Home / Comparisons / Guides by unit type
Low or high static ducted unit: what changes in your ducts
Every ducted unit pushes air through ducts, but not with the same force. For each series, manufacturers publish a static pressure range: the resistance that ducts, elbows, the filter and grilles can put up against the fan. This guide puts three 12,000 BTU series on the same scale and follows two examples, each with its AHRI certificate.
Slim Duct LSP 12,000 BTU
AC012DNLDCG / AC012DXSCCG · AHRI 216441744
Sold by AirGreen under the PREMIUM FJM ducted name. The certificate is that of a single-zone system; SAMSUNG’s Technical Data Book calls this cabinet “LSP Duct”.
View the product page
CENTAURI ducted 12,000 BTU
ARUH12KUAS / AOUH12KUAS1 · AHRI 215434556
Also sold under the GENERAL AIRSTAGE name. The manufacturer’s submittal calls it “Mid Static Duct”; its published range goes up to 200 Pa.
View the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. The two examples each have their own outdoor unit and certificate: the gap comes from these two combinations, not from being low or high static pressure alone. Electric baseboards serve as the point of reference.
How this amount is calculated
- Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.
Three series, three published ranges, one gauge
The documents consulted give no common line between “low” and “high” static pressure: each manufacturer names its series its own way. What can be compared is the published range. Move the needle: each arc shows where a series has a setting, and where it no longer does.
Arcs, from the inside out: SAMSUNG, GREE, FUJITSU AIRSTAGE; each white dot marks a published setting (for SAMSUNG, the upper limit of each of the 5 settings). Ranges published by each manufacturer for its 12,000 BTU cabinet. The pressure of your duct system is calculated from the duct layout: that is the installer’s job, and this guide gives no sizing advice. Conversion: 1 in. w.g. = 249 Pa.
| Fan and ducts | Slim Duct LSP | CENTAURI ducted |
|---|---|---|
| External static pressure range | 2.5 to 60 Pa (0.01 to 0.24 in. w.g.) | 30 to 200 Pa (0.12 to 0.80 in. w.g.) |
| Static pressure settings | 5 settings by option code: up to 15, 25, 40, 50 and 60 Pa0.06, 0.10, 0.16, 0.20 and 0.24 in. w.g. in the document | 18 settings, from 30 to 200 Pa in 10 Pa steps; a Standard setting; an automatic airflow adjustment setting |
| Manufacturer’s standard setting | 25 Pa (0.10 in. w.g.) | 45 Pa (0.18 in. w.g.) |
| Airflow by speed | 3 speeds: 325 / 385 / 456 CFM | 4 speeds: 300 / 347 / 400 / 500 CFM |
SAMSUNG, submittal AC012DNLDCG/AA, version 02132025A, and Technical Data Book Ver. 3.1, p. 22. FUJITSU AIRSTAGE, manual DR_AR107ES_07, pp. 2, 3 and 87. GREE (middle arc): service manual JF00305639, p. 46, 8 notches from 0 to 150 Pa.
In these three series, the slimmest cabinet has the shortest range
Three 12,000 BTU cabinets, drawn in profile at the same scale, with the maximum pressure and maximum airflow each manufacturer publishes. These are three examples, not a rule: other series have other figures.
SAMSUNG Slim Duct LSP
42.3 lb · called “LSP Duct” in the Technical Data Book
GREE ALL MATCH Slim Duct
70.6 lb · called “Slim Duct (HS)” in the submittal
FUJITSU AIRSTAGE CENTAURI ducted
66 lb · called “Mid Static Duct” in the submittal
Profiles drawn at the same scale. Bars: pressure out of 200 Pa, airflow out of 520 CFM, same scales for all three. Each airflow is the one its manufacturer publishes, by its own test method.
Below −15 °C: every published number, at its exact temperature
Static pressure says nothing about the cold: the outdoor units make the difference. At −15 °C, both examples are certified at the same point: 11,200 and 15,500 BTU/h maximum. Lower down, their published points do not fall at the same temperatures.
What each manufacturer writes, group by group
SAMSUNG: submittal AC012DNLDCG/AA and AC012DXSCCG/AA, version 02132025A. FUJITSU AIRSTAGE: submittal 12KUAS1R and manual DR_AR107ES_07.
Slim Duct LSP : 2.5 to 60 Pa, 5 settings chosen by option code; standard setting at 25 Pa.
CENTAURI ducted : 30 to 200 Pa, 18 settings, a Standard setting at 45 Pa and an automatic airflow adjustment; the submittal states automatic static pressure detection.
Slim Duct LSP : integral condensate pump, maximum 29 in lift from the bottom of the unit.
CENTAURI ducted : built-in drain pump.
Slim Duct LSP : built-in Wi-Fi as standard, SmartThings app; wired controllers and wireless remote optional.
CENTAURI ducted : optional controllers: wired, wireless with the UTY-LBTUM kit; optional Wi-Fi, AIRSTAGE Mobile app.
Slim Duct LSP : R-32 alarm output plug on the indoor unit and the outdoor unit; optional MRS-L32U leak detector.
CENTAURI ducted : built-in refrigerant leak detection sensor.
Slim Duct LSP : adapter for 24 VAC thermostats (MIM-A60UN) and external contact control interface module (MIM-B14U), optional.
CENTAURI ducted : compatible with BACnet and Modbus, with the manufacturer’s accessories.
Slim Duct LSP : base pan heater as standard; inverter-driven twin BLDC rotary compressor.
CENTAURI ducted : heated pan: not published by the manufacturer; DC twin rotary compressor.
Two hidden cabinets, measured at different airflows
SAMSUNG publishes three speeds, FUJITSU AIRSTAGE four. Both manufacturers state they measure in an anechoic chamber.
How to read these numbers. dB(A) measures a noise level the way the ear perceives it: the lower the number, the quieter the unit. Each dot is a published fan speed, from slowest to fastest.
Why this is not a ranking. The airflows are not the same: 325 to 456 CFM for the Slim Duct LSP, 300 to 500 for the CENTAURI ducted. A ducted unit is hidden: what you hear in the room also depends on the ducts and the grilles, and on the pressure the fan works against.
Indoor unit, at the cabinet
Every published speed
Outdoor unit, outside
Published values
Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.
The two examples, line by line
Indoor units, photos at the same width scale


Three-quarter photos: the dimension line gives each cabinet’s published width. Height cannot be read from these perspective photos: 198 mm and 300 mm, see the scale profiles above.
| Installation | Slim Duct LSP | CENTAURI ducted |
|---|---|---|
| Indoor unit H × W × D, weight | 198 × 900 × 440 mm, 42.3 lb7 13/16 × 35 7/16 × 17 5/16 in | 300 × 700 × 700 mm, 66 lb11 13/16 × 27 9/16 × 27 9/16 in |
| Drain pump | Yes, maximum 29 in lift | YesLift height: see the installation manual |
| Maximum piping length | 66 ft | 98 ft |
| Precharged length | 24.6 ft | 66 ft |
| Maximum height difference | 49 ft | 49 ft |
| Liquid – gas diameters | 1/4 – 3/8 in | 1/4 – 3/8 in |
| Outdoor unit W × H × D, weight | 31 1/8 × 21 5/8 × 11 3/16 in, 67.2 lb | 31 7/16 × 24 7/8 × 11 7/16 in, 84 lb |
| Electrical protectionAccording to the manufacturer; the two published measures are not the same | Maximum protection: 15 A; minimum circuit ampacity (MCA): 13.9 A | Maximum operating current: 11.7 A |
| Heated base pan | Yes, as standard | Not published by the manufacturer |
| Advertised heating / cooling range | −25 to 24 °C / −5 to 50 °CCooling down to −18 °C with a wind baffle, per the submittal | −21 to 24 °C / −21 to 50 °C |
SAMSUNG, submittal version 02132025A; ranges published in °F: −13 to 75 °F and 23 to 122 °F. FUJITSU AIRSTAGE, manual DR_AR107ES_07, pp. 2 and 102.
Your list for the visit
The choice between low and high static pressure is not made on a web page: it comes out of a calculation done in your home. These six questions give you the figures to compare with the published ranges.
Ask for the result of the calculation, in pascals or inches of water gauge, ducts, elbows, filter and grilles included. That is the figure to place on the gauge in this guide.
More grilles and more length mean more resistance. Note the number of outlets planned and the longest distance.
The cabinets in this guide are 198 mm and 300 mm high, and each manual adds its clearances. Measure the free space before the visit.
Each cabinet has several settings. Ask which one will be programmed, and keep a note of it with the unit’s documents.
The return and the filter are part of the system’s resistance, and the filter must stay accessible for maintenance.
Both examples have a built-in pump. Ask about the drain route and the height to lift; SAMSUNG publishes a maximum lift of 29 in.
What people ask about static pressure
What is external static pressure?
It is the resistance that everything outside the cabinet puts up against the fan: ducts, elbows, filter, grilles. It is measured in pascals (Pa) or inches of water gauge (in. w.g.); 1 in. w.g. equals 249 Pa.
Is there an official line between low and high static?
The documents consulted give none. Each manufacturer names its series: “Slim Duct” and “LSP Duct” at SAMSUNG, “Mid Static Duct” at FUJITSU AIRSTAGE, “Slim Duct (HS)” at GREE. This guide therefore compares the published ranges: up to 60, 200 and 150 Pa.
Is a low static ducted unit enough for my home?
It depends on the pressure calculated for your duct system. If it falls within a cabinet’s published range, that cabinet has a setting for it; otherwise it does not. The calculation is done during the estimate.
Does airflow drop when pressure rises?
For a given setting, yes: on the fan curves GREE publishes for the ALL MATCH Slim Duct, notch by notch, the available pressure drops as airflow rises. That is why each cabinet offers several settings, chosen according to the duct system.
Are the two examples real certified combinations?
Yes: AC012DNLDCG with AC012DXSCCG (AHRI 216441744) and ARUH12KUAS with AOUH12KUAS1 (AHRI 215434556), two single-zone systems. AirGreen sells the first under the PREMIUM FJM ducted name; the CENTAURI ducted is also sold under the GENERAL AIRSTAGE name.
Are they eligible for grants?
Eligibility depends on the official list in effect on the purchase date. This page promises no amount; the current list is checked when the quote is prepared.
All AHRI and NEEP values for the two examples
| Certified value | Slim Duct LSP | CENTAURI ducted |
|---|---|---|
| Cooling | ||
| 35 °C: min. / rated / max.BTU/h | 3,200 / 12,000 / 14,000 | 3,100 / 12,000 / 13,600 |
| SEER2 | 19.6 | 19.1 |
| EER2 | 11.8 | 12.7 |
| Heating, same conditions | ||
| HSPF2 Region IV / V | 9.5 / 7.6 | 10.5 / 8.9 |
| 8.3 °C: min. / rated / max.BTU/h | 3,000 / 14,000 / 17,000 | 3,400 / 16,000 / 19,400 |
| 8.3 °C: COP min. / rated / max. | 5.17 / 3.60 / 2.37 | 5.54 / 3.75 / 3.09 |
| −8.3 °C: min. / rated / max.BTU/h | 6,000 / 8,800 / 14,200 | 2,300 / 10,700 / 17,300 |
| −8.3 °C: COP min. / rated / max. | 2.75 / 2.69 / 2.46 | 4.49 / 2.93 / 2.39 |
| −15 °C: min. / rated / max.BTU/h | 4,500 / 11,200 / 11,200 | 2,100 / 15,500 / 15,500 |
| −15 °C: COP min. / rated / max. | 1.81 / 1.80 / 1.79 | 4.10 / 2.02 / 2.02 |
| Coldest point — different temperatures, not highlighted | ||
| Test temperature | −25 °C (−13 °F) | −20.6 °C (−5 °F) |
| Capacity min. / max. | 3,300 / 7,000 BTU/h | 2,000 / 14,000 BTU/h |
| COP at maximum capacity | 1.77 | 1.86 |
| Certifications and refrigerant | ||
| ENERGY STAR / cold climate (NEEP) | Yes / Yes | Yes / Yes |
| Certificate type (NEEP) | Single-zone, centrally ducted | Single-zone, compact ducted |
| AHRI certificate · NEEP record | 216441744 · 406922 | 215434556 · 388257 |
| RefrigerantGWP per the IPCC (AR4); ASHRAE 34 class | R-32 · GWP 675 · A2L | R-32 · GWP 675 · A2L |
higher marks the higher value of the same measurement, under the same conditions. It is not a recommendation. Capacities and COPs at each point are not highlighted: the order changes depending on the point.
AirGreen offers both.
To find out which pressure range your project calls for, talk to our team: bring a sketch of the rooms to serve, the free depth in the ceiling and the planned outdoor location.
Where each number comes from
Data verified on November 10, 2026. Performance: AHRI certificates and the NEEP database. Dimensions, static pressure, airflows, sound, piping and features: according to the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails.
Trademarks. SAMSUNG, FUJITSU AIRSTAGE, CENTAURI, GREE and ALL MATCH are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a dealer for these brands; this page is not produced, sponsored or endorsed by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong? Write to us: every reported figure is checked again.