LG Multi F MAX LGRED and SAMSUNG FJM Premium: distribution box or direct connections
Two R-32 outdoor units of 36,000 BTU/h for four rooms, connected in two different ways. With LG, a main line runs to a branch distribution box, which sends a short branch to each head. With SAMSUNG, four lines leave the outdoor unit directly. This page shows what each layout allows, according to the published limits, then the certified values of both systems.
Multi F MAX LGRED · 4 zones, 36,000 BTU
KUMXA361A + distribution box + non-ducted indoor units · AHRI 215402345
See the product page
FJM Premium · 4 zones, 36,000 BTU
AJ036DXS4CG/AA + non-ducted indoor units · AHRI 216372792
See the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 36,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point. Here, the zone is all four rooms together. In cooling at 35 °C, the certificates state 36,000 BTU/h for the Multi F MAX LGRED and 34,000 BTU/h for the FJM Premium: the calculation uses the common nominal size, 36,000 BTU/h.
How this amount is calculated
- Heat to deliver over the winter. A zone whose heat loss reaches 36,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 36,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
- Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.
AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.
Two ways to connect four rooms to a single outdoor unit
Set two distances: from the outdoor unit to the point where the lines split, then from there to each head. With LG, the distribution box goes at that point: one main line comes in, four branches go out. With SAMSUNG, each head has its own line, end to end. Both diagrams and both cards apply the limits published by each manufacturer.
Multi F MAX LGRED Distribution box
One main line (Ø 3/8 – 3/4 in) to the box; one branch per head.
diagramFJM Premium Direct connections
Four ports on the outdoor unit; each line runs end to end.
diagramPublished limits
Limits: LG submittal KUMXA361A (SB_Multi_F_MAX_LGRED_ODU_R32_KUMXA361A_1_26B) and SAMSUNG submittal AJ036DXS4CG/AA (version 02142025A). With LG, the length without added refrigerant splits into 49.2 ft of main line and 131.2 ft of branches; beyond that, 0.54 oz per foot of main line and 0.22 oz per foot of branch. LG also sets a maximum of 32.8 ft of height between the box and a head. This diagram applies published values to your settings; it does not replace the piping calculation done for the house.
Below −15 °C: what each manufacturer publishes, at its exact temperature
NEEP certifies both systems at −15 °C and at −25 °C: the same temperatures for both. LG also publishes a maximum capacity at −20 °C in its submittal. Nothing is calculated between two points: between two published values, the page shows the range.
What each manufacturer writes
LG submittal KUMXA361A and SAMSUNG submittal AJ036DXS4CG/AA. These documents describe the outdoor unit: several comfort features depend on the head chosen.
Multi F MAX LGRED: heating listed from −13 to 64 °F wet bulb; 40,000 BTU/h maximum at −4 °F.
FJM Premium: heating listed from −25 to 24 °C.
Multi F MAX LGRED: factory-installed base pan heater.
FJM Premium: base pan heater as standard.
Multi F MAX LGRED: from 14 °F (−10 °C); down to −4 °F with two ZLABGP04B wind baffles.
FJM Premium: from 14 to 115 °F (−10 to 46 °C).
Multi F MAX LGRED: at least one distribution box; two at most, with the ARBLN03321 Y-branch.
FJM Premium: four ports on the outdoor unit; adapters supplied.
Multi F MAX LGRED: two to five.
FJM Premium: two to four.
Multi F MAX LGRED: scroll compressor; soft start.
FJM Premium: twin rotary BLDC compressor; soft start.
Multi F MAX LGRED: “Auto restart”.
FJM Premium: automatic restart.
Multi F MAX LGRED: self-diagnosis; three-minute restart delay.
FJM Premium: output for an R-32 leak alarm, with the MIM-B14U module.
Multi F MAX LGRED: two fans; defrost and deicing.
FJM Premium: two fans.
How loud the outdoor unit is, according to its manufacturer
Outside, a single unit serves all four rooms: this is the figure that matters for the neighbours. Inside, the sound depends on each head chosen; its sheet comes with the quote.
How to read these figures. The dB(A) measures a noise level as the ear perceives it: the lower the figure, the quieter the unit. Each dot is a mode published by the manufacturer.
Why this is not a ranking. Each manufacturer measures under its own conditions. LG cites the ISO 3745 standard; the SAMSUNG submittal gives a sound pressure without naming a standard. A gap of a few dB(A) can come from the method as much as from the unit.
Outdoor unit, outside
Cooling and heating, published values for the 36,000 BTU/h unit
Measured by each manufacturer using its own method: read them separately, not as a ranking.
Sources: LG submittal KUMXA361A (sound pressure, ISO 3745) and SAMSUNG submittal AJ036DXS4CG/AA (sound pressure).
Outside, on the ground, in the piping
Outdoor units, at the same height scale
KUMXA361A
AJ036DXS4CGDepth 13 in
218.3 lb
Depth 13 in
194 lb
Top: photos from the AirGreen product cards, scaled to each unit’s published height. Bottom, diagram: published width and height, at the same scale. The two units are almost the same width; the LG unit is about 6 1/2 in taller.
What goes between the outdoor unit and the heads
- Multi F MAX LGRED
One LG distribution box (PMBD3620ZR, PMBD3630ZR, PMBD3640ZR or PMBD3641ZR): it goes between the main line and the branches. Two boxes at most, joined by the ARBLN03321 Y-branch, with at most 49.2 ft of height between them. A head can be up to 32.8 ft higher or lower than its box. - FJM Premium
Nothing in between: each line runs from the outdoor unit’s port to its head. The port adapters are supplied with the unit. The factory charge, 109.3 oz of R-32, covers up to 230 ft of piping in total.
Per each manufacturer’s submittal. The location of the box, service access and the line routing are decided during the assessment visit.
| Installation | Multi F MAX LGRED | FJM Premium |
|---|---|---|
| Connection layout | Main line, distribution box, then one branch per head | One direct line per head, four ports on the outdoor unit |
| Maximum piping lengthTotal of all lines | 475.7 ftMain line and branches together. | 230 ft |
| Main pipingUp to the distribution box | From 16.4 to 180.4 ft | Not applicable: one line per head |
| Piping per indoor unitFrom the outdoor unit to one head | From 32.8 to 229.6 ftIncluding a branch of 16.4 to 49.2 ft after the box; at most 295.3 ft for all branches together. | Up to 82 ft per line |
| Pre-charged lengthWithout adding refrigerant | 180.4 ft49.2 ft of main line and 131.2 ft of branches. | 230 ftFactory charge of 109.3 oz. |
| Refrigerant to add, beyond that | 0.54 oz per foot of main line; 0.22 oz per foot of branch | No addition published up to 230 ft, the maximum |
| Maximum height differenceOutdoor unit and indoor unit | 98.4 ft | 49 ft |
| Maximum height differenceBetween two indoor units | 49.2 ft32.8 ft between the box and a head. | 25 ft |
| Liquid – gas diameters | 3/8 – 3/4 inMain line, up to the box. | 1/4 – 3/8 in and 1/4 – 1/2 inTwo ports of each size. |
| Factory refrigerant charge | 9.262 lb of R-32 | 109.3 oz (6.83 lb) of R-32 |
| Outdoor unit W × H × D, weight | 37 13/32 × 54 1/4 × 13 in, 218.3 lb | 37 × 47 5/8 × 13 in, 194 lb |
| Electrical protectionPer the manufacturer | MOP 40 A (MCA 32.1 A) | MOP 40 A (MCA 35.9 A) |
| Number of indoor units | From 2 to 5 | From 2 to 4 |
| Heating range listed | −25 to 18 °C−13 to 64 °F wet bulb. | −25 to 24 °C−13 to 75 °F. |
Clearances around the outdoor unit: figures in the installation manuals, not reproduced on this page.
What people ask us about these two systems
What does LG’s distribution box do?
It receives the main line coming from the outdoor unit and splits it into branches, one per head. The main line can run up to 180.4 ft, and each branch is 16.4 to 49.2 ft long. The box therefore goes near the rooms it serves, and it is what allows long distances to the outdoor unit.
Why does the length per line matter so much with the FJM Premium?
Because each head has its own line to the outdoor unit: at most 82 ft per line, and at most 230 ft for all four together. Four 55 ft lines already make 220 ft. On the other hand, there is no box to install, and the factory charge covers the full allowed length.
Are both really 36,000 BTU/h?
In cooling at 35 °C, the Multi F MAX LGRED’s certificate states 36,000 BTU/h and the FJM Premium’s, 34,000 BTU/h. In heating at 8.3 °C, the certified rated capacities are 45,000 and 36,600 BTU/h. The cost calculation on this page uses the common nominal size, 36,000 BTU/h.
Will refrigerant need to be added?
With the FJM Premium, the factory charge covers up to 230 ft, the published maximum. With the Multi F MAX LGRED, the factory charge covers 49.2 ft of main line and 131.2 ft of branches; beyond that, LG calls for 0.54 oz per foot of main line and 0.22 oz per foot of branch. The diagram above does this calculation for your distances.
Can a fifth head be connected?
The LG submittal allows two to five indoor units on the KUMXA361A; the SAMSUNG submittal, two to four on the AJ036DXS4CG/AA, which has four ports. This page compares both in four zones, the configuration AirGreen sells for each.
Does the certificate change with ducted units?
Yes. A multi-zone AHRI certificate covers a set: one outdoor unit and one type of indoor unit. The values on this page are those of the “non-ducted” sets. For the FJM Premium, SAMSUNG also has a ducted certificate (216372800) and a mixed-combination certificate (216411176).
All AHRI and NEEP values
| Certified value | Multi F MAX LGRED | FJM Premium |
|---|---|---|
| Cooling | ||
| Rated capacity at 35 °C | 36,000 BTU/h | 34,000 BTU/h |
| 35 °C: min. / rated / max.BTU/h | 10,800 / 36,000 / 47,000 | 9,500 / 34,000 / 42,000 |
| SEER2 | 22.0 | 21.5 |
| EER2 | 14.5 | 12.5 |
| Heating, same conditions | ||
| HSPF2 Region IV / V | 11.0 / 9.8 | 9.5 / 7.7 |
| 8.3 °C: min. / rated / max.BTU/h | 12,420 / 45,000 / 50,000 | 7,600 / 36,600 / 54,500 |
| 8.3 °C: COP min. / rated / max. | 5.13 / 4.00 / 3.40 | 4.95 / 4.21 / 3.47 |
| −8.3 °C: min. / rated / max.BTU/h | 14,880 / 29,600 / 49,600 | 13,500 / 23,000 / 36,600 |
| −8.3 °C: COP min. / rated / max. | 3.16 / 2.38 / 2.63 | 2.83 / 2.45 / 1.83 |
| −15 °C: min. / rated / max.BTU/h | 13,392 / 41,500 / 45,000 | 13,500 / 36,600 / 36,600 |
| −15 °C: COP min. / rated / max. | 2.93 / 1.89 / 2.27 | 2.20 / 2.04 / 2.04 |
| Coldest point of both certificates (same temperature) | ||
| Test temperature | −25 °C (−13 °F) | −25 °C (−13 °F) |
| Capacity min. / max.BTU/h | 11,212 / 35,900 | 11,000 / 20,000 |
| COP min. / max. | 2.61 / 1.87 | 1.90 / 1.87 |
| Certification | ||
| ENERGY STAR / cold climate (NEEP) | Yes / Yes | Yes / Yes |
| AHRI certificate · NEEP record | 215402345 · 389367 | 216372792 · 417119 |
| Refrigerant | R-32 (GWP 675, IPCC AR4; class A2L) | R-32 (GWP 675, IPCC AR4; class A2L) |
“higher” marks the higher value of the same measure under the same conditions. It is not a recommendation. AHRI certificate values published by NEEP (non-ducted indoor units), retrieved November 10, 2026; capacities in BTU/h at 21.1 °C indoors in heating and 26.7 °C in cooling.
Both are on AirGreen’s website.
To choose for your four rooms, talk it over with our team: bring the room dimensions, the floor of each one, the planned outdoor location, the distance to the rooms and your current heating.
Where each figure comes from
Data verified November 10, 2026. Performance: AHRI certificates and the NEEP database. Dimensions, sound, piping and features: per the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails.
Trademarks. LG, Multi F, Multi F MAX, LGRED, ART COOL, SAMSUNG and FJM are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a dealer of both brands; this page is not produced, sponsored or approved by the manufacturers.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong to you? Write to us: every reported figure is checked again.