A.C.R. Copper Cap

In stock

The copper cap that seals the end of a refrigerant tube, tightly and for good.

AirGreen codeAG-RC-00802

3/8 to 2-5/8 in10 sizes
Femaleslides over the tube
Brazedpermanent seal
ACR copperBrazed fitting
Diameter
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

AirGreen codeAG-RC-00802
MaterialCopper
ConnectionBraze, female (C)
PurposeClosing a tube end
SoldEach

The A.C.R. copper cap is a brazing cap that seals the end of a refrigerant tube. It slides onto the tube by its female end (C), then the joint is brazed: the seal is leak-tight and permanent.

When should a line be capped?

The most common case is the abandoned line: a unit is removed or moved, and the piping left in place has to be sealed properly. The cap is also used at the end of a header, on a line left as a stub-out for a future connection, or to close a branch on a tee that is no longer needed. During a test, it also lets you pressurize an isolated section of line.

Brazed cap or job-site cap?

  • Brazed cap: a permanent seal that holds pressure like the rest of the circuit. To reopen it, the tube has to be cut.
  • Job-site cap: temporary protection against dust and moisture during the work, removed before connection.

Ten diameters, from 3/8 in to 2-5/8 in

The cap is offered for tubes of 3/8, 1/2, 5/8, 3/4, 7/8, 1-1/8, 1-3/8, 1-5/8, 2-1/8 and 2-5/8 in outside diameter.

Before opening a circuit

The refrigerant must be recovered before cutting a line. In Québec, this work is reserved for holders of the certificate required by the Règlement sur les halocarbures. Clean the tube, slide the cap all the way on and braze under a light flow of dry nitrogen.

Supplied and installed by AirGreen across Greater Montréal

Our refrigeration technicians recover the refrigerant, then cut and cap the lines when removing or replacing a unit in Montréal, Laval, Longueuil, the South Shore and the North Shore. RBQ licence 5645-9605-01. To check availability or get a quote, call us at 514 316-2973 or email sales@airgreen.ca with the diameter and quantity.

01 · What it is for

Closing a tube for good

The cap slides over the tube end and is brazed: the line is closed permanently.

  • Closing an abandoned line after equipment removal
  • End of a header or a line stubbed out for a future connection
  • Closing an unused tap on a tee
  • Pressurizing an isolated section of line for a test
Leak-tightOnce brazed, the cap holds pressure like the rest of the line.
Slides over the tubeFemale end: the tube fits into the cap, then the joint is brazed.
Ten sizesFrom 3/8 in to 2-5/8 in outside diameter.
02 · Sizes

10 sizes, one page

Each size has its own AirGreen code. Tap a row to select it.

DiameterAirGreen code
3/8 inAG-RC-00801
1/2 inAG-RC-00802
5/8 inAG-RC-00803
3/4 inAG-RC-00804
7/8 inAG-RC-00805
1-1/8 inAG-RC-00806
1-3/8 inAG-RC-00807
1-5/8 inAG-RC-00808
2-1/8 inAG-RC-00809
2-5/8 inAG-RC-00810

Outside diameter of the tube being closed, in inches.

03 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

TypeBrazed cap
ConnectionBraze, C (female)
MaterialCopper
UseRefrigerant circuits (ACR)
SoldEach
AirGreen codeAG-RC-00802
04 · Before installing

What to know before installing

  • The size is the outside diameter of the tube being closed.
  • A brazed cap is permanent: reopening means cutting the tube.
  • To protect a tube during work, a removable job-site plug is enough.
  • Recover the refrigerant before opening a circuit; this work is reserved for a qualified technician.
05 · Goes with

You may also need

Same category
Copper fittings
See all
06 · Questions

Frequently asked questions

Can a brazed cap be removed?

Not without cutting the tube. If the line may be reused, leave enough length to cut behind the cap and reconnect later.

Is the size the tube or the cap?

The outside diameter of the tube. A 7/8 in cap slides over a tube with a 7/8 in outside diameter.

Does the refrigerant have to come out before capping a line?

Yes. The refrigerant must be recovered before the circuit is opened. In Québec, this work is reserved for holders of the attestation required by the Halocarbon Regulation.

Can you cap an abandoned line?

Yes. Our technicians recover the refrigerant, cut and cap the lines when removing or replacing equipment.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Copper caps to close your lines

Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom