KINGHOME CHARMO R32 and KINGHOME CLIVIA R32, 12,000 BTU

Comparison · Wall heat pump · 12,000 BTU

KINGHOME CHARMO R32 and KINGHOME CLIVIA R32, figure by figure

Two wall series from the same brand, in the same 12,000 BTU size. Here is what their AHRI certificates and KINGHOME's sheets publish for each one: efficiency, heating in deep cold, sound, piping and estimated electricity cost in Montréal.

KINGHOME CHARMO R32 wall heat pump, indoor unit, outdoor unit and remote KINGHOME

CHARMO R32

KW12HQ19CDI / KW12HQ19CDO · AHRI 217956851

Also sold as GREE CHARMO / VITA R32 (AHRI 215402236) and GREE LIVO R32 (AHRI 214779350): same certified AHRI and NEEP values.

See the product page
KINGHOME CLIVIA R32 wall heat pump, indoor unit, outdoor unit and remote KINGHOME

CLIVIA R32

KW12XQ25S1DI / KW12XQ25S1DO · AHRI 217933620

Same NEEP “Clivia” series as the GREE CLIVIA R32 (AHRI 216032436), with one small difference: rated COP at −8.3 °C of 2.88 here, 2.11 on the GREE certificate.

See the product page
SEER2, seasonal cooling efficiency
19/24.5
HSPF2 Region V, seasonal heating efficiency
7.3/8.0
Certified maximum capacity at −15 °C, BTU/h
9,100/11,000
Coldest test point on the certificate
−25 °C/−30 °C
CHARMO R32 KINGHOMECLIVIA R32 KINGHOME
Estimated running cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the point of reference.

Here, the gap comes from two certificate figures: HSPF2 Region V of 7.3 and 8.0 for winter, SEER2 of 19 and 24.5 for summer. The rest of the calculation is identical for both.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.

Two series, one brand

The two records, brought together line by line

On the left, the CHARMO's record; on the right, the CLIVIA's. Bring them together: the lines where KINGHOME and the AHRI certificate give the same value merge into one; the ones that differ stay apart, with both figures.

CHARMO R32CLIVIA R32
0identical lines0lines that differ
CHARMO R32CLIVIA R32same published value for both

Sources: AHRI certificates 217956851 and 217933620 read on NEEP on November 10, 2026; ENERGY STAR directory; KINGHOME spec sheets for the CHARMO R32 and the CLIVIA R32 (undated). When a KINGHOME sheet and the certificate differ, the page follows the certificate.

Deep cold

Below −15 °C: what each series publishes, point by point

Both certificates give a capacity at −15 °C. Further down, they do not stop at the same place: the CLIVIA is certified down to −30 °C, the CHARMO down to −25 °C. For the CHARMO, a GREE table for the same NEEP series adds two points outside the certificate. No figure is calculated between two points.

Why the CHARMO shows 6,500 BTU/h at −25 °C and 8,030 BTU/h at −26.1 °C. The two figures are not measured the same way. 6,500 is the maximum capacity on the AHRI certificate at −13 °F (−25 °C). 8,030 comes from GREE's “Extended Ratings” table for the LIVO R32, which has the same certified values: maximum output at −15 °F (−26.1 °C), indoor air at 21.1 °C, and GREE states that these values do not follow AHRI test conditions. The page shows both; headline comparisons follow the certificate.
Named functions

What KINGHOME writes for each series

Each card covers a function named in the KINGHOME sheet of one series or the other. When a sheet does not name it, that is stated as such: this silence does not mean the function is absent.

Wi-Fi and app
NamedCHARMO R32NamedCLIVIA R32

Both sheets name Wi-Fi and app control.

Humidity control, dehumidification 1.4 L/h
NamedCHARMO R32NamedCLIVIA R32

Same printed dehumidification rate for both: 1.4 L/h.

Self-cleaning
NamedCHARMO R32NamedCLIVIA R32

The CHARMO sheet describes a cycle using condensation, freezing and defrosting of the coil.

Automatic restart after an outage
NamedCHARMO R32NamedCLIVIA R32

The unit resumes its settings when power returns.

3D airflow, louvers
NamedCHARMO R32NamedCLIVIA R32

Vertical and horizontal air direction, named in both sheets.

Anti-corrosion protection
NamedCHARMO R32NamedCLIVIA R32

Named by KINGHOME for both series, with no treatment details.

Heated base pan, 72 W
NEEPCHARMO R32NEEPCLIVIA R32

Both NEEP records list 72 W, on below 1 °C (33.8 °F) or during defrost. The KINGHOME sheets do not name it.

Turbo mode and 7 fan speeds
NamedCHARMO R32Not named in the sheetCLIVIA R32

The CLIVIA sheet gives an airflow of 212 to 400 CFM, without a number of speeds.

Refrigerant leak detection
NamedCHARMO R32Not named in the sheetCLIVIA R32

Named in the icon row of the CHARMO sheet.

8 °C maintenance heating
Not named in the sheetCHARMO R32NamedCLIVIA R32

A mode that keeps the room around 8 °C, for example in an unoccupied cottage.

Mini ERV ventilation module, optional
Not named in the sheetCHARMO R32OptionalCLIVIA R32

The CLIVIA sheet mentions a fresh-air module offered as an option, without airflow figures.

Advertised heating range
−25 to 24 °CCHARMO R32−30 to 30 °CCLIVIA R32

Heating operating ranges printed by KINGHOME (outdoor).

Sound

What KINGHOME publishes on sound level

For the indoor unit, each sheet gives only the lowest and the highest value, without the detail per speed. For the outdoor unit, both sheets give 52 dB(A).

Indoor unit

Range printed in each series' KINGHOME sheet

dB(A)

How to read these figures. The A-weighted decibel follows the ear's sensitivity; the lower the figure, the quieter the unit. Each dot is a value printed by KINGHOME: the smallest matches the lowest fan speed, the largest the highest.

Why this is not a ranking. The sheets state neither the measuring distance nor the method. Two ranges from the same brand can be read side by side, but they say nothing about the sound in a particular room.

Measurements taken by each manufacturer with its own method, which the sheets do not detail; for indication only.

Installation

Same line lengths, not the same gas line

Both series accept 10 to 66 ft of line set, with 25 ft already charged and 40 ft of height difference. The difference is elsewhere: the gas line goes from 3/8 in on the CHARMO to 1/2 in on the CLIVIA, and the CLIVIA's outdoor unit is wider and heavier.

The indoor units, at the same scale

CHARMO R3232 7/8 × 10 53/64 × 7 7/8 in
KINGHOME CHARMO R32 indoor unit
32 7/8 in
CLIVIA R3232 61/64 × 11 17/32 × 7 7/8 in
KINGHOME CLIVIA R32 indoor unit
32 61/64 in

Widths to scale from the dimensions in the KINGHOME sheets (width × height × depth). KINGHOME photos, cut out.

Is your wall wide enough?

36 in
CHARMO R32 within the chosen width

CLIVIA R32 within the chosen width

048 in

The calculation compares the unit width with the wall width. The side clearances required by the installation manual come on top and are not counted here.

CHARMO R32, outdoor unit

CLIVIA R32, outdoor unit

Diagram to scale, front view, from the width × height dimensions in the KINGHOME sheets. Both sheets show the same outdoor unit photo; the diagram avoids suggesting that both cabinets are the same size.

LineCHARMO R32CLIVIA R32
Line set
Maximum piping length66 ftminimum 10 ft · KINGHOME sheet66 ftminimum 10 ft · KINGHOME sheet
Pre-charged length25 ft0.2 oz/ft added beyond25 ft0.2 oz/ft added beyond
Maximum height difference40 ft40 ft
Liquid – gas diameters1/4 – 3/8 in1/4 – 1/2 in
Factory R-32 refrigerant charge17.6 oz28.2 oz
Dimensions and weight
Outdoor unit W × H × D, weight28 13/16 × 21 7/8 × 12 63/64 in, 56.2 lb31 37/64 × 21 27/32 × 13 25/32 in, 67.3 lb
Indoor unit, weight19.8 lb32 7/8 × 10 53/64 × 7 7/8 in20.9 lb32 61/64 × 11 17/32 × 7 7/8 in
Clearances around the outdoor unitNot published by the manufacturer in the spec sheet; see the installation manual.Not published by the manufacturer in the spec sheet; see the installation manual.
Electrical and operation
Electrical protection208-230 V, MCA 12 A, MOCP 15 A208-230 V, MCA 10 A, MOCP 15 A
Dehumidification1.4 L/h1.4 L/h
Indoor fan airflow182 to 424 CFM212 to 400 CFM
Advertised heating / cooling range−25 to 24 °C / −18 to 48 °C−30 to 30 °C / −29 to 50 °C

Source: KINGHOME spec sheets for the CHARMO R32 (KW12HQ19CDI / KW12HQ19CDO) and the CLIVIA R32 (KW12XQ25S1DI / KW12XQ25S1DO), undated, distributed by AirGreen.

Questions

What we are asked about these two series

Where is the clearest difference in the figures?

In seasonal efficiency and in the cold. SEER2 19 for the CHARMO and 24.5 for the CLIVIA; HSPF2 Region V 7.3 and 8.0. At −15 °C, the certified maximum capacity is 9,100 and 11,000 BTU/h. The coldest test point is −25 °C for the CHARMO and −30 °C for the CLIVIA. These are values from each unit's AHRI certificate, read on NEEP.

Are both listed as cold-climate heat pumps?

Yes. The ENERGY STAR directory lists both combinations with the cold-climate mention: the CHARMO since May 28, 2026 (Canadian market), the CLIVIA since August 12, 2026 (United States and Canada). For the CHARMO, NEEP's ENERGY STAR field and the KINGHOME sheet say “no”; the page follows the directory and points this out.

What is published for the CHARMO below −25 °C?

The certificate stops at −25 °C, with 6,500 BTU/h. The KINGHOME sheet advertises a heating range down to −25 °C. A GREE table for the LIVO R32, which has the same certified values, gives 8,030 BTU/h at −26.1 °C as maximum output, outside AHRI conditions. Colder than that, none of the documents consulted gives a figure.

The KINGHOME sheet for the CLIVIA shows 7,700 BTU/h at −8.3 °C. Why does the page show 12,000?

Because AHRI certificate 217933620 gives 12,000 BTU/h (rated and maximum) at 17 °F (−8.3 °C). The same sheet prints 11,000 BTU/h at −15 °C, more than the 7,700 at −8.3 °C; this is probably a printing error. When a sheet and the certificate differ, the page follows the certificate.

Is the line set the same for both?

The lengths, yes: 10 to 66 ft, 25 ft pre-charged, 40 ft of height difference. The diameters, no: 1/4 – 3/8 in for the CHARMO, 1/4 – 1/2 in for the CLIVIA. The factory charge also goes from 17.6 to 28.2 oz of R-32. If an existing line set is to be reused, its diameter matters.

Are these series sold under other names?

The CHARMO has the same certified AHRI and NEEP values as the GREE CHARMO / VITA R32 and the GREE LIVO R32. The CLIVIA belongs to the same NEEP series as the GREE CLIVIA R32, with one small difference in rated COP at −8.3 °C. Our “platform” pages detail these names.

Where does the gap in the cost calculation come from?

Only from the two seasonal efficiencies on the certificate: HSPF2 Region V for winter, SEER2 for summer. The zone, the climate, the hours and the price per kWh are the same for both. Move the sliders: the gap follows the number of hours and the price tier.

Certified sheet

The AHRI certificate values, side by side

MeasureCHARMO R32CLIVIA R32
Seasonal efficiency
SEER21924.5
EER29.7513
HSPF2 Region IV8.59.5
HSPF2 Region V7.38.0
Rated capacity at 35 °C (95 °F), cooling12,000 BTU/h12,000 BTU/h
Certified heating
Capacity at 8.3 °C (47 °F): min. / rated / max.3,070 / 12,000 / 12,000 BTU/h3,070 / 12,000 / 14,600 BTU/h
COP at 8.3 °C: at min., rated, max.5.29 / 3.52 / 3.525.62 / 3.78 / 3.72
Capacity at −8.3 °C (17 °F): min. / rated / max.2,700 / 9,700 / 11,500 BTU/h2,700 / 12,000 / 12,000 BTU/h
COP at −8.3 °C: at min., rated, max.3.04 / 2.71 / 2.203.04 / 2.88 / 2.06
Capacity at −15 °C (5 °F): min. / rated / max.2,600 / 9,100 / 9,100 BTU/h2,600 / 11,000 / 11,000 BTU/h
COP at −15 °C: at min., rated, max.2.54 / 1.80 / 1.803.17 / 1.95 / 1.95
Coldest point on the certificate (different temperatures)
Test temperature−25 °C (−13 °F)−30 °C (−22 °F)
Capacity min. / max.1,800 / 6,500 BTU/h2,000 / 7,300 BTU/h
COP at min. / max. capacity2.03 / 1.422.79 / 1.51
Certification
AHRI certificate · NEEP record217956851 · record 369973217933620 · record 369980
ENERGY STAR, directory (cold climate)Yes, listed cold climate, Canada, May 28, 2026NEEP ENERGY STAR field: noYes, listed cold climate, United States and Canada, August 12, 2026
RefrigerantR-32, GWP 675 (IPCC AR4), class A2L (ASHRAE 34)R-32, GWP 675 (IPCC AR4), class A2L (ASHRAE 34)

“higher” marks the higher value of the same measure, under the same conditions. It is not a recommendation.

Both are on the AirGreen site.

AirGreen offers KINGHOME's CHARMO R32 and CLIVIA R32. For a quote or a question about your room, call or write to us.

Sources

Documents consulted

NEEP, record 369973 · AHRI 217956851KINGHOME CHARMO R32, KW12HQ19CDI / KW12HQ19CDO. ashp.neep.org, consulted November 10, 2026.
NEEP, record 369980 · AHRI 217933620KINGHOME CLIVIA R32, KW12XQ25S1DI / KW12XQ25S1DO. ashp.neep.org, consulted November 10, 2026.
ENERGY STAR directory, heat pumpsdata.energystar.gov, dataset 83eb-xbyy, searches 217956851 and 217933620, consulted November 10, 2026.
KINGHOME, CHARMO R32 spec sheet (FR)Undated, no document number; distributed by AirGreen. Consulted November 10, 2026.
KINGHOME, CLIVIA R32 spec sheet (FR)Undated, no document number; distributed by AirGreen. Consulted November 10, 2026.
GREE, LIVO R32 Extended RatingsGREE_LIVO_EXTENDED RATINGS_08022024, © Gree Corporation 2024, p. 9 (LIV12HP230V1R32AH / AO, heating). GREE document for the same NEEP series, same certified values. greecomfort.com, consulted November 10, 2026.
Hydro-Québec, Electricity RatesApril 1, 2026, Rate D, sec. 2.5. Subject to change.
NRCan, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C base), design temperature −23.1 °C.