FUJITSU AIRSTAGE ORION XLTH and FUJITSU AIRSTAGE CENTAURI ACUH12KUAS, 12,000 BTU

Home / Comparisons / Guides by unit type

Guide · Wall-mounted or cassette · 12,000 BTU

Wall-mounted or ceiling cassette for an open-plan area

In an open-plan area, the real question is where the air starts from. The wall-mounted unit blows from a wall, forward. The cassette is recessed into the ceiling and blows on all four sides. One needs a clear section of wall, the other a void above the ceiling. Two 12,000 BTU FUJITSU AIRSTAGE units serve as examples, each with its own AHRI certificate.

Air outlet: 1 side or 4 sides Ceiling void: none or 245 mm HSPF2 V 10.1 and 9.2
FUJITSU AIRSTAGE ORION XLTH, 12,000 BTU wall-mounted unit (AirGreen image)
Example sold by AirGreenFUJITSU AIRSTAGE · wall-mounted

ORION XLTH · 12,000 BTU

ASUH12KZAS / AOUH12KZAH1 · AHRI 214888802

View the product page
FUJITSU AIRSTAGE CENTAURI, 12,000 BTU ceiling cassette (AirGreen image)
Example sold by AirGreenFUJITSU AIRSTAGE · cassette

CENTAURI ACUH12KUAS · 12,000 BTU

ACUH12KUAS / AOUH12KUAS1 · AHRI 215434546

View the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 12,000 BTU/h zone in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Each example has its own outdoor unit and certificate: the difference comes from these two combinations, not only from being on the wall or in the ceiling. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat needed over the winter. A zone whose heat loss reaches 12,000 BTU/h ( kW) at −23.1 °C, the Montréal design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for 24-hour heating, all winter long. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 12,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day: this is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065 ¢ per kWh up to 40 kWh per day, 11.142 ¢ above that; the average price, 9.104 ¢, is the one Hydro-Québec’s calculators use. GST and QST included. The grid access charge, the same with or without a heat pump, is not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. Your actual bill depends on the house, insulation, settings and use; this amount is not a promise.

The open area seen from above

One airflow forward, or four to the sides

A kitchen, a dining room and a living room in a single space, seen from above. Choose the unit, the shape of the room and, for the cassette, its position in the ceiling. The drawing shows the air directions described by FUJITSU AIRSTAGE; it does not measure a throw distance.

Unit
Room shape
Diagram seen from above; the furniture serves as reference points.Wall-mounted: blows forward from the wall. Cassette: outlets on four sides; three sides with the UTR-YDZB blanking plate available as an accessory.
FUJITSU AIRSTAGE ASUH12KZAS indoor unit

ORION XLTH wall-mounted unit

FUJITSU AIRSTAGE ACUH12KUAS cassette with its grille (manufacturer image)

ACUH12KUAS cassette

Does your ceiling have room?

The cassette hides in the ceiling

The body of the example cassette is 245 mm high with a 570 × 570 mm footprint, according to the submittal. Move the slider to the free height measured in your home, between the finished ceiling and the structure above: the drawing compares to scale.

The free height in your home

In the drawing, the grey band at the top is the structure above (joists or slab). The installation manual adds clearances around the body and specifies how it is suspended; the grille (UTG-CCGFGA, sold separately) fits a standard suspended grid ceiling, according to the submittal. The wall-mounted unit does not use this space.

What changes in your home

Six differences, one after another

Both heat and cool. The difference is in the path the air takes, the space they need, the condensate water and maintenance.

Extreme cold

Below −15 °C: every published figure, at its exact temperature

NEEP measures both examples at −15 °C. Lower down, the cassette is measured at −20.6 °C (−5 °F), the bottom of its stated range, and the wall-mounted unit at −26.1 °C (−15 °F). Each value is placed at its temperature, with its source; nothing is calculated between two points.

138%ORION XLTH at −15 °C, according to brochure FG8153C
124%ORION XLTH at −21 °C
102%ORION XLTH at −26 °C

Percentages of the 12,000 BTU/h rated capacity published by FUJITSU AIRSTAGE (brochure FG8153C, rev. 4/2025), outside the certificate; dark line: 100%. The cassette’s submittal does not publish an equivalent percentage.

What FUJITSU AIRSTAGE states below −15 °C. ORION XLTH wall-mounted unit: heating stated down to −26 °C, with no automatic shutdown (“no lockout”); capacity not quantified below that. ACUH12KUAS cassette: heating stated down to −21 °C (−5 °F) in the submittal; according to submittal 12KUBS1C, the system keeps running below that, with no low-temperature cut-out, but its capacity is not tested there. The same cassette is also certified with an XLTH outdoor unit (AOUH12KUAH1, another certificate); that is not the example followed here.
Documented features

What FUJITSU AIRSTAGE states about each one

Based on the wall-mounted unit’s brochure and the cassette’s submittal. When a document says nothing, the card says so.

Air direction

Wall-mounted: blows forward from the wall.

Cassette: outlets on four sides; UTR-YDZB blanking plate available as an accessory to close one outlet.

Controls and Wi-Fi

Wall-mounted: wireless remote included; built-in Wi-Fi, AIRSTAGE Mobile app.

Cassette: optional wireless remote (UTY-LNTU); optional Wi-Fi; BACnet and Modbus.

Condensate pump

Wall-mounted: not indicated in the brochure; the drain follows the piping.

Cassette: built-in drain pump, according to the submittal.

Ceiling grille

Wall-mounted: not applicable.

Cassette: UTG-CCGFGA grille sold separately; it fits a standard suspended grid ceiling.

Operating modes

Wall-mounted: Economy, Energy Saving, Powerful, Minimum Heat, Occupancy.

Cassette: Economy, Energy Saving, Powerful, Minimum Heat; weekly and 24-hour timer, sleep mode.

Fresh air and humidity

Wall-mounted: not indicated in the documents consulted.

Cassette: UTZ-VXAA fresh-air kit and high-humidity insulation kit available as accessories.

Sound

How loud each one is, according to FUJITSU AIRSTAGE

The manufacturer measures both indoor units in an anechoic chamber, at each speed. The wall-mounted unit blows from the wall; the cassette, from the ceiling, above people’s heads.

dB(A)

How to read these figures. dB(A) measures a noise level as the ear perceives it: the lower the number, the quieter the unit. Each dot is a published fan speed.

Why this is not a ranking. The cassette’s submittal states that a real installation can be louder than the laboratory measurement. Position in the room matters as much as the figure.

Indoor units, in cooling

Published sound pressure, manufacturer’s anechoic chamber

Outdoor units, outside

Published sound pressure

Measurements taken by each manufacturer using its own method; here, the same manufacturer for both. Read them as reference points, not as a ranking.

Installation

What shows in the room, at the same scale

The wall-mounted unit shows its whole front; the cassette shows only its grille in the ceiling, but its whole body is above.

Width, at the same scale

ORION XLTH wall-mounted unit979 mm wide, on the wall
FUJITSU AIRSTAGE ASUH12KZAS indoor unit
979 mm
ACUH12KUAS cassette570 × 570 mm body, in the ceiling
FUJITSU AIRSTAGE ACUH12KUAS cassette, perspective view
570 mm (body)

Width to scale: 1,000 mm = the full width of the photo area. The cassette photo is in perspective, with its grille; the dimension shows the published body footprint.

InstallationORION XLTH wall-mounted unitACUH12KUAS cassette
Indoor unit W × H × D, weight38 9/16 × 11 × 9 7/16 in, 28 lb22 7/16 × 9 5/8 × 22 7/16 in, 33 lbBody, without the grille
Maximum piping length82 ft98 ft
Precharged length49 ft66 ft
Maximum height difference66 ft49 ft
Liquid – gas diameters1/4 – 3/8 in1/4 – 3/8 in
Outdoor unit W × H × D, weight31 7/16 × 24 7/8 × 11 7/16 in, 86 lb31 7/16 × 24 7/8 × 11 7/16 in, 84 lb
Electrical protectionPer the manufacturer15 A breakerMax. 15 A breaker (MCA 14.2 A)
Dehumidification1.9 L/h1.2 L/h
Stated heating / cooling range−26 to 24 °C / −10 to 50 °C−21 to 24 °C / −21 to 50 °C

Sources: FUJITSU AIRSTAGE ORION XLTH brochure FG8153C (rev. 4/2025) and technical manual DR_AS233ES_02 for the wall-mounted unit; FUJITSU AIRSTAGE submittal 12KUBS1C (version 20260707A) for the cassette. This submittal describes the cassette with the AOUH12KUBS1 outdoor unit, whose certificate (217734521) carries the same SEER2, EER2 and HSPF2 values as that of the example sold by AirGreen (AOUH12KUAS1, 215434546). Dimensions published as height × width × depth: 245 × 570 × 570 mm for the cassette body.

Frequently asked questions

What people ask us about wall-mounted units and cassettes

Is a cassette possible in a condo?

It all depends on the ceiling. Under a concrete slab with no suspended ceiling, the 245 mm body has no room; with a deep enough suspended ceiling, recessing becomes possible. The condominium by-laws may also govern the work.

Why does the cassette have a pump?

Because condensate water forms in the ceiling, far from a drain. The example’s submittal indicates a built-in drain pump.

Is the grille included?

In the example, the UTG-CCGFGA grille is sold separately, according to the submittal. The quote should say so.

Can one of the four air outlets be closed?

Yes, with the UTR-YDZB blanking plate available as an accessory, for example when the cassette is near a wall. The “3-way” diagram above shows this case.

Which one heats down to the lowest temperature in winter?

For these two examples, the wall-mounted unit is certified down to −26.1 °C and the cassette down to −20.6 °C, each at the bottom of its stated range. These are two different combinations: the same cassette exists with an XLTH outdoor unit, under another certificate.

Is a step ladder needed for maintenance?

For the cassette, yes: the filter is behind the ceiling grille. For the wall-mounted unit, it is behind the front panel, at wall height.

Certified data sheet

All AHRI and NEEP values for both examples

Certified valueORION XLTH wall-mounted unitACUH12KUAS cassette
Cooling
Rated capacity at 35 °C12,000 BTU/h12,000 BTU/h
SEER230.523.7
EER21614.1
Heating, same conditions
HSPF2 region IV / V12.7 / 10.111.5 / 9.2
8.3 °C: min. / rated / max.BTU/h3,500 / 16,000 / 23,6003,100 / 16,000 / 19,400
8.3 °C: COP min. / rated / max.5.13 / 4.64 / 3.074.33 / 3.61 / 2.81
−8.3 °C: min. / rated / max.BTU/h2,200 / 10,000 / 18,7002,300 / 10,700 / 17,300
−8.3 °C: COP min. / rated / max.3.39 / 3.45 / 2.444.49 / 2.99 / 2.33
−15 °C: min. / rated / max.BTU/h1,950 / 16,600 / 16,6002,300 / 15,500 / 15,500
−15 °C: COP min. / rated / max.3.36 / 2.16 / 2.164.49 / 2.02 / 2.02
Coldest point — different temperatures, not highlighted
Test temperature−26.1 °C (−15 °F)−20.6 °C (−5 °F)
Capacity min. / max.1,400 / 12,200 BTU/h2,000 / 14,000 BTU/h
COP min. / max.2.74 / 1.813.91 / 1.86
Listings and refrigerant
ENERGY STAR / cold climate (NEEP)Yes / YesYes / Yes
AHRI certificate · NEEP listing214888802 · 392122215434546 · 388267
RefrigerantGWP per IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-32 · GWP 675 · A2L

higher marks the highest value of the same measurement, under the same conditions. It is not a recommendation. Capacities and COPs by point are not highlighted: the order changes depending on the point read.

AirGreen offers both.

A clear wall or a ceiling void: bring the shape of your open area, what is above the ceiling and your current heating, and talk it over with our team.

Sources and documents

Where each figure comes from

FUJITSU AIRSTAGE, submittal 12KUBS1CVersion 20260707A · ACUH12KUAS / AOUH12KUBS1 · dimensions, weight, airflow, sound, piping, electrical, ranges, pump, grille and accessories · consulted November 9, 2026
FUJITSU AIRSTAGE, ORION XLTH brochurePart FG8153C, rev. 4/2025 · ASUH12KZAS / AOUH12KZAH1: dimensions, sound, piping, features, capacity percentages in extreme cold
FUJITSU AIRSTAGE, design and technical manual DR_AS233ES_022025 · ASUH12KZAS: 14,920 BTU/h and 2.15 kW at −5 °F, at maximum capacity
FUJITSU AIRSTAGE, ACUH12KUAS product page (connect.airstagehvac.com)Photo of the cassette with its grille · consulted November 9, 2026
NEEP, listing 392122 (ORION XLTH wall-mounted unit)AHRI 214888802 · consulted November 9, 2026 NEEP, listing 388267 (ACUH12KUAS cassette)AHRI 215434546 · consulted November 9, 2026 Hydro-Québec, Electricity RatesIn effect April 1, 2026 · Rate D, section 2.5 · estimated operating cost Natural Resources Canada, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C), −23.1 °C design · consulted November 9, 2026