GREE UNIX R32 and GREE FLEXX ULTRA R32: two certificates, line by line
Two 3-ton GREE central heat pumps on R-32, each with its outdoor unit and its air handler, ENERGY STAR cold climate certified and offered by AirGreen. They carry different model numbers and different AHRI certificates. Their certified values track each other very closely, and their documents publish the same dimensions. This page puts both certificates side by side and shows where they part.
FLEXX ULTRA R32 · 3 tons
FXU36HP230V1R32AH / FXU36HP230V1R32AO · AHRI 215213330
View the product pageWhat the electricity costs, in dollars, winter and summer
AirGreen estimate for the same 34,000 BTU/h house, the certified rated capacity of both heat pumps, in Montréal, at Hydro-Québec Rate D, taxes included. Both heat pumps are calculated exactly the same way, with the same method as on all our comparison pages; only their certified efficiencies change. Electric baseboards serve as the point of reference. Here, both certificates give the same HSPF2 in Region V (7.6) and the same capacity (34,000 BTU/h): estimated heating costs the same amount, and the small summer difference comes from SEER2 (18.2 and 18.0).
How this amount is calculated
- Heat needed over the winter. A house whose heat loss reaches 34,000 BTU/h ( kW) at −23.1 °C, Montréal’s design temperature: kW × 24 h × 4,167 degree-days ÷ (18 − (−23.1)) = kWh of heat for round-the-clock heating, all winter. Heating degree-days (18 °C base) and design temperature: Natural Resources Canada, HOT2000 climate data, Montréal Intl station. With fewer hours a day (the “Heating” slider), the heat is reduced in the same proportion, for the heat pump and the baseboards alike: this is a simplification that ignores the recovery after a temperature setback.
- Electricity for heating. Heat pump: heat × 3.412 ÷ HSPF2 Region V, the AHRI certificate value published by NEEP. Region V is the coldest in the standard, and its calculation includes the electric backup expected when the heat pump is no longer enough. Electric baseboards: 1 kWh of electricity for 1 kWh of heat.
- Electricity for cooling. 34,000 BTU/h ÷ SEER2 × hours a day × 60 days ÷ 1,000: the method of Hydro-Québec’s air conditioning calculator, with the seasonal SEER2 efficiency from the AHRI certificate. The number of hours is a scenario, adjustable above from 1 to 24 h. At 24 h, the calculation assumes rated capacity all day long: that is a maximum, since a variable-speed unit slows down once the room is at the right temperature.
- Price. Hydro-Québec Rate D in effect on April 1, 2026: 7.065¢ per kWh up to 40 kWh a day, 11.142¢ beyond that; the average price, 9.104¢, is the one offered by Hydro-Québec’s calculators. GST and QST included. The system access charge, the same with or without a heat pump, is not counted.
AirGreen method v1.1, November 9, 2026. An estimate is for comparing units under the same conditions. The actual bill depends on the house, the insulation, the settings and how it is used; this amount is not a promise.
Seventeen certified lines, three differences
Here is what the NEEP directory publishes for each AHRI certificate, line by line. Fourteen lines carry the same values. Three differ, and they are highlighted in yellow.
Source: NEEP records 378411 (AHRI 217120760) and 392095 (AHRI 215213330), read on November 9, 2026. The power inputs behind these differences also differ: 3.18 and 3.15 kW at maximum at 8.3 °C, 3.82 and 3.87 kW at maximum at −8.3 °C. In the UNIX R32 certificate, the rated value at −8.3 °C (32,600) is higher than the maximum value (32,200): the page reproduces both as they are listed.
The outdoor unit, to scale, in your yard
The documents for both series publish the same outdoor cabinet, 39 in wide by 14 9/16 in deep, and the same clearance table. The fan blows toward the front. Pick the situation closest to yours, then set the space you have.
Outdoor unit GUD36W2/NhE-D(U): dimensions from GREE Canada brochure 062025; clearances from the GREE data sheet for this model (greehvac.ca), page 6.
Outdoor unit FXU36HP230V1R32AO: GREE submittal dated January 27, 2026, page 6, and the outdoor unit installation manual, section 3.1.3.
Scale drawing, top and side views; this is not a photo. The distances are the minimums from the “Minimum clearance” table in both documents, for a single unit. Both data sheets also ask for the unit to sit 2 in above the expected snow line (the snow depth in the drawing is an example), and the installation manual asks for a spot where the noise and the discharged air do not disturb the neighbours. Municipal by-laws and the building code apply on top of these minimums.
Below −15 °C: what each document publishes
Both certificates give the same points: 34,000 BTU/h at maximum at −15 °C and 20,400 BTU/h at −30 °C. In between, GREE publishes a capacity table for the FLEXX ULTRA R32. For the UNIX R32, GREE Canada publishes a sentence, with no table: the page then shows the range between its two certified points.
What each document states, group by group
UNIX R32: GREE Canada brochure 062025. FLEXX ULTRA R32: GREE submittal dated January 27, 2026. When a document is silent, the page says so; a brochure’s silence does not prove a feature is absent.
UNIX R32 : heating stated down to −30 °C; “Ultra Heat”. The brochure does not mention a base pan heater; the NEEP record lists one of 160 W, on below 1 °C or during defrost.
FLEXX ULTRA R32 : heating stated down to −30 °C; base pan and compressor with electric heater; so-called intelligent defrosting and preheating. NEEP lists the same base pan heater, 160 W.
UNIX R32 : two-stage, two-cylinder compressor; “DC Inverter” technology.
FLEXX ULTRA R32 : GREE G20, double cylinder, two-stage inverter; ultra-low-frequency torque control; power factor correction.
UNIX R32 : compatible with 24 VAC thermostats and with RS485 communication.
FLEXX ULTRA R32 : compatible with 24 VAC thermostats; the January 2026 submittal lists a WK-010WC1 programmable wired controller as included.
UNIX R32 : refrigerant leak detector listed among the brochure’s features.
FLEXX ULTRA R32 : A2L leak detection sensor factory installed in the indoor unit.
UNIX R32 : 1,000 CFM at a rated external static pressure of 125 Pa (0.5 in w.g.); compatible with downflow applications.
FLEXX ULTRA R32 : 1,000 CFM; external static pressure up to 1.0 in w.c.; 5 speeds.
UNIX R32 : optional backup heat; the brochure gives no kW ratings and refers to the technician for the electrical calculation.
FLEXX ULTRA R32 : optional electric heater of 5, 6, 9, 10, 12 or 15 kW.
UNIX R32 : external service valves and electrical terminals to ease installation; retrofit installation possible, per the brochure.
FLEXX ULTRA R32 : “Zero Lot Line Design”; stated match with a GREE or competitive indoor unit.
UNIX R32 : not mentioned in the brochure.
FLEXX ULTRA R32 : gold fins outdoors (1,500 h salt spray) and blue fins indoors (500 h).
Published sound: the same figures on both sides
Each document gives one sound pressure value for the indoor unit and one for the outdoor unit. Both series list 51 and 61 dB(A). The Canadian data sheet for the GUD36W2/NhE-D(U) adds “as low as 56 dB(A)” for the outdoor unit, without stating at which speed.
How to read these figures. The dB(A) measures a noise level as the ear perceives it: the lower the figure, the quieter the unit. Each dot is a value published by the manufacturer. An air handler usually sits in a basement or a closet: what is heard in the rooms also depends on the ducts and their insulation.
Why this is not a ranking. GREE publishes neither the distance, the speed nor the conditions of these measurements, in either document. Matching figures on paper do not guarantee the same noise once the unit is installed.
Indoor unit (air handler)
One value published per document, with no speed stated.
Outdoor unit
One value published per document.
Both GREE documents publish the same values, without describing the measurement method.
Outdoors, in the basement and in the piping
The published cabinets have the same dimensions and the same weights. The documents part on the piping: maximum length, length covered by the factory charge and height difference.
UNIX R32 GUD36W2/NhE-D(U)
Minimum clearances with obstacles behind and on the sides, and an obstacle in front: GREE data sheet for the GUD36W2/NhE-D(U) (greehvac.ca), page 6.
FLEXX ULTRA R32 FXU36HP230V1R32AO
Same minimums in the GREE submittal dated January 27, 2026, page 6, and in the installation manual (100, 300 and 1,000 mm).



The published dimensions, at the same scale
A drawing, not a photo. Width × height × depth and net weights: GREE Canada brochure 062025 for the UNIX R32 (540 × 1,224 × 540 mm and 990 × 960 × 370 mm) and the GREE January 2026 submittal for the FLEXX ULTRA R32. Both documents give the same dimensions to within a fraction of an inch (37 51/64 and 37 13/16 in high for the outdoor unit).
The piping length between the two units
| Installation, per each document | UNIX R32 | FLEXX ULTRA R32 |
|---|---|---|
| Max. piping length | 98 ft (30 m) | 164 ft (50 m)published minimum: 10 ft |
| Pre-charged length | 24.6 ft (7.5 m)“standard pipe length” in the brochure | 31 ft (9.4 m)January 2026 submittal; 25 ft in the brochures. Beyond: 0.323 oz per foot |
| Max. height difference | 49 ft (15 m) | 49 ft (15 m)January 2026 submittal; the May 2025 submittal listed 98 ft |
| Liquid – gas diameters | 3/8 – 3/4 in | 3/8 – 3/4 in |
| Outdoor unit W × H × D, weight | 39 × 37 51/64 × 14 9/16 in, 187.4 lb | 39 × 37 13/16 × 14 9/16 in, 187.4 lb |
| Indoor unit, weight | 21 17/64 × 48 3/16 × 21 17/64 in, 163.1 lb | 21 1/4 × 48 3/16 × 21 1/4 in, 163.1 lb |
| Electrical protection | Outdoor: 27.7 A minimum, 30 A protection. Indoor: 5.3 A, 15 A protection208-230 V, 60 Hz, single phase; values without electric backup heat | Outdoor: 27.7 A minimum, 30 A protection. Indoor: 5.3 A, 15 A protection208-230 V, 60 Hz, single phase; values without electric backup heat |
| Dehumidification | Not published by the manufacturerfor the air handler, in brochure 062025 | 2.85 L/h6.02 US pints per hour in the submittal (6.02 × 0.4732 L) |
| Heating / cooling range, as published | −30 to 24 °C / −15 to 54 °C | −30 to 24 °C / −15 to 54 °C−22 to 75 °F and 5 to 129 °F in the submittal |
| Published clearances, single unit | 4 in behind, 4 and 12 in on the sides, 40 in in front of an obstacle | 4 in behind, 4 and 12 in on the sides, 40 in in front of an obstacle |
The questions we get about these two series
Are these two names for a single heat pump?
The documents do not say so, and this page does not conclude it. What can be checked: the model numbers and the AHRI certificates are different; 14 of the 17 certified lines compared carry the same values; the published dimensions, weights, R-32 charge and sound values are the same. The three certified differences are SEER2 (18.2 and 18.0), maximum capacity at −8.3 °C (32,200 and 32,600 BTU/h) and maximum COP at 8.3 °C (3.17 and 3.20).
Which one costs less to run?
For heating, our estimate gives both the same amount, since the certificates carry the same HSPF2 in Region V (7.6). For cooling, the UNIX R32’s SEER2 of 18.2 and the FLEXX ULTRA R32’s 18.0 give a difference of about one dollar a summer under the page’s default conditions. The full method is under the calculator.
Down to what temperature do they heat?
Both documents state heating down to −30 °C. Both certificates give 34,000 BTU/h at maximum at −15 °C and 20,400 BTU/h at maximum at −30 °C, with a COP of 1.31 at that last point. Below −30 °C, none of the documents consulted publishes a capacity.
Do I have enough room in my yard?
The published cabinet is 39 in wide, 37 13/16 in high and 14 9/16 in deep for both series. Between a wall and a fence, the table asks for 4 in behind and 40 in in front, 58 9/16 in in all. Under a balcony, it asks for 40 in above and up to 80 in in front. The drawing in the “In the yard” section does the math for your space; the final location is confirmed on site, before installation.
Why do the brochures not show the same figures as this page?
Because this page follows the AHRI certificates. The cover of the UNIX R32 brochure shows an EER2 of 12.5 and a COP of 3.60, which belong to the 2-ton model; its table gives the 3-ton a SEER2 of 18.0 and an EER2 of 12.0, while the certificate lists 18.2 and 11.2. For the FLEXX ULTRA R32, the French brochure prints a SEER2 of 16.5, and the January 2026 submittal a SEER2 of 18.2 and an EER2 of 12.0, while the certificate lists 18.0 and 11.2.
Are they eligible for financial assistance?
Both certificates are listed as ENERGY STAR cold climate in the NEEP directory and in ENERGY STAR’s own. Eligibility for a program such as LogisVert is checked by AHRI number in Hydro-Québec’s tool, on the day of the quote, because the lists change. This page gives no amount and promises no eligibility.
Can I keep my furnace and add only the outdoor unit?
Both series exist in an ADD-ON version: the outdoor unit is then matched with a cased coil set on a furnace. That is a different combination, with its own AHRI certificate and certified efficiencies different from the ones compared here. Compatibility with your furnace is checked before the quote.
The certified values, all in one place
| Certified value (AHRI, published by NEEP) | UNIX R32 | FLEXX ULTRA R32 |
|---|---|---|
| Identification | ||
| AHRI certificate · NEEP record | 217120760 · 378411GUD36AH2/G-D(U) + GUD36W2/NhE-D(U) | 215213330 · 392095FXU36HP230V1R32AH + FXU36HP230V1R32AO |
| Series in the NEEP directory | E Series | FLEXX High-efficiency Series |
| Refrigerant | R-32GWP 675 (IPCC AR4); class A2L (ASHRAE 34) | R-32GWP 675 (IPCC AR4); class A2L (ASHRAE 34) |
| ENERGY STAR | Yes, cold climate | Yes, cold climate |
| Seasonal efficiency | ||
| SEER2 | 18.2 | 18.0 |
| EER2 | 11.2 | 11.2 |
| HSPF2 Region IV | 10.0 | 10.0 |
| HSPF2 Region V | 7.6 | 7.6 |
| Cooling at 35 °C (95 °F) | ||
| Rated capacity at 35 °C | 34,000 BTU/h | 34,000 BTU/h |
| Capacity at 35 °C, min. / rated / max. | 11,800 / 34,000 / 34,500 BTU/h | 11,800 / 34,000 / 34,500 BTU/h |
| Heating at 8.3 °C (47 °F) | ||
| Capacity, min. / rated / max. | 11,200 / 34,000 / 34,400 BTU/h | 11,200 / 34,000 / 34,400 BTU/h |
| COP, min. / rated / max. | 4.62 / 3.20 / 3.17 | 4.62 / 3.20 / 3.20 |
| Heating at −8.3 °C (17 °F) | ||
| Capacity, min. / rated / max. | 9,200 / 32,600 / 32,200 BTU/h | 9,200 / 32,600 / 32,600 BTU/h |
| COP, min. / rated / max. | 2.64 / 2.50 / 2.47 | 2.64 / 2.50 / 2.47 |
| Heating at −15 °C (5 °F) | ||
| Capacity, min. / rated / max. | 16,000 / 34,000 / 34,000 BTU/h | 16,000 / 34,000 / 34,000 BTU/h |
| COP, min. / rated / max. | 2.29 / 2.00 / 2.00 | 2.29 / 2.00 / 2.00 |
| Coldest point on the certificate | ||
| Test temperature | −30 °C (−22 °F) | −30 °C (−22 °F) |
| Capacity, min. / max. | 15,000 / 20,400 BTU/h | 15,000 / 20,400 BTU/h |
| COP, min. / max. | 1.40 / 1.31 | 1.40 / 1.31 |
higher marks the higher value of the same measure, under the same conditions. It is not a recommendation. Capacities and COPs by point are not highlighted. The brochures and data sheets of both series sometimes print other efficiencies (see the questions): this page follows AHRI certificates 217120760 and 215213330.
Both are on AirGreen’s site.
To choose for your house, talk it over with our team: bring the heated area, the state of your ducts, the space available in the yard and your current heating.
Documents consulted
Data verified on November 9, 2026. Performance: AHRI certificates and the NEEP database. Dimensions, sound, piping and features: per the manufacturer. When a source contradicts the AHRI certificate, the certificate prevails.
Trademarks. GREE, UNIX and FLEXX ULTRA are trademarks of their respective owners. Logos are used only to identify the products compared. AirGreen is a dealer of the brand; this page is not produced, sponsored or approved by the manufacturer.
Photos: AirGreen and manufacturers, for identification.
Does a figure look wrong to you? Write to us: any figure reported is rechecked.