BRADFORD WHITE RE110U6-1NAL Electric Water Heater (10 gallons) | Montreal, Laval, Longueuil, South Shore & North Shore

In stock
SKU: RE110U6-1NAL
38 L10 US gal of storage
1,500 Wper element
6 yrstank warranty
Talk to an expert · 514 316-2973
6-year tank warranty, 6-year parts3/4 in NPT connections120 V
01 · Why this model

What sets the Bradford White RE110U6 apart

10 US gal

Point-of-use reserve

A 10 US gal (8 imp. gal, 38 L) tank for a remote sink or powder room.

17 7/16 in

Very low profile

17 7/16 in tall with a 16 in diameter per spec sheet C1222.

44 lb

Shipping weight

Approximate shipping weight of 44 lb, easy to carry down a narrow stair.

120 V

Single element

Factory-wired for 120 V single phase with one 1,500 W element.

02 · How it works

Cold water at the bottom, hot water on top

Cold watergoes down the dip tubeHot waterdrawn from the topUpper elementand its thermostatLower elementand its thermostatCold waterarrives at the bottom
  1. Cold water arrives at the bottom of the tank. Hot water, being lighter, stays on top, where it is drawn.
  2. The elements, each controlled by its thermostat, bring the water back to the set temperature.
  3. Foam insulation limits the heat lost while the water waits.
03 · Will it fit?

Check the height and the way in before our visit

It travels upright. Measure the ceiling at the spot and the narrowest door on the way.

in
in

Unit: 17.44 in tall (443 mm), 16 in across (406 mm), about 44 lb shipping weight. The clearances the manufacturer requires are checked on site.

04 · Your current tank

How old is yours?

The year it was made is on the tank’s rating plate. Enter it.

Signs it is wearing out

  • Hot water runs out sooner than it used to.
  • The water comes out slightly reddish.
  • Rust shows at the bottom of the tank.
  • Moisture or drips around the unit.

Manufacturers announce a 10 to 15 year life. Many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age (CAA-Québec). Check your policy.

05 · Installation

What the spot needs, and who does what

120 V circuit1,500 W element. A dedicated circuit, sized by our electrician.
3/4 in NPT waterCold inlet, hot outlet and an accessible shut-off valve.
T&P valveTemperature and pressure relief valve, with its discharge line.
Pan and detectorDrip pan under the tank and a leak detector: strongly recommended (CAA-Québec).
60 °C, 49 °CTank set to 60 °C against bacteria; 49 °C max at the shower and tub (Construction Code, art. 2.2.10.7).

AirGreenFree visit and quote, electrical connection (RBQ licence 5645-9605-01, subclass 16), start-up.

PlumberWater connections and relief valve by a master pipe-mechanic (CMMTQ).

YouA photo of the rating plate, the spot and the stairs saves us a trip.

06 · Maintenance

A few habits that make it last

  1. Start-up daySetting the temperature, with you.
  2. Every yearPartial drain to flush sediment, and a test of the relief valve.
  3. Depending on your waterAnode inspection: it wears so the tank steel does not. In hard water it goes faster.
07 · Spec sheet

Every figure, with its source

Capacity and performance
Model
RE110U6-1NAL
Capacity
10 US gal · 38 L
Recovery
7 US gal/h · 26 L/h
Electrical
Supply
120 V, single phase
Element
1,500 W
Element type
Screw-in
Dimensions and connections
Height
17.44 in · 443 mm
Diameter
16 in · 406 mm
Shipping weight (approx.)
44 lb · 20 kg
Water connections
3/4 in NPT
Build and warranty
Inner lining
Vitraglas with Microban
Limited warranty, tank
6 years
Limited warranty, parts
6 years

Manufacturer data. Detailed sources at the bottom of the page.

08 · Same family

The size below and above

09 · Questions

What people ask us most

Is there a LogisVert grant for this water heater?

No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) lists no water heater among its eligible measures. At quote time we check other programs that could apply to your address.

Electric or heat pump: which should I choose?

An electric tank costs less up front, takes less room and needs no condensate drain or air volume around it. A heat pump water heater costs more but uses far less: the “Cost per year” section shows the gap for your household.

What temperature should the tank be set to?

To 60 °C, as the Québec government recommends, to limit bacterial growth. At shower and tub valves, the Construction Code caps the water at 49 °C: that is the job of the valve or a thermostatic mixing valve.

Can my insurer require me to replace it?

Often, yes. According to CAA-Québec, many insurers require replacement after 10 or 12 years and may refuse a water damage claim past that age. The manufacture date is on the rating plate.

Who does the installation?

AirGreen does the visit, the electrical connection under its RBQ licence (subclass 16) and the start-up. The water connections are done by a master pipe-mechanic (CMMTQ).

10 · AirGreen

We check the spot before we sell you anything

Free on-site estimate, written quote. Send a photo of your current tank and its plate, and we prepare the visit.

Book my free estimate
Sources checked November 2, 2026.
  1. Bradford White Canada, Utility Electric Residential spec sheet C1222-0626 CANADA · docs.bradfordwhite.com
  2. Bradford White For The Pro, Utility Electric Canada product page · forthepro.bradfordwhite.com
  3. Bradford White Limited Residential Water Heater Warranty 238-39699-00ZAN · docs.bradfordwhite.com
  4. Québec.ca, “Eau chaude”, updated November 5, 2025 (186 L/day, 7 °C water, 60 °C, volumes per use).
  5. Québec Construction Code, Chapter III Plumbing, art. 2.2.10.7 (RBQ).
  6. CAA-Québec, “Chauffe-eau: quelle capacité choisir”, updated June 29, 2026.
  7. Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.

Costs shown are indicative estimates before tax.

A small 10 US gallon tank for the workshop, the office or the cottage

Not every building needs a large tank. A garage workshop with a utility sink, a small office with a kitchenette, a commercial space with a washbasin or a cottage used mostly in summer have modest needs, but they deserve reliable hot water. The Bradford White RE110U6-1NAL electric water heater meets these uses with a tank of 10 US gallons (8 imperial gallons, 38 L), a single 1,500 W element and a 120 V supply. AirGreen installs it in Montreal, Laval, Longueuil, on the South Shore and on the North Shore.

The middle size of the utility line

Bradford White's residential utility line has three compact sizes. The RE110U6-1NAL sits in the middle: more reserve than the very small model designed to hide under a sink, but a much smaller footprint than the largest size in the line. At 17 7/16 in. tall and 16 in. in diameter, it fits on a workshop floor, in a utility closet or under a deep enough counter. Its weight of 44 lb also makes it easy to carry down a narrow staircase or into an accessible crawl space.

What it is used for

This tank is made for occasional needs: washing hands after dirty work, rinsing tools, doing the dishes in an office kitchenette or supplying the sink of a small break room. In a business, it can serve a washbasin and a utility sink located in the same spot. It is not designed for a daily shower or to replace a home's water heater; for those uses, we offer you a standard-size residential tank.

Manufacturer data

  • Capacity: 10 US gallons, 8 imperial gallons, 38 L.
  • Factory configuration: 120 V, single 1,500 W element, unless otherwise specified.
  • Recovery: 7 US gal/h or 6 imp. gal/h at a 90 °F rise; 26 L/h at a 50 °C rise, based on 1,500 W.
  • Element: immersion, screw-in, copper, with an INCOLOY-type element available on request.
  • Connections: water and electrical in 3/4 in. (19 mm) NPT, factory-installed dielectric fittings.
  • Tank protection: Vitraglas with Microban lining.
  • Height: 17 7/16 in. (443 mm); diameter: 16 in. (404 mm).
  • Weight: 44 lb (20 kg).

Voltage and wattage: the available options

The RE110U6-1NAL is factory-wired for 120 V with a 1,500 W element, so it can be fed by an ordinary 120 V circuit reserved for the unit. Bradford White offers the series in 120 V, 208 V, 240 V, 277 V and 480 V, single-phase only. Its limitations table covers wattages from 1,500 W to 6,000 W depending on the voltage; at 120 V, only wattages from 1,500 W to 3,000 W are allowed. A different configuration must be specified when ordering. In a workshop where a 240 V panel is already in place, we assess with you whether another combination is useful, but the factory configuration suits most of the uses described here.

Recovery suited to occasional needs

At 1,500 W, the element heats 7 US gallons per hour for a 90 °F rise. In practical terms, the 10 US gallon reserve is rebuilt in under an hour and a half after being completely drained, which works well for uses spread out over the day. For continuous use, such as repeatedly filling a large tub, a larger size or a different wattage would be more appropriate.

Construction and compliance

The tank is protected by the Vitraglas with Microban lining, and the copper immersion element screws into the tank, which makes it easy to replace. The factory-installed dielectric fittings separate the steel of the tank from the copper of the piping. Bradford White states that all models in the series are UL listed, and that applicable models are verified by CSA for energy performance under standard C191.1-M90.

Manufacturer's warranty

This model has a 6-year limited warranty on the tank and 6 years on parts. The full terms are attached to the quote.

AirGreen installs your RE110U6-1NAL cleanly and by the rules

AirGreen is a family-owned heating and cooling company established in Montreal, active for more than fifteen years and holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). We start with a free on-site estimate, then give you a written quote. Installation includes:

  • assessing the location, access to the connections and protection against freezing;
  • draining and removing the old tank, where applicable;
  • connecting the cold and hot water in 3/4 in. NPT;
  • installing the relief valve and its discharge line to a safe location;
  • the electrical connection on a 120 V circuit reserved for the unit;
  • filling the tank completely, powering it up and setting the temperature;
  • maintenance advice and, if needed, seasonal draining instructions.

Lightly heated buildings and cottages

In a garage or cottage that is not heated year-round, the water in the tank and piping can freeze during the Quebec winter and damage the tank. If the building stays cold for several weeks, we show you how to cut the power, shut off the water and drain the tank completely before the cold season, then how to fill it before powering it up again in spring. For a heated building, one partial flush per year and a test of the relief valve are enough.

Service area

We work in Montreal, Laval, Longueuil, Mirabel, Kirkland, Dollard-des-Ormeaux, Beloeil, Saint-Constant and everywhere on the South Shore and the North Shore. If the installation is part of a larger project, our financing lets you spread out the cost.

Request your free estimate for the Bradford White RE110U6-1NAL. Tell us where hot water is needed and attach a photo of the intended location: we will reply with a clear recommendation.