vänEE V160H75RT, BROAN-NUTONE V160H75RS and VENMAR A160H75RT, HRV air exchangers

Home / Comparisons / Air exchangers

Comparison · HRV air exchanger · 150 CFM

vänEE V160H75RT: its other names, and efficiency figures that differ by source

The vänEE V160H75RT, the BROAN-NUTONE V160H75RS and the VENMAR A160H75RT share the same airflows, the same power supply and the same weight. The HVI directory lists the V160H75RT and the V160H75RS with identical values. The A160H75RT is not listed, and its spec sheet publishes different efficiency figures. This page shows every figure with its source.

Airflow at 0.4 in. w.c.: 150 CFM for all three At −25 °C, HVI directory: 67% A160H75RT spec sheet at −25 °C: 65%
vänEE V160H75RT (AirGreen image)
vänEE

V160H75RT

Top ports · HVI 2505306

Spec sheet 1109196G (V160H75RT and V160H75RS)

See the product page
VENMAR AVS A160H75RT (AirGreen image)
VENMAR

AVS A160H75RT

Top ports · not listed in the HVI directory

Spec sheet VB0331, performance sheet 1109188C

See the product page
Estimated operating cost

What the fans cost, in dollars per year

An air exchanger does not heat or cool: it renews the air, often day and night. What it costs to run depends on the power of its two fans. We start from the watts published at the same test airflow, at Hydro-Québec Rate D, taxes included.

Test airflow, at 0 °C
Price per kWh (Rate D, April 1, 2026)
How this amount is calculated
  1. Power: the watts published at the chosen test airflow. At 64 CFM: 28 W for the V160H75RT and the V160H75RS (HVI directory), 36 W for the A160H75RT (Venmar spec sheet VB0331, not listed in the HVI directory). At 129 CFM: 100 W for both sources.
  2. Energy: watts × hours per day × 365 days ÷ 1,000 = kWh per year.
  3. Price: Hydro-Québec Rate D in effect April 1, 2026 (7.065¢ up to 40 kWh a day, 11.142¢ above, 9.104¢ on average), multiplied by 1.14975 for GST and QST. The system access charge is not counted.

This calculation counts only the electricity used by the fans, measured at 0 °C. It does not count heating the fresh air that enters the house, nor the higher power draw during defrost in extreme cold (43 W at the HVI test point at −25 °C). Actual airflow depends on settings and ductwork.

AirGreen method v1.1, ventilation, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the settings and how the unit is used; this amount is not a promise.

Three names, one core

V, B or A: the letter changes, and so does the HVI listing

All three are HRVs with Virtuo technology; their spec sheets carry the names Broan-NuTone LLC and Venmar Ventilation ULC. The HVI directory publishes the same values for the V160H75RT and the V160H75RS. It has no listing for the A160H75RT; its figures come only from the Venmar spec sheet.

77% SRE at 0 °C · HVI stale air, outgoing fresh air, incoming
vänEE V160H75RT, top portsV160H75RT · vänEE
BROAN-NUTONE V160H75RS, side portsV160H75RS · BROAN-NUTONE
VENMAR AVS A160H75RT, top portsA160H75RT · VENMAR

Diagram of the cross-flow core, manufacturer photos. The arrows illustrate the two airstreams; they do not represent a measured airflow.

HVI directory: V160H75RT and V160H75RS

Listings 2505306 (vänEE) and 2505433 (Broan), data as of November 4, 2026

77%SRE
64CFM
28 Wpower
HVI certified

Same figures for both names, and for the V160H75RT also listed under the Venmar brand (2505350).

A160H75RT: Venmar spec sheet only

Spec sheet VB0331, performance sheet 1109188C, undated

75%SRE
64CFM
36 Wpower
Gap with the HVI directory

At the same test airflow as the HVI directory, the spec sheet publishes 2 SRE points less and 8 W more. The A160H75RT is not listed in the directory; we cannot say which of the two describes the unit sold under that name.

Extreme cold

At −25 °C, four sources, two figures

Sensible recovery efficiency (SRE) tells you what share of the heat in the outgoing air goes back into the fresh air. It is measured under CSA C439 at 0 °C and −25 °C. Each source below publishes a value at both temperatures; the yellow line marks the HVI directory figure.

Out of 100 units of heat leaving the house

Defrost, per both spec sheets: recirculation (Homeshield), from −5 °C. The unit closes the fresh-air intake and circulates house air through the core to clear the frost, then resumes the exchange. At the HVI test point at −25 °C, power rises to 43 W for 66 CFM, compared with 28 W for 64 CFM at 0 °C.

Sources: HVI directory, section III (publication 911, data as of November 4, 2026); spec sheet 1109196G; spec sheet VB0331 / 1109188C; broan-nutone.com V160H75RT product page consulted November 9, 2026. Adjusted SRE and apparent sensible effectiveness are in the full table below.

Airflow

Three names, a single airflow curve

The more the ducts resist, the less air the unit moves. External static pressure, in inches of water column (in. w.c.), measures that resistance. The HVI directory and the Venmar spec sheet publish exactly the same ten points for all three names, from 0.1 to 1.0 in. w.c.

V160H75RT HVI 2505306V160H75RS HVI 2505433A160H75RT spec sheet VB0331The three curves overlap.
Features

What both spec sheets name, feature by feature

Spec sheets 1109196G (vänEE V160H75RT and BROAN-NUTONE V160H75RS) and VB0331 (VENMAR A160H75RT) name the same features. Only the location of the ports changes from one model to the next.

Automatic airflow balancing (Virtuo Air)

The airflow is calibrated and balanced by the unit, then maintained, instead of manual adjustment of balancing dampers.

1109196GVB0331
Electronic airflow measurement, LCD screen

Airflow is set to the nearest CFM on the unit’s screen, from 35 to 160 CFM per the spec sheets.

1109196GVB0331
PMSM ECM fan motors

Electronically commutated permanent-magnet synchronous motors, per both spec sheets.

1109196GVB0331
Motorized dampers

The spec sheets state that no backdraft dampers need to be added in the ducts.

1109196GVB0331
Snap-in drain

Drain fitting that snaps in by hand, hose supplied per the spec sheets.

1109196GVB0331
Recirculation defrost (Homeshield)

From −5 °C, house air circulates through the core to defrost it.

1109196GVB0331
Recirculation mode from the wall control

The unit circulates house air with no exchange with the outdoors, at the occupant’s choice.

1109196GVB0331
Washable MERV 8 filter

MERV 13 and HEPA available as options, per both spec sheets.

1109196GVB0331
Built-in diagnostic tool

Named in both spec sheets for maintenance and troubleshooting.

1109196GVB0331
Installation

Top or side: the mechanical room decides

The V160H75RT and the A160H75RT have their 6 in. round ports on top. The V160H75RS has them on the side, which changes its dimensions: wider, less tall.

vänEE V160H75RT21 × 16.13 × 21.5 in. (W × D × H)
vänEE V160H75RT
BROAN-NUTONE V160H75RS23.38 × 16.13 × 19.13 in. (W × D × H)
BROAN-NUTONE V160H75RS
VENMAR A160H75RT21 × 16.3 × 21.5 in. (W × D × H)
VENMAR A160H75RT

Left, the manufacturer photo (in perspective). Right, the outline of the front, width × height, drawn to the same scale for all three (diagram). Dimensions per the spec sheets; the broan-nutone.com product page for the V160H75RT gives 21.5 × 21 × 16.3.

Top ports V160H75RT, A160H75RT

diagram · 6 in. round ports on top

Side ports V160H75RS

diagram · 6 in. round ports on the side
Installation, per the manufacturerSpec sheet 1109196G · V160H75RT / V160H75RSSpec sheet VB0331 · A160H75RT
Duct portsround6 in., top (RT) or side (RS)6 in., top (A160H75RS: side)
Dimensions W × D × HRT: 21 × 16.13 × 21.5 in.RS: 23.38 × 16.13 × 19.13 in.21 × 16.3 × 21.5 in.
Unit weight35 lb35 lb
Power supply120 V, 60 Hz, 2.4 A, 163 W120 V, 60 Hz, 2.4 A, 163 W
DrainYes, snap-in drain, hose suppliedYes, snap-in drain, hose supplied
Motorized dampersYes, no backdraft dampers to addYes, no backdraft dampers to add
Adjustable airflow range35 to 160 CFM35 to 160 CFM
Factory filterWashable MERV 8MERV 13 and HEPA optionalWashable MERV 8MERV 13 and HEPA optional
CorePolypropylene, cross-flowPolypropylene, cross-flow
CabinetGalvanized steelGalvanized steel
Questions

What people ask about these three names

Do the V160H75RT, V160H75RS and A160H75RT have the same values?

The published airflows, power supply, weight and features are the same. The HVI directory lists the V160H75RT and the V160H75RS with identical values at 0 °C and −25 °C. The A160H75RT is not listed, and its Venmar spec sheet publishes 75% and 36 W at 0 °C, then 65% at −25 °C, instead of 77%, 28 W and 67%.

Which figure to go by at −25 °C, 67% or 65%?

For the V160H75RT and the V160H75RS, the HVI directory publishes 67% at 66 CFM and 43 W; that is the certified value, and this page follows it. The 65% comes from the Venmar spec sheet for the A160H75RT and also appears on the V160H75RT product page on broan-nutone.com. Since the A160H75RT is not listed in the directory, we show its figure as the spec sheet gives it, without correcting it.

Why a V, a B or an A in front of the same number?

The prefix matches the brand the model is sold under: V for vänEE (the HVI directory also lists a V160H75RT under the Venmar brand), B and V for Broan, A for Venmar’s AVS line. The last character gives the ports: T for top, S for side. This page compares the values each source publishes, name by name.

Are they still made?

The broan-nutone.com product page for the V160H75RT showed “Product Discontinued” on November 9, 2026; the A160H75RT page showed it on November 5. The HVI directory lists a V160H80RT with the same values. AirGreen confirms the available model at quote time.

Are they ENERGY STAR certified?

Both spec sheets say so, for Canada only. The broan-nutone.com product pages say “No” (“ENERGY STAR certified: No”). The sources contradict each other; the Natural Resources Canada ENERGY STAR list is the authority, and we do not settle it here.

What about noise and warranty?

The spec sheets consulted publish no sound level for these models, and this page does not compare warranties. The warranty documents for the unit chosen come with the quote.

All values

Every test point, with its source

Left column: the HVI directory for the V160H75RT and the V160H75RS, identical to spec sheet 1109196G. Right column: Venmar spec sheet VB0331 for the A160H75RT, which is not listed in the directory.

MeasurementV160H75RT · V160H75RSA160H75RT
Recovery at 0 °C, low test airflow
Test airflownet fresh air64 CFM (30 L/s)HVI64 CFM (30 L/s)spec sheet VB0331
Sensible recovery efficiency (SRE)77%HVI75%spec sheet VB0331
Adjusted sensible recovery efficiency (ASRE)80%HVI78%spec sheet VB0331
Power draw28 WHVI36 Wspec sheet VB0331
Recovery at 0 °C, high test airflow
Test airflownet fresh air129 CFM (61 L/s)HVI129 CFM (61 L/s)spec sheet VB0331
Sensible recovery efficiency (SRE)66%HVI66%spec sheet VB0331
Adjusted sensible recovery efficiency (ASRE)71%HVI71%spec sheet VB0331
Power draw100 WHVI100 Wspec sheet VB0331
Recovery at −25 °C
Test airflownet fresh air66 CFM (31 L/s)HVI64 CFM (30 L/s)spec sheet VB0331
Sensible recovery efficiency (SRE)67%HVI65%spec sheet VB0331
Adjusted sensible recovery efficiency (ASRE)69%HVI67%spec sheet VB0331
Power draw43 WHVI41 Wspec sheet VB0331
Net airflow delivered
Airflow at 0.1 / 0.4 / 1.0 in. w.c.163 / 150 / 114 CFMHVI163 / 150 / 114 CFMspec sheet VB0331
Certification
HVI directory, section IIIYes, listings 2505306 (RT) and 2505433 (RS)Not listed as of November 4, 2026
ENERGY STARSpec sheet: yes, Canada onlybroan-nutone.com page: noSpec sheet: yes, Canada onlybroan-nutone.com page: no

“Higher” marks the higher value of the same measurement, under the same conditions. It is not a recommendation. No row is marked here: the two columns do not come from the same type of source (HVI directory on one side, manufacturer spec sheet on the other). Apparent sensible effectiveness, published in both spec sheets but not HVI certified according to them, is 81% (1109196G) and 80% (VB0331) at the low airflow at 0 °C.

All three are on the AirGreen website.

Top or side: the space in the mechanical room often decides. Talk to our team before choosing.

Sources and documents

Where every figure comes from

HVI, Certified Products Directory, section IIIPublication 911, data as of November 4, 2026 · listings 2505306, 2505350, 2505433 · consulted November 9, 2026
vänEE / BROAN-NUTONE V160H75RT and V160H75RS spec sheetBroan-NuTone LLC / Venmar Ventilation ULC, performance sheet 1109196G, undated · consulted November 5, 2026
VENMAR A160H75RT and A160H75RS spec sheetVenmar Ventilation ULC, code VB0331, performance sheet 1109188C, undated · consulted November 5, 2026
V160H75RT product page, broan-nutone.com“Product Discontinued”, HVI: yes, ENERGY STAR: no, 77% and 65% at 64 CFM · consulted November 9, 2026
V160H75RS and A160H75RT product pages, broan-nutone.comConsulted November 5, 2026
Hydro-Québec, Electricity RatesIn effect April 1, 2026 · Rate D, section 2.5 · fan cost