FUJITSU AIRSTAGE ORION XLTH and GREE EXTRÊME R32, 24,000 BTU

Home / Comparisons / 24,000 BTU wall-mounted heat pumps

Comparison · Wall-mounted heat pump · 24,000 BTU

FUJITSU AIRSTAGE ORION XLTH and GREE EXTRÊME R32 at 24,000 BTU: the circuit, the cabinet, the cold

The largest wall-mounted size in both series. At this size, three things are settled before installation: the electrical circuit to plan for, the space for the outdoor unit and the capacity that remains in a hard freeze. AHRI and NEEP values are read side by side; the rest comes from each manufacturer's documents.

SEER2 24.0 and 27.0HSPF2 IV 11.9 and 10.0Maximum at −15 °C : 25,800 and 24,000 BTU/h
208/230 VR-32Certified cooling: 22,000 BTU/h for both
FUJITSU AIRSTAGE ORION XLTH (AirGreen image)
FUJITSU AIRSTAGE

ORION XLTH 24,000 BTU

ASUH24KZAS / AOUH24KZAH1 · AHRI 215647924

Also sold as GENERAL AIRSTAGE ORION XLTH, same AHRI certificate.

See the product page
GREE EXTRÊME R32 (AirGreen image)
GREE

EXTRÊME R32 24,000 BTU

GWH24AVEXH-D6DNA1B/I / GWH24AVEXH-D6DNA1B/O · AHRI 215386339

Also sold as GREE AIRY R32: the AIRY brochure prints the same AHRI number.

See the product page
Estimated operating cost

What the electricity costs, in dollars, winter and summer

AirGreen estimate for the same 24,000 BTU/h zone in Montréal, at Hydro-Québec’s Rate D, taxes included. Both heat pumps are calculated in exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the reference point.

How this amount is calculated
  1. Heat to deliver over the winter. A zone whose heat loss reaches 24,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (base 18 °C) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours per day (“Heating” slider), the heat is reduced in the same proportion, for the heat pump as for the baseboards: this simplification does not account for recovery after a temperature setback.
  2. Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
  3. Electricity for cooling. 24,000 BTU/h ÷ SEER2 × hours per day × 60 days ÷ 1,000: the method of Hydro-Québec’s air-conditioning calculator, with the SEER2 seasonal efficiency from the AHRI certificate. The number of hours is a scenario you can set above, from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a ceiling, since a variable-speed unit slows down once the room is at temperature.
  4. Price. Hydro-Québec Rate D in effect April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond; the average price, 9.104¢, is the one Hydro-Québec’s calculators use. GST and QST included. Network access charges, the same with or without a heat pump, are not counted.

AirGreen method v1.1, November 9, 2026. An estimate is used to compare units under the same conditions. The actual bill depends on the house, the insulation, the settings and the use; this amount is not a promise.

The electrical circuit

From the panel to the indoor unit: what each manufacturer writes for 24,000 BTU

A 24,000 BTU unit needs its own 208/230 V circuit. The diagram follows the current, from the panel to the indoor unit, with the figures printed by each manufacturer. When a document is silent, the box says so.

ORION XLTH FUJITSU AIRSTAGETechnical manual DR_AS233ES_02, § 10; submittal 24KZAH1
Electrical panel208/230 V · 1 phase · 60 HzMaximum breaker20 A
Supply circuitMCA 19.4 Acable : 12 AWG
ORION XLTH outdoor unitOutdoor unitAOUH24KZAH1
Connection cable14 AWG · wiring length limit 167 ft
ORION XLTH indoor unitIndoor unitASUH24KZAS
EXTRÊME R32 GREEGREE Canada EXTRÊME R32 brochure no. 032025
Electrical panel208-230 V · 1 phase · 60 HzMaximum protection (MOP)40 A
Supply circuitMCA 25 Acable : not stated in the brochure
EXTRÊME R32 outdoor unitOutdoor unitGWH24AVEXH-D6DNA1B/O
Connection cablenot stated in the brochure
EXTRÊME R32 indoor unitIndoor unitGWH24AVEXH-D6DNA1B/I
A

How to read these figures. MCA (minimum circuit ampacity) is the minimum current the circuit wires must be able to carry. The maximum breaker, or MOP (maximum overcurrent protection), is the largest protection rating allowed. These are not consumption figures: the unit modulates and most often draws much less.

FUJITSU AIRSTAGE specifies that its wire sizes are an example based on the Japanese standard and that wires and breaker are selected according to local regulations. In Québec, a master electrician sizes the circuit from the nameplate and the Code.

From one size to the next. The ORION XLTH keeps the same circuit at 18,000 and 24,000 BTU: maximum breaker 20 A, MCA 19.4 A (15 A and 14.4 A at 12,000 BTU). The EXTRÊME R32 steps up at each size: MOP 15 A at 12,000 BTU, 25 A at 18,000 BTU, 40 A at 24,000 BTU, for an MCA of 11, 20 then 25 A. The GREE AIRY R32 brochure, for the same 24,000 BTU model numbers, prints MCA 25.5 A and maximum protection 30 A: the nameplate of the delivered unit settles it.

The outdoor unit

Two cabinets at the same scale, and the space to leave around them

Each dashed frame has the width and height published for the 24,000 BTU size, at the same scale. The AirGreen photo of the series sits inside it, for identification.

Front view, same scale

ORION XLTH outdoor unit
EXTRÊME R32 outdoor unit18,000
ORION XLTH37 × 31 × 12 5/8 inwidth × height × depth · 117 lb · same cabinet and weight as the 18,000 BTU
EXTRÊME R3239 3/8 × 29 3/8 × 16 13/16 inwidth × height × depth · 115.8 lb · dark dashed line: the 18,000 BTU cabinet (37 23/32 × 25 63/64 in, 94.8 lb)

Sources: FUJITSU AIRSTAGE submittals 24KZAH1 and 18KZAH1 (version 20250825A); GREE Canada EXTRÊME R32 brochure no. 032025.

Outdoor unit clearances

ORION XLTH

FUJITSU AIRSTAGE technical manual DR_AS233ES_02, Part 2, § 3-2 (AOUH18KZAH1 and AOUH24KZAH1), obstacles at the rear, on the sides and at the front. Top view, schematic. Where snowfall is heavy, the manual calls for a canopy and a raised stand.

EXTRÊME R32

GREE does not give clearances for the 24,000 BTU size in its brochure. They appear in the manual supplied with the outdoor unit, which the installer applies on site; no dimensioned figure is therefore reproduced here.

From minimum to maximum

Each unit's range at 24,000 BTU, at three temperatures

For each temperature, NEEP publishes the lowest certified output, the rated capacity and the maximum. At this size, the minimum matters as much as the maximum: it tells how far the unit can slow down in mild weather.

At 8.3 °C outside

ORION XLTH8,200 – 36,800 BTU/hrated 25,200 · maximum = 153 % of the size
EXTRÊME R325,800 – 32,000 BTU/hrated 24,000 · maximum = 133 % of the size

At −8.3 °C outside

ORION XLTH5,400 – 28,900 BTU/hrated 15,900 · maximum = 120 % of the size
EXTRÊME R325,800 – 24,000 BTU/hrated 23,000 · maximum = 100 % of the size

At −15 °C outside

ORION XLTH5,200 – 25,800 BTU/hrated 25,200 · maximum = 108 % of the size
EXTRÊME R323,400 – 24,000 BTU/hrated 24,000 · maximum = 100 % of the size

Same scale for every bar, from 0 to 40,000 BTU/h. Yellow tick: certified rated capacity at that temperature. “% of the size”: certified maximum capacity ÷ 24,000 BTU/h.

At 8.3 °C, the lowest certified output is 8,200 BTU/h for the ORION XLTH and 5,800 BTU/h for the EXTRÊME R32; at −15 °C, 5,200 and 3,400 BTU/h. On the maximum side, the gap narrows as it gets colder: 36,800 and 32,000 BTU/h at 8.3 °C, 25,800 and 24,000 BTU/h at −15 °C.

Extreme cold

Below −15 °C: every published figure, at its exact temperature

NEEP certifies both units down to −15 °C, at the same temperatures. Below that, each figure is placed at its exact temperature, with its source. Nothing is calculated between two points.

108 %at −15 °C
95 %at −21 °C
80 %at −26 °C

ORION XLTH: maximum heating capacity as a percentage of the 24,000 BTU/h nominal capacity, with 21 °C indoors, per FUJITSU AIRSTAGE brochure FG8153C (revision 4/2025). Vertical line: 100%. For the 18,000 BTU size, the same brochure gives 141, 127 and 106%.

Same outdoor unit, same figures in extreme cold. The technical manual gives the 24,000 BTU ORION XLTH exactly the maximum capacities of the 18,000 BTU at −20.6 °C (22,860 BTU/h) and at −26.1 °C (19,110 BTU/h). The two sizes share the outdoor cabinet, its weight and its electrical circuit; the gap between them plays out above −15 °C.
What GREE publishes below −15 °C for this size. The NEEP point at −30 °C (17,000 BTU/h, COP 1.62) and a stated heating range of −30 to 30 °C. GREE Canada brochure no. 032025 prints no low-temperature capacity. Between −15 and −30 °C, the table therefore gives the bracket between the two certified points, each with its temperature, with no calculated value.
Documented features

What each document names

FUJITSU AIRSTAGE brochure FG8153C and submittal 24KZAH1; GREE Canada EXTRÊME R32 brochure no. 032025; NEEP records for the base pan heater. Each line quotes what the document says.

Extreme cold

ORION XLTH: heating stated down to −26 °C, “no lockout”; the submittal specifies that the unit keeps operating below that range, with no low temperature cut out, and that capacity is not tested there. Heated outdoor base pan (150 W per NEEP), automatic defrost.

EXTRÊME R32: heating stated down to −30 °C. Outdoor base pan heater: 160 W, on below 1 °C or during defrost (NEEP record).

Cooling in cold weather

ORION XLTH: down to −10 °C outside.

EXTRÊME R32: down to −29 °C outside.

Modes

ORION XLTH: Powerful, Economy, Energy Saving, Minimum Heat, Occupancy; low-noise mode for the outdoor unit.

EXTRÊME R32: “G-AI Learning”.

Controls

ORION XLTH: built-in Wi-Fi, AIRSTAGE Mobile app; backlit remote included; BACnet and Modbus; optional wall controllers and 24 V thermostat interface.

EXTRÊME R32: Wi-Fi (app not named); YBE1FB1F remote; XE-71 wired thermostat among the accessories.

Restart and power

ORION XLTH: automatic restart after a power failure.

EXTRÊME R32: “low-voltage start-up”.

Maintenance and compressor

ORION XLTH: washable filter, ProCore coil; inverter compressor.

EXTRÊME R32: washable filters; “G10 Inverter”, two-stage variable-speed compressor.

The features described are those of the series; neither brochure distinguishes sizes on these points. The English version of the GREE brochure refers to “G20 Inverter”; the French version says “G10”. This page quotes the French version, without settling the matter.

Sound

The sound of each at 24,000 BTU, according to its manufacturer

FUJITSU AIRSTAGE publishes six named speeds for the ORION XLTH at 24,000 BTU. GREE publishes seven levels for the EXTRÊME R32, with no speed names. Both give a sound pressure in dB(A).

dB(A)

How to read these figures. dB(A) measures a noise level as the ear perceives it: the lower the figure, the quieter the unit. Each dot is a fan speed published by the manufacturer, from the slowest to the fastest.

Why this is not a ranking. FUJITSU AIRSTAGE measures in its own anechoic chamber. GREE publishes neither the distance nor the measurement conditions. A gap of a few dB(A) can come from the method as much as from the unit.

Indoor unit, in the room

Cooling, every published value

Outdoor unit, outside

Highest published value

Measurements taken by each manufacturer using its own method: read them separately, not as a ranking.

Sources: FUJITSU AIRSTAGE submittal 24KZAH1 (version 20250825A); GREE Canada EXTRÊME R32 brochure no. 032025. At 18,000 BTU, the same documents give 30 to 44 dB(A) indoors for the ORION XLTH and 35 to 49 dB(A) for the EXTRÊME R32; outdoors, 47 and 59 dB(A). The GREE AIRY R32 brochure, for the same model numbers, prints other values (57, 53 and 50 dB(A) indoors, 72 dB(A) outdoors) without stating the method; this page follows the EXTRÊME brochure.

Installation

Piping, weights and ranges at 24,000 BTU

The installation values published by each manufacturer for this size. The installation manual of the delivered unit prevails.

Installation, 24,000 BTUORION XLTHEXTRÊME R32
Maximum piping length164 ft131.2 ft
Precharged length66 ftadd 0.43 oz/ft beyond24.6 ftGREE AIRY R32 brochure (same model numbers, same AHRI number): add 0.4 oz/ft beyond; the EXTRÊME brochure does not give this length.
Maximum height difference98 ft82 ft
Liquid – gas diameters3/8 – 5/8 in1/4 – 5/8 in
Outdoor unit W × H × D, weight37 × 31 × 12 5/8 in, 117 lb39 3/8 × 29 3/8 × 16 13/16 in, 115.8 lb
Indoor unit, weight45 1/4 × 13 3/8 × 11 in, 36 lb43 45/64 × 13 21/32 × 10 1/8 in, 39.7 lb
Electrical protectionPer the manufacturer; 208/230 VMaximum breaker 20 A (MCA 19.4 A)MOP 40 A (MCA 25 A)
Dehumidification4.1 L/h3.5 L/h
Rated heating / cooling range−26 to 24 °C / −10 to 50 °C−30 to 30 °C / −29 to 50 °C
Refrigerant: factory chargeR-32, 1,700 gR-32, 1,600 g

ORION XLTH: FUJITSU AIRSTAGE submittal 24KZAH1 (version 20250825A) and technical manual DR_AS233ES_02, § 10. EXTRÊME R32: GREE Canada brochure no. 032025.

Frequently asked questions

What people ask about these two wall units at 24,000 BTU

What electrical circuit does each need at 24,000 BTU?

For the ORION XLTH, FUJITSU AIRSTAGE lists a maximum breaker of 20 A and an MCA of 19.4 A. For the EXTRÊME R32, GREE lists a maximum protection (MOP) of 40 A and an MCA of 25 A. Both run on 208/230 V. A master electrician sizes the circuit from the nameplate and the Code.

Why is the certified cooling capacity 22,000 BTU/h?

Both AHRI certificates list 22,000 BTU/h at 35 °C for these units sold as 24,000 BTU. The certified record on this page shows that value. The cost estimate starts from a 24,000 BTU/h zone, identical for both.

Which one heats more at −15 °C at 24,000 BTU?

Per NEEP, 25,800 BTU/h at maximum for the ORION XLTH and 24,000 BTU/h for the EXTRÊME R32. It is the lowest temperature at which both are measured under the same conditions.

Does the 24,000 BTU ORION XLTH have the same outdoor unit as the 18,000 BTU?

The submittals give the AOUH18KZAH1 and AOUH24KZAH1 units the same dimensions (37 × 31 × 12 5/8 in), the same weight (117 lb), the same R-32 charge and the same electrical circuit. They are two distinct model numbers and two distinct AHRI certificates.

Why is the EXTRÊME R32 measured at −30 °C and the ORION XLTH at −26.1 °C?

Each manufacturer has its unit measured at the bottom of its stated range: −30 °C for GREE, −15 °F (−26.1 °C) for FUJITSU AIRSTAGE. The 17,000 BTU/h of the EXTRÊME R32 at −30 °C and the 19,110 BTU/h of the ORION XLTH at −26.1 °C are therefore not directly comparable.

Are they eligible for grants?

Eligibility depends on the official list in force on the purchase date. This page promises no amount; the current list is checked when the quote is prepared.

Certified record

Every AHRI and NEEP value

Certified valueORION XLTHEXTRÊME R32
Cooling
Rated capacity at 35 °C22,000 BTU/h22,000 BTU/h
SEER224.027.0
EER212.5013.95
Heating, same conditions
HSPF2 Region IV11.910.0
HSPF2 Region V9.48.5
8.3 °C: min. / rated / max.BTU/h8,200 / 25,200 / 36,8005,800 / 24,000 / 32,000
8.3 °C: COP min. / rated / max.5.59 / 3.97 / 3.044.05 / 3.91 / 3.20
−8.3 °C: min. / rated / max.BTU/h5,400 / 15,900 / 28,9005,800 / 23,000 / 24,000
−8.3 °C: COP min. / rated / max.4.06 / 3.11 / 2.333.21 / 2.94 / 1.94
−15 °C: min. / rated / max.BTU/h5,200 / 25,200 / 25,8003,400 / 24,000 / 24,000
−15 °C: COP min. / rated / max.3.91 / 2.14 / 2.062.49 / 1.80 / 1.80
Coldest point — different temperatures, not highlighted
Test temperature−26.1 °C (−15 °F)−30 °C (−22 °F)
Capacity min. / max.3,540 / 19,110 BTU/h1,720 / 17,000 BTU/h
COP at maximum capacity1.651.62
Listings and refrigerant
ENERGY STAR / cold climate (NEEP)Yes / YesYes / Yes
ENERGY STAR directory, markets listedUnited States, CanadaUnited States, Canada
AHRI certificate · NEEP record215647924 · 385841215386339 · 389442
RefrigerantGWP per the IPCC (AR4); ASHRAE 34 classR-32 · GWP 675 · A2LR-32 · GWP 675 · A2L

higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities and COPs by point are not highlighted: the order changes depending on the point read. Both certificates list 22,000 BTU/h of cooling at 35 °C for these units sold as 24,000 BTU.

Both are on the AirGreen website.

To choose for your room, talk to our team: bring the room dimensions, the planned outdoor location and your current heating.

Sources and documents

Where each figure comes from

NEEP, record 385841 (ORION XLTH 24,000 BTU)AHRI 215647924 · consulted November 9, 2026 NEEP, record 389442 (“Airy” series, 24,000 BTU)AHRI 215386339 · consulted November 9, 2026
ENERGY STAR directory (data.energystar.gov, dataset 83eb-xbyy)Cold climate: yes for both; markets: United States and Canada · consulted November 9, 2026
FUJITSU AIRSTAGE, technical manual DR_AS233ES_02January 17, 2025 · § 5-2, ASUH24KZAS heating capacity; Part 2, § 3-2, clearances; § 10, electrical characteristics and wiring · consulted November 9, 2026 FUJITSU AIRSTAGE, submittal 24KZAH1Version 20250825A · piping, electrical, sound, dimensions, operation below the published range · consulted November 9, 2026 FUJITSU AIRSTAGE, submittal 18KZAH1Version 20250825A · 18,000 BTU values · consulted November 9, 2026 FUJITSU AIRSTAGE, ORION XLTH brochure (EN)Part FG8153C, rev. 4/2025; French FG8153D · % of nominal capacity at −15, −21 and −26 °C, features · consulted November 9, 2026 GREE Canada, EXTRÊME R32 brochure (FR)Document no. 032025 · electrical, dimensions, sound, piping, ranges, features · consulted November 9, 2026 GREE, AIRY R32 brochure (EN)Undated · precharged length, additional refrigerant, MCA and protection (same model numbers, AHRI 215386339) · consulted November 9, 2026 Hydro-Québec, Electricity RatesIn effect April 1, 2026 · Rate D, article 2.5 · estimated operating cost Natural Resources Canada, HOT2000 climate mapMontréal Intl station: 4,167 degree-days (18 °C), −23.1 °C design temperature · consulted November 9, 2026