor unit to scale
32.81 in

Widths to scale. GREE photo: the wall-mounted head from the AirGreen product page; dimensions of the 9,000 BTU/h CHARMO (GREE Canada service manual).

Two rooms far apart: the total piping length

60 ft

Dark: length covered by the factory charge. Light: length allowed with added refrigerant. Hatched: below the published minimum total length. GREE brochure X610068B and GREE Canada submittal sheet; FUJITSU AIRSTAGE brochure FG2057B. Each line also has its own limit: 65.6 ft to the last indoor unit for the FREEMATCH R32 (equivalent length), 16 to 82 ft per unit for the AQUILA XLTH.

Installation FREEMATCH R32 AQUILA XLTH
Maximum piping lengthTotal of both lines 131 ft 164 ftPublished minimum: 33 ft in total.
Piping length per indoor unit 65.6 ftEquivalent length to the last indoor unit (submittal sheet and service manual). 82 ft16 to 82 ft per unit.
Precharged length 33 ftThen 0.2 oz per foot. 98 ftAmount to add beyond that: not stated in the brochure.
Maximum height difference 49 ftSame value between two indoor units. 49 ft33 ft between two indoor units.
Liquid – gas diametersPer indoor unit 1/4 – 3/8 in 1/4 – 3/8 in
Outdoor unit W × H × D, weight 32 3/8 × 21 11/16 × 13 7/8 in, 78.3 lbThe GREE Canada submittal sheet shows 75 lb. 32 5/16 × 34 13/16 × 12 3/8 in, 117 lb
Indoor unit, weight9,000 BTU/h wall-mounted head 19.8 lbCHARMO GWH09ATCXB-D6DNA1C. 21 lbASUH09KPAS.
Electrical protectionPer the manufacturer MOCP 20 A (MCA 14.5 A)Brochure X610068B. The GREE Canada submittal sheet shows an MCA of 18.5 A: to be confirmed at the quote. 20 A breaker (minimum circuit ampacity 19.9 A)
Clearances around the outdoor unit 6 in from the wall; 6 to 24 in from obstacles depending on the sideFigure in the GREE Canada submittal sheet. Figure in the AOUH18KWAH2 installation manualBrochure FG2057B does not reproduce them.
Connectable capacityRated total of the two heads 10,000 to 24,000 BTU/hFrom the combination table: from 5 + 5 to 12 + 12. 14,000 to 24,000 BTU/h
Stated heating / cooling range −30 to 24 °C / −30 to 48 °C −26 to 24 °C / −10 to 50 °C
Questions

What we are asked about these two systems

Why compare complete systems rather than heads?

Because a multi-zone AHRI certificate covers a set: one outdoor unit and one type of indoor unit. The SEER2, HSPF2 and capacities on this page are those of the set “18,000 BTU/h outdoor unit and non-ducted indoor units”. The capacity of each head comes from the manufacturer’s documents and is labelled as such.

Both are 18,000 BTU/h: why are the heating figures different?

The 18,000 BTU/h is the certified capacity in cooling, at 35 °C. In heating at 8.3 °C, the FREEMATCH R32 certificate shows a rated capacity of 18,000 BTU/h and the AQUILA XLTH certificate, 22,000 BTU/h. At −15 °C, the certified maximum capacities are 13,800 and 22,000 BTU/h. These values come from the AHRI certificates published by NEEP.

What happens below −26 °C or below −30 °C?

Each manufacturer states a heating range: down to −30 °C for the FREEMATCH R32, down to −26 °C for the AQUILA XLTH, with the “no shutoff device” wording in the FUJITSU AIRSTAGE brochure. Neither gives a capacity figure beyond its last certified point. The Extreme cold section places each figure at its exact temperature.

Can two 12,000 BTU/h heads be connected to an 18,000 unit?

Both manufacturers publish the 12 + 12 combination. The GREE table then shows 9,000 BTU/h per room. The FUJITSU AIRSTAGE brochure states that a connected total above 100% does not increase the system’s capacity. Heads are chosen room by room, from a load calculation.

Which GREE heads go with the FREEMATCH R32?

The AirGreen product page lists the CHARMO, CLIVIA and AIRY wall-mounted heads. The GREE Canada submittal sheet for the GWHD(18)ND6MO also lists other types of indoor units. The sound and dimension figures on this page are those of the 9,000 BTU/h CHARMO; they change with another head.

FUJITSU AIRSTAGE and GENERAL AIRSTAGE: is there a difference?

AirGreen also offers the AQUILA XLTH under the name GENERAL AIRSTAGE. This page uses the model numbers and the AHRI certificate of the FUJITSU AIRSTAGE version (AOUH18KWAH2, AHRI 215447691).

Which one is right for me?

This page does not rank the units. It shows the certified values and what each manufacturer publishes, with the sources. The right choice depends on your two rooms, the distance between them, the outdoor location and your current heating.

Are these systems eligible for financial assistance?

Eligibility is checked on the official list of Hydro-Québec’s LogisVert program at the time of the quote, for the exact combination installed. This page gives no amounts, and programs can change.

Certified record

All AHRI and NEEP values

Certified value FREEMATCH R32 AQUILA XLTH
Cooling
Rated capacity at 35 °C 18,000 BTU/h 18,000 BTU/h
35 °C: min. / rated / max.BTU/h 7,000 / 18,000 / 19,600 6,100 / 18,000 / 21,000
SEER2 21.0 22.0
EER2 12.0Brochure X610068B shows 12.5; the certificate prevails. 13.5
Heating, same conditions
HSPF2 Region IV / V 10.0 / 8.0 11.0 / 9.3
8.3 °C: min. / rated / max.BTU/h 7,000 / 18,000 / 18,100 6,800 / 22,000 / 25,000
8.3 °C: COP min. / rated / max. 3.95 / 3.91 / 3.21 4.53 / 4.39 / 4.39
−8.3 °C: min. / rated / max.BTU/h 7,200 / 17,600 / 17,600 4,700 / 14,800 / 22,800
−8.3 °C: COP min. / rated / max. 3.25 / 2.36 / 2.36 3.28 / 3.24 / 2.58
−15 °C: min. / rated / max.BTU/h 7,200 / 13,800 / 13,800 3,900 / 22,000 / 22,000
−15 °C: COP min. / rated / max. 2.45 / 2.00 / 2.00 2.79 / 2.18 / 2.18
Coldest point of each certificate (different temperatures)
Test temperature −30 °C (−22 °F) −26.1 °C (−15 °F)
Capacity min. / max.BTU/h 7,000 / 10,200 2,500 / 12,060
COP min. / max. 1.55 / 1.51 1.83 / 2.02Values as published by NEEP: 12,060 BTU/h for 1.75 kW.
Certification
ENERGY STAR / cold climate (NEEP) Yes / Yes Yes / Yes
ENERGY STAR directory, markets listed United States, Canada United States, Canada
AHRI certificate · NEEP record 214931586 · 392112 215447691 · 455168
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 class R-32 · GWP 675 · A2L R-32 · GWP 675 · A2L

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities and COPs by point are not highlighted: the order changes depending on the point read.

Both are on the AirGreen website.

To choose for your two rooms, talk to our team: bring the room dimensions, the distance between them, the planned outdoor location and your current heating.

Sources and documents

Where each figure comes from

NEEP, record 392112 (GREE, GWHD(18)ND6MO)AHRI 214931586, non-ducted units · consulted November 9, 2026 NEEP, record 455168 (FUJITSU AIRSTAGE, AOUH18KWAH2)AHRI 215447691, non-ducted units · consulted November 9, 2026
NEEP, records 392107, 392106, 387549 and 455163“Ducted” and “mixed” certificates of both outdoor units (AHRI 214931591, 214931592, 215447692 and 215447698) · consulted November 9, 2026
ENERGY STAR directory (data.energystar.gov, dataset 83eb-xbyy)Cold climate: yes for both; markets United States and Canada · consulted November 9, 2026
GREE, FREEMATCH R32 brochure (EN)Document X610068B · capacities, piping, electrical, ranges, features GREE Canada, GWHD(18)ND6MO submittal sheetUndated · combination table, compatible heads, clearances, base pan heater · consulted November 9, 2026 GREE, Multi R32 service manual, outdoor unitsPages 2 and 3: GWHD(18)ND6MO data, ranges, sound, piping · consulted November 9, 2026 GREE, CHARMO Inverter R32 service manualPage 9: GWH09ATCXB-D6DNA1C, sound pressure, dimensions, weight · consulted November 9, 2026 FUJITSU AIRSTAGE, H Series / AQUILA XLTH brochure (FR)Part FG2057B, rev. 8/2025 · AOUH18KWAH2 data, ASUH heads, combinations, ranges
FUJITSU AIRSTAGE, service manual SR_MU008ES_02November 15, 2024, p. 9 · typical combination for the AOUH18KWAH2: ASUH09KPAS × 2 · copy hosted by a distributor
Hydro-Québec, Electricity RatesIn effect April 1, 2026 · Rate D, section 2.5 · estimated operating cost Natural Resources Canada, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C), −23.1 °C design · consulted November 9, 2026