14/4 Communication Cable for Heat Pumps
The 4-conductor 14 gauge cable that connects a heat pump’s indoor unit to its outdoor unit.
AirGreen codeAG-EL-002
514 316-2973 · sales@airgreen.ca
Quick facts
The 14/4 communication cable has 4 conductors of 14 gauge. On a wall-mounted heat pump or a multi-zone system head, it connects the outdoor unit to the indoor unit: it powers the indoor unit and carries communication between the two, according to the manufacturer’s wiring diagram.
A single cable between the two units
On most wall-mounted heat pumps, the main power supply comes in at the outdoor unit. An interconnecting cable then runs to the indoor unit, along with the refrigerant lines and the drain, through the wall opening. That cable is how the two units talk to each other: set point, mode, defrost, error codes. The wrong cable, or a poorly connected one, causes communication errors that are hard to diagnose.
Follow the unit’s manual
- The heat pump’s installation manual specifies the required number of conductors and gauge.
- The conductors connect to the numbered terminal blocks on each unit, in the same order.
- Part of the cable runs outdoors: it must be rated for that use.
- When replacing equipment, the old cable can only be reused if it is in good condition and suitable for the new unit.
A job for an electrician
Electrical connections are reserved for an electrical contractor. AirGreen holds RBQ licence 5645-9605-01, subcategory 16 (electrical), and is a member of the CMEQ. Our technicians run and connect the cable as part of your heat pump installation.
Installed by AirGreen in Greater Montréal
We run the interconnecting cable on every heat pump installation in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. For availability or a quote, call us at 514 316-2973 or email sales@airgreen.ca with the length and quantity.
The link between the two units
On most wall-mount heat pumps, a single cable connects both units: power and communication.
- Link between the outdoor unit and the wall-mount indoor unit
- Indoor heads of multi-zone systems
- Replacing a damaged interconnect cable
- Extending the run when an indoor unit is moved
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Your heat pump’s manual states the number of conductors and the gauge required: follow it.
- Part of the cable is outdoors: it must be suited to that use.
- The cable connects to the numbered terminal blocks of each unit, in the same order.
- The connection must be made by an electrical contractor.
You may also need
Outdoor Disconnect Switch for Heat Pump
Copper Electrical Wire
Pre-Insulated Line Set for Wall-Mounted Heat Pump – 50 ft Roll
RoughinBox RBX3-MD-NC Recessed Wall Box for Drain and Lines
Breaker for Residential Electrical Panel
RectorSeal RSH-50 Surge Protective Device
Surge Protector for HVAC Equipment – 20 kALine sets, brackets, cover, drain, disconnect and cable on one page.See the kitSame category
ElectricalSee all
Frequently asked questions
Does my unit need a 14/4 cable?
Many wall-mount heat pumps do, but not all. The installation manual states the required cable; send us the model and we check.
What does 14/4 mean?
14 gauge, 4 conductors. On a wall-mount heat pump, these conductors carry the indoor unit’s power and the communication between the two units, following the maker’s wiring diagram.
Can I reuse the old cable when replacing a unit?
Only if it is in good condition and matches what the new unit calls for. We check it on site.
Can you install it?
Yes. AirGreen holds RBQ subclass 16 (electrical): our technicians run and connect the cable when they install your heat pump.
A reliable link between your two units
Tell us the size and the quantity: we confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 7, 2026.